Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.5 LAccepted-AOC PHYANG LEH | LEH LADAKH | LADAKH | 194101 | L1 | Accepted-AOC Found lowest one bidder | |
| 2 | L2₹28.9 L+₹3.6 L (14.4%)Rejected-AOC STAKMO | L2 | Rejected-AOC Quoted high rate as compared to L1 | |
| 3 | Not Admitted-Finance | - | Not Admitted-Finance Others-Withdraw of tender bids | |
| 4 | Not Admitted-Finance | - | Not Admitted-Finance Others-withdraw of my tender bids |
Tender Value
₹17.5 L
Closing Date
7 Jan 2022, 2:00 pmClosed
Executive Engineer
Rural Engineering Wing Leh
Completion of remaining works at Chubi Yangtse community hall near Lamdon Model School Leh
2021_RDD_5555_2
NIT 116 UTLeh REW of 2021-22
Open Tender
Civil Works - Others
Item Rate
60 days
Leh
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Yes
Executive Engineer
Exempted
27 Jan 2022
30 Dec 2021
10 Jan 2022
30 Dec 2021
7 Jan 2022
30 Dec 2021
Amount
Providing and fixing PARQUET wooden flooring (ready made )composite size 16"x48"x12mm using 2mm thick thermacole inclusing cutting placing in position all complete job under the directions of engineer incharge
Providing and fixing 12mm thick prelaminated particle boardflat pressed three layer or graded wood particle board (conforming to IS: 12823 Grade-l type-11) in panelling fixed in aluminium doors, windows shutters and partition frames with C. P. brass I stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.Pre-laminated particle board with decorative lamination on both sides.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber I neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item.) With float glass panes of 5.50 mm thickness (weight not less than 13 .. 50 kg I sqm)
Wiring for light point fan /exhauaust fan/ call bell point /6amp socket with 1.5sqm PVC.FR insulated copper conductor single core in surface /recessed medium class PVC conduct suitable size m.s box and earthing the point with 0.75 sqm FR PVC insulated copper conductor single core cable required
wiring for 16 Amp socket outlet with 2.5mm FR PVC insulated copper conductor cable in existing recesses PVC conduct including sheet as required
supplying and drawing circuit wire for light and 6/16 amp socket outlet with 4.0sqm FR PVC insulated copper conductor single core cable in recessed /surface PVC conduct pipe as required
supply and fixing of 25mm PVC conduit capping along with accessories in surface recessed including cutting the wall and manly good the same in case of recessed conduct as required
supply and fixing 10amp 240 volt single pole grid plate mounted switch indicator with molded copper plate including recessed conduct as required
Supply and fixing of combined 3 pin 240 volt 10amp socket outlet with safety shutter and 10amp 240 volt single pole mounted in recessed including M.S box complete as required.
Supply and fixing of combined 3 pin 240 volt 20amp socket outlet with safety shutter and 20amp 240 volt single pole mounted in recessed including M.S box complete as requird
Supply and fixing of following single pole and neutral sheet steel MCB distribution board 240 volt on surface recess complete with tinned busbar neutral link earth bar, tin bar, detachable glaud plates, double door interconnected including pointing etc as required 16 way double door SPN.
Supply and fixing of the following light fixtures including all accessories like electronic ballasts coms etc, complete as required concealed/Tube lightning 20 watt 3000k, round LED Luminaries as per Philips
Supply of 1100 volt grade aluminium conductor KPLE insulated PVC sheath arranged complete as per specification as required 25 sqmm, 3.5 core
Wiring for changeover 63 amp and installtion with complete accessories and holes on the wall as required.
Supply and fixing of miniature circuit breaker of following poles in the existing MCB DB completed with connections testing and commissioning etc, as required.A) Single pole 6/10/20 Amp
Supply and fixing of miniature circuit breaker of following poles in the existing MCB DB completed with connections testing and commissioning etc, as required.B) Double pole 40 Amp
Supply and fixing of miniature circuit breaker of following poles in the existing MCB DB completed with connections testing and commissioning etc, as required.C) Double pole 63 Amp
Providing and fixing ceiling fan of approved brand philips, crompton,havels etc. complete job
3 modular plate
6 modular plate
12 modular plate
supply and fixing outdoor fash light 300W LED of phillips havels including 2.5mm wire and switch and complete job under the directions of engineer incharge
supply and fixing of stage light of 200W LED par light of brand phillips havels including 2.5mm wire and switch all complete job under the directions of enginner in charge
Supply and installation pf solar light with following conditions i) Recommended light level for public area with dark surroundings 20-25 lux i.e lumens/m2. ii)Solar street lightening system type integrated including single LED luminaries battery solar panel charge controllers ,sensors, pole fixing and mounting accessories . iii)Luminaries mounty height for recommended light level i.e pole height 6mtrs iv) Lay out for solar street light installations single side or staggered sided v) Recommended distance between street light 25mtrs. vi) Type of luminarie LED vii)Recommended wattage of luminare for recommended light level 25W-30W design100 luminaire . viii) Lumen cut put at source 3000 lumins. ix) Battery type n capacity lithumion integrated with luminaire 30 AH or higher . x) Solar panel capacity 75W or for luminaire capacity. xi) Solar charge controller ratting 5A or as per capacity. xii)pole specification mild steel pole with weather proof coating . xiii) Recommended sensors dush to dawn sensor and dimming . xiv) Working temperature -25degree C-To 60 degree C xv) Civil works earth work and cement concrete in 1:2:4mix (1 cement :2 coarse sand 4 stone 20 mm nominal size) (number of street lightening system be installed at various places
M/S RIGZEN NORBOO GOVT CONTRACTOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .