Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 LAdmitted-Finance | ₹3.1 L | L1 | Admitted-Finance |
| 2 | L2₹3.2 L+₹13,610 (4.37%)Admitted-Finance | ₹3.2 L+₹13,610 (4.37%) | L2 | Admitted-Finance |
| 3 | L3₹3.6 L+₹47,270 (15.2%)Admitted-Finance | ₹3.6 L+₹47,270 (15.2%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Bilal Electricals L1 | Ghulam Mohidin L3 | KHAN ELECTRICALS POWER AND SUPPLIERS L2 |
|---|---|---|---|---|---|---|
| 1.00Sub Station | ||||||
| 1.01 | 63 kVA ,11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound , and with LV Cable Box having detachable Aluminium Gland plate | 1 | No | 1,80,000 ₹1,80,000 | 1,90,000 ₹1,90,000 | 1,61,000 ₹1,61,000 Lowest |
| 1.02 | SITC of 9 Mtr. Long Pole,ST-410 SP33) including pit excuavation 1/6th of pole height | 2 | No's | 20,000 ₹40,000 | 19,000 ₹38,000 | 17,111 ₹34,222 Lowest |
| 1.03 | SITC of Galvanized Nuts & Bolts. | 8 | Kg's | 110 ₹880 Lowest | 150 ₹1,200 | 141 ₹1,128 |
| 1.04 | SITC of GI Channel Cross arms (100X50X6 mm) and (75X40X6 mm) , V Cross arms etc including transformer Belting, Clamps etc. fabricated out of Galvanised steel of different sizes to be fixed with G.I Nuts and bolts and washers including cross arms /Vcross and clamps etc . | 300 | Kg's | 100 ₹30,000 Lowest | 130 ₹39,000 | 137.7 ₹41,310 |
| 1.05 | SITC of Earthing of Sub-Station - Excavation of earth Pit of 650 mm dia. & depth 3000 mm,Installation of earthing Pipe of 40 mm nominal bore and 4 mm wall thickness and length 2.5 m long as per IS-1239.GI strip for neutral earthing of size 25mm x 3mm for connection of X-mer body,G.O set & LA as per IS-2629/85,Gi nuts and bolts refilled with earth enhancement materials & earth Chamber made of Brick masonary with RCC Slab Cover. | 3 | No's | 500 ₹1,500 Lowest | 1,500 ₹4,500 | 900 ₹2,700 |
| 1.06 | SITC of 11kV Gapeless Surge Arrestor ,9 kV,10 kA,LA with polymer housing station type with all accessories. | 1 | Set | 2,500 ₹2,500 Lowest | 6,000 ₹6,000 | 2,700 ₹2,700 |
| 1.07 | SITC of 11 kV G.O AB Switch 3-Phase,3-Pole of Capacity 200A Vertical type with arrangements for pad locks and operating rod. The operating rod should be G.I Pipe (B Class) of 25 mm dia of requisite length. | 1 | Set | 8,000 ₹8,000 Lowest | 8,000 ₹8,000 Lowest | 10,900 ₹10,900 |
| 1.08 | SITC of LT Distribution Box for 63 kVA DTR with 100 Amp MCCB 3P 16 kA for incomer & 100 Amp MCCB 3P 16 kA 1 No. and 63 Amp MCCB 3P 16 kA 1 No.s for Outgoing Circuits | 1 | No | 10,000 ₹10,000 Lowest | 20,000 ₹20,000 | 21,000 ₹21,000 |
| 1.09 | SITC of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm | 6 | No's | 200 ₹1,200 | 200 ₹1,200 | 190 ₹1,140 Lowest |
Tender Value
₹3.7 L
EMD Value
₹7,400
Closing Date
4 Jul 2026, 2:00 pmClosed
Executive Engineer ED Sumbal
Office of the Executive Engineer ED Sumbal Near Irrigation Colony Sumbal
Creation of 63 KVA Transformer at KAW Mohalla Bakerpora Boniyari Hajin under MPLADS
2026_PDD_311722_1
EDSbl 04 of 2026-27
Open Tender
Electrical Works
Turn-key
45 days
Sumbal
as per SBD Enclosed
6 documents required · 6 mandatory
₹200
Executive Engineer ED Sumbal
₹7,400
8 Jul 2026
6 Jun 2026
6 Jul 2026
6 Jun 2026
4 Jul 2026
8 Jun 2026
6 Jun 2026 - 8 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Sub Station | |||||
| 1.01 | 63 kVA ,11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound , and with LV Cable Box having detachable Aluminium Gland plate | - | No | 1.25 | - |
| 1.02 | SITC of 9 Mtr. Long Pole,ST-410 SP33) including pit excuavation 1/6th of pole height | - | No's | - | - |
| 1.03 | SITC of Galvanized Nuts & Bolts. | - | Kg's | 100 | - |
| 1.04 | SITC of GI Channel Cross arms (100X50X6 mm) and (75X40X6 mm) , V Cross arms etc including transformer Belting, Clamps etc. fabricated out of Galvanised steel of different sizes to be fixed with G.I Nuts and bolts and washers including cross arms /Vcross and clamps etc . | - | Kg's | 53 | - |
| 1.05 | SITC of Earthing of Sub-Station - Excavation of earth Pit of 650 mm dia. & depth 3000 mm,Installation of earthing Pipe of 40 mm nominal bore and 4 mm wall thickness and length 2.5 m long as per IS-1239.GI strip for neutral earthing of size 25mm x 3mm for connection of X-mer body,G.O set & LA as per IS-2629/85,Gi nuts and bolts refilled with earth enhancement materials & earth Chamber made of Brick masonary with RCC Slab Cover. | - | No's | 10 | - |
| 1.06 | SITC of 11kV Gapeless Surge Arrestor ,9 kV,10 kA,LA with polymer housing station type with all accessories. | - | Set | 11 | - |
| 1.07 | SITC of 11 kV G.O AB Switch 3-Phase,3-Pole of Capacity 200A Vertical type with arrangements for pad locks and operating rod. The operating rod should be G.I Pipe (B Class) of 25 mm dia of requisite length. | - | Set | 1.25 | - |
| 1.08 | SITC of LT Distribution Box for 63 kVA DTR with 100 Amp MCCB 3P 16 kA for incomer & 100 Amp MCCB 3P 16 kA 1 No. and 63 Amp MCCB 3P 16 kA 1 No.s for Outgoing Circuits | - | No | - | - |
| 1.09 | SITC of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm | - | No's | 100 | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.40 MB
SBD04.pdf
Tender Documents • 1.02 MB
Drawings.pdf
Other Document • 5.44 MB
Specifications.pdf
Additional Documents • 3.87 MB
BOQ_1009224.xls
BOQ • 0.30 MB
cor1.pdf
PDF • 0.71 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .