Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-AOC | L1 | Accepted-AOC Awarded Being Lowest Bidder | |
| 2 | L2₹21.2 L+₹14,359 (0.68%)Rejected-AOC PLOT NO 4 SUDARSHAN ROW RESIDENCY GAWADE MALA PIPELINE ROAD SAVEDI AHMEDNAGAR 414003 | AHMEDNAGAR | AHMEDNAGAR | MAHARASHTRA | 414003 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹22.2 L+₹1.2 L (5.60%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹23.7 L+₹2.6 L (12.6%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹24.0 L+₹2.9 L (14.0%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
22 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (N) Ahmednagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahmednagar 414 002
Repair Maint Security light Street lights light at MH EME workshop AC Record GE(N) Md Accn FAFA Md Accn BTR Vijay line under GE(N) Ahmednagar
2021_MES_436199_1
8520/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (N) Ahmednagar
Class D Cat b(I)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer North Ahmednagar
₹60,000
Yes
1 Jun 2021
13 Apr 2021
24 May 2021
13 Apr 2021
22 May 2021
8 May 2021
60 days
Amount
Excavating in trenches n exc 1.5 mtr wide and n exc 1.5m in depth , for foundation ,etc or for shafts, wells , cesspits, main holes etc.n exc 10 sqm on plan and n exc 1.5 mtr depth and getting out on soft/ lose soil etc complete all as specified and directed by Engineer-in-Charge
All as per ser item no 1 (here-in-before) but hard/ dense soil etc complete all as specified and directed by Engineer-in-Charge
Returning, filling in, including spreading , levelling , watering and well ramming in layers not exc 25cm of any soil etc complete all as specified and directed by Engineer-in-Charge.
Supply and Lay HDPE pipe 50 mm dia for laying of LT cables etc complete with all accessores all as specified and directed etc by Engineer-in-Charge
Removing excavated materials(soils) n exc 50m and depositing where directed at a level n exc 1.5m above the starting point etc complete all as specified and directed by Engineer-in-Charge
Material and labour in replacement of 25 mm dia GI Pipe light grade ISI Marked with all fittings laid in trenches , fixed to walls / poles with FI Clamps of size 40x5 mm etc complete all as specified and directed by Engineer-in-Charge.
Dismantling carefully the existing unserviceable LT overhead line ACSR conductor any size from its position by necessary disconnecting of conductor and removing complete etc complete all as specified and directed by Engineer-in-Charge. Note: Assumed one Span is taken on 12 Kg approx
Dismantling of unserviceable insulator of any type complete from its position and removing etc complete all as specified and directed by Engineer-in-Charge.
Dismantling of unserviceable existing cross arms made from channels, angles and unserviceable FI clamps, nuts, bolts etc from OH line and removing etc complete all as specified and directed by Engineer-in-Charge.
Taking out existing unserviceable UG Cable by disconnecting of connections and laying only LT UG Cable of following size . Note :-(a) UG Cables , Excavation, RFR, & Removing are paid separately.
(a) 10 Sqmm, 2 Core
(b) 10 Sqmm, 4 Core
(c ) 16 sqmm, 4 Core
Supply, Laying & testing XLPE, insulated armoured heavy duty electric LT UG Cable with aluminium conductor, 1100 volt of following Sizes etc complete all as specified and directed by Engineer-in-Charge.
(a) 10 Sqmm, 2 Core
(b) 10 Sqmm, 4 Core
(c ) 16 sqmm, 4 Core
Supply and replacement of 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension GI wire, one twin core cable flat or circular with size 4sqmm etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 18 (here-in-before) but 6 Sqmm, two Core
All as per Item No 18 (here-in-before) but 10 sqmm, 2 Core
Material and labour in replacement of 40mm dia GI Pipe light grade ISI Marked with all fittings laid in trenches , fixed to walls / poles with FI Clamps of size 40x5 mm etc complete all as specified and directed by Engineer-in-Charge.
Taking out Old existing security leight (HPSV/Tube light fitting) and Supply , installation, Testing & commissioning of LED based street light, housing made up of pressure die cast housing LM6/ADC 12 Alloy with toughened glass. The fixture should have a minimum system efficancy of greater than > 110 lumen/Watt and a minimum system output with high power LED between 3 to 5 W with proper secondary optics lens nominal system wattage of 45 Watts. The fixture shall have a CRI if minimum 45. The fixture shall be designed for a system life of 5 year maintenance ingress protection of IP-66 (lampand gear compartment ) and Mechanical impact resistance rating of IK>=07. The fixture driver should have an operating voltage range of 140-270V surge protection of >=4KV with driver &10 KV SPD, Pf-0.9, THD ,10% and SDCM,5. The fixture should have top openable driver compartment for easy of mantenance, the driver should be BIS approved fully potted. Enclosed type/encapsulated drivers won't be accepted. driver should have 440 V stress voltage also have low voltage protection at 100 V AC fro 48 hours, High cut off: 320 V(+/-15V) and Auto Restart function should also be availabel within the fixture. Driver should be of the same brand as Luminaire brand embossing on the fixture housing for traceability till life. The fixture shouls comply with the parameter as per IS10322/60598. The LED driver should comply to IEC61000-3-2 ed 3.2,2009 for HarmonicsIEC61347-1ed.2.0, 2007 for electrical safety IEC62384ed1.1, 2011 for performance and IEC61547 ed2.0, 2009 , manfacturer shall have inhouse lab approved by NABL. LM 79 and LM80 reports need to be submitted form a NABL/UL accredited lab to verify above parameter. fixed with suitable size of GI Bracket,Clamp,Nut, Bolt and washer , connection with 1.5 sqmm 3 run copper wire from junction box etc complete all as specified and directed by Engineer-in-Charge.
Dismentalling and taking down carefully the defective street light /security light fitting of any description / type (HPSV/HPMV/MH/LED/FTL/T5 fitting etc) and servicing/cleaning checking connections including M & L for PVC insulated copper conductor multistranded twin core 1 sqmm cable from connector block to choke and choke to lamp holder , approximately 0.30m length ,and reassembling ,and 2.5 sqmm twin core service wire from connector to junction box or OH conductor and refixing at its original location , including reconnections and testing / commissioning etc complete all as specified and directed by Engineer-in-Charge. Note :- Choke, lamp and ignitor shall be measured and paid separately.
Supply only in replacement of VPIT ballast , heavy duty copper wound , suitable for HPSV/MH lamp 70 watt ,Make :- PHILIPS cat part No:- BSN070M261 or equivalent in makes mentioned in list of makes in Appendix `C'
Supply only replacement of VPIT ballast , heavy duty copper wound , suitable for HPSV/MH lamp 150 watt ,Make :- PHILIPS cat part No:- BSN150M362 or equivalent in makes mentioned in list of makes in Appendix `C'
Supply only in replacement of VPIT ballast , heavy duty copper wound , suitable for HPSV/MH lamp 250 watt ,Make :- PHILIPS cat part No:- BHL250X261 or equivalent in makes mentioned in list of makes in Appendix `C'
Supply and Fixing sodium vapour lamp 70 watt suitable for HPSV 70 watt ballast. Make :- Philips cat part No SON Lamps 70W Tubular or equivalent in makes mentioned in list of makes in Appendix `C'
Dismantling and taking down carefully the defective Highmast light fittings by mechanically/ manually and removing the unseviceable chowk , MH Lamp tubular type any wattage and ignitor and repair/ replace it by new items and servicing/cleaning checking connections including M & L for PVC insulated copper conductor multistranded twin core 2.5 sqmm cable from connector block to choke and choke to lamp holder , approximately 0.30m length ,and reassembling , and refixing at its original location , including reconnections and testing / commissioning etc complete all as specified and directed by Engineer-in-Charge. Note :- Choke, lamp and ignitor shall be measured and paid separately.
Lifting the Highmast pole 16 mtr height by crane from its own location with opening the nut boltt and washers , greasing the steel wire rope and fixing with pulley and reassembling and refixing at its orginal location, including reconnections and testing commissioning complete for smooth operations etc complete all as specified and directed by Engineer-in-Charge. Note: (i) Rate for Crane and labours is being to be includes in Quoted rates. (ii) Rate of sundry items like grease, cotton waste, nut , bolt and washers are deemed to be quoted rates.
Supply only in replacement of MH Lamp For 400 watt fittings(Single ended) MHL 400 Watt SE Tubular. . Make :- CG cat part No MHL400W SE TUBULAR E-40 or equivalent in makes mentioned in list of makes in Appendix `C'
Supply only in replacement of VPIT ballast , heavy duty copper wound , suitable for HPSV/MH lamp 400 watt ,Make :- PHILIPS cat part No:- BSN400M 363 or equivalent in makes mentioned in list of makes in Appendix `C'
Supply only in replacement of MH Lamp SE tubular Single ended of capacity 70 watt. Make :- CG cat part No MHL70W SE TUBULAR E-27 or equivalent in makes mentioned in list of makes in Appendix `C'
Supply only in replacement of MH Lamp SE tubular Single ended of capacity 150 watt . Make :- CG cat part No MHL 150W SE TUBULAR E-27 or equivalent in makes mentioned in list of makes in Appendix `C'
Supply only in replacement of MH Lamp tubular Single ended of capacity 250 watt . Make :- CG cat part No MHL250W SE TUBULAR E-40 or equivalent in makes mentioned in list of makes in Appendix `C'
Supply only three pole contactor coil suitable for L&T contactor cat part No CS94980 or equivalent in makes mentioned in list of makes in Appendix `C'
Supply only in replacement of Tube Lights (Tube Rod) T5 24 watt 6500K ( Lux) +B60
Supply only in replacement of electronic ballasts for fluorescent tubes of capacity 2x24 watt . Make :- HPL cat part No:-HPLEB224WO or equivalent in makes mentioned in list of makes in Appendix `C'
Supply only in replacement of electronic ballasts for fluorescent tubes of capacity 2x14 watt . Make :- HPL cat part No:-HPL EB214WO or equivalent in makes mentioned in list of makes in Appendix `C'
Supply only in replacement ignitor SP 230 V , 50 HZ suitable for 70 watt to 400 watt HPSV fitting make: HPL cat part No HIIGN70400LD or equivalent in makes mentioned in list of makes in Appendix `C'
Supply only in replacement of electronic ballasts for fluorescent tube of capacity 1x36/40 watt Make :- Philips cat part No EB-FS136TLD240 or equivalent in makes mentioned in list of makes in Appendix `C'
Supply only in replacement of MH Lamp Double ended Rx7S of capacity 70 watt . Make :- CG cat part No MHL70W DE RX7S or equivalent in makes mentioned in list of makes in Appendix `C'
Supply only in replacement of MH Lamp Double ended of capacity 150 watt . Make :- CG cat part No MHL 150W DE RX7S or equivalent in makes mentioned in list of makes in Appendix `C'
M & L for painting of Street light poles (SWAN NECK) in two coats of aluminium paint and one coat of red oxide as primer including writing of pole nos all as directed in Engr-in- Charge.
M & L for painting of Street light poles tubular type 9 mtr long in two coats of aluminium paint over one coat of red oxide as primer after preparing the surface including writing of pole nos all as directed in Engr-in-Charge.
M & L for painting of Street light poles tubular Swan neck double side type 11 mtr long in two coats of aluminium paint and one coat of red oxide as primer including writing of pole nos all as directed in Engr-in-Charge. (including four pole structure)
Supply and fix in replacement of MCB TPN, 63 Amps 10 KA breaking / rupturing capacity capacity 415 volt , 50 HZ conforming to IS 60898-1 including necessary connection with suitable size of copper cable complete all as directed. MAKE: CAT No DSMSCTNFO63 OF Standard or equivalent in makes mentioned in list of makes in Appendix `C'
Taking out Old existing security leight (HPSV/Tube light fitting) and Supply , installation, Testing & commissioning of LED based street light, housing made up of pressure die cast housing LM6/ADC 12 Alloy with toughened glass. The fixture should have a minimum system efficancy of greater than > 110 lumen/Watt and a minimum system output with high power LED between 3 to 5 W with proper secondary optics lens nominal system wattage of 65 Watts. The fixture shall have a CRI if minimum 65. The fixture shall be designed for a system life of 5 year maintenance ingress protection of IP-66 (lampand gear compartment ) and Mechanical impact resistance rating of IK>=07. The fixture driver should have an operating voltage range of 140-270V surge protection of >=4KV with driver &10 KV SPD, Pf-0.9, THD ,10% and SDCM,5. The fixture should have top openable driver compartment for easy of mantenance, the driver should be BIS approved fully potted. Enclosed type/encapsulated drivers won't be accepted. driver should have 440 V stress voltage also have low voltage protection at 100 V AC fro 48 hours, High cut off: 320 V(+/-15V) and Auto Restart function should also be availabel within the fixture. Driver should be of the same brand as Luminaire brand embossing on the fixture housing for traceability till life. The fixture shouls comply with the parameter as per IS10322/60598. The LED driver should comply to IEC61000-3-2 ed 3.2,2009 for HarmonicsIEC61347-1ed.2.0, 2007 for electrical safety IEC62384ed1.1, 2011 for performance and IEC61547 ed2.0, 2009 , manfacturer shall have inhouse lab approved by NABL. LM 79 and LM80 reports need to be submitted form a NABL/UL accredited lab to verify above parameter. fixed with suitable size of GI Bracket,Clamp,Nut, Bolt and washer , connection with 1.5 sqmm 3 run copper wire from junction box all as specified and directed. Make : Crompton or equivalent in Appx C
Taking out Old existing security leight (HPSV/Tube light fitting) and Supply , installation, Testing & commissioning of LED based street light, housing made up of pressure die cast housing LM6/ADC 12 Alloy with toughened glass. The fixture should have a minimum system efficancy of greater than > 110 lumen/Watt and a minimum system output with high power LED between 3 to 5 W with proper secondary optics lens nominal system wattage of 20 Watts. The fixture shall have a CRI if minimum 20. The fixture shall be designed for a system life of 5 year maintenance ingress protection of IP-66 (lampand gear compartment ) and Mechanical impact resistance rating of IK>=07. The fixture driver should have an operating voltage range of 140-270V surge protection of >=4KV with driver &10 KV SPD, Pf-0.9, THD ,10% and SDCM,5. The fixture should have top openable driver compartment for easy of mantenance, the driver should be BIS approved fully potted. Enclosed type/encapsulated drivers won't be accepted. driver should have 440 V stress voltage also have low voltage protection at 100 V AC fro 48 hours, High cut off: 320 V(+/-15V) and Auto Restart function should also be availabel within the fixture. Driver should be of the same brand as Luminaire brand embossing on the fixture housing for traceability till life. The fixture shouls comply with the parameter as per IS10322/60598. The LED driver should comply to IEC61000-3-2 ed 3.2,2009 for HarmonicsIEC61347-1ed.2.0, 2007 for electrical safety IEC62384ed1.1, 2011 for performance and IEC61547 ed2.0, 2009 , manfacturer shall have inhouse lab approved by NABL. LM 79 and LM80 reports need to be submitted form a NABL/UL accredited lab to verify above parameter. fixed with suitable size of GI Bracket,Clamp,Nut, Bolt and washer , connection with 1.5 sqmm 3 run copper wire from junction box all as specified and directed. Make : Crompton or equivalent in Appx C
Supply and fix in replacement of LED post top lantern 40 Watt, with spun aluminium canopy & die cast aluminium spigot with opal PMMA acrylic diffuser pre wired with all accessories including making necessary connections and make it functional complete all as specified and as directed. . Make : Crompton cat Part No- LPTO-40-CDL or equivalent in makes mentioned in list of makes in Appendix `C'
Taking out Old existing security leight (HPSV/Tube light fitting) and Supply , installation, Testing & commissioning of LED based street light, housing made up of pressure die cast housing LM6/ADC 12 Alloy with toughened glass. The fixture should have a minimum system efficancy of greater than > 110 lumen/Watt and a minimum system output with high power LED between 3 to 5 W with proper secondary optics lens nominal system wattage of 30 Watts. The fixture shall have a CRI if minimum 30. The fixture shall be designed for a system life of 5 year maintenance ingress protection of IP-66 (lampand gear compartment ) and Mechanical impact resistance rating of IK>=07. The fixture driver should have an operating voltage range of 140-270V surge protection of >=4KV with driver &10 KV SPD, Pf-0.9, THD ,10% and SDCM,5. The fixture should have top openable driver compartment for easy of mantenance, the driver should be BIS approved fully potted. Enclosed type/encapsulated drivers won't be accepted. driver should have 440 V stress voltage also have low voltage protection at 100 V AC fro 48 hours, High cut off: 320 V(+/-15V) and Auto Restart function should also be availabel within the fixture. Driver should be of the same brand as Luminaire brand embossing on the fixture housing for traceability till life. The fixture shouls comply with the parameter as per IS10322/60598. The LED driver should comply to IEC61000-3-2 ed 3.2,2009 for HarmonicsIEC61347-1ed.2.0, 2007 for electrical safety IEC62384ed1.1, 2011 for performance and IEC61547 ed2.0, 2009 , manfacturer shall have inhouse lab approved by NABL. LM 79 and LM80 reports need to be submitted form a NABL/UL accredited lab to verify above parameter. fixed with suitable size of GI Bracket,Clamp,Nut, Bolt and washer , connection with 1.5 sqmm 3 run copper wire from junction box all as specified and directed. Make : Crompton or equivalent in Appx C
Supply and Fixing sodium vapour lamp 150 watt suitable for HPSV 150 watt ballast. Make :- Philips cart part No SON Lamps 150W Tubular or equivalent in makes mentioned in list of makes in Appendix `C'
Taking out Old existing security leight (HPSV/Tube light fitting) and Supply , installation, Testing & commissioning of LED based street light, housing made up of pressure die cast housing LM6/ADC 12 Alloy with toughened glass. The fixture should have a minimum system efficancy of greater than > 110 lumen/Watt and a minimum system output with high power LED between 3 to 5 W with proper secondary optics lens nominal system wattage of 60 Watts. The fixture shall have a CRI if minimum 60. The fixture shall be designed for a system life of 5 year maintenance ingress protection of IP-66 (lampand gear compartment ) and Mechanical impact resistance rating of IK>=07. The fixture driver should have an operating voltage range of 140-270V surge protection of >=4KV with driver &10 KV SPD, Pf-0.9, THD ,10% and SDCM,5. The fixture should have top openable driver compartment for easy of mantenance, the driver should be BIS approved fully potted. Enclosed type/encapsulated drivers won't be accepted. driver should have 440 V stress voltage also have low voltage protection at 100 V AC fro 48 hours, High cut off: 320 V(+/-15V) and Auto Restart function should also be availabel within the fixture. Driver should be of the same brand as Luminaire brand embossing on the fixture housing for traceability till life. The fixture shouls comply with the parameter as per IS10322/60598. The LED driver should comply to IEC61000-3-2 ed 3.2,2009 for HarmonicsIEC61347-1ed.2.0, 2007 for electrical safety IEC62384ed1.1, 2011 for performance and IEC61547 ed2.0, 2009 , manfacturer shall have inhouse lab approved by NABL. LM 79 and LM80 reports need to be submitted form a NABL/UL accredited lab to verify above parameter. fixed with suitable size of GI Bracket,Clamp,Nut, Bolt and washer , connection with 1.5 sqmm 3 run copper wire from junction box all as specified and directed. Make : Crompton or equivalent in Appx C
Taking out Old existing security leight (HPSV/Tube light fitting) and Supply , installation, Testing & commissioning of LED based street light, housing made up of pressure die cast housing LM6/ADC 12 Alloy with toughened glass. The fixture should have a minimum system efficancy of greater than > 110 lumen/Watt and a minimum system output with high power LED between 3 to 5 W with proper secondary optics lens nominal system wattage of 40 Watts. The fixture shall have a CRI if minimum 40. The fixture shall be designed for a system life of 5 year maintenance ingress protection of IP-66 (lampand gear compartment ) and Mechanical impact resistance rating of IK>=07. The fixture driver should have an operating voltage range of 140-270V surge protection of >=4KV with driver &10 KV SPD, Pf-0.9, THD ,10% and SDCM,5. The fixture should have top openable driver compartment for easy of mantenance, the driver should be BIS approved fully potted. Enclosed type/encapsulated drivers won't be accepted. driver should have 440 V stress voltage also have low voltage protection at 100 V AC fro 48 hours, High cut off: 320 V(+/-15V) and Auto Restart function should also be availabel within the fixture. Driver should be of the same brand as Luminaire brand embossing on the fixture housing for traceability till life. The fixture shouls comply with the parameter as per IS10322/60598. The LED driver should comply to IEC61000-3-2 ed 3.2,2009 for HarmonicsIEC61347-1ed.2.0, 2007 for electrical safety IEC62384ed1.1, 2011 for performance and IEC61547 ed2.0, 2009 , manfacturer shall have inhouse lab approved by NABL. LM 79 and LM80 reports need to be submitted form a NABL/UL accredited lab to verify above parameter. fixed with suitable size of GI Bracket,Clamp,Nut, Bolt and washer , connection with 1.5 sqmm 3 run copper wire from junction box all as specified and directed. Make : Crompton or equivalent in Appx C
Supply and fix in replacement of timer switch analog FM/1 quartz, 240volt, 50/60 Hz 16 amp/250VAC resistive of Make L&T of cat part No-J648B or equivalent in makes mentioned in list of makes in Appendix `C'
Supply, fix in replacement of Contactor 3 pole AC -1 40 Amps Main Pole Confugration 2 No 2 NC 415 volt fixing with Existing Box by suitable size of copper cable with suitable size of lugs. make L&T Cat Part No-SS90701 or equivalent in makes mentioned in list of makes in Appendix `C'
M &L in replacement of sintex box of size outer side 280x170x130mm for street light control box including 4pole PVC contactor and 35x5mm clamp with nut bolt and washers. Make: Sintex/National or equivalent in makes mentioned in list of makes in Appendix `C'
Taking out Old existing security leight (HPSV/Tube light fitting) and Supply , installation, Testing & commissioning of LED based street light, housing made up of pressure die cast housing LM6/ADC 12 Alloy with toughened glass. The fixture should have a minimum system efficancy of greater than > 110 lumen/Watt and a minimum system output with high power LED between 3 to 5 W with proper secondary optics lens nominal system wattage of 70 Watts. The fixture shall have a CRI if minimum 70. The fixture shall be designed for a system life of 5 year maintenance ingress protection of IP-66 (lampand gear compartment ) and Mechanical impact resistance rating of IK>=07. The fixture driver should have an operating voltage range of 140-270V surge protection of >=4KV with driver &10 KV SPD, Pf-0.9, THD ,10% and SDCM,5. The fixture should have top openable driver compartment for easy of mantenance, the driver should be BIS approved fully potted. Enclosed type/encapsulated drivers won't be accepted. driver should have 440 V stress voltage also have low voltage protection at 100 V AC fro 48 hours, High cut off: 320 V(+/-15V) and Auto Restart function should also be availabel within the fixture. Driver should be of the same brand as Luminaire brand embossing on the fixture housing for traceability till life. The fixture shouls comply with the parameter as per IS10322/60598. The LED driver should comply to IEC61000-3-2 ed 3.2,2009 for HarmonicsIEC61347-1ed.2.0, 2007 for electrical safety IEC62384ed1.1, 2011 for performance and IEC61547 ed2.0, 2009 , manfacturer shall have inhouse lab approved by NABL. LM 79 and LM80 reports need to be submitted form a NABL/UL accredited lab to verify above parameter. fixed with suitable size of GI Bracket,Clamp,Nut, Bolt and washer , connection with 1.5 sqmm 3 run copper wire from junction box all as specified and directed. Make : Crompton or equivalent in Appx C
M & L for replcement of Chain sprocket in Highmast Light etc complete all as specified and directed by Engineer-in-Charge
Taking out Old existing security leight (HPSV/Tube light fitting) and Supply , installation, Testing & commissioning of LED based street light, housing made up of pressure die cast housing LM6/ADC 12 Alloy with toughened glass. The fixture should have a minimum system efficancy of greater than > 110 lumen/Watt and a minimum system output with high power LED between 3 to 5 W with proper secondary optics lens nominal system wattage of 36 Watts. The fixture shall have a CRI if minimum 36. The fixture shall be designed for a system life of 5 year maintenance ingress protection of IP-66 (lampand gear compartment ) and Mechanical impact resistance rating of IK>=07. The fixture driver should have an operating voltage range of 140-270V surge protection of >=4KV with driver &10 KV SPD, Pf-0.9, THD ,10% and SDCM,5. The fixture should have top openable driver compartment for easy of mantenance, the driver should be BIS approved fully potted. Enclosed type/encapsulated drivers won't be accepted. driver should have 440 V stress voltage also have low voltage protection at 100 V AC fro 48 hours, High cut off: 320 V(+/-15V) and Auto Restart function should also be availabel within the fixture. Driver should be of the same brand as Luminaire brand embossing on the fixture housing for traceability till life. The fixture shouls comply with the parameter as per IS10322/60598. The LED driver should comply to IEC61000-3-2 ed 3.2,2009 for HarmonicsIEC61347-1ed.2.0, 2007 for electrical safety IEC62384ed1.1, 2011 for performance and IEC61547 ed2.0, 2009 , manfacturer shall have inhouse lab approved by NABL. LM 79 and LM80 reports need to be submitted form a NABL/UL accredited lab to verify above parameter. fixed with suitable size of GI Bracket,Clamp,Nut, Bolt and washer , connection with 1.5 sqmm 3 run copper wire from junction box all as specified and directed. Make : Crompton or equivalent in Appx C
Supply and fix in replacement of brass batten holder for fixing of gate light etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement FTL fitting Holder 1x36watt / 40watt , disconnecting the old unserviceable holder and fixing the new holder etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Triple pole and Neutral HRC type rewireable Swich fuse unit 63 Amp 415 volt AC 23 A 50 HZ conforming to IS 60947 1 & 3 fixing on Street light Pole with 32x4mm of MS Clamp and suitable size of nut, bolt and washers all as specified and directed. Cat Part No-#DTPN063 of Indoasian or equivalent in makes mentioned in list of makes in Appendix `C'
All as Per Item No-56 above but 100 Amps TPN Cat Part No-#DTPN100 of Indoasian or equivalent in makes mentioned in list of makes in Appendix `C'
Supply and fixing with replacement of MCB SP 6 to 32 Amps with PVC Enclouser fixing with pole or wall for individual street light/ security light control with suitable size of clamp nut , bolt and washers.make stanard, cat part No-DSMSCSPF006-032 and B88 Note: Rate of MS Clamp is include in Quoted Rates.
Material and labour for street light control board / box of size 0.50 X 0.50 X 0.20 m made out of 1.60 mm thick MS sheet fixed / mounted on pole by means of 2 Nos of FT clamps of size 25 X 3 mm comprising the following enclousers and connecting with suitable size of copper cable all as directed:- a) MCB, TPN, 40 Amps, - 01 No MAKE: CAT No DSMSCTNF040 OF STANDARD OR equivalent in makes mentioned in list of makes in Appendix `C' b) Timer switch, eletronic, ET 100 operating on 110 / 240 / 415 Volts, 50 Hz MAKE: CAT No SE92006 OF L&T OR equivalent in makes mentioned in list of makes in Appendix `C' c) Contactor ML 2, 32 Amps,415 Volt - 01 No MAKE: CAT No SS90701 OF L&T OR equivalent in makes mentioned in list of makes in Appendix `C'
Supply only in replacemet LED Drivers for 25 watt LED Fittings any type and any make as per sample etc complete all as specified and directed by Engineer-in-Charge
Supply only in replacemet LED surg protectors for 25 watt LED Fittings any type and any make as per sample etc complete all as specified and directed by Engineer-in-Charge
Supply only in replacemet LED Drivers for 30 watt LED Fittings any type and any make as per sample etc complete all as specified and directed by Engineer-in-Charge
Supply only in replacemet LED surg protectors for 30 watt LED Fittings any type and any make as per sample etc complete all as specified and directed by Engineer-in-Charge.
Supply only in replacemet LED Drivers for 60 watt LED Fittings any type and any make as per sample etc complete all as specified and directed by Engineer-in-Charge.
Supply only in replacemet LED surge protectors for 60 watt LED Fittings any type and any make as per sample etc complete all as specified and directed by Engineer-in-Charge.
M & L for repairing of Highmast panel box by replacing of MCB TPN, Timer switch, Contactor and also repairing the Panel box by welding of hinges, replacement of Lock etc complete all as specified and directed by Engineer-in-Charge. Note: (i) MCB TPN, Timerswitch and Contactor are paid separately. (ii) Rate Includes welding,Lock and keys , Painting in two coats of synthetic enamail and one coat of primer red oxide,
Supply and fix in replacement of MS Clamp 25x3mm with nut bolts and washers duely painted in two coats of aluminium paint and one coat of red oxide all as specified and directed by Engr-in -Charge.
Supply and fix in replacement of copper conductor XLPE insulated stranded , unarmoured ,extructed PVC type ST2 sheathed , 650/1100 volt graded as per IS 7098.of size 6 Sqmm 4 Core . Make Polycab cat part No- SISLV4X610693 or equivalent in makes mentioned in list of makes in Appendix `C'
Supply and fix in replacement of steel wire rope Grade AISI 316, 7/19 with 6mm dia. etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in replacement of copper conductor PVC insulated stranded , unarmoured , 650/1100 volt graded as per IS 7098.of size 2.5 Sqmm 5 Core . etc complete all as specified and directed by Engineer-in-Charge
M & L preparation of newly plastered surface and applying three coat of white wash on wall etc complete all as specified and directed by Engineer-in-Charge
M & L for replcement of Chain sprocket in Highmast Light etc complete all as specified and directed by Engineer-in-Charge
An amount of Rs 1,23,672.00.00 shall be deducted from BOQ on account of schedule of credit
Maruti Abhiyantriki
Ms. S.K. ASSOCIATES
R. T. Saluji
KAMINS CARE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .