Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.2 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹14.8 L+₹2.4 L (19.6%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹16.0 L+₹3.6 L (28.9%)Rejected-Finance 58 CHANDRALOK BUILDING MAYO HOSPITAL ROAD NAGPUR 440 018 | NAGPUR | MAHARASHTRA | 440018 | L3 | Rejected-Finance Not Lowest |
| Sl No | Description | Qty | Unit | VIJ ASSOCIATES L2 | M/S. ELECTROPOWER TECHNOLOGIES L3 | MTR GROUP & COMPANY L1 |
|---|---|---|---|---|---|---|
| 1.00 | M & L for servicing of split type AC (Indoor/Outdoor unit) of any capacity by cleaning by vaccum cleaner of filter on front side including fins, checking of refrigerant standing pressure, topping of refrigerant upto the required level, complete all as specified and as directed.
Note : Refrigerant required for topping (R22 / R32/R410/R407C/R410a/ R134) shall be measured and paid separately as "supply only rates" under respective item. | 25 | Each Job | 995 ₹24,875 | 1,050 ₹26,250 | 500 ₹12,500 Lowest |
| 2.00 | M & L for servicing of window type AC of any capacity by cleaning by vaccum cleaner of filter on front side including fins, checking of refrigerant standing pressure, topping of refrigerant upto the required level, complete all as specified and as directed.
Note : Refrigerant required for topping (R22 / R32/R410/R407C/R410a/ R134) shall be measured and paid separately as "supply only rates" under respective item. | 10 | Each Job | 995 ₹9,950 | 1,050 ₹10,500 | 400 ₹4,000 Lowest |
| 3.00 | Supply only Refrigerant gas R 407C/410a in company sealed cylinder of capacity (Cylinders shall be return after use) complete all as specified and as directed. | 10 | Kg | 1,450 ₹14,500 | 1,475 ₹14,750 | 1,000 ₹10,000 Lowest |
| 4.00 | Supply only Refrigerant gas R-22/R-32 in company sealed cylinder of capacity (Cylinders shall be return after use) complete all as specified and as directed. | 10 | Kg | 1,450 ₹14,500 | 1,455 ₹14,550 | 1,200 ₹12,000 Lowest |
| 5.00 | Supply only Refrigerant gas R-134/R-290 in company sealed cylinder of capacity (Cylinders shall be return after use) complete all as specified and as directed. | 10 | Kg | 1,450 ₹14,500 | 1,500 ₹15,000 | 800 ₹8,000 Lowest |
| 6.00 | Supply only Box type relay suitable for Window type AC 1.5/2.0 ton capacity complete all as specified and as directed. | 1 | Each | 50 ₹50 Lowest | 70 ₹70 | 120 ₹120 |
| 7.00 | Supply only Thermostatic switch with knob suitable for window type AC 1.5/2.0 TR as per existing sample complete all as specified and as directed. | 4 | Each | 50 ₹200 Lowest | 70 ₹280 | 300 ₹1,200 |
| 8.00 | Supply only Blower Motor, single phase 230 Volts 1500 RPM, suitable for 1.5 TR Window type Air Conditioner complete all as specified and as directed. | 1 | Each | 3,500 ₹3,500 | 3,200 ₹3,200 | 2,500 ₹2,500 Lowest |
| 9.00 | Supply only Blower Motor, single phase 230 Volts 1500 RPM, suitable for 2.0 TR Split type Air Conditioner complete all as specified and as directed. | 1 | Each | 3,500 ₹3,500 | 3,250 ₹3,250 | 2,500 ₹2,500 Lowest |
| 10.00 | Supply only Blower Motor, single phase 230 Volts 1500 RPM, suitable for 1.5 TR Split type Air Conditioner complete all as specified and as directed. | 1 | Each | 3,500 ₹3,500 | 3,450 ₹3,450 | 2,000 ₹2,000 Lowest |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
10 Jan 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer
Military Engineer Services, Garrison Engineer, Cantt Area, Kamptee 441001
REPAIR / MAINT OF AIR CONDITIONG, DESERT COOLERS, REFRIGERATORS AT KAMPTEE, FORT AREA NAGPUR AND UNIT 371 UNDER GE KAMPTEE
2025_MES_745314_1
8861/E8
Open Tender
Civil Works
Item Rate
90 days
Kamptee
All as per NIT
8 documents required · 8 mandatory
₹500
GE Kamptee
₹30,000
Yes
10 Feb 2026
19 Dec 2025
12 Jan 2026
19 Dec 2025
10 Jan 2026
3 Jan 2026
M & L for servicing of split type AC (Indoor/Outdoor unit) of any capacity by cleaning by vaccum cleaner of filter on front side including fins, checking of refrigerant standing pressure, topping of refrigerant upto the required level, complete all as specified and as directed. Note : Refrigerant required for topping (R22 / R32/R410/R407C/R410a/ R134) shall be measured and paid separately as "supply only rates" under respective item.
Supply only Refrigerant gas R 407C/410a in company sealed cylinder of capacity (Cylinders shall be return after use) complete all as specified and as directed.
Supply only Box type relay suitable for Window type AC 1.5/2.0 ton capacity complete all as specified and as directed.
Supply only Blower Motor, single phase 230 Volts 1500 RPM, suitable for 2.0 TR Split type Air Conditioner complete all as specified and as directed.
Supply only Scroll complete with bush suitable for window/ split type AC complete all as specified and as directed.
Supply only Over load protector suitable air conditioner 1.5 ton capacity complete all as specified and as directed.
Supply only Sensor Ac Volt (Temp Sensor) of any type and any size of AC complete all as specified and as directed.
Supply only split type PVC AC cover for Outdoor Unit of any capacity complete all as specified and as directed.
Material and labour for replacement of copper tubing including cutting brazing, flaring and testing of size (1/2)"/(1/4)" x 22 SWG in required length including insulation of piping, complete all as specified and directed.
Dismantling/taking down unsv Split type air conditioner (Indoor/outdoor unit) of any capacity and any type from any place/height and re-install the same at other location including testing, complete all as specified and directed. (Repair work and replacement of damaged parts shall be measured separately).
Dismantling/taking down defective/unserviceable AC Outdoor unit from the site and installation with new indoor unit split type 1.5 TR complete with all connected items i.e copper tube cooling coil,PCB ,blower motor,filter and make complete all as specified and directed
S&F in repairs grass/wood wool cooling pad (set of three), minimum weight 0.8 Kg, fixed in side panels of desert coolers including GI wiremesh and mesh size 100 x 100 mm complete all as directed .
Supply only main transformer with super enameled copper wire proper insulated upto 5 KVA capacity for volatage stabilizer complete as specified and directed.
S&F in replacement of main PCB for voltage stabilizer 0.5 KVA to 5.0 KVA of approved make complete all as specified and directed.
S & F in repairs running capacitor (ISI Marked), 25-50 Mfd suitable for AC of capacity 2 TR. Complete all as directed.
S&F in relacement of cooling fan motor of indoor unit Split type AC of any capacity, Complete all as specified and directed
S&F in repairs Condensor Coil (1.0 Ton) of split/window type AC, complete all as specified and directed
Supply and fix Indoor PCB (Non inverter) for split type AC of capacity 1.5/2 TR of any make complete all as specified and directed
Supply and fix PCB for window type AC of capacity 1/1.5/2 TR of any make complete all as specified and directed
Material and labour for PVC Lead wire 4.0 sqmm stranded copper conductor 4 core (FRLSH) ISI Marked complete all as specified and as directed.
Material and labour for replacement of PVC drain pipe (Flexible) ISI Marked including clip and all fixing arrangements complete all as specified and as directed.
Material and labour for replacement of Capilary tube (copper) of any type of AC and any sizecomplete all as specified and as directed.
Supply and fixing in repair of compressor (sealed unit) with relay suitable for refrigerator of capacity of 165/175/195 Ltrs ltrs capacity complete all as specified and as directed.
Supply and replacement of Box type relay suitable for refrigerator 165 to 310 ltr capacity complete all as specified and as directed.
Supply and replacement of Magnetic door gasket for refrigerator 165 to 310 Ltrs capacity complete all as specified and as directed.
Supply only heavy duty stand for refrigerator 165 to 310 Ltrs capacity complete all as specified and as directed.
M&L for sub main wiring with two single core PVC FR LSH insulated unsheathed stranded copper conductor and earth wire 1100 volt grade and drawing into PVC conduit not less than 20 mm medium grade concealed in wall of the sizes 2x4 Sqmm with earth wire of 1x4 Sqmm including dismantling of old unsv submain wiring complete all as specified and directed.
s repairing of internal worn out wires, motor ,Pump, Fan vicket, Lead wire , switch regulator , PVC Pipe Name plate , and replacement of unserviceable parts including testing complete all as specified and as directed. (Note “ Spares required for Replacement shall be measured and paid separately as supply only in respective items)
Material and labour for Fan vickret Blade PVC/iron body with nut Bolt washer for 4000 cum/Hr Desert Cooler of various makes complete all as specified and as directed.
Supply and fix in repair switch piano flush button single pole one way 5 amps 240 volts with polycarbonate body all as specified and directed.
Supply and fix Plug top for desert cooler 3 pin 5 Amps, 230 Volt AC, ISI marked complete all as specified and as directed.
Material and labour for PVC flexible pipe (from vertical pump to distributer and distributer to panele ) 15mm dia for Desert cooler including 3 way distributor junction tee set complete all as specified and as directed.
Material and labour for Desert Cooler water tank suitable for 4000/60000 cum/hrs of desert coolers capacity of various size all as per existing complete all as specified and as directed.
Supply and installation of GI, Pre fabricated rectangular GI ducts, of 24 SWG, Glavanised Iron Sheet thickness 0.70 mm complete with MS flanges and bracing (as specified), necessary supports using thread rods (as directed) and anchor bolts, supply air collars, vanes, splitters complete all as specified and directed.
Material and labour for Repairs / Servicing of RO plant of any capacity including replacement of filters etc, PVC Pipe , and replacement of unserviceable parts including testing complete all as specified and as directed
M&L and T&P for disconnecting, taking down all connections and shifting, installing, testing and commissioning of Air Ducting coller of any capacity from one location to other location complete all as specified and directed Note: Cost of materials required for connecting, commissioning and testing shall be deemed to be included in quoted rate.
Supply & fixing in repair Ball valves for pipe size 20mm high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 210gms) and fixed ISI Marked approved quality including taking down old unsv valves,complete all as specified and directed.
S & F in repairs desert cooler body of size 60x55x65 cm made out of 20 gauge GI sheet & water storage tank of soze 65x55x20 cm deep made out of 18 gauge GI sheet including front grills & three side shutters duly fitted with wood pads & duly spray painted with two coats of synthetic enamel paint over a coat of red oxide primer (inside & outside) complete all as specified and as directed.
S & F in repair desert cooler fan motor 3 speed copper winding ISI mark including suitable leg set of three including nut bolt washer complete all as specified and as directed.
S & F wooden scantling second class hard wood of size 50X50 mm and making frame and fix with screw and nail for supporting to desert cooler complete all as specified and as directed.
S & F 3mm fibresheet 4x8 (polycarbonate material flame proof) with commercial face of 3 mm thick bwr grade for packing of AC and desert cooler,Complete all as specified and directed
M&L for replacement of Desert Cooler/Window AC stand of size 75 cm x 75 cm, hieght upto window cill with two flat iron with for legs (Drg to be provided by Engr-in-Charge) on made out of iron angle of size 50 mm including necessary bolting by fastners, complete all as specified and directed
Supply and replacement of wooden shelving pad for Air Ducting Cooler of size 6' x 6' x 6 feet with 4 Inch thick honeypad complete all as specified and directed.
Supply and installation in replacement of GI, Pre fabricated rectangular GI ducts of 24 SWG, Galvanised Iron Sheet thickness 0.70 mm complete with MS flanges and bracing (as specified), necessary supports using thread rods (as directed) and anchor bolts, supply air collars, vanes, splitters complete all as specified and directed.
Material and labour for making hole for AC pipe of size for 75/100 mm including grouting of PVC pipe of size 75/100 mm in wall, cutting chasing and plastering, painting etc, to match with the existing surface complete all as specified and directed.
Taking out & removing old existing plywood of any description and in any position and supplying and fixing new plywood 4mm thick, grade BWR, type BB, 3 ply, cut to size made to shape and fixed in position with nails as to make the window of desert cooler air tight complete all as specified and as directed.
Supply and fix in replacement Flame Retardant (FR) PVC casing caping of Size 3" (75 mm), Ivory/white Colour, Unplasticised formulation for prolong storage or usage, double lock, ISI Marked as per IS 14927, Highly durability, Resistance to oil an
All as per item No 23.00 above but for AC 1.5TR capacity split type complete all as specified and directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
Tenderdocument8861.pdf
Tender Documents • 0.77 MB
BOQ_834559.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .