| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 LAccepted-AOC E 140 2010 BKP VILL AMTALLA PO DUMARCHIR DIST PAKUR PIN 814111 JHARKHAND | PAKUR | PAKUR | JHARKHAND | 814111 | L1 | Accepted-AOC REASONABLE | |
| 2 | L2₹9.7 L+₹1.0 L (11.6%)Rejected-Finance | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹9.8 L+₹1.1 L (13.0%)Rejected-Finance 337 B ROAD NO 04 ASHOK NAGAR RANCHI 834002 JHARKHAND | RANCHI | JHARKHAND | 834002 | L3 | Rejected-Finance HIGH RATE |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
30 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I AF SINGARSI
AGE I AF SINGARSI
Repairs Maint of Cooling appliences Deep freezers Fridge ACs voltage steblizer including MCB at AF Stn Singarsi under AGE I AF Singarsi
2021_MES_480256_1
C/8530/E8
Open Tender
Civil Works
Item Rate
180 days
AGE I AF SINGARSI
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
AGE I AF SINGARSI
₹16,000
Yes
4 Dec 2021
7 Oct 2021
1 Nov 2021
8 Oct 2021
30 Oct 2021
15 Oct 2021
45 days
Amount
Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants , regulators, sockets etc excluding light fitting for taking credit removing from site and making good disturbed surface of walls, floors etc.
M & L for point wiring with FR PVC insulated unsheathed multistranded copper conductor cables of 1.5 sqmm size alongwith one earth continuity conductor with PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm size through and including PVC casing & caping on PVC switch board for fixing of switches, sockets, fan regulators etc
All as per item No 2 but one 3/5 pin socket outlet, 5 Amp independent
All as per item No 2 but one 3/5 pin socket outlet, 5 Amp on the same board with other switches
M & L for point wiring with FR grade PVC insulated unsheathed multistranded copper conductor cables of 4 sqmm size alongwith one earth continuity conductor with PVC insulated unsheathed multistranded copper conductor cable of 4 sqmm size through and including PVC casing & caping on PVC switch board for fixing of switches/ sockets for one 3 pin socket outlet, 15 Amps, independent
M & L for point wiring with FR grade PVC insulated unsheathed multistranded copper conductor cables of 4 sqmm size alongwith one earth continuity conductor with PVC insulated unsheathed multistranded copper conductor cable of 4 sqmm size through and including PVC conduit terminated in modular switch boards for fixing of switches/ sockets for one 3 pin socket outlet, 15 Amps, independent
S & F Switch piano, flush type single pole, one way 5 Amp
S & F Socket outlet 2 in 1, 3 pin, 5/6 Amp
S & F Switch socket combination 2 in 1, 5/6 Amp flushl type
S & F Switch socket combination 5A/ 16A, 5 in 1 flush type
S & F in replacement of Modular Switch 1 way 6 A, 1 module
S & F in replacement of S & F Modular Switch 1 way 16 A, 1 module
S & F in replacement of S & F Modular Socket 6 A, 2/3 pin combined 2 module
S & F in replacement of S & F Modular Socket 6 A/ 16 A, 2/3 pin combined 2 module
S & F in replacement of S & F Modular Fan step regulator, 120 watt, 2 module
S & F in replacement Modular Bell push 6A, 1 module
S & F stepped type electronic fan regulator flush type
S & F Ceiling rose, 3 terminal PVC insulated body
M&L for dismantling the window type AC of capacity in 1.5/2 Ton in various location, shifting it to MES Yard for repair/replacement of unserviceable spares and servicing, cleaning of filter (if not replaced) of window type AC of any capacity by vacuum cleaner/water spray/mild liquid soap cleaning the front grill by soft cleanser (Colin etc) and painting the outer cabinet by enamel paint and sticking a sticker mentioning the ‘MES No, and reassembling, testing, checking and shifted to existing location, fixing the same by thermocol, ply wood, wooden bit all as directed & specified by Engineer-in-Charge. Including replacing of starting capacitor, running capacitor, relay , thermostate, and capillary tube (NOTE: The spare parts Including replacing of starting capacitor, running capacitor, over load protection relay , compressor, condensing coil etc measured & paid separately).
Supply & Fix new compressor sealed unit of suitable capacity / model in the unit properly for 1.5 TR window type AC all as specified and directed by Engr-in-Charge.
Supply & Fix new compressor sealed unit of suitable capacity / model in the unit properly for 2 TR window type AC all as specified and directed by Engr-in-Charge.
S&F for cooling coil unit for window type AC of any type all as specified and directed by Engr-in-Charge.
S&F for overload protection for window type AC 1.5 Ton capacity.
M&L for runner made of aluminium suitable and operation knob for window type AC 1.5 ton capacity including taking out old unserviceable runner.
Taking out complete exhaust air fan motor uter unit for AC window type 1.5 ton capacity for rewiring with suitable size multi stranded copper cable including testing, checking etc complete.
S&F for replacement of PVC air filter for window type AC of 1.5 ton capacity including taking out old unserviceable air filter.
S&F for capacitor for blower motor suitable for window type AC 1.5 ton capacity including taking out old unserviceable capacitor.
S&F for fan blade for blower motor suitable for window type AC 1.5 ton capacity including taking out old unserviceable fan blade.
S&F for fan blade of exhaust air motor of window type AC of any capacity including taking down old unserviceable fan blade all as specified and directed by Engr-in-charge.
S&F for front grill for window type AC 1.5 ton capacity as directed by Engr-in-charge including taking out old unserviceable front grill.
S&F for swinging motor with louvers suitable make for window type AC 1.5 ton capacity including taking out old unserviceable swinging motor.
S&F for PCB for control unit for window type Ac 1.5 ton capacity as per existing.
Supply only remote control unit for window type AC 1.5 / 2.0 ton capacity.
M&L for dismantling the split type AC including indoor/outdoor unit of capacity 1.5 Ton/2 Ton in various location, shifting to MES Yard for repair/replacement of unserviceable spares and servicing, cleaning of filter (if not replaced) of window type AC of any capacity by vacuum cleaner/water spray/mild liquid soap cleaning the front grill by soft cleanser (Colin etc) and painting the outer cabinet by enamel paint and sticking a sticker mentioning “the MES Number and reassembling, testing, checking and shifted to existing location/new location as directed, fixing the same by nut, bolt, angle iron structure and masonry work all as directed & specified by Engineer-in-Charge. (NOTE: The spare parts Including replacing of starting capacitor, running capacitor, over load protection relay , compressor, condensing coil measured & paid separately).
Supply & Fix new compressor seal unit of suitable capacity/model in the unit properly for 1.5 TR split type AC all as specified and directed by Engr-in-charge.
Supply & Fix new compressor seal unit of suitable capacity/model in the unit properly for 2 TR split type AC all as specified and directed by Engr-in-charge.
Supply & charge of refrigerant gas R-22/R-140a/R-32
Supply & charge of refrigerant gas 134A.
Supply & charge of refrigerant gas HYDRO CARBON.
M&L for replacement of capillary tube and stainer for split AC of 1.5 ton/2.0 ton capacity.
Supply only copper condensing coil unit for split type AC 1.5 / 2.0 ton capacities all as specified and directed by Engr-in-charge.
S&F for copper cooling coil unit for split type AC of any type all as directed by Engr-in-charge including taking out old unserviceable cooling coil unit.
S&F for capacitor for blower motor suitable for split type AC 1.5 ton capacity including taking out old unserviceable capacitor.
S&F for copper pipe 5/8" / 1/2" / 3/8" / 1/4" dia (as per existing one) for connection indoor and out door unit.
S&F for PVC insulated PVC sheathed 1.5 Sqmm, 3 core copper cable 1100 Volts confirming to IS. (Make : KDK/Nicco/Finolex/Havells)
S&F for PVC insulated PVC sheathed 2.5 Sqmm, 3 core copper cable 1100 Volts confirming to IS. (Make : Nicco/Finolex/Havells)
S&F for swinging motor of split type AC 1.5/2 TR with louvers as pr existing out old unserviceable swinging motor with louvers.
S&F for fan blade for blower motor suitable for split AC 1.5 ton / 2.0 ton capacity including taking out old unserviceable blade.
S&F for fan blade for outdoor unit of split type AC of any capacity including taking down old one all as directed by Engr-in-charge.
S&F for LCD / LED display unit for split type AC 1.5 / 2.0 ton capacity including taking out old unserviceable unit.
S&F for replacement of PVC air filter for AC split type 1.5 / 2.0 ton capacity.
S&F for PCB for control unit for split type AC 1.5 / 2.0 ton capacity as per existing and same make.
Supply only remote control unit for split type AC 1.5 / 2.0 ton capacity as per existing and same make.
M&L for dismantling of storage type refrigerator of 165/310 ltrs capacity in various location, shifting it to MES yard for repair/replacement of unserviceable spares and painting the outer body (including replacement of corroded sheet with new one) by spraying enamel paint and sticking a sticker mentioning the “MES Number, testing, checking and shifted to existing location including masonry work all as directed & specified by Engineer-in-Charge.including replacement of relay, thermostate material keeping tray , chiller tray freezer door (indoor) metalic door rubber (NOTE: The spare parts ( ie compressor, cooling unit etc ) measured and paid separately)
Supply & Fix new compressor seal unit of 165 ltrs capacity of existing model in the unit properly for domestic refrigerator of any type all as specified and directed by Engr-in-charge.
Supply & Fix new compressor seal unit of 310 ltrs capacity of existing model in the unit properly for domestic refrigerator of any type all as specified and directed by Engr-in-charge.
M&L for replacement of capillary tube complete and stainer for any type and capacity of domestic refrigerator.
S&F for timer/bimetallic relay of existing type for domestic refrigerator all as specified and directed by Engr-in-charge.
Taking down of unserviceable voltage stablizer of capacity 3 KVA/3.15 KVA/5 KVA in various location for repair/replacement of unserviceable parts, cleaning, servicing, checking, reassembling, testing and handed over to MES in serviceable condition all as specified and directed by Engr-in-Charge including replacement of timer relay, relay up to 5 KVA capacity.
Supply and Fixing inreplacement of voltage Stabilizer for 1.5 Ton AC, 12 amps rated capacity (Working Range: 170V-270V) cut off 165 VAC(Minimum)- 270 Volt (Max) regulated output voltage & capacity ,Built in thermal overload protection, Low & High Voltage cut off, Time Delay: ITDS 3Min ±20 sec with ABS Cabinet Material . Make V Guard VG 400 or equiavalent
Supply and Fixing inreplacement of voltage Stabilizer for 2 Ton AC, 15 amps rated capacity (Working Range: 170V-270V) cut off 165 VAC(Minimum)- 270 Volt (Max) regulated output voltage & capacity ,Built in thermal overload protection, Low & High Voltage cut off, Time Delay: ITDS 3Min ±20 sec with ABS Cabinet Material . Make V Guard VG 500 or equiavalent
Electro Builders
Excel Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .