Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.0 CrAdmitted-Finance | ₹12.0 Cr | L1 | Admitted-Finance |
| 2 | L2₹13.4 CrAdmitted-Finance | ₹13.4 Cr | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Mohammad Nashir Shah L1 | Santa Biren L2 |
|---|---|---|---|---|---|
| .10SH: Main Building | |||||
| 1.00 | Earth work in Excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift upto 1.5m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. a) Hard / Dense soil. . | 1,918.86 | cum | - | - |
| 2.00 | Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m. | 639.56 | cum | - | - |
| 3.00 | Filling with sandy soil under floors including watering, ramming, consolidating and dressing complete . | 2,382.75 | cum | - | - |
| 4.00 | P/L cement concrete in foundation and plinth excluding the cost centering and shuttering. (a) 1:4:8 (1 cement : 4 coarse sand : 8graded stone aggregate 40 mm nominal size). | 256.86 | cum | - | - |
| 5.00 | Providing and laying in position specified grade of reinforcement cement concrete excluding the cost of centering, shuttering, finishing and reinforcement (all work plinth level). A. 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). | 499.12 | cum | - | - |
| 6.00 | RCC work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses fillets, columns, pillars, abutments, posts and struts etc upto floor five level excluding the cost of centering, shuttering, finishing and reinforcement in 1:1.5:3.(1 cement : 1.5 coarse sand : 3 graded stone aggrt, 20mm nominal size). | 161.53 | cum | - | - |
| 7.00 | RCC work in beams, suspended floors, roofs having slope upto 15º landings, balconies, shelves, chajjas, lintels, bands, plain window sill, staircases and spiral stair cases upto floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3.(1 cement : 1.5 coarse sand : 3 graded stone aggrt, 20mm nominal size). | 701.11 | Cum | - | - |
| 8.00 | Reinforcement for RCC work i/cbending, binding and placing in position complete. (a) Thermo-mechanically treated bar | 1,95,254.99 | kg | - | - |
| 9.00Providing form work i /c centering and shuttering so as to give a rough finish, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for in-situ reinforced concrete and plain concrete work in | |||||
Tender Value
₹12.7 Cr
EMD Value
₹25.4 L
Closing Date
10 Sept 2020, 12:00 pmClosed
The Executive Engineer, B.D-II,P.W.D., Manipur
P.W.D Complex, Manipur
Construction of Lokayukta Manipur Office Building at DC Imphal West Complex, Lamphelpat
2020_PWDM1_983_1
EE/BD-II/etender/2020-21/01
Open Tender
Civil Works - Buildings
540 days
As per Tender Documents
Please refer Tender documents.
5 documents required · 5 mandatory
₹5,000
EE, Building Division No.II, P.W.D., Manipur
₹25.4 L
PWD Complex, Khuyathong, Manipur
3 Oct 2020
27 Aug 2020
10 Sept 2020
27 Aug 2020
10 Sept 2020
27 Aug 2020
5 Sept 2020
Amount
SH: Main Building
Earth work in Excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift upto 1.5m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. a) Hard / Dense soil. .
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
Filling with sandy soil under floors including watering, ramming, consolidating and dressing complete .
P/L cement concrete in foundation and plinth excluding the cost centering and shuttering. (a) 1:4:8 (1 cement : 4 coarse sand : 8graded stone aggregate 40 mm nominal size).
Providing and laying in position specified grade of reinforcement cement concrete excluding the cost of centering, shuttering, finishing and reinforcement (all work plinth level). A. 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).
RCC work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses fillets, columns, pillars, abutments, posts and struts etc upto floor five level excluding the cost of centering, shuttering, finishing and reinforcement in 1:1.5:3.(1 cement : 1.5 coarse sand : 3 graded stone aggrt, 20mm nominal size).
RCC work in beams, suspended floors, roofs having slope upto 15º landings, balconies, shelves, chajjas, lintels, bands, plain window sill, staircases and spiral stair cases upto floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3.(1 cement : 1.5 coarse sand : 3 graded stone aggrt, 20mm nominal size).
Reinforcement for RCC work i/cbending, binding and placing in position complete. (a) Thermo-mechanically treated bar
Providing form work i /c centering and shuttering so as to give a rough finish, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for in-situ reinforced concrete and plain concrete work in
(a) Foundation, footings, bases of columns etc. and mass concrete.
(b) Flat surface such as suspended floor, roofs, landings and the like floors upto 200 mm in thickness.
(c) Vertical surface such as walls of any thickness, partitions and the like i/c attached pillasters, buttresses, plinth & string courses and the like.
(d) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
(e) Sides soffits of beams, beam hunching, cantilevers, girders bressumers and lintels (Not exceeding 1.0 m. in depth).
(f) Stair cases with sloping or stepped, soffits i/c risers and stringers excluding landing
2 nd class (local first class) brick work in foundation and plinth with cement mortar 1:3 (Course sand)
2nd class (local first class) brick work in superstructure above plinth level upto 1st floor level in cement mortar 1:3 (1 cement: 3 course sand)
Half brick masonry 2 nd class (local first class) in cement mortar 1:3 ( 1 cement: 3 course sand) in Superstructure.
Providing wood works in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position.
P/F 40 mm. thick paneled, glazed or paneled and glazed shutters for doors, windows and clerestory windows i/c bright finished brass hinges (with ordinary type) with necessary screws.
P/F 20 mm. thick battened framed door shutters i/c bright finished or black enameled iron butt hinges with necessary screws. (a) Local best quality Uningthou wood.
Providing & fixing bright finished steel 100 mm door mortice latch & lock & a pair of levers handles with necessary screws etc. complete (Indian make of approved quality)
Providing and fixing BrassTower bolts (barrel type) with screws etc. complete (a) 250 x 10 mm.
Providing and fixing Brass Handles with necessary screws etc. complete. a) 125 mm.
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315 , having brand logo embossed on the body/ plate with double spring mechanism and door weight upto 125 kg, for doors including cost of cutting floors ,embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-Charge.
Providing and fixing Brass sliding bolts bright finished or black enamelled with nuts & screws etc. complete. (a)300 x 16 mm
Providing and fixing rolling shutters of approved make made of 80mm wide M.S. laths interlocked together through their entire length or jointed together at the end by end brackets plates, (guides) channels of arrangements for inside and outside locking with push pull operation complete but excluding the cost of hood cover and spring (a) Shutters having width below 3.5m.
Providing & fixing 27.5 cm. long wire spring grade no.2 for rolling shutters.
Providing & fixing hood cover for rolling shutters. Shutters having width below 3.5m.
Supplying H.D. bolts 106 cm. long with 12 mm dia iron rod for fixing the post plate or wall plate i/c cost of nuts.
Supplying 40 mm X 3 mm X 275 mm F.B. twisted plate i/c cost of bolts & nuts.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Marble stone slab flooring over 20 mm (average) thick base of cement mortar 1 : 6 (1 cement: 6 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with (a) Black/Green Slab 20 mm thick
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. (a) Side of Tile 600 x 600 mm (Double Charged) branded
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. (a) Side of Tile 600 x 600 mm (Double Charged) branded
Granite stone slab flooring over 20 mm (average) thick base of cement mortar 1:6 (1 cement : 6 course sand) laid and jointed with grey cement slurry including rubbing and polishing complete with
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to
Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer-in-tapered and backed by acoustical tissue with NRC value not less than 0.60.charge and as per manufacturer's specification, with all 4 side
Trapzoidal Pre-painted Profile Sheet roofing of approved brand DYNA Roof or equivalent with selt drilling screws of 68 mm long Xylon coated screws with PVC washer & caps complete, exclding the coat of purlinsr & trusses. (a) Pre painted Galvanized Iron Sheet (PPGL) (i) Profile sheet 0.50 mm/4.2 kgs/sqm
Trapzoidal Pre-painted Profile Sheet for Ridges Gutter or Valley 610 mm wide of approved brand DYNA Roof or equivalent fixed with selt drilling screws of 68 mm long Xylon coated screws with PVC washer & caps completed, exclding the coat of purlins rafter & trusses. (a) Pre painted Galvanized Iron Sheet (PPGL) (i) Profile sheet 0.50 mm/4.2 kgs/sqm
Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a coat of approved steel primer red oxide zinc chrome primer conforming to IS:2079) welded and bolted including special shape washer etc. complete. (a) Electric resistant welded tube (Conforming to IS:1611-1979)
Aluminium glazed windows and ventilators of standard aluminium extrusion section joints mitred and riveted/screwed with 15x3 mm lugs 10 cm long with steel plugs embedded in cement concrete block 15x10x10 cm of 1:3:6 (1 cement:3 coarse sand:6 stone aggregate 20 mm nominal size) or wooden plugs and screws of rawl plugs and screws or with fixing clips with bolts and nuts as required including providing and fixing of glass panes 4 mm thick, projecting hinge, handles, peg stays, bolting devices, locking arrangements, spring catch & aluminium clip beading etc as required complete.
Providing & fixing 25 mm fiber insulating board lining with butt jointing & nails complete (frame work & cover fillets to be measured & paid separately).
15 mm cement plaster 1:3 (1 cement : 3 fine sand)
Applying one coat of cement primer of approved quality on wall surface
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Painting on wall with (two coats) of plastic emusion paint of approved quality in all shades on new work to give an even shade.
Finishing walls weather shield paint of approved quality on new work(three or more coats) to give even shade.
Applying ready mixed priming coat pink primer of approved quality on new wood work.
Painting two coats (excluding priming coat) with chocolate, red, grey or buff paint of approved quality on new steel or wood work.
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : (a) Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern
P / F kitchen sink white glazed vitreous china Indian make with RS or CI brackets painted white a pair of 12.5 mm CP brass pillar tap 323mm rubber plugs and CP brass chain 32mm CP brass waist of standard pattern 32 mm dia. MI/CP brass traps and unions complete i/c cutting and making good the walls Indian fittings. 610 x 450 x 250 mm
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing 600 x120 x 5 mm glass shelf (Indian make) with C.P. brass brackets guard nail complete fixed to wooden cleats with C.P. brass screws.
Providing and fixing 610 x 20 mm diplomat brass towel rail complete with CP brass brackets fixed to wooden cleat with CP brass screws.
Providing and fixing C.P. brass toilet paper holder
Providing and fixing liquid soap container of glass with C.P. lid and brackets fixed to wooden cleats with C.P. brass screws.
Providing & fixing 50 mm HCI terminal guard.
Providing & fixing 50 mm HCI Collar.
Providing and fixing HCI traps with 100 mm inlet and 100 mm outlet of self cleaning design with HCI screwed down of hinged grating with or without vent arm complete i/c cost of cutting and making good the walls and floors.
Providing and fixing lead chaulked joints to 50 mm HCI pipes.
Providing and fixing 50 mm HCI soil, waste & vent pipes.
Providing and fixing GI pipes complete with GI fittings and clamps i/c cost of cutting and making good the walls etc. (Internal works).
Providing and fixing GI pipes complete with GI fittings and clamps i/c cost of cutting and making good the walls etc. (External works).
Making connection of GI distribution branch with GI main 25 mm to 40 mm diameter by providing & fixing Tees i/c cutting and threading the pipe etc. complete.
(Sh: - Const. of Septic Tank)
Earth work in Excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift upto 1.5m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. a) Hard / Dense soil.
P/L cement concrete in foundation and plinth excluding the cost centering and shuttering. (a) 1:4:8 (1 cement : 4 coarse sand : 8graded stone aggregate 20 mm nominal size).
P/L cement concrete in foundation and plinth excluding the cost centering and shuttering. (a) 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering and reinforcement. All work up to plinth level. (A) 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string s, fillets, columns, pillars, piers, abutment, posts and struts upto floor two level excluding the cost of centering, shuttering finishing. 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).
Providing form work i /c centering and shuttering so as to give a rough finish, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for in-situ reinforced concrete and plain concrete work in
a) Foundation, footing, bases of columns etc. and mass concrete.
(b) Flat surface such as suspended floors upto 200 mm. thickness.
(c) Sides soffits of beams, beam haunching, cantilevers, girders bressumers and lintel (Not exceeding 1.0 m. in depth).
(d) Edges of slabs and bricks in floors and walls. (Under 20 cm. Wide).
Reinforcement for RCC work i/cbending, binding and placing in position complete. (a) Thermo-mechanically treated bars steel bars.
Reinforced cement concrete work in beams, suspended floors, roof having slope up to 15 degree landing balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of shuttering and reinforcement. with (a) 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).
Half brick masonry 2 nd class (local first class) in cement mortar 1:3 ( 1 cement: 3 sand) in Superstructure.
Honeycomb brick work (75 mm) thick with 1st class brick in cement mortar 1:4 ( 1 cement: 3 sand).
15 mm cement plaster 1:3 (1 cement : 3 course sand) finished with a floating coat of neat cement.
Providing and fixing C.I cover with frame (for manhole and chambers) a) 600 x 450 mm (light duty) (25kg)
Providing & fixing 100 mm HCI terminal guard.
Providing & fixing 100 mm HCI Collar.
Providing and fixing HCI traps with 100 mm inlet and 100 mm outlet of self cleaning design with HCI screwed down of hinged grating with or without vent arm complete i/c cost of cutting and making good the walls and floors.
(Sh: - Const. of Ground sump)
Earth work in Excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift upto 1.5m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. a) Hard / Dense soil.
P/L cement concrete in foundation and plinth excluding the cost centering and shuttering. (a) 1:4:8 (1 cement : 4 coarse sand : 8graded stone aggregate 40 mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering and reinforcement. All work up to plinth level. (A) 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutment, posts and struts upto floor two level excluding the cost of centering, shuttering finishing. 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).
Providing form work i /c centering and shuttering so as to give a rough finish, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for in-situ reinforced concrete and plain concrete work in
a) Foundation, footing, bases of columns etc. and mass concrete.
(b) Flat surface such as suspended floors upto 200 mm. thickness.
(c) Edges of slabs and bricks in floors and walls. (Under 20 cm. Wide).
Reinforcement for RCC work i/cbending, binding and placing in position complete. (a) Thermo-mechanically treated bars steel bars.
Reinforced cement concrete work in beams, suspended floors, roof having slope up to 15 degree landing balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of shuttering and reinforcement. with (a) 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).
Half brick masonry 2 nd class (local first class) in cement mortar 1:3 ( 1 cement: 3 course sand) in Superstructure.
15 mm cement plaster 1:3 (1 cement : 3 course sand) with a floating coat of neat cement.
Providing and fixing C.I cover with frame (for manhole and chambers) a) 600 x 450 mm (light duty) (25kg)
(SH: Approach road, landscaping and drainage system)
Providing laying & compacting granular base/sub-base according to lines, grades& cross-sections by using naturally occurring sand gravel/conforming to IRC Grade 2 of M.O.S.T. specification free from organic or other deleterious constituents compact by rolling with power roller of 8 to10 tonnes capacity in layers not exceeding 150 mm (spread thickness)including rolling of the road surface to proper level & grade 30 cm width edging on both sides etc. complete as directed by the Engineer-in-charge.
Providing and laying one layer W.B.M. 7.5 cm consolidated thickness using 1 cum of stone aggregate conforming to IRC Grades per 10 sqm of road surface & 0.23cum of binder materials of approved quantity per 10 sqm of road surface including consolidating of the same, rolling of the surface to camber, superelevation & grade by using template straight edges & spirit level in layers not exceeding 100 mm to 130 mm thick (spread thickness), dry & wet rolling with 8 to10 tonne roller including earth edging 30 cm width on both sides & applying binding materials as specified. (i) IRC Gr-III
Providing 25 mm thick semi-dense carpeting course aggregate and filler required grading conforming to Table 500.11 of IRC specification in sufficient to yield specified thickness after compaction including through dressing of surface, screening and cleaning of stone materials making component including coarse aggregate, fine aggregate and filler to obtain homogenous mixture with requisite quantity of binder @ 5.50% by weight to mix, mixing the quantity in hot mix plant conforming to IS 3066 and laying the mixture uniformly to specified grade line and cross section over the existing surface. i) 5 kg/10 sqm
Earth work in Excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift upto 1.5m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. a) Hard / Dense soil.
P/L cement concrete in foundation and plinth excluding the cost centering and shuttering. (a) 1:4:8 (1 cement : 4 coarse sand : 8graded stone aggregate 40 mm nominal size).
Providing and laying 22 mm thick precast cement concrete chequered tiles on footpath over 20 mm thick bed of cement mortar 1:3 complete as per drawing and technical specifications.
2 nd class (local first class) brick work in foundation and plinth with cement mortar 1:3 (Course sand)
15 mm cement plaster 1:3 (1 cement : 3 fine sand)
Granite stone slab flooring over 20 mm (average) thick base of cement mortar 1:6 (1 cement : 6 course sand) laid and jointed with grey cement slurry including rubbing and polishing complete with
Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms lift upto 1.5 metres including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres (a) Hard/Dense Soil.
P/L cement concrete in foundation and plinth excluding the cost centering and shuttering in 1: 4: 8 ( 1 cement : 4 course sand : 8 graded stone aggregate 40 mm. nominal size.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete (a) Thermo-Mechanically Treated bars
Providing form work i /c centering and shuttering so as to give a rough finish, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for in-situ reinforced concrete and plain concrete work in
(a) Foundation, footing, bases of columns etc. and mass concrete.
(b) Sides so fits of beams, beam haunching, cantilevers, girders bressumers and lintel (Not exceeding 1.0 m. in depth).
Providing and laying in position specified grade of reinforcement cement concrete excluding the cost of centering, shuttering, finishing and reinforcement (all work upto plinth level) b) 1: 1.5: 3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm. nominal size).
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre
P/L cement concrete in foundation and plinth excluding the cost centering and shuttering in 1: 2: 4 ( 1 cement : 2 course sand : 4 graded stone aggregate 20 mm. nominal size.
SH :-Providing of Internal Electrical Service in the Lok Ayukta Manipur office building Block -H (Ground floor & First floor) and Block- G (First floor) at DC I/W complex,Lamphelpat).
Point wiring in recessed steel conduit,with modular type switch:
Wiring for light point / fan point / exhaust fan point / call bell point with 1.5mm2 FR PVC insulated copper single core stranded copper cond.cable in surface / recessed steel conduit with modular type switch phenolic laminated sheet suitable size MS- box and earthing the point with 1.5mm2 FR PVC insulated stranded copper conductor single core cable etc. as reqd.
Power plug wiring in recessed steel conduit 2x 4mm2:
Wiring for light / power plug with 2x4mm2 FR PVC insulated copper conductor single.core cable in surface / recessed steel conduit long with 1 no. 4mm2 FR PVC insulated copper conductor single.core cable for loop earthing etc. as reqd.
S/F recessed light plug pt. modular type accessories :-
S/F suitable size GI box with modular plate on surface or in recess with suitable size of cover in front on surface /recess i/c P/F 3 pin 5/6 amp socket outlet and 5/6 amp modular switch, connection painting etc. as reqd. (for light plugs to use in non-residential building).
S/F suitable size GI box with modular plate on surface or in recess with suitable size of cover in front on surface /recess i/c P/F 3 pin 15/16 amp socket outlet and 15/16 amp modular switch, connection painting etc. as reqd. (for light plugs to use in non-residential building).
Wiring for circuit / sub-main wiring along with earth wire with (the following sizes of)FR PVC insulated copper conductor single core cable in surface / recessed steel conduita etc. as reqd.
1. 2x2.5mm2 +1x2.5mm2 earth wire.
2. 2 x 4mm2 + 1 x 4mm2 earth wire.
3. 2 x 6mm2 + 1 x 6mm2 earth wire.
4. 2x 10mm2 + 1 x 10mm2 earth wire.
5. 2x 16mm2 + 1x 16mm2 earth wire.
6. 4x25mm2 + 2x16mm2 earth wire.
Supply for 50mm2 4core PVC/XLPE insulated heavy duty armoured cable 1.1KV grade.
Laying of 1 no.PVC insulated PVC sheathed power cable of 1.1KV grade of size not less than 120mm2 but not exceeding 400mm2 direct in ground i/c excavation,Sand cushinoning,protective covering and re-filling the trench etc.as reqd.
Fitting Accessories:
S/F 15W Surface mounting LED down light with white powder coated aluminum housing with integrated electronic driver i/c connection as reqd.
S/F 200W LED streetlight made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics,Potted driver,IP66 protection and impact resistance of IK07. i/c connection as reqd
Cost of 50mm dia.GI.pipe, light duty.
S/F 48" sweep (1200mm) A.C. ceiling fan complete with down rod, cannopy, 3 (three) blades but without regulator etc. as reqd. (Make Bajaj/Usha ro Simailar).
S/F stepped type electronic fan regulator on the existing modular plate switch box i/c connection but excluding modular plate etc. as reqd.
S/F 380mm sweep exhaust fan complete with all accessories i/c connection etc. as reqd.
S/F call / buzzer suitable for DC/AC single phase 230V complete as reqd.
S/F 25 ltr water hater (Geyser) A.C. 2 Kw vertical type with all accessories, (150558 SKT - PLUS) i/c connection etc. as reqd.
Split type Air-conditioner
S/F 25 amp Air-Conditioner power plug point /c 4 modules metal box on surface or in recess 4-modules plate and cover in front, 25 amp modular starter 25 amp modular socket outlet and 25 amp plug i/c connection etc. as reqd.
S/F 2 ton capacity split type Air-conditioner, (Diamond, 3 Star, 5G 30, G-SC 24 FD 3 WJH) complete. Etc.
S/F Indo voltage corrector Automatic/stabilizer,4KVA(140-280V)for Air conditioner( 2 ton ).
Switch gear:
SITC of cubical type floor mounted essential panel fabricated out of 16 SWG MS steel fully front operatse 4 wire 415 V AC supply system having the following switch gear and accessories i/c fabrication, painting, erection on floor with required civil works making good the damages etc.(i/c MCCB and other related items).
SITC of capacitor 75 KVAR panel.
S/F 4 way (4+12 way )double door TPN prewired, sheet steel MCCB distribution board, 240V on surface / recessed complete with loose wire box terminal blocks, duly prewired with suitable size FR PVC. Insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable glan plate, interconnection, phosphatized and powder painted inculding earthing etc. as reqd. (but without MCB/RCCB/Isolator).
P/F. 4 Pole MCCB 160amp25KA MCCB in exissting cubicle panel board i/c drilling holes in cubicle panel & making connection as reqd.
S/F5amp to32amp rating 230V'B'series MCB for lighting and other load of(following poles) in the existing MCB DB complete with connection testing and commissioning etc. as reqd.
Earthing Items:
Earthing with copper earthplate 600mm x 600mm x 3mm thick i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe ec. (but without charcoal or coke and salt).
Extra for using salt & charcoal for copper plate earth electrode as reqd.
P/L earth bus of 25mmX 5mm copper strip in40mm dia G.I. pipe from earth electrode as reqd.
Lighting Conductor.
Providing and Fixing of light conductor finial made of 25mm dia 300mm long copper tude having single prong at top with 85mm dia 3mm thick copper plate i/c holes etc.complete as reqd.
Providing and Fixing copper tape 20mm x 3mm thick on parapet or surface of wall for lighting conductor complete as reqd.(For horizontal run )
Providing and Fixing copper tape 20mm x 3mm thick on parapet or surface of wall for lighting conductor complete as reqd.(For vertical run )
P/L. copper strip 32 mmx6mm from earth electrode directly in ground as reqd.
Design, manufacture, supply, installation, testing and commissioning of Elevator system of 6 person capacity.APTO.
SH :-Providing of Fire Fighting and Alarm System in the Lok Ayukta Manipur office building Block -H (Ground floor & First floor) and Block- G (First floor) at DC I/W Complex, Lamphelpat).
FIRE FIGHTING SYSTEM
Heavy class M.S pipes conforming to IS with accessories like tees, elbows, flanged joints, rubber insertion, nuts, bolts or welded joints including fixing the pipe with suitable flat iron strip clamps/brackets, structural members, dash fastener , cutting hole and chases in walls, floor, R.C.C. slab etc. and making good the same, including painting pipes and fittings with a primer coat of steel primer and two coats of postal red enamel paint etc. complete as required. (All the fitting i.e. tee /elbow, Valve shall be joint the pumps will flanged joints)
150 mm dia (with Flanged joints)
80 mm dia (with Flanged joints)
Providing and fixing Single headed hydrants flanged inlet with 63 mm female instantaneous outlet of gunmetal complete with male blank caps, chains conforming to IS:5290 type A with stainless steel orifice plate (if required) to keep the pressure not more than 3.5 kg/sq.cm at any point.
Providing 63mm dia 30 m long reinforced rubber lined hose pipe conforming to IS: 636-1992 Part-II with gunmetal male & female coupling wire wound with pipe as required.
Providing and fixing Gunmetal branch pipe with 20mm dia nozzle conforming to IS:903. suitable for installation connections to hose coupling etc. as required.
Providing and fixing Four way fire brigade connection housed in steel cabinet of size 900mm x 750mm x 400mm fabricated from 1.5mm thick M.S. sheet having lockable arrangement, openable glazed door with 4mm thick glass, including painting a coat of steel primer and two coats of postal red enamel paint, with necessary supports for the cabinet etc. with 150 mm dia. non return and butterfly valves complete in all respects.
4 Way - 150mm dia
Providing and fixing Set of "Siamese" quadraplet instantaneous fire brigade connections comprising of two gunmetal instantaneous male inlet coupling 63mm dia with plug and cap, chain bends, tees etc for inlet to the static tank.
Providing & Fixing 150 mm dia, 4 way suction coupling for firebrigade withdrawal of water from the fire tank
Providing and fixing door for Fire hose cabinet with glazed door shutter and frame with hold fasts ( frame fabricated from 40 x 40 x 5mm and shutter from angle) 2100 mm high x 1200 mm wide x 600mm deep with locking arrangement, 4mm thick glass with M.S. flats including all accessories, painting with one coat of steel primer and two coats of postal red enamel paint complete as per drawing and as directed. The words “ hose cabinet” to be painted on the box complete in all respects.
Providing and fixing cast iron body IS: 210 FG 220 and double flange gear simple operation type butterfly valve conforming to IS: 13095 with SS304 disc and shaft NITNLE rubber replaceable seat of the following size complete with bolts, nuts, washers and rubber insertions as per specification.
150 mm dia
80 mm dia
Supplying, testing, installation & commissioning of pressure switches for pumps including necessary wiring upto the control panel.
Supply and Fixing First Aid Hose Reel, Wall ,Mounting swinging type complet with drum and bracket of MS construction, spray painted in post office Red, confiming to IS 884/1995 with upto date amendments, complet with the following as required.
36 Meter long 20 mm dia water hose Thermoplastic (Textile reinforced) Type - 2 as per IS : 12585
20 mm dia gun metal ball valve & nozzle.
Drum and brackets for fixing the equimpments on wall.
Connection from riser with stop valve (gun metal) & M.S. Pipe
Providing and fixing C.I. sluice valves (With cap) of approved quality complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) Class II
150 mm dia
Supply, Installation, Testing and Commissioning of 100 mm dia Bourden type, Stainless Steel dial type Pressure Gauge including brass isolation valve and siphon pipe having caliberation of 0 - 16 Kg / cm2 .
Supplying and Fixing of Fire Man's axe with heavy insulated rubber as per standard conforming to IS 926
Supplying and Fixing vane type waterflow switch with contacts suitable for installation on 50 mm to 150 mm dia pipeline for a service pressure upto 20 Kg/sq.cm.
Fabricating, Supplying, Installation, Testing and Commissioning Air Vessel of continuous welded construction with flanged discharge header on the top of each riser fabricated out of 10 mm thick dished ends and 8 mm thick MS sheet, Air Release Valve complete with suitable drain arrangement with 25 mm dia gun metal wheel valve complete with all accessories etc. as required of the following sizes
1.2 Metre high and 250 mm dia
Supply, Installation, Testing and Commissioning External Yard Hydrant Stand Post comprising of GI pipe 80 mm dia (heavy duty C class) from existing ringmain to about 1 meter above ground level and Single Headed Yard Hydrant Valve with 80 mm dia flanged inlet, intantanneous gunmetal coupling of 63 mm dia with cast iron wheel ISI marked, conforming to IS : 5290 (Type A), with ABS cap and chain etc.complete with all accessroies as required.
Providing and placing on terrace polyethylene water storage tank ISI : 12701 MARKED indicating the BIS license No with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Supply, erection, testing & commissioning of exit glow sign board of size 200mm x 350 mm wall mounting signage consisting of photo luminescent coating on acrylic cover
Providing and fixing fire extinguisher of carbon dioxide type consisting of brand new high pressure steel cylinder bearing IS: 7285 mark and having the approval of controller of explosives Nagpur, wheel type valve bearing IS:3224 mark internal discharge tube, 1 meter long high pressure discharge hose, non conducting horn, suspension bracket, fully charged bearing IS: making fixed to wall as directed.
4.5kg capacity cylinder
Providing and fixing 9 liters capacity fire extinguisher water type gas pressure conforming to IS marking, fixed to wall.
Providing and fixing ABC type fire extinguishers complete in all respects.
Capacity 5.0 Kg.
Providing and fixing C.I. non-return valve complete with gunmetal seat, bolts, nuts washer & rubber insertions as required conforming to IS:5312.
80 mm dia
150 mm dia
Providing & fixing electrical gang bell with all inter-connecting cables for an audio annuciation of pumps failure, complete in all respects.
1 No. 3 Phase, DOL starter of 5 HP with thermal overload relay, Push Buttons and Switches,power cable of suitable size from motor to starter including cable gland ,lugs,earth connection etc complete as required.
SITC of Fire fighting pump
FIRE ALARM SYSTEM
Supply Installation testing & Commissioning of 2 loop panel for Fire Alarm System.
Supply Installation testing & Commissioning of Smoke Detector with base
Supply Installation testing & Commissioning of Manual Call point.
Supply Installation testing & Commissioning of Sounder with Flasher.
Supply & laying of 2 core 1.5 sqmm cable with casing capping.
Santa Biren
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.84 MB
BOQ_1137.xls
BOQ • 0.40 MB
Drawing.pdf
Tender Documents • 4.84 MB
Download all tender documents and submit your bid