| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.4 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹50.6 L+₹1.3 L (2.60%)Rejected-Finance 5 127 16 GANESH GARDEN KADAMPADI SULUR COIMBATORE TAMILNADU 641401 | COIMBATORE | TAMIL NADU | 641401 | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹50.7 L+₹1.3 L (2.71%)Rejected-Finance | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹51.7 L+₹2.3 L (4.73%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹52.2 L+₹2.8 L (5.76%)Rejected-Finance | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
29 Jul 2020, 6:00 pmClosed
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
REPAIR MAINT TO SUNKEN FLOOR TREATMENT BROKEN JOINERY FLOORING AND OTHER MISC B R WORKS AT AFS SULUR
2020_MES_359678_1
8327/E8
Open Tender
Miscellaneous Works
Item Rate
210 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹98,000
Yes
4 Aug 2020
9 Jul 2020
30 Jul 2020
9 Jul 2020
29 Jul 2020
23 Jul 2020
9 Jul 2020 - 22 Jul 2020
Amount
Treatment of the sunken floor slab comprises of the following specification and all as specified Make :- Dr Fixit/ M/s Sika india Pvt Ltd/ STP Ltd/ M/s Fosroc Chemicals
(a) Demolition of cement concrete filling of any description in sunken portion in toilet and removing debris outside MD land.
(b) Cleaning the sunken/ lowered portion of RCC slab surfaces (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding conc to achieve proper sploe including cutting holes in bricks or RCC wall for spout (WPC shall be measured and paid separately)
(c) Rendering of uneven surfaces with 10mm thick CM 1:4 mixed with integral water proofing compound @ 3% by wt of cement consumed. Fill it with water and check dampness and seepage. Where dampness/ seepage is noticed, nozzles shall be fixed and grouting carried out. (WPC shall be measured and paid separately).
(d) All junctions points of side wall where CI/ GI pipes are passing through shall be sealed with epoxy putty.
(e) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean.
(f) M&L for applying two coats of polymer modified cementious water proof coating as per manufactures instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed (This item shall be pleasured and paid separately)
(g) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound 3% by wt of cement consumed as per manufacturers specification including rounding of corners and junctions sloping towards spout. (WPC shall be measured & paid separately).
(h) PCC 1:5:10 type E2, complete all as specified
(j) PCC 1:2:4 type B0 40mm thick, complete all as specified
Note :- Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage, seepage and to the entire satisfaction of GE. Test shall be done in presence of reps of Engineer-in-Charge and record for each sunken slab shall be maintained. The treatment shall be carried out by authorised applicators of chemicals. Cost of testing is include in the rates quoted above.
PVC (SWR) 75mm junction vent cowl including taken down existing one complete all as specified and as directed by Engineer-in-Charge
PVC (SWR) 75mm junction (single T) equal or unequal provided with access door including taken down existing one complete all as specified and as directed by Engineer-in-Charge
PVC (SWR) pipes single socketed in any length with rubber ring joints of 110 mm bore fixed to wall including taken down existing one complete all as specified and as directed by Engineer-in-Charge
PVC (SWR) branch piece single (sing Y) 75mm equal or unequal provided with access door including taking down existing one complete all as specified and as directed by Engineer-in-Charge
PVC bends 75mm bore including taken down existing one complete all as specified and as directed by Engineer-in-Charge
Repair of leakage/seepage from the Nahani trap/ floor trap of kitchen/ bathroom/ washbasin of the upper Qtr, in any position at any height, complete including change of floor trap, PVC horinzontal pipe embeded in floor in bathroom or kitchen making good to the damage portion of flooring, laying and matching of tiles in the existing flooring, complete all as specified and directed by Engineer-in-Charge
Repair of leakage/seepage from the wall/ door bend /door tee/ 'Y' junction/ 'T' Junction of soil pipe / waste pipe/ vent pipe of kitchen/ bathroom/WC of the upper Qtr or at the ground floor Qtr including change of any damage soil waste pipes or fittings of any shape, specification and size, making good to the damage portion of wall with brick work in cement mortar 1:6 or cement concrete 1:2:4 and plastering to wall in CM 1:4 and matching to existing wall complete to avoid the leakage/ seepage at the site of work as directed and specifie by the Engineer -in- charge
Note for item No 18 & 19 :- (a) Find out main cause of leakage and take necessary steps to resolve / rectify. (b) Replace existing tiles in case lakage through NT/FT. (c) The rate also include provision of new NT/FT. (d) The unit rate is also deemed to be included for reqd bonding chemicals to arrest the leakage/seepage as direct by the manufacturere specification. Make : M/s Sika Chemical, M/s Pidilite, M/s Dr Fixit
Glazed ceramic coloured tiles 450 x 300 mm x 7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles on vertical surface such as dado, laid over and including backing coat with cement mortar 10 mm thick in CM 1:3 complete complete all as specified and directed. Note : The Unit rate is demend to be included for : (a) Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. (b) The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation/fixing
Vitreous china squatting pan 'Orissa' Pattern size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe ) including provision of lime concrete bedding fixed in repairs
S&F in repairs, 300mm of size, 5mm thick corner glass shelf with stainless steel brackets, stainless steel railing in bathroom and fixed to wall with brackets including removing the existing fitting, complete all as specified as per manufacturer's instructions and as required at site complete all as specified and as directed
CP sink cock with swinging casted round shape spout screwed down screwed for iron pipe in repairs 15mm bore CAT Part No-CQT-23347 Jaquar or equivalent in Parryware ,or as per list of makes including taken down existing one complete all as specified and as directed by Engineer-in-Charge
Pre painted Coloured Galvalume roofing system sheet 0.50 mm thick having Zinc aluminum alloy coating AZ150 shall be as per IS:277/ASTM 1379 150 gsm/ sqm double ribbed trapezoidal profile steel sheet any colour having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws, including dismantling of roof sheet any type complete all as directed.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified
Note for Pre-painted coloured Galvalume roofing :-
(i) The manufacturer's test certificate and individual test certificate for the chemical and mechanical properties of sheet must be submitted for approval by the concerned authority prior to installation.
(ii) The contractor shall ensured that no leakages take place from the roof. The roofing shall be Coloured Galvalume roofing system (olive green colour or as approved by GE) with feed material manufactured from 0.50 mm Total coated thickness (TCT), minimum 550 MPa yield strength and shall conform to the physical specifications of IS: 2062 of 2011, coated with hot dip metallic Aluminium / Zinc alloy coating AZ150 as 150 gm/sq.mt total on both sides.
(iii) The painting shall be coloured baked enamel polyester with silicon coating of film thickness 25 microns nominal on the exposed face/exterior side and on the reverse side ( interior face) shall be white with 15 microns film thickness, over a coat of 5 micron nominal thickness Primer.
(iv) The contractor shall produce purchase vouchers for each lot for verification of Engineer-in-Charge.
Framed work such as grills, gratings, angles etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of static water tanks and similar work con- forming to Fe.290. Gde-E-165 including dismantling wrought iron or mild steel work of any description not otherwise provided for fencing/ watch tower having height 30m complete all as specified
Factory made UPVC three track sliding Window frame having 2 tracks for glass shutter and 1 track for mosquito sash made of upvc profile section of size 73mm x 42mm (wxh) having outer wall thickness of 2.0mm(+/-0.2mm). Sliding glass shutter shall be made of UPVC section of size 55mm x 33mm and sliding wire mesh shutter shall be made of UPVC section of size 40mm x 22mm. All section of the frame, sash, transom & mullion, as applicable, shall be duly reinforced with G/J/U/O shape galvanised mild steel section of required thickness considering structural / wind load requirement. System shall be provided with the suitable upvc bead for glazing of the system & fitted with inner & outer EPDM seal gaskets. Clear Glass of Saint Gobain / Modiguard make with thickness of 4mm and stainless steel wire cloth of 0.19mm nominal dia. All welded joints are to be neatly trimmed & feature grooved/raised nib finish so make the finished product free from all sharp edges & burrs. All the corner / mullion / transom joints of the frame and sash shall be mitered cut & fusion welded without any mechanical joining. System shall have adequate drainage mechanism to permit the escape of water from horizontal member beneath each sealed unit. System is to be provided with proper operating & locking hardware mechanism. Window locking system will be either both side push lock system or semi-circle locking system in centre. Complete window shall be fixed in to the existing pre finished aperture, by drilling and fixing through the outer frame using quality fasteners & silicon glue is applied to fill up the crevice between wall and window frame for leak proof installation including taking existing one complete all as specified. Note: - The contractor will have to submit 5 years warranty certificate for upvc profile and 1 year warranty certificate for hardwares.
100 mm thick plain cement concrete type D-2, 1:4:8 (40mm graded aggregate) including demolition of existing concrete and disposal out side MD land as directed by Engineer-in-Charge.
Vitrified Ceramic tiles 10 mm thick, dark shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as in for skirting/dado. etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer ,10 mm thick in Cement Mortar 1:3 including taking down existing tile and removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. Note : (a) Vitrified tiles are classified under group B1a of the international Standard for ceramic tiles ISO: 13006. Tiles shall be hard, dense, impervious and frost resistant. Water absorption of tiles shall be less than 0.5% and flexural strength (Modulus of Rupture) shall be more than 35 N/Sqmm. (b) The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation.
6mm thick frame less bevelled edge mirror fixed with steel stud as per direction of Engineeer in -charge including taken down existing one .
WHB, vetreous china (flate back or angle back type) of size 500x400mm including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe Complete including taken down existing one
CP Hand shower (Health Faucet) with 1M Flexible tube with 8mm dia wall hook with NRV (Back flow preventor) in repair CAT Part No ALD CHR-579 Jaquar or equivalent in Parryware, Cera
12mm thick toughened glass for doors including polished by machine on edges including stainless steel clips/hinges, stainless handles (02 Nos), floor spring double action including taking down existing glass complete all as specified and as directed by Engr-in-Charge (Make : Saint Gobin/ESG/Modi)
Joint free non skid coloured ceramic tiles 7 mm to 8mm thick (Square/rectangular) area of each tile exceeding 0.16 Sqm but n exc 0.18 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles , laid over and including cement screed bed 15 mm thick in CM 1:4 complete Note : The Unit rate is demend to be included for : (a) Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. (b) The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation/fixing
Black Granite slab 18 to 20mm thick machine cut, pre-polished , bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite including cutting a hole in the granite slab for gas pipe etc to any shape and polishing of exposed edges in cooking platform complete all as required site (Overall size of the slab shall be measured) complete. The size of slab shall be single piece and exposed edges shall be moulded including taken down existing one complete all as specified and as directed by Engineer-in-Charge Note :- The unit rate is deemed to be included for dismantling of stone slab and tiles laid bedded and pointed in any mortar of any description or thickness in floors
Factory made UPVC Ventilators design will be like top part fixed with exhaust fan provision and bottom part with fixed louver strips.Ventilators frame made of upvc profile section of size 45mm x 43mm (wxh) having outer wall thickness of 2.0mm(+/-0.2mm). Wherever required /specified, system shall have the fix mullion of size 45mm x 60mm having outer wall thickness of 2.0mm(+/- 0.2mm). All section of the frame,transom & mullion shall be duly reinforced with G/J/U/O shape galvanised mild steel section of required thickness considering structural / wind load requirement. System shall be provided with the suitable upvc bead for glazing of the system & fitted with inner & outer EPDM seal gaskets. Pinhead Glass with thickness of 4mm required for fixed & louvers strips. All welded joints are to be neatly trimmed & feature grooved/raised nib finish so make the finished product free from all sharp edges & burrs. All the corner / mullion / transom joints of the frame shall be mitered cut & fusion welded without any mechanical joining. System shall have adequate drainage mechanism to permit the escape of water from horizontal member beneath each sealed unit. System is to be provided with proper operating & locking hardware mechanism. Complete ventilator shall be fixed in to the existing pre finished aperture, by drilling and fixing through the outer frame using quality fasteners & silicon glue is applied to fill up the crevice between wall and ventilator frame for leak proof installation including taking existing one complete all as specified. Note :- The contractor will have to submit 5 years warranty certificate for upvc profile and 1 year warranty certificate for hardwares.
Chequered cement concrete tiles 30cmx30cmx25mm thick machine pressed set jointed and pointed in neat cement slurry as in floors and cut and polished using gray cement and pigments over screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:4) including taking down existing tile any type/ description as directed The manufacturer's test certificate and individual test certificate of Tiles must be submitted for approval by the concerned authority prior to installation.
PVC bends 110mm bore including taking down existing one complete all as specified and as directed by Engineer-in-Charge
PVC (SWR) 110mm junction (single T) equal or unequal provided with access door including taken down existing one
PVC (SWR) 110mm dia P Trap including taken down existing one complete all as specified and as directed by Engineer-in-Charge
PVC (SWR) 110mm dia S Trap including taken down existing one complete all as specified and as directed by Engineer-in-Charge
WHB short padestal 570x400 mm white with spring& bolt set including taken down existing one complete.( Make : Cat No 0493 Niagara series of Parryware or euivalent series in Jaguar/Hindware)
Vitrified Ceramic tiles 10 mm thick, dark shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer, 15 mm thick in Cement Mortar 1:6 including taking down existing tile and removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. Note : (a) Vitrified tiles are classified under group B1a of the international Standard for ceramic tiles ISO: 13006. Tiles shall be hard, dense, impervious and frost resistant. Water absorption of tiles shall be less than 0.5% and flexural strength (Modulus of Rupture) shall be more than 35 N/Sqmm. (b) The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation/fixing
12mm thick toughened glasss frameless partition, with option of swing and sliding doors with all necessary to patch fittings and bottom insert like corner connection and side connector adn bottom insert to the floor about 15 to 30mm or done with aluminium profile 12mm depth including taking down existing glass complete all as specified and as directed by Engr-in-Charge (Make : Saint Gobin/ESG/Modi) Location : Officer's Mess
Niagara coupled closet with flushing cistern and anti microbial seat cover with all fittings including taken down existing one complete (Make : Cat No C0262 Niagara series of Parriware or euivalant series in Jaguar/Hindware)
Removing plant/Uprooting of vegetation growth including roots on wall/roof/parapet near pipes etc and applying acid treatment after removing roots for preventing regrowth and making good disturbed surfaces/area in superficial area exc 150sq.cm but n.exc 400 sq.cm and averaging depth not exceeding 10 cm by using PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) or 10mm thick plastering in cement mortar 1:3 as required and finishing the surfaces to match with the existing surface complete all as specified and directed. Note: (a) Rate quoted by the tenderer shall be deemed to inclusive of double steel scaffolding. (b) Contractor shall provided safety gears to his workers at his own cost and safety pre caution to avoid accidents.
PVC (SWR) 110mm junction vent cowl all as specifed including taken down existing one complete all as specified and as directed by Engineer-in-Charge
PVC (SWR) pipes single socketed in any length with rubber ring joints of 75 mm bore fixed to wall including taking down existing one complete all as specified and as directed by Engineer-in-Charge
CAK Enterprises
p.chinnasamy
SENTOOR BUILDERSS
SRI VIGNESH ENTERPRISES
KRISHNA ENTERPRISES
NAVEEN ENTERPRISES
The Asian and Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .