Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹33.4 L+₹2.6 L (8.45%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹36.1 L+₹5.3 L (17.1%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹38.2 L+₹7.4 L (24.1%)Rejected-Finance | L4 | Rejected-Finance Other than L1 |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
17 Aug 2021, 6:00 pmClosed
GE SATWARI
GE SATWARI
REPAIR MAINT OF DG SETS SIGN BOARD AND CONNECTED ITEMS AND CLEANING AND PAINTING OF OH TANK REPAIR OF VALVE PIT CHAMBER UNDER AGE E M MH OF GE SATWARI
2021_MES_459848_1
GEJM-41/2021-22
Open Tender
Civil Works
Item Rate
270 days
GE SATWARI
D Class Cat b i
9 documents required · 9 mandatory
₹500
GE SATWARI
₹82,000
Yes
19 Jan 2022
15 Jul 2021
19 Aug 2021
15 Jul 2021
17 Aug 2021
4 Aug 2021
Amount
Material and labour for Routine servicing of DG Set capacity 40 KVA Make: Kirloskar including drain out the unsv engine oil and taking out the fuel filter,oil filter,air filter with gasket from the engine. Poring the engine oil as per requreiment by the manufacture. replacement the fuel filter -02 Nos. Oil filter-01 Nos with gaskit making good any leakage of the engine oil Testing & commisioning. Note :-(1)Engine oil,Diesel filter -02 Nos,oil filter with Gaskit will be replaced in every 200 Hrs or 6 month whichever is earlier (2) cost of Engine oil,Diesel filter-02 Nos ,oil filter with gaskit to be including in item rate. No extra cost will be paid.(3) Air filter will be replaced after second servicing & same will be measured and paid separtely.
Dittp all as per srl item No 1 but of cap 63 KVA DG Set of Make Kirloskar, 4 cylinder, diesel filter-02 Nos, Oil filter-02 Nos, pre filter-01 Nos, Air filter -01 Nos
Ditto all as per srl item No 1 but of capacity 325 KVA DG Set of Make Greaves, 12 cylinder, Diesel filter-02 Nos, Oil filter-02 Nos, By pass filter-01 Nos, pre filter-01 Nos, Air filter-02 Nos
Ditto all as per srl item No 1 but of capacity 400 KVA DG Set of Make Greaves, 12 cylinder, Diesel filter-02 Nos, Oil filter-02 Nos, By pass filter-01 Nos, pre filter-01 Nos, Air filter-02 Nos
Ditto all as per srl item No 1 but of capacity 500 KVA DG Set of Make Cummins,12 cylinder, Diesel filter-02 Nos, Oil filter-02 Nos, By pass filter-01 Nos water filter-01 Nos, Air filter(External+internal)-01 Nos
Ditto all as per srl item No 1 but of capacity 625 KVA DG Set of Make Cummins,12 cylinder, Diesel filter-02 Nos, Oil filter-03 Nos, By pass filter-01 Nos water filter-01 Nos, Air filter(External+internal)-01 Nos
Taking out the FIP from the Engine & sent to workshop for overhauling & calibration of FIP 40/63 KVA DG Set ,4 cylinder Make-Kirloskar with replacement of worn out part i.e plunger,rotating valve,copper washers,O rings which ever requried and warnishing. after overhauling & calibration of FIP. FIP return back to site for refixing the original position testing & commisioning complete. (b) Taking out the injector from the Engine and send to workshop for overhauling & calibration. calibration of the injector including replacement of the Nozzle -04 Nos.after calibration , injector send to the site for refixing the original position (c) repair the pety pump including replacement of washers.
Dismantling, opening and cleaning of complete radiator assembly of following DG Sets, checking of water leakage, including upper and bottom tank cleaning of slots including welding/brazing where required and making 100 % leak proof and washing with chemically anti corrosion /water solution by using jet pumping set and as well as cleaning manually by using steel wire brushes and removing all rust ,silt /corrosive material and making good smooth functioning and upper &bottom tank gasket set,all rusted nut ,bolt ,washer ,radiator caps etc complete all as specified and directed by Engineer-in-Charge. (a) 325 KVA DG Set of Make Greaves
(b) 400 KVA DG Set of Make Greaves
M & L for dismantling the defective charging Alternator of 12 Volt DC, cleaning with cleaning agent, over hauling, and replacement of worn out parts i.e bearing of any description,field coil, which ever requried for functioning of alternator. 40/63 KVA DG Set
M & L for dismantling the defective charging Alternator of 24 Volt DC, cleaning with cleaning agent, over hauling, and replacement of worn out parts i.e bearing of any description,field coil, which ever requried for functioning of alternator. 315/400 KVA DG Set
M&L for disconnecting and dismantling the UNSV 12 Volt self starter assembly by removing the all bolts and nuts and disconnecting from DG sets, opening of self starter,overhauling of self starter, replacement of worn out bearing,bushes , field coil etc reconnecting testing and commissioning complete all as specified and directed by Engr-in-Charge. 40/ 63 KVA DG Set
M&L for disconnecting and dismantling the UNSV 24 Volt self starter assembly by removing the all bolts and nuts and disconnecting from DG sets, opening of self starter,overhauling of self starter, replacement of worn out bearing,bushes , field coil etc reconnecting testing and commissioning complete all as specified and directed by Engr-in-Charge. 400 KVA DG Set of Make Greaves
Supply & replacement of rotating rectifier diode assembly for the following DG Sets 325 KVA DG Set of Make Greaves
M & L for Replacement of following components/ spares suitable for 325 KVA DG Set, Engine Make-Greaves, all as per specified and directed by Engineer-in-Charge. Air Filter
Cogged V-Belt A-52
Cogged Belt for radiator
M & L for Replacement of following components/ spares suitable for 400 KVA DG Set, Engine Make-Greaves, all as per specified and directed by Engineer-in-Charge. (a) Air Filter
(b) Cogged V-Belt A-52
(c) Cogged Belt for radiator
(d) Ammeter for Battery charging
(e) Start and Stop push Button
(f) Voltmeter 0-500 V analog type Make AE/L&T
(g) Ammeter 0-500 Amps with suitable CTs ratio. Analog type Make ; AE/L&T
(h) Frequency Meter analog type . Make AE/L&T
(j) RPM meter 0-2500 RPM analog type
M & L for Replacement of following components/ spares suitable for 500 KVA DG Set, Engine Make-Cummines, all as per specified and directed by Engineer-in-Charge. (a) Air Filter( External+internal type) as per Exisiting
(b) COGGED BELT for dynamo
(c) V BELT COGGED for radiator
M & L for Replacement of following components/ spares suitable for 625 KVA DG Set, Engine Make-Cummines, all as per specified and directed by Engineer-in-Charge. (a) Air Filter( External+internal type) as per Exisiting
(b) COGGED BELT for dynamo
(c) V BELT COGGED for radiator
M&L for replacement of Air filter as per exiting make of capacity 40/63 KVA DG set
M & L for replacement of UNSV batteries of 180 AH, 12 volts (Make: EXIDE POWER /Amron/AMCO)
M & L for replacement of UNSV batteries of 150 AH, 12 volts (Make: EXIDE POWER /Amron/AMCO)
M & L for replacement of UNSV batteries of 92 AH, 12 volts (Make: EXIDE POWER /Amron/AMCO)
Supply and replacement of battery lead heavy duty of copper conductor standard red for (+ive) terminal and black for (-ive) terminal with battery terminal of one end and battery lugs at other end complete .
Supply & replacement of battery terminal clamps made up of brass heavy duty with nuts and bolts complete
Servicing / routine maintenance of ACB in AMF panel for 500 KVA DG set Make: ABB, Model AH-8D-CS of capacity 800 Amp checking of fastener,checking of shock absorber for leakage,checking of top and bottom trip free mechanisam,closing and tripping spring assy & spit pin,spring cut off micro switches.,earth fault relays ,under voltage relays all as specifed. Note: Replacement of any spare part will be measured and paid separately
Servicing / routine maintenance of ACB in AMF panel for 625 KVA DG set Make: ABB, Model AH-8D-CS of capacity 1000 Amp checking of fastener,checking of shock absorber for leakage,checking of top and bottom trip free mechanisam,closing and tripping spring assy & spit pin,spring cut off micro switches.,earth fault relays ,under voltage relays Note: Replacement of any spare part will be measured and paid separately
(a) Supply and fixing of Charging motors 220 V AC
(b) Earth fault relay for 6D-16D/08N-20S of Cat part No is EFR1164P C&S
(c) Closing coil (6D-16D/08N-206(AHA) Cat Part No CS-AVH-C-1 C&S
(d) Shunt Trip 6D-16/08N-20S(AHA) C&S
( e) Single phase polyester resin cast CTs for '' AH/AHA'' ACB for thermal release 8D/08N(AHA) 800/5A
(f) Compact UVT Coil 6D-16D/08N-20S(AHA) Cat part No is CS-AUH-V-A. C&S
(g) Auxiliary switch of type 14 way (7NO+7NC) 6D-16D/08N-20S(AHA) Cat part No is CS-AXH-7A7B-1 C&S
(h) Supply and fixing of Charging motors 220 V AC
(i) Supply and fixing main moving contacts Assembly
De-silting & cleaning of sewage treatment plant sump of cap 0.425 MLD complete with taking out water mixed with sludge & solid sludge etc removing and depositing out of cantt area in a covered container .and servicing STP Plant ,and proper functioning of STP all as specified and directed. Note :- The cleaning of the following parts like pit , chamber, sump and drain including (a) Coarse bar screen pit -01 nos (b) Receving sump -01 nos ( c) Silting chamber- 02 nos (d) Fine bar screen pit -02 Nos.(e) Sludge drying bed and (f) Main out going drain of length 50 mtr
De-silting & cleaning of sewage treatment plant sump of cap 100 KLD complete with taking out water mixed with sludge & solid sludge etc removing and depositing out of cantt area in a covered container .and servicing STP Plant ,and proper functioning of STP all as specified and directed. Note :- The cleaning of the following parts like pit , chamber, sump and drain including (a) Coarse bar screen pit -01 nos (b) Receving sump -01 nos ( c) Silting chamber- 02 nos (d) Fine bar screen pit -02 Nos.(e) Sludge drying bed and (f) Main out going drain of length 50 mtr
M&L for disconnecting 6/7.5 HP non clog submersible pumpset sewage type from the sewage sump and transporting to workshop for repair, cutting of burnt winding/cleaning of stator for rewinding with PVC insulated copper wire of existing size , providing with insulating materials, flame proof/water proof laminated insulated strips, cotton tape, complete and shifting back to site, coupling to pump and lowering in sump and testing all as specified and directed by Engr-in-charge.
M&L for disconnecting 15 HP non clog Raw water sewage transfer submersible pump from the sewage sump and transporting to workshop for repair, cutting of burnt winding/cleaning of stator for rewinding with PVC insulated copper wire of existing size , providing with insulating materials, flame proof/water proof laminated insulated strips, cotton tape, complete and shifting back to site, coupling to pump and lowering in sump and testing all as specified and directed by Engr-in-charge.
Cutting of wild grass ,bushes ,unwanted vegetation trees upto 30cm grith including roots from inside/surrounding of installations including cutting of bushes along barbed/cattle fencing of the installation comlete all as specified and directed by Engr-in-charge.
M&L Servicing of LT panel of STP by replacement of contractor, over load relay, over voltage/under voltage protection relay of existing make and suitable capacity, replacement of indictor lamp and control wiring of LT Panel complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement PVC insulated and PVC sheathed flat submersible cable 16 sqmm 3 core with stranded copper conductor 1100 volts grade suitable for submersible motors and pumps and making electric connections all as specified and directed. Make Polycab/Finolex/Havells
M&L for Replacement the defactive part of submersible pump sets are as under:- (a) Thrust bearing of non clog submersible motor 15 HP
(b) Gun metal bushes for non clog submersible motor 15 HP
(c) Impellers for non clog submersible pump 15 HP
(d) Bowl bush for non clog submersible pump 15 HP
(e) Neck ring for non clog submersible pump 15 HP
M&L for disconnecting 5.5 KW blower motor and transporting to workshop for repair, cutting of burnt winding/cleaning of stator for rewinding with super enamelled copper wire of existing size , providing with insulating materials, flame proof/water proof laminated insulated strips, cotton tape, complete and shifting back to site, coupling to blower fan and testing all as specified and directed by Engr-in-charge.
M&L for dismantling of 7.5 HP air blower pump from the electric motor and re-assembling the fan on existing foundation complete with motor after repair/overhaulding with following and testing complete all as specified and directed.The cost of transportation to and fro workshop is deemed to be included in the quoted rate. a) Replacement of blade. b) Cleaning, dusting and spray painting of air blower with motor (complete body) externally. c) Re-metaling/turning, greasing, oiling of pump shaft. d) Replacement of oil, oil seal, bearing, filter. e) Replacement of belts and pressure gauge.
M&L for servicing of air blower pump and motor 15/20 HP inclding overhaulding, adjustment of safty valve, replacement of belts, oiling, grasing, Cleaning, dusting and spray painting of air blower with motor (complete body) externally and testing complete all as specified and directed.
M&L for dismantling and de-coupling 20HP air blower pump from the electric motor and re-assembling the pump on existing foundation complete with motor after repair/overhaulding with following and testing complete all as specified and directed.The cost of transportation to and fro workshop is deemed to be included in the quoted rate. a) Adjustment of safety valve. b) Replacement of spring assy . c) Re-metaling/turning of pump shaft. d) Replacement of oil ENKLO 320, oil seal, bearing, filter. e) Replacement of belts ,& pressure gauge.
M&L in replacement of single plase preventor AC 440 volt complete as directed by Engr-in-charge.
M&L in replacement of contactor 3 pole with coil voltage 220 volt type MNX 50 Rating complete as directed by Engr-in-charge.
M&L for taking out old unsv MS Pipe of size 150 mm and replacement the same on appropriate size complete and testing all as specified and directed by Engr-in-charge.
All as per Srl item No 68 here in before but size of 100 mm bore.
Supply, laying in replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium conductor, Armoured conforming to IS-7098 Part-I (1988) with latest ammendments of size 400 Sqmm x 3.5 core. (MAKE :Havells, Finolex, Gloster) Note:- Earthwork/excavation shall be measured seperately
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for laying of pipes etc not exc 10 Sqm on plan and not exc 1.5m in depth and getting out in soft loose soil all as specified and directed.
Returning filling in, trenches including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in any type of soil complete all as specified.
Removing excavated surplus materials to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point.
Supply and spreading sand Dry cushioning to cable providing with a layer of sand 8cm deep before laying the cable and 15cm deep after laying and stretching the cable in trenches complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid.
S & F battery charger having electronic Circuit consisting of tridodes, rectifiers, capacitors, resistances etc suitable to be mounted on control panel to charge the battery of the DG Set at all times whenever there is electric supply either on mains or DG Set complete all as specified.
M&L for replacement of MCCB 3 pole thermal magnetic type cap 63 Amps,415 volt,50Hz of Breaking capacity 16 KA, including necessary modification in existing panel as required at site and connecting up complete. Make: Cat Part No of Legrand 6253 19 or equivelent in Hager/Schnider
M&L for replacement of MCCB 3 pole thermal magnetic type cap 100 Amps,415 volt,50Hz of Breaking capacity 16 KA, including necessary modification in existing panel as required at site and connecting up complete.. Cat Part No of Legrand 6253 20 or equivelent in Hager/Schnider
M&L for replacement of MCCB 3 pole thermal magnetic type cap 125 Amps,415 volt,50Hz of Breaking capacity 16 KA, including necessary modification in existing panel as required at site and connecting up complete.. Cat Part No of Legrand 6253 21 or equivelent in Hager/Schnider
M&L for replacement of MCCB 4 pole thermal magnetic type cap 160 Amps,415 volt,50Hz of Breaking capacity 36 KA, including necessary modification in existing panel as required at site and connecting up complete. Cat Part No of Legrand 0252 35 or equivelent in Hager/Schnider
M&L for replacement of MCCB 4 pole thermal magnetic type cap 200 Amps,415 volt,50Hz of Breaking capacity 36 KA, including necessary modification in existing panel as required at site and connecting up complete. Cat Part No of Legrand 0252 37 or equivelent in Hager/Schnider
M&L for replacement of MCCB 4 pole thermal magnetic type cap 250 Amps,415 volt,50Hz of Breaking capacity 36 KA, including necessary modification in existing panel as required at site and connecting up complete. Cat Part No of Legrand 0252 36 or equivelent in Hager/Schnider
M&L for replacement of MCCB 4 pole thermal magnetic type cap 630 Amps,415 volt,50Hz of Breaking capacity 50 KA, including necessary modification in existing panel as required at site and connecting up complete.
M&L for replacement of MCCB 4 pole thermal magnetic type cap 400 Amps,415 volt,50Hz of Breaking capacity 36 KA, including necessary modification in existing panel as required at site and connecting up complete. Cat Part No of Legrand 0255 38 or equivelent in Hager/Schnider
Supply and fix digital weekly time switch with LCD display along with its enclosure AC 220-240 V and necessary electrical conection in existing circuit with programable OFF/ON function all as specified and directed. Make: Havells Cat No. DHTJW01016 or its equivalent in L&T, C&S
Supply and fix 2.5 sqmm 5 core copper conductor cable PVC sheathed for high mast light connection all as specified and directed.
Material and labour in replacement of GATE TOP LIGHT MONACO decorative LED 3000K 10W fixture, aluminium die casting, transperent glass diffuser, black colour IP-43 complete inluding fixing using metal sleeve anchor fastners and bolts of suitable size and quantity to be fixed in concrete all as specified. Make-PHILIPS/CROMPTON GREAVES/JAQUAR
Material and labour in replacement of POLE LIGHT MONACO decorative LED 3000K 20W fixture, aluminium die casting, transperent glass diffuser, black colour IP-43 complete inluding fixing using metal sleeve anchor fastners and bolts of suitable size and quantity to be fixed in PCC block of size 45x45x60cm all as specified. Note : Rate of PCC will be inclusive in the quoted rates and nothing extra will be admission on this account. Make : Jaquar Cat Part No 340.PE8.NGG or equivalent in Crompton/Phillips
M&L for taking out complete DG set with canopy of Cap 63 KVA from existing position including taking out necessary electric and Earthing connection and refixing of same after repair of exiting flooring all as specified and directed
Material and labour for prepare of Soling (or sub base) with broken boulders or quarried stone, inter stices filled, surface formed and rolled and consolidated to required gradient and camber of thickenss 100 mm all as specified and directed.
Material and labour for plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in floors,foundations filling and mass concrete.complete and all as specified directed by engr-in-charge.
M&L for Framed work of steel structure GDE Fe410-0 or Fe 310-Oas in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled or weilded for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete and all as specified directed by engr-in-charge.
S&F chainlink fencing PVC coated green coloured 4mm dia galvanised steel wire, 150x100mm mesh, made up into mattresses or cages, lapped, wired and laid in position, including closing after filling complete all as specified and directed by Engr-in-Charge.
Brick work with old size brick curved or straight on plan exceeding 6m area radius built in CM 1.6 bricks crushing strength not less than 75 kg/square cm.complete and all as specified directed by Engr-in-Charge.
Material and labour rendering 10 mm thick on fair of brick surface in cement mortar 1:4 finished even and fair complete all as specified.
M&L for preparing newly plastered surfaces of wall and applying two coats of cement basecement base paint over a coat of white wash.complete and all as specified directed by engr-in-charge.
M&L hardcore of broken stone of gauge exc 63mm & n.exc 100mm deposited spread and leveled in layers n.exc 15cm thick watered and well rammed to a true surface. complete and all as specified directed by Engr-in-Charge.
M&L for PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate as in sub base of floor 75mm thick finished even and fair without using extra cement complete and all as specified directed by Engr-in-Charge.
M&L painting with synthetic enamel paint two coats over a coat of red oxide primer including preparing the new untreated steel surfaces of any description over 10cm in width or girth.complete and all as specified directed by Engr-in-Charge.
Material and labour for removing of deposited scales from inside the Over head reservoir of capacity 1.0 lakhs gallons with the help of wire brush and pressure pump of pressure not less than 50 to 80 bar, from the overhead tank and white washing the inner surface of the tank all as directed.
Description all as per Srl item No 100 here in before but for reservoir 0.5 lakh gallons capacity.
Description all as per Srl item No 100 here in before but for reservoir 0.1 lakh gallons capacity.
Material and labour for scrubbing the walls of over head reservoir from outer surface with iron brushes and cleaning the wall of 1.0 Lakh gallons cap all as directed and removing the dust/soil material and preparing the surfaces for colour washing and applying two coats of cement based paint on the outer surface of the tank and staging with providing two coats of enamelled paint on the CI/ MS pipes and rails and grills all as specified and directed.
Description all as per Srl item No 103 here in before but for 0.5 lakh gallons capacity.
Description all as per Srl item No 103 here in before but for 0.1 lakh gallons capacity.
Material and labour for painting and writing letters "SAVE WATER" in Black letter size 36"X18" on dome of over head water RCC tank, writing of tank capacity and date of cleaning and due date of cleaning in capital letters of 80 mm size on external surface of wall with white enamel paint over black background of 1.0 lakh gallons capacity over head tank all as directed.
Description all as per Srl item No 106 here in before but for 0.5 lakh gallons capacity.
Description all as per Srl item No 106 here in before but for 0.1 lakh gallons capacity.
Supply and fixing in replacement Cast iron Non return valve (NRV) 200 mm bore complete conforming to IS 1969 double flanged and drilled including bolts, nuts, washers, gasket etc complete and dismantling of old one complete all as specified and directed.
Supply and fixing in replacement Cast iron Non return valve (NRV) 250 mm bore complete conforming to IS 1969 double flanged and drilled including bolts, nuts, washers, gasket etc complete and dismantling of old one complete all as specified and directed.
Supply and fixing in replacement cast iron body sluice valve heavy duty class PN 1.6 flanged ends any pattern with cast iron wheel & mild steel spindle ISI marked confirming to IS-14846 of 2000 for 80mm bore pipe with jointing material, flanged joint, rubber gasket 6mm thick, nuts & bolts, washer complete all as specified and directed.
Description all as per Srl item No 111 here in before but 100mm bore pipe.
Description all as per Srl item No 111 here in before but 150mm bore pipe.
Material and labour for run lead joint including all jointing material such as lead, spun yarn etc for 80mm bore cast iron spigot & socketed pipe & fittings. (Exc earth work will be measured & paid separetely)
Description all as per Srl item No 114 here in before but for 100mm bore cast iron spigot & socketed pipe & fittings.
Description all as per Srl item No 114 here in before but for 150mm bore cast iron spigot & socketed pipe & fittings.
Material and labour for construction of one brick masonary valve pit built in cement mortar 1:6 of size 120cm x 120cm x120 cm (internal dimension) over 15cm thick PCC 1:3:6 type C-2 sub base extended alround 15cm beyond external edge of brick work including plastering 15mm thick in cement mortar 1:4 internally and plus pointing to brick wall surfaces externally as work proceeds complete with MS sheet cover 3.15 mm thick with handle and locking arrangement, angle iron frame 40mm x 40mm x 6mm (grouting with anchor fashioners length not less than 15cm - 04 Nos) and painting with a coat of synthatic enamel paint over a coat of red oxide, complete all as specified and directed.
Description all as per Srl item No 117 here in before but of size 100cm x 100cm x 100cm (internal dimension).
S&F manhole covers / valve pit covers fabricated out of MS sheet, MS flat and angle iron of required sizes or shapes required at site and painting with one coat of black synthetic enamel paint over a coat of red oxide primer including taking out / dismantling rusted or unserviceable covers of UG sump/OHT/valve pits, etc. and disposing off complete all as specified and as directed
M&L for old painted or treated / untreated steel or iron surfaces of any description like valve pit covers, pipe lines of OHT, rising/delivery/washout pipes, etc. over 10cm in width or girth and applying two coats of synthetic enamel paint (of existing colour and as directed) over a coat of red oxide zinc chrome primer including staging to work at approx 17ft heights complete all as specified and as directed
M&L for cleaning, descaling of valve pit chamber, bailing out the leakage water and filling the gland packing and rubber pacing in sluice valves, etc. complete all as specified and as directed
Supply only chlorination chemical highly efficient (high strength) calcium based granular disinfectant, more stable than chlorine gas, highly stable, in sealed container to check no sodium, iron/mercury/heavy metal contaminations, etc. complete all as specified Note: (i) Paid vouchers of calcium based granular disinfectant shall be submitted (ii) The calcium based granular disinfectant shall be brought at site/store in sealed plastic container of appropriate capacity / size asked (iii) The brand of chemical shall be as approved by the GE
Supply only Orthotolidine (OT) solution in 500 ml bottle all as specified and directed.
Supply and fixing self closing PVC bib taps 15 mm dia screwed with existing GI pipe complete ISI marked all as specified and directed.
Supply and fixing in replacement Gun metal Gate valve, screwed both ends for iron pipe of 20 mm bore ISI marked. all as specified and directed.
Supply and fixing in replacement Gun metal Gate valve, screwed both ends for iron pipe of 25 mm bore ISI marked. all as specified and directed.
Supply and fixing in replacement Gun metal Gate valve, screwed both ends for iron pipe of 40 mm bore ISI marked. all as specified and directed
Supply and fixing in replacement butterfly valve, screwed both ends for iron pipe of 50 mm bore ISI marked. all as specified and directed.
M&L for potability water chemical analysis testing of water to be conducted through laboratories authosied by NABL, PPCB & CPCB for analyis of pH, colour, odour, taste, turbidity, total hardness, total alkalinity, iron, chloride, residual free chlorine, fluroide, total dissolved solids, sulphate, nitrate, total Coliform, e-coli, etc. including collecting of water from the source in a specialised glass bottle designated for this purpose, submitting samples and collecting reports from the laboratory complete all as specified and as directed Notes: (a) Laboratory shall be as approved by the GE. The Contractor has to get the same approved in due course of time (b) All requirements for collection, submission, etc. of samples, cartage, etc. shall be included in the quoted rate (iii) The Contractor has to submit reports to the Engineer-in-charge for his approval and the same shall be submitted and kept on records and produced alongwith claims for such testing works in RARs
M&L for earthing using GI earthing strip with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI strip of size 32x6mm extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (light grade), earth lead protection pipe 32mm light grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC cover 50mm thick and testing on completion including making test points on wall as per SSR specifications complete all as specified and as directed
Supply, fix, installation and testing (replacement) of ultra sonic non contact sensor for level monitoring for overhead tank with following specification:- Principal:- Ultrasonic sound waves water level sensing. O/P Port:- 4-20 ma/0-20 V Data Transmitting out put port SCADA Operation output port Range 8 Meters with anti theft device (micro controller based). make: Unison/Crystal/Banner/As per OEM of automation panel.
Supply, installation, testing & commisioning (replacement) of high torque motorize valve with gears and adopters self lubricating type, weather proof with gears and adopters self lubricating type, weather proof with protection against, over voltage Jamming of valve and over current protection with manual by-pass arrangement to open/Close the valve on power failure having following features:- (a) Valve size:-150 MM (b) Designed line pressure 4 Kg/sq cm (c) Operating angles:-90 degree (d) Disc Material:- CI with nylon coating (e) Valve type:-Butterfly valve PN 1.0 with geared motor on top. (f) SCADA output pot. (g) Anti theft device micro controller based (h) Torque 35 Nm running time 13s (i) Close off pressure 1200 KPA (j) Operating voltage 230 V AC with 2 in built auxiliary switches, IP 67 with control relay 24/12V & 2 Nos change over. Make: Belimo/ Leader/ Kirloskar
Supply & fixing on wall/ laying in ground 4 pair X 1.5 Sqmm PVC insulated & PVC copper armoured cable with heavy duty PVC Saddles 60 cm apart complete all as specied and directed. Make: L&T/ Grandlay/ KEI
Supply & fixing on wall/ laying in ground 6 pair X 1.5 Sqmm PVC insulated & PVC copper armoured cable with heavy duty PVC Saddles 60 cm apart complete all as specied and directed. Make: L&T/ Grandlay/ KEI
M & L for welding the existing leakage GI Pipe line any size by using electric welding machine & welding electrode. Note : Earth work shall be measured and paid separately under respective item of shedule
Supply fix installation and testing of microprocessor based circuit type water level device consists of seven segment 2" LED display fitted in the control panel made of CRCA 16 SWG sheet with chemical grade power coating to display water level in tank, SS304 grade level sensor pipe fitted in the tank by clamping at the bottom and the tod of the tank consists of magnetic float and electronic switch for long life, the pump automatically switchh of when the water level in OHT reaches the maximum level. Visual display with audio alarm on low water level in tank, Audio alarm on full tank with ON-OFF control, toggle switch for manual run of pump when tank is full, heavy duty rubber coated wire (Appx 100 mtrs) for connecting the censor all as specifed and directed.
Supply and fix in replacement Air termination, single pointed rod 12 mm dia and 300 mm long in existing GI pipe of 20-25 mm dia on existing over head water tank all as specified and directed.
Supply and fix in replacement test point terminal block made of gun metal or phasphorus bronze size 75 X 75 X 25 mm drilled and screwed including 3 Nos. 8 mm dia 25mm long hex. head screw all as specified and directed.
Supply and fix in replacement GI strip 25 X 3.15 mm with saddles and fixing screws etc for roof conductors above ground on over head water tank all as specified and directed.
M&L for PCC block of size 30 x 30 x 30 cm type B-1, 1:2:4 (20 mm graded aggregate) with and including embedded 25 mm dia GI pipe medium grade 1.00 mtr long for fixing air termination including all necessary fixing arrangement on over head water tank all as directed.
S&F integral solar aviation LED light comprising of aluminium housing with polycarbonate enclosure, lighting colour: Red, Input Voltage: 180 - 280V AC 0r 40 - 58V DC, IP66 rating including taking down old one from OHT reservior of 30 Mtr Height. Make:- Geltronix, Bajaj, Crompton
S&F integral LED aviation lighht comprising of aluminium housing with polycarbonate enclosure, lighting colour: Red, Input Voltage: 180 - 280V AC, IP66 rating including taking down old one from High mast lamp. Make:- Bajaj, Geltronix, , Crompton
S&F 1100 volt grade heavy duty cable PVC insulated multistranded aluminum conductor served with PVC tape and over all PVC sheathed in service connections suspended through PVC pipe 20 mm dia medium grade with staging of over head tank one twin core cable flat or circular of size 6 Sqmm incl taking down old service connection and removing from the side complete all as specified and as directed. Make:- Havell's/CCI/Poly Cab/Finolex
S&F distribution board single door two way without bus bar complete with MCB SPN 6 Amp 'C' series all as specified and directed. Make: IndoAsian/Havells/C&S
Material and labour for plain cement concrete 1:3:6 (40mm graded aggregate ) type C-2 with necessary form work all as specified and directed.
M&L for Pressure gauge-03 Nos, Pressure switch-03 Nos of existing capacity including repairing, welding, checking leakage of exiting fire pump room complete all as specified and size directed by Engr-in-Charge.
Supply & fix energy meter AC 3 phase thread through 40-200Amp DLMS type integrated with inbuilt CT including its necessary connection with existing XLPE cable all as specified and directed. Make: HPL/ Secure/ L&T
M&L for Writing letters or figures (Block. Roman, Italic or Indian) n exc. 30 cm high all as specifed.
M&L for writing stops, commas, short lines, dashes, hyphens, brackets etc all as specifed.
M&L of preparation of old steel surfaces (with rubbing sand paper) of any description, over 10cm in width or girth, applying one coat of synthetic enamel paint all as specified.
Material and labour for display board of size 5 feet x 4 feet of thickness 8 inch duly made on white polyvinyl sheet exactly showing the line diagram of 33/11 KV MRS of 166 MH sub-station duly marked properly with computer generated letter the with the details of machinary installed with Nos, capacity/ rating and make etc of approved size on poly vinyl sheet, both duly illuminated with 18 watt LED tube light 04 nos, with holder and necessary connection wire and accessories, at the back side of chart for prominent appearance duly encased in a Galavanied steel sheet frame enclosure and alongwith MES monogram and supported with 40 mm steel pipes duly polished 8 feet long grouted in PCC 1:4:8 of size 20 cm X 20 cm x 45 cm in ground including all civil works complete all as specified and approved by the Engr-in-Charge.
Material and labour for display board of size 5 feet x 4 feet of thickness 8 inch duly made on white polyvinyl sheet exactly showing the line diagram of 11 KV MRS of raipur Satwari sub-station duly marked properly with computer generated letter the with the details of machinary installed with Nos, capacity/ rating and make etc of approved size on poly vinyl sheet, both duly illuminated with 18 watt LED tube light 04 nos, with holder and necessary connection wire and accessories, at the back side of chart for prominent appearance duly encased in a Galavanied steel sheet frame enclosure and alongwith MES monogram and supported with 40 mm steel pipes duly polished 8 feet long grouted in PCC 1:4:8 of size 20 cm X 20 cm x 45 cm in ground including all civil works complete all as specified and approved by the Engr-in-Charge.
Dismantling posts or struts (wood, steel, RCC) any section including taking our embedded portion and making good disturbed ground etc all as directed
Dismantling fencing wire mesh any type all as directed
Excavating in any type of soil for post holes (or similar holes) each n exc. 0.5 cum. Getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm.watering and removing surplus soil to a distance n. exc. 50 metre and making good surface.
M&L for Cement concreteType D2 1:4:8 (40 mm graded ) in foundations, filling and mass concrete complete all as specified.
M&L for Cement concreteType B2 1:2:4 (40 mm graded ) in foundations, filling and mass concrete complete all as specified.
M & L Mild steel posts and struts in n fencing including cutting tops to shape as directed drilling holes, notching for wires etc flat iron fillets ( for screwing wire mesh etc ) including all necessary dirilling , bolting or riveting etc and similar work conforming to Fe-290 Gde E-165,all as specified and directed by Engr-in-charge.
Mild steel screw bolts(machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, 11 to 15 mm dia, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long.
S&F galvanized, 2 strand, steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanized mild steel wire, staples or steel pins, etc as directed.
Fixing only Chain link fencing including line wires, any mesh, size & type to any type of standards, rails,fixed with RCC Columns,RCC Posts and struts in fencing including drilling holes bolting, straining blots, etc. including provision of binding wire.
Supply only MS galvanished chain link fencing.
Supply and fixing MS Round bars fix in chain link fencing using 0.90 mm dia GI wire as strengthing bar.
Preparation of new steel surface of any description, over 10cm in width or girth ,not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Preparation of new steel surfaces of any description, n.exc 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer.complete all as specified and directed.
Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S & F for Roof trusses (framed),trussed, purlines, crane gantries,rails and fastenings and heavy bracket framing (Beam,tee, angle,channel or flat sections) including distance pieces, cleats etc of Fe 410 W (Gde-E-250).
Material and labour for PCC (1:2:4) Type B-I, using 20mm graded aggregate as in floor 40mm thick finished even & fair as sub base.
M&L Cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate), 100 mm thick as in sub base.
M&L Spike rolling to surface or making impression of expanded metal,whilst the concrete is green.
Machine pressed precast concrete interlocking paver block coloured with glazed finish (Laqquere finished) any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade (with grey cement and no pigment) laid dry over sand cushion of average thicknedss 25 mm duly consolidated, set and levelled complete all as specified and size directed by Engr-in-Charge.
S&F 225-250 LPH industrial RO plant with UV works bu using pressure pump to increase the pressure on the salt side of the RO and force the water across the membranes, Max water recovery rate not less than 60% fully automatic with fine powder coating fully automatic operating system with online TDS meter, flow meter etc. PLC based panel board with necessary connection on existing water supply system all as specified. Make : Osmosis /OM ION Exchange / ZeroB
S&F centrifugal pump set 0.5 HP with totally inclosed air cooled fan single phase, full load current 3 Amp, 240 Volts, 50Hz speed 2800 rev/sec, class 'B' insulation including necessary plumbing work connection on existing water supply system with GI sheet 3.15 mm thick removable cover with 25x25x5 mm angle iron frame to protect the motor from rain all as specified. Make : Crompton / Kirloskar / CRI
M/S AMBASSADOR ELECTRIC WORKS
M/S S K Electricals Regd
M/S SHREE KRISHANA ENERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .