Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAdmitted-Finance | ₹1.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.5 Cr+₹35.5 L (30.1%)Admitted-Finance | ₹1.5 Cr+₹35.5 L (30.1%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Agency has not fulfilled eligibility criteria as per NIT |
| Sl No | Description | Qty | Unit | Relyaxis Enterprises L2 | SUMIT SWITCHGEARS & ELECTRICALS L1 |
|---|---|---|---|---|---|
| 1.00Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. | |||||
| 1.10 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire | 150 | METER | 1,125.34 ₹1,68,801 | 1,000 ₹1,50,000 Lowest |
| 1.20 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire | 3,000 | METER | 1,589 ₹47,67,000 | 1,200 ₹36,00,000 Lowest |
| 2.00Supply and Laying of one XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 3½ core ISI marked with alu. stranded /solid conductor following size in the existing RCC/ HUME/ METAL pipe as required. | |||||
| 2.10 | 3½ x 400 sq mm armoured | 2,010 | MTR | 3,057 ₹61,44,570 | 2,700 ₹54,27,000 Lowest |
| 3.00 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. | 18 | Nos. | 1,489 ₹26,802 | 1,200 ₹21,600 Lowest |
| 4.00 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. | 20 | Nos. | 492 ₹9,840 | 250 ₹5,000 Lowest |
| 5.00 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. | 2,000 | MTR | 234 ₹4,68,000 | 110 ₹2,20,000 Lowest |
| 6.00 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. | 100 | MTR | 69 ₹6,900 Lowest | 75 ₹7,500 |
| 7.00 | SITC of maintenance free chemical earthing with copper Earthing Electrode of size 50mmX 3000mm with 20 kg chemical bag | 10 | Nos. | 18,349 ₹1,83,490 | 17,500 ₹1,75,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹3.3 L
Closing Date
17 Feb 2025, 3:00 pmClosed
Superintending Engineer, AIIMS Bhopal
Office of the Superintending Engineer, Project Cell, MoHFW, Block No. 10, Hospital Building, AIIMS, Saket Nagar, Bhopal, 462020.
Electrical Infrastructure work for MOT in Hospital Building at AIIMS Campus Bhopal.
2025_IMSBP_845998_1
17/NIT/ SE/Project Cell/ABEU/AIIMS/BPL/2024-25
Open Tender
Electrical Works
Item Rate
AIIMS Bhopal
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹3.3 L
Office of the Superintending Engineer,AIIMS Bhopal
24 Mar 2025
24 Jan 2025
18 Feb 2025
24 Jan 2025
17 Feb 2025
7 Feb 2025
31 Jan 2025
Amount
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supply and Laying of one XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 3½ core ISI marked with alu. stranded /solid conductor following size in the existing RCC/ HUME/ METAL pipe as required.
3½ x 400 sq mm armoured
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
SITC of maintenance free chemical earthing with copper Earthing Electrode of size 50mmX 3000mm with 20 kg chemical bag
Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
300 mm dia
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade
Two or more coats on new work
Supply & Installation Testing and Commission of Indoor type Main LT Panel incommer-2000Amp , and Outgoing Feeder -1000A,800A. For all items Described in SoQ as per NIT. (Item No.12).
SITC of HVAC Panel Incomer 800 amp.& Outgoing feeder along with the accessories complete as required. For all items Described in SoQ as per NIT. (Item No.13).
Relyaxis Enterprises (BID ID -3172434)
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .