Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 LAccepted-AOC | L1 | Accepted-AOC work allotted | |
| 2 | L2₹2.9 L+₹3,701 (1.28%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical 498 JARNALLY KOTHI OPP PARVEEN HOSPITAL KARNAL | KARNAL | KARNAL | HARYANA | - | Rejected-Technical Enlistment exp. 31.3.21 |
Tender Value
₹2.5 L
EMD Value
₹5,080
Closing Date
5 Apr 2021, 2:00 pmClosed
Executive Engineer
Executive Engineer, Elect. Division PWD BandR Br., Karnal (0184-2265696)
Up-gradation of PHC into AB-HWC at village Ujha, Sewah, Atta, Patti Kalyana Distt. Panipat (Providing Special repair to EI) Recall
2021_HRY_157614_2
PHC Ujha,Sewah, Atta, Patti Kalyana
Open Tender
Electrical Works
Works
60 days
Panipat
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
₹5,080
Yes
28 Jun 2021
26 Mar 2021
5 Apr 2021
26 Mar 2021
5 Apr 2021
26 Mar 2021
Amount
31.9 Supply and erection of PVC copper insulated and sheathed 2-core circular flexible wire. Size 1.50 sqmm ( 48 / 0.20mm).
31.12 (a) Supply and erection of metal clad switches / B.D.Bs with rag bolts on wall or on existing angle iron board / pedestal including bonding to earth and necessary connections . Triple pole switch with neutral link 32 amp. 415 Volts.
31.12 (a) (xv) Cat-B Triple pole switch with neutral link 63 amp. 415 Volts.
31.12 (a)(xvi) Cat-B Triple pole switch with neutral link 100 amp. 415 Volts.
31.17 (a) (ii) Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections. SPN MCB of 9 KA breaking capacity 6 amp. To 32 amp.
SP MCB of 9 KA breaking capacity 6 amp. to 32 amp.
31.18 (xxiv) Erection only of 1x40 watts or 2x40 watts 1220 mm long / 1x20 watts or 2x20 watts ,610 mm long fluorescent tube fitting directly on wall including necessary connections with 0.75 sqmm ( 24 / 0.20 mm ) PVC copper flexible cable for connecting the tube with the adjecent point.
31.18 (xii) Switch 5 amp. On existing sheet.
31.18 (xiii) Wall socket 5 amp. On existing sheet.
31.18 (xiv) 15 amp. Switch on existing sheet .
31.18 (xv) 3 pin 15 amp. Multi socket on existing sheet.
31.20 (i) Erection of ceiling fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to the site of work.
31.20 (iii) Erection of exhaust fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to he site of work.
31.20 (v) Making suitable hole in the wall upto 450 mm sweep exhaust fan including finishing the same and fixing of wire mesh duly fixed with Deodar wood frame of section 40 mm x 25 mm thick.
31.20 (vi) Pdg. and fixing of required size of deodar wood frame of section 50 mm x 32 mm for fixing exhaust fan upto 450 mm sweep.
31.22(i) Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as required .
31.22(ii) Extra for using salt and charcoal / coke for pipe earth electrode as required.
31.26 Supply and erection of under ground cable, loose in existing pipe or trenches complete with necessary connections . 31.26 (iv)Ard. 10 Sq. mm 2 Core Cable .
31.26 (v)Ard. 16 Sq. mm 2 Core Cable .
31.26 (xIi) Ard. 25 Sq. mm 4 Core Cable .
31.30 (III( xv ) Supply and erection of 32 mm dia meter 1.5 metre long bracket ( B-Class ) making an angle of 10 to 15 degree with horizontal plane for mounting street light fitting fixing of GI bracket on wall with 2 Nos. , 32 mm x 3 mm thick MS clamps including the cost of cutting , welding of GI pipe complete with cement sand mixture , bolts and nuts etc. including necessary connections .
31.38 Wiring only in 1.5 Sqmm PVC insulated copper conductor cable in existing conduit pipe and MS boxes covered with 5mm thick bakelite sheet including cost of switch, wall socket, ceiling rose etc. Fan Point Medium Point
Long point.
Light Point Short point
Medium Point
Long point.
Call bell point Long point.
3 pin 5 amp. plug point including earthing the 3rd. pin etc. Short point
Medium Point
Long point.
3 pin15 amp. plug point with 4 sq mm PVC insulated Copper conductor cable- including earthing the 3rd. pin etc. Long point.
31.40 Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe . Size 1.5 sqmm ( 3/0.81 )
Size 2.5 sqmm ( 3/1.05 )
Size 4 sqmm ( 7/0.85 )
31.41 Supply and erection of Double door sheet steel enclosure distribution boards suitable for MCB's & ELCB's recessed in wall including bonding to earth complete with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4-way , TP&N ( Horizontal) (8+12)
8-way , TP&N ( Horizontal) (8+24)
31.55 Supply & erection of Socket size rotary step type Electronic regulator for A.C. ceiling fan Anchor make Delux model No. 50440 ISI / SSK make PC 561 operated on 120/280 V A.C. Supply complete including cutting of existing Bakelite sheet and making necessary connection etc. up to the entire satisfaction of the Engineer-in-Charge of the Work.
NS item Supply and erection of 72W LED Streetlight Luminaires of Makes: Bajaj / Crompton / GE / Philips / Wipro with Pressure die cast aluminium housing with lens and accessories required to complete the job in all respect including erection on existing pole for fixing including connection of the same upto the entire satisfaction of Engineer in Charge of the work.
BHARAT RADIO & ELECTRONICS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .