| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹21.5 LAccepted-AOC 37 222 BUNDU KATRA AGRA UP | AGRA | UP | 1 | Accepted-AOC Being lowest | |
| 2 | 2₹23.5 L+₹1.0 L (4.64%)Rejected-Finance | 2 | Rejected-Finance Not being lowest | |
| 3 | 3₹24.0 L+₹1.6 L (7.03%)Rejected-Finance 86 NAROTTAM KUNJ MADHU NAGAR AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | 3 | Rejected-Finance Not being lowest | |
| 4 | 4₹25.7 L+₹3.2 L (14.3%)Rejected-Finance | 4 | Rejected-Finance Not being lowest | |
| 5 | 5₹25.9 L+₹3.4 L (15.3%)Rejected-Finance 0 0 0 KHIRKITA DUBEY PAKARI GORAKHPUR UTTAR PRADESH 273412 | GORAKHPUR | UTTAR PRADESH | 273412 | 5 | Rejected-Finance Not being lowest |
Tender Value
₹33.5 L
EMD Value
₹66,900
Closing Date
26 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE AGRA
112 TAJ ROAD AGRA CANTT
SPL REPAIR TO ROOF, WALLS, FLOOR, CEILING AND ELECT FITTINGS (COMPLETE BLDG) OF AKBAR BK NO.2 OF 17 PARA FD REGT UNDER GE (WEST) AGRA
2020_MES_401059_1
84197/E8
Open Tender
Civil Works
Item Rate
180 days
AGRA
MES contractors enlisted in Class D category a(i) for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work
8 documents required · 8 mandatory
₹500
GE WEST AGRA
₹66,900
Yes
7 Jan 2021
5 Dec 2020
1 Jan 2021
5 Dec 2020
26 Dec 2020
19 Dec 2020
5 Dec 2020 - 12 Dec 2020
60 days
Amount
Taking down plain or corrugated steel sheeting any gauge thickness, including Nanital or similar pattern roof covering. complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws of appropriate size as per manufacturer’s instruction cmplete all as specified and directed. Note :- The sheet shall be laid with one corrugation side lap and end lap minimum 150mm in slope all as per manufacturer's instructions as directed by GE
S&F Pre- painted galvaume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws of appropriate size as per manufacturer’s instruction cmplete all as specified and directed. Note :- The sheet shall be laid with side lap and end lap minimum 150mm as per manufacturer's instructions .or as directed by GE
M&L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 kg of cement per Sqm complete all as specified and directed.
M&L for machine cut kota stone slab as in flooring 20 to 25 mm of size 550 x 550 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone slab including grinding, rubbing and polishing to mirror finish with & including screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and directed
All as per item No.5 above 15 to 20 mm thick but prepolished kota stone as in riser of steps and skirtings / dado & including screed bed or bedding over 10 mm thick in CM 1:4 complete all as specified and directed.
M&L for providing PCC (cement concrete) 1:2:4, type B-1 (using 20 mm graded aggregates) as in bed plates coping, padding without using extra cement and smooth finish complete all as specified and directed
Demolition of brick or stone boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone works and precast concrete articles, complete all as specified and directed
M&L Brick work with sub class B bricks, old size, straight or curved on plan exc 6m mean radius built in CM 1:6 Complete all as Specified and directed
Taking down cement or cement lime plaster of any description including racking out joints, hacking for keys ,scrubbing down with water etc complete all as specified and directed.
M&L Rendering 15 mm thick in CM (1:4) on fair faces of brick work or concrete surfaces and finishing the surfaces fair and even complete all as specified and directed.
M&L for preparing surfaces plastered or unplastered new surfaces of wall and applying two coats of cement paint over a coat chalk whiting primer on plastered surfaces complete all as specified and directed.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
S&F anodized aluminum snap grid of size 605 x 605 mm frame work for false ceiling complete as specified in SSR part-I all as specified and directed.
M&L for 4 mm thick non asbestos fibre cement building boards fixed or laid / inserted to timber / GI / Aluminium frame work with screws complete all as specified and directed.
Taking down carefully existing unserviceable copper / aluminum point wiring of any description & in any position with and including taking out existing unserviceable conduits or battens of any description with sunken boxes/junction boxes and all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings, lamp holders etc but excluding light fittings and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed.
Material and labour for point wiring for one light point or one fan or bell point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, 1100 volts grade in and including concealed PVC conduit (Medium grade) of suitable size all as directed with using new sunken type pressed steel box / terminal boxes for mounting fittings/junction boxes not less than 1.6mm thick duly painted with two coats of black bituminous paint over a coat of red oxide primer with 3mm thick bakelitelaminated sheet, and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed.
All as per Srl item No 17 here in above but point wiring for 5/6 pin switch socket outlet, 5/6 Amps on independent board.omplete all as specified and directed.
All as per Srl item No 17 here in above but point wiring for 5/6 pin switch socket outlet, 5 Amps on same board with other switches omplete all as specified and directed.
All as per Srl item No 17 here in above but point wiring for one six pin socket outlet, 15 /16 Amps (independent) controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor omplete all as specified and directed. Notes for item 18 & 19 here in before : (i) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at RCC Columns/Beams/Ceilings shall be in surface conduit of suitable size fixed on surface with using PVC rawl plugs and provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick bakelitelaminated sheet fixed with suitable GI screws and cup washers) (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A' (iii) The size of conduits shall be determined on permissible No. of runs of wires as specified in SSR Part-I (2009) clause 19.125 (B). However minimum size of conduit shall be 20mm dia (Medium grade)
Supplying & fixing for piano switch flush type, 5/6 Amps, single pole, one way , 230 volts AC circuit complete all as specified & directed.
Supplying & fixing for piano switch flush type, 15/16 Amps, single pole, one way , 230 volts AC circuit complete all as specified & directed .
Supplying & fixing for socket outlet, five pin, 5/6 Amps, flush type, 230 volts AC circuit complete all as specified & directed .
Supplying & fixing for socket outlet, multipurpose, three pin, 15/16 Amps & three pin controlled by one switch , flush type, 230 volts AC circuit complete all as specified & directed.
Supplying & fixing for ceiling rose PVC Polycarbonate isolated body 63.5 x 25 mm, three terminals, complete all as specified & directed.
Supplying & fixing for lamp holder, insulated body with back plate suitable for batten fitting complete all as specified & directed.
Supply and fixing fan regulator electronic, step type, suitable for ceiling fans of any capacity, pre-wired 230 volts AC 50Hz supply 100Watt complete all as specified & directed.
Disconnecting and taking down old unserviceable sheet metal enclouser any size any type including MCB etc complete and Supply, fixing, connecting & testing sheet metal single pole and neutral enclosure with metal clad (two pin and earth) plug top and socket complete with and including one No MCB ( 'C' series), SP, 20 Amps, 240 Volts, having breaking capacity 10 KA complete all as specified and directed.
S&F in replacement 20 watt LED battan surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption < 20W, luminaire lumens > 2000 lms, system efficiency of > 120 lumens / W, LED of make : Nichia / Cree / Everlite / Eclison / OSRAM / Lumiled, with LED binding as per ANSJ Bin C78377A, Ingress protection IP 20, colour rendering index CRI > 80, temp range 0 to 45 ºC, driver efficiency > 85%, power facor > 0.95 THD < 20% as per IEC 61000-3-2, colour temp - 6500 K Surge protection 2.5 KV, 50000 burning hrs (min) as per L 70 criteria, two stages isolated constant current operated driver with range 150 - 270 VAC and safety extra low voltage safe level < 60 VDC as per IEC standard with LM 70 & 80 certification complete all as specified Make :- Wipro Model No.LL20-281 - XXX-65AL1 or equivalent of philips / Balaj / Jaquar
Supplying, fixing in replacement & testing ultra modern Rececess mounted luminaire with high brightness SMD LED's as light source for LED 34 watt, fixture size 595 x595 mm, LED environmental friendly, new generation,aesthetically designed a suitable for armstrong/grid ceiling complete ,internally prewired with and including accessories and connecting the same to electric source with using copper conductor 0.50 Sqmm flexible PVC sheathed and insulated three core copper conductor cable, including all accessories and fixing arrangements for fixing the light fitting to ceiling complete all as specified & directed. Cat part No : PLUTONEO2X2PLR34WLED857S of model PLUTO NEO PANEL 2x2 of make Havells and cat part of Wipro -LM-38-461-XXX-57-XX or equivalent model of specified make as approved by GE.
Disconnecting and taking out existing street light fitting of any type,any description and in any position on poles or fixed on walls complete and Supply & fix LED security light of 30 watt with aluminium pressure diecast housing, high purcity PC Fresnel diffuser with silicon gasket for IP 65 protection, power consumption < 30W & luminaire lumens > 2500 lumens/W and system efficiency > 125 lumens/W, in built electronic driver prewire upto terminal block with driver efficiency > 85 %, power factor > 0.95 suitable for enternal pole upto 35 mm, LED make :- Nichia / Cree / OSRAM/Everlite/Lumiled / Eclison, CRI > 70, suitable for ambient temp range of 0-50 ºC, THD <20% as per IEC 61000-3-2, colour temp 5700 K Surge protection 3.5 KV, 50000 burning hrs (min) as per L70 Criteria, multi stage constant current operated driver with range 150-270 VAC and safety exra low voltage safe load < 60 VDC as per IEC standards with LM 70 & 80 certification complete all as specified, fixed to pole or wall of buiding with and including suitable Bracket made out of 40 mm dia GI light grade pipe, 1.20 m long bent to shape by cutting & welding as required & directed and fixed with two Nos of FI clamps 50x6 mm to be tightened with suitabe size of bolts, nut and washers and including painted with two coat of aluminium paint over a coat of red oxide primer, and including connecting the fitting to electric source with & including twin twisted copper flexible wire of size 0.75 Sqmm including all accessories and fixing arrangements for fixing the light fitting complete all as specified & directed. Cat part No :- LR02-331-XXX-57-XX of Wipro or equivalent of Philips / Bajaj / Havells
Disconnecting and taking down old unserviceable distribution boards any size any type including MCB TPN/SPN/SP etc and making good the disturbed surfaces to match the existing surfaces complete all as specified and directed.
S&F in replacement of unserviceable MCB DB sheet metal enclosure triple pole and neutral 415 V with 200 Amps standard bus bar of suitable size and common neutral link and earth bar all enclosed on standard steel sheet flush mounting type double door factory fabricate complete without MCB and with encosure blank plates for unused way suitable for 4 way flush in wall complete all as specified and directed.
S&F in replacement of unserviceable MCB DB sheet metal enclosure factory fabricated door door SPN 8 way with 200 Amps rated bus bar 240 volt complete all as specified and directed
Supplying & fixing MCB TPN, 63 Amps (`C’ series ) having breaking capacity 10 KA, 415 volt complete all as specified and directed.
Supplying & fixing MCB SPN, 40 Amps (`C’ series ) having breaking capacity 10 KA, 240 volt complete all as specified and directed.
Supplying & fixing MCB SP single pole, 40 Amps (`C’ series ) having short circuit rating10 KA, 240 volt complete all as specified and directed.
Supplying & fixing MCB SP single pole, 6 to 32 Amps (`C’ series ) having short circuit rating10 KA, 240 volt complete all as specified and directed.
Disconnecting & taking up or down existing unserviceable sub main wiring of copper/aluminium conductor with two run of single core cable with one run of single core earth conductor cable of any description, any size & in any position including taking out existing unserviceable conduits or battens of any description and making good the disturbed surfaces to the existing surfaces all as specified and directed. (NOTE : Two run of single core PVC cable with one run of earth conductor and conduit /batten shall be measured as one unit.)
M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of dia not less than 20 mm with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor connected to earth dolly complete all as specified and directed.
M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of dia not less than 20 mm with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor connected to earth dolly complete all as specified and directed.
M&L in repair for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel wire 4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 15mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
Supply and laying or fixing or passing through pipe including taking out existing unserviceable cable and provn of 1100 volts grade heavy duty LT UG cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and overall PVC sheathed 4 core 25.0 Sqmm nominal cross section in service connections complete all as specified and directed.
Supplying and fixing of GI tubing, 50 mm bore, light grade as in sleeving/protection of cable etc laid in trenches/floor or fixed on pole / wall etc. with and including suitable size of MS clamp and nut, bolt ,washer etc complete all as specified and directed
Excavation in trenches in soft / loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. including removing of cable, protection covers/ bricks complete all as specified and directed Note : (i) Excavation shall be made carefully in order to avoid damage of existing cables and protection cover/Bricks . (ii) The excavation work may be carried out in short lengths for locating fault in under ground cables at different locations
Returning, filling in excavated soil including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed and tested complete all as specified and directed .
Removal of surplus excavated soils to a distance not exceeding 50 M and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for old size sub class `B` bricks, kiln burnt, as in cable protection laid flat with axis of brick perpendicular to the axis of the cable complete all as specified and directed .
Material & labour for sand filling with clean dry find sand unwashed including gently punning around under ground cables in trenches/ducts for cable protection with layers of sand ( 8 cm deep before laying cable and 15 cm after laying cable ) complete all as specified and directed at site.
Dismantling, takingdown ceiling fan any size with down rod keeping in safe custody for reuse and refixed with electrically connecting with and including flexible copper cord from ceiling rose to fan and testing complete all as specified and directed.
Guru Ji Aura
M/s J S & SONS
Apoorva Constrution
3Krishna Enterprises
deva engineers
Asha Construction
M/s Salim Mohomad
M/s Rahul Kumar Agrawal
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .