Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.6 L+₹1.2 L (5.97%)Rejected-Finance GROUND BALURGHAT COMPOUND NEAR TRIPURA ROAD KHANAPARA ROAD GUWAHATI KAMRUP METROPOLITAN ASSAM 781029 | KAMRUP METRO | ASSAM | 781029 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹24.0 L+₹4.6 L (23.5%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
8 Jun 2020, 6:00 pmClosed
GE (N) Bikaner
GE (N) Bikaner Mil Stn Bikaner
Outsourcing of STP for DRDO Unit and allied works under GE (N) Bikaner
2020_MES_343633_1
GE (N) BKN-Token/14/2020-21
Open Tender
Miscellaneous Works
Item Rate
330 days
GE (N) Bikaner
Class E Category d (v)
8 documents required · 8 mandatory
₹500
GE (N) Bikaner
₹50,000
Yes
2 Mar 2021
9 May 2020
10 Jun 2020
9 May 2020
8 Jun 2020
24 May 2020
Amount
Schedule 'A' Section I (Note for item No.1 &2 : The rate quoted shall not be less than minimum wages as notified by Government of India/State Government/Local body whichever is higher . In case the rates quoted are less than the minimum wages as notified by the Government of India/State Government/Local body whichever is higher his tender will be treated as NON BONAFIDE and will not be considered for acceptance. In such case, the lowest tender shall be determined by the lowest amount amongst valid / bonofied bids only) Outsourcing of services for 260 KLD STP at Umrao Complex (DRDO Unit) with 01 FGM (Semi skilled ) in each shift for 3 shifts round the clock and one helper (un skilled) for one shift only will be employed by the contractor (each shift for 08 hours) all as directed by Engineer-in-Charge.
Outsourcing of services for 180 KLD STP at inside DRDO Unit restricted area with 01 FGM (Semi skilled ) in each shift for 3 shifts round the clock and one helper ( Un skilled) for one shift only will be employed by the contractor (each shift for 08 hours) all as directed by Engineer-in-Charge. Notes : For Item No 01 & 02 (i) Daily, weekly, monthly, quarterly, half yearly and annual maint to be carried out and keeping records thereof. (ii) Daily log sheet attendance register for persons employed by the contractor to be maintained. (iii) All types of T&P required for day to day maintenance shall be provided by the contractor. (iv) All types of transportation if reqd for handling materials/eqpts etc shall be provided by the contractor. (v) All types of fire eqpts provided in all the installations shall be maintained and operated properly. (vi) All electrical fitting and fixtures installed at STP installation to be maintained and contractor shall be responsible for any damage. (vii) All types of water tanks shall be maintained. (viii) All installations to be kept neat and clean all the time. (ix) In case of any damage, misuse, mishandling of Govt property, contractor will be held responsible for the same. (x) Chlorination of sewage water are to be carried out from the recognized lab i.e., C.O.D, B.O.D etc and record to be maintained. (xi) Treated water to be tested monthly from recognized lab and record to be maintained. (xii) Medical needs to be provided by the contractor to the employees as and when required. (xiii) First Aid Box with basic medicines to be kept in installation by the contractor. (xiv) Misuse of electricity and water to be penalised and effective recovery will be made by the department. (xv) Outsourcing of services shall start immediately after acceptance of work. (xvi) All garden, lawns, trees etc being planted in all the installations shall be maintained regularly and to be developed further as directed. (xvii) FGM should be ITI qualified or 02 years experience in the particular field. (xviii) Fuel for running of DG Sets of both STP's shall be supplied by the department and contractor shall responsible to collect the fuel from the department by his own arrangement. (xix) Entire area inside and outside of STPs shall be cleaned properly by the contractor and cost shall be deemed included in the quoted rate. (xx) All the FGMs & Helper shall be in proper dress code and shoes as approved by the GE.
Schedule 'A' Section II M & L for taking up incl dismantling, reassembling, transporting and lowering of submersible sewage pump of capacity 22.94 LPS Mtr head and 30 Mtr Cubic per hours discharge single stage all as specified and directed by Engineer-in-Charge. Make of pump: CG. Note :- Crane for taking up & lowering of submersible pump set while repairing/rewinding will be arranged by the contractor and the rent for the same is included in the item rate.
Supply & fixing in replacement of the following unserviceable spare parts of submersible pump as per existing make and size against item No 3 above :- (a) S/S Impeller.
(b) S/S Pump shaft (single stage)
(c) Hook bolt (Upper & lower)
(d) S/S neck ring
(e) Key for pump shaft (Each stage)
(f) Distance sleeve
(g) Suction chamber
Dismantling, transporting and reassembling of submersible motor after rewinding & replacement of worn out parts mentioned below incl rewinding of submersible sewage motor 7.5 HP of 03 Phase, 415 volts with PVC insulated solid copper conductor (wire) superior quality of approved make , size & number of wire as per existing specification complete all as specified and as directed by Engr-in-Charge.
Supply & fix in replacement of the following unserviceable spare parts of submersible sewage motor as per existing make and size against item No 5 above :- (a) GM Bearing Bush
(b) Rotor sleeve
(c) Water seal (KSB only)
(d) Cable seal
Dismantling of existing defective induction motor of 7.5 HP capacity, 03 phase, 415 volts 50 HZ and make from the foundation, disconnecting the electric connecting coupling pulley, and taking out to work shop cutting down and removing existing burnt out copper windings, cleaning of slots and rewinding with solid copper conductor (winding wire) complete including varnishing, drying, ovening, overhauling, greasing and fixing in the same position, making necessary electric connection and testing of induction motor complete all as specified and as directed by Engineer-in-Charge.
Same as per item 7 above but capacity 2 HP 03 phase, 415 volts 50 HZ
Same as per item 7 above but capacity 1.5 HP 03 phase, 415 volts 50 HZ
Supply & fix in replacement MCCB 100 Amp capacity triple pole breaking capacity 25 KA at 415 volts including making connections by using suitable size copper lugs/thimbles and crimping tool complete all as specified and directed by Engr in charge. Make: - L&T/Havells/Crompton greaves
Taking out/dismantling of unserviceable compressor cap 7.5 HP including replacement of wornout components such as bearing as per existing size, compressor oil, rubber seal, repair to pump including reassembling installation, connecting and testing etc complete all as specified and directed by Engineer-in-Charge.
(a) Supply and fixing in replacement. Ball Bearing No. 3307 of Make :SKF/NBC
(b) Supply and fixing in replacement. Ball Bearing No 6306 of make : SKF/NBC
(c ) Supply and fixing in replacement. Rubber Seal for 7.5 HP compressor
(d) Supply and fixing inreplacement fan belt for air blower, induction motor suitable for 7.5 HP motor as per sample all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of butter fly valve of size 100 mm bore. Make : BIR/Advance/Leader/Sant
Supply and fixing in replacement of butter fly valve of size 150 mm bore. Make : BIR/Advance/Leader/Sant
Supply and fixing in replacement of butter fly valve of size 80 mm bore. Make : BIR/Advance/Leader/Sant
Supply and fixing in replacement of butter fly valve of size 50 mm bore. Make : BIR/Advance/Leader/Sant
S&F in replacement MCB single pole, 240 volts of rating 6-32 Amps, breaking capacity of 10 KA complete all as specified and as directed by Engineer-in-Charge Make :- Schneider/ HPL/Legrand/ GE/ Seimens/L&T/Indo sian/C&S/Havells/BCH/ABB
S&F in replacement MCB suitable for 6 to 32 Amps, 240 Volt AC supply single pole and neutral with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge. Make :- Legrand/ GE/ Seimens/L&T/Indo Asian/C&S/ABB/BCH
S&F in replacement MCB suitable for 32 Amps, 415 Volt AC supply triple pole and neutral with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge. Make :- Legrand/ GE/ Seimens/L&T/Indo Asian/C&S/ABB/BCH
M&L in replacement air pressure gauge round type 0-150 Kg/cm2 make : Guru/ equivenlant
Supply only liquid chlorine (Sodium Hypochlorite at 12% to 16% ) all as directed by Engineer-in-Charge. Make- Chloromax/Shree Rayalaseema Hi-Strength Hypo Ltd Note :- (i) Sealed packed liquid chlorine container shall be supplied by the contractor on requirement basis at STP. (ii) Transportation incl labour charge will deemed in the item. (iii) The contractor ensure that liquid chlorine shall be kept for one month in advance at STP.
M&L in replacement of GI Pipe medium grade in trenches complete with fittings all as specified and directed by Engr-in-charge. Make : Jindal/TATA/Surya. (a) 150mm bore
(b) 100mm bore
(c) 80mm bore
(d) 50mm bore
(e) 40mm bore
( f) 25mm bore
(g) 20 mm bore
Supply and fixing in replacement gun metal globe or gate valve ISI marked with iron wheel head screwed both ends for iron pipe complete all as specified :- (a) of size 80mm
(b) of size 50mm
(c) of size 40mm
(d) of size 25mm
(e) of size 20 mm
S&F detachable joint complete with rubber ring and necessary nut,bolts and washers suitable for CI/GI pipe line complete all as specified and directed by Engr-in-charge :- (a) 150mm bore
(b) 100mm bore
Supply and fixing in replacement of the following spare parts of panels contactor MNX 9 Amp (Make : L&T/C&F/Legrand)
Supply and fixing in replacement of the following spare parts of panels contactor MNX 18 - 25 Amp (Make : L&T/C&F/Legrand)
Supply and fixing in replacement of the following spare parts of panels contactor MNX 50 Amp (Make : L&T/C&F/Legrand)
Supply and fixing in replacement of Relay MN-2 as per sample
Taking out of UNSV analogue Amp meter and supply and fix new digital ebrit panel mounted AC ammeter (0-300A) of size 96 X 96 sqmm flush mounted case three phase, calss 0.5 item code PAMEBRITA 32. Make:-AE/HPL
Taking down UNSV phase indicator lamp supply and fix new phase indicator lamp (red, yellow & blue)
Taking out of UNSV analogue volt meter and supply and fix new digital ebrit panel mounted AC volt meter (0-500A) of size 96 X 96 sqmm flush mounted case three phase, calss 0.5 item code PAMEBRITA 32. Make:-AE/HPL
S&F electronic type single phasing preventer in existing panel boards (max 600v min 380v) three phase 415volts variation voltage 4% tripping time 2-5 sec max type VSP-1 complete all as directed by Engr in charge. Make:- L&T/Minilac/Siemens.
Supply and fix in replacement star delta timer range 0-30 second Make : C&S/L&T /Schiender
Supply and fixing in replacement of connector as per sample
Supply and fixing in replacement of panel lock as per sample
Supply and fixing in replacement gland packing graphite and grease coated suitable for pump sets of size 4mm / 6mm
Supply only multi grade sand / pebbles for Duel media filter comprising of sizes as under :- (a) Anthracite upto (480mm) - 02 Qtl (b) Filtering sand 16/32 (800mm) - 3.18 Cum (c) Fine Silex (160mm) - 0.65 Cum (d) Coarse Silex (160 mm) - 0.65 Cum (e) 6-2 Crushed Gravels (160mm) - 0.65 Cum (f) 20-12 Pebbles (160mm) - 0.65Cum (g) 40-25 pebbles (160mm) - 0.65 Cum
Supply only multi grade sand / pebbles for Duel media filter comprising of sizes as under :- (a) Activated cobon (900mm) - 02 tones (b) Fine Silex (100mm) - 1 tones (c) Coarse Silex (100mm) - 13 tones (d) 6-2 Crushed Gravels (100mm) - 01 tones (e) 20-12 Pebbles (160mm) - 01 tones (f) 40-25 pebbles (160mm) - 01 tones
Labour only for taking out as directed and filling new sand, graavels, and otthrer filter media from dry sludge bed of sewage treatment plants complete all as specified and directed. (Note- Complete set of 6 beds)
Pumping out and removing of sewage water / mud from the aeration tank, and maturation tank and wet well using suitable dewatering pump / non clog sewage pump or manually and disposed off out side the MD land by means of closed portable tanks etc complete all as directed by the Engineer-in-charge
Dismantling opening and reassembling after repair /replacement of U/S spare parts of mono block pumping set capacity 7.5 HP spare parts required shall be measured and paid separately. Job includes disconnection from base foundation frame disconnecting electrically, reconnection, re-fixing in position transportation to work shop & back make of pump :- Kirlosker
Supply only the following spare parts for mono block pump of 7.5 HP capacity (a) Gland bush
(b) Gasket set manifold
Description all as per item No 42 but of cap 5.5 HP spare parts shall be measured and paid separately
Supply only the following spare parts for monoblock pump of cap 5.5 HP (a) Gland Bush
(b) Gasket set manifold
All as per item No – 44 but capacity 3 HP spare parts required shall be measured and paid Separately
Supply only the following spare parts for mono block pump of 3 HP capacity Make:- Kirloskar (a) Gland bush
(b) Gasket set manifold
All as per item No – 41 but capacity 1 HP spare parts required shall be measured and paid Separately
Supply only the following spare parts for mono block pump of 1 HP capacity Make:- Kirloskar (a) Gland bush
(b) Gasket set manifold
M/S SHREE SHYAM TRADERS
Goyal Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .