Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.6 LAccepted-AOC | L1 | Accepted-AOC lowest bid quoted | |
| 2 | L2₹38.3 L+₹5.2 L (15.8%)Rejected-Finance | L2 | Rejected-Finance Highest Bid quoted |
Tender Value
₹48.4 L
EMD Value
₹97,000
Closing Date
22 Nov 2021, 6:00 pmClosed
GE (AF) Gurgaon
Gurgaon
ADDN ALTN TO OFFRS MESS KITCHEN TOILET FLOORING CHILDERN AND GYM HALL ADDN ALTN TO BLDG NO P TWO HUNDRED SIXTY AND ADDN ALTN TO STAFF MESS AT MOHD PUR STATION UNDER GE AF GURGAON
2021_MES_483814_1
CA NO GE/GUR-/NIT-65/2021-22
Open Tender
Miscellaneous Works
Piece-work
240 days
GE (AF) Gurgaon
ADDN ALTN TO OFFRS MESS KITCHEN TOILET FLOORING CHILDERN AND GYM HALL ADDN ALTN TO BLDG NO P TWO HUNDRED SIXTY AND ADDN ALTN TO STAFF MESS AT MOHD PUR STATION UNDER GE AF GURGAON
8 documents required · 8 mandatory
₹500
GE (AF) Gurgaon
₹97,000
28 Dec 2021
25 Oct 2021
24 Nov 2021
25 Oct 2021
22 Nov 2021
8 Nov 2021
Amount
Demolition of cement concrete (unreinforced) in ground floors and paving n. exc. 15 cm thickness (below or above ground level) complete all as specified.
M&L for Vitrified ceramic light shade tiles, 10 mm thick (square/ rectangular) polished ,area of each tile not exc. 0.36 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed or bedding layer of cement mortar 1:6 complete all as specified.
M&L for Virified Ceramic tiles light shade 10 mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed or bedding layer of cement mortar 1:6 complete all as specified.
M&L for Non-skid ceramic tiles,coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sq m but not exceeding 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed or bedding layer of cement mortar 1:6 complete all as specified.
M&L for 25mm th levelling course in Cement concrete 1:2:4 type B-0, (12.5 mm graded aggregate) complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified.
M&L for Glazed ceramic tiles, colour tile, in vertical surfaces, 450 X350 X 7 mm thick over 10 mm thick cement plaster in cement mortar 1:6 as backing of wall tiles etc., set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified.
M&L for chequered cement concrete tiles 30cmx30cm x 25mm thick, With grey cement and pigments, set, jointed and pointed in neat cement slurry ,over and including 20 mm thick screed bed or bedding layer of cement mortar 1:6, over new or existing sub-base in floors complete all as specified.
M&L for 50 mm thick Cement concrete 1:3:6 type C1, (20 mm graded aggregate), as in plinth protection, finishing cement concrete surface even and fair without using extra cement complete all as specified.
M&L for taking down cement plaster, any description, including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified.
M&L for 15mm thick rendering in cement mortar (1:6) on brick or concrete surface of any description, finished the surface even and smooth without using extra cement complete all as specified.
M&L for Rough cast plasster on brick walls consisting under coat of cement and sand mortar 1:3 not less than 10mmm thick and while it is still in plastic state the rough cast mixture consisting of crushed stone or fine gravel mixed of size 6mm with coarse sand and cement in the ratio 1:1:1 shall be applied and finish even completed all as specified & directed by Engr-in-charge.
M&L for 15mm thick rendering on fair faces of brick work, concrete surfaces in cement mortar 1:4 mixed with Liquid WPC, finished even and fair, complete all as specified. (Note : Liqiud WPC shall be measured and paid separately)
Supply only liquid water proofing compound, complete all as specified.
M&L for Preparation of new plastered surface and applying two coat of oil bound distemper with hand roller over primer to receive distemper over 3mm th wall care putty complete all as specified.
M&L for complete removal of existing treatment of wall surface and applying two coat of oil bound distemper with hand roller over primer to receive distemper over 3mm th wall care putty complete all as specified.
M&L for complete removal of existing treatment on walls including washing down, rubbing down and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. as specified.
M&L for Preparation of new plastered surface on walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. as specified
M&L for preparation of new wall surface, and applying two coat of white wash complete all as specified.
M&L for preparation of old wall surface, and applying one coat of white wash complete all as specified.
M&L for preparation of old ceiling surface, and applying two coat of white wash complete all as specified.
M&L for preparation of wall surface, and applying one coat of texture paint over a coat over one coat of primer and 1 mm thick wall care putty complete all as specified.
Dismantling Framed work timber scantlings 40 sq. cm and over in section, in any position complete all as specified.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified.
S&F rolled mild steel Fe -290(Gde E-165) for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.complete all as specified.
Dismantling of wall and ceiling boards( fibre, pulp, insulation etc.) or insulation boards/ slabs/ blankets, any thickness including cover fillets complete all as specified.
S&F Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with abbit wire mesh fixed to wooden frame (frame work to be paid separately) for sunk or rise moulding complete all as specified.
M&L for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre incl Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified.
S &F second class hardwood timber scantling Exc 3 & n. exc 6 sq.cm in plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or bradsall complete all as specified.
M & L for 12 mm thick Plywood, grade BWR, type BB, fixed with screws to timber frame work complete all as specified.
M & L for 4 mm thick Veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on ONE faces; fixed with screws to timber frame work complete all as specified.
M & L for three coats Bees-wax polishing on surfaces of any description, width or girth including cleaning and preparing the surface complete all as specified.
Dismantling of plain or corrugated steel sheeting, any guage, thickness from roof covering complete all as specified.
S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified.
Taking down and romoving Chowkats or frames not exc. 1.5 sq.m with shutter (without taking off shutters from the frames) complete all as specified.
Taking down and romoving Chowkats or frames exc 1.5 sq. m but not exc 4 sq. m with shutter (without taking off shutters from the frames) complete all as specified.
Taking down shutter exc 1.0 sqm but not exc. 2.0 sq.m each complete all as specified.
S&F 2nd class hard wood factory made 35 mm thick plain, framed, panelled shutters(any no of panels) with panels of timber flat on both sides (feather edge) or of veneered partical boaed medium density, wood pertical board with commercial face veneers; supply and fix two chowkats complete all as specified.
S&F 2nd class hard wood factory made 30 mm thick Glazed and sketon shutters, open rebeated and prepared to receive glass, gauze, etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SS Part-I, section 8, clause 8.24 (a) supplied and fited to chowkat complete all as specified.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC printed sheet & edges will be painted to match with printed sheet ,reinforced with M.S. Square tube, in opening as per specification & drawing complete all as specified.
S&F Factory made solid panel pvc door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and Plain colour PVC sheet & 5mm thick x15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm (900) used instead of exposed portion of PVC sheet beading in the frame at site as per specification & drawing complete all as specified.
S&F Plain (White) PVC Board Scratch and strain free (weight not less 9 Kg/Sqm) in Door, Shelves for Cup Boards or Kitchen Cabinets, both side laminated, 18/19mm thick as required, jointed by means of PVC Adhesive Solvent and fixed using Self-tapping Aluminium Screws, and Fixed-in-repairs,complete all as specified and as directed.
S&F Stainless Steel Silver chrome Door Handle 100mm long, suitable for fixing of Brass screws inside of the board etc, and Fixed-in-repairs,complete all as specified and as directed.
S&F Magnetic Door Catcher medium grade to hold approx 1000 mm opening cabinet door and Fixed-in-repairs complete all as specified and directed
S&F Stainless steel frog hinges suitable for kitchen cupboards 22 mm PVC Celuka Board etc for smooth movement, and Fixed-in-repairs,complete all as specified and as directed.
S&F Aluminum anodized powder coated frame fo doors, windows, ventilators powder coating (Min thickness of powde coating 50 microne) with one or more rebated including jointing cleats for fixing etc complete all as specified.
S&F Aluminum anodized powder coated door shuttes, aluminum section weighing 0.55 Kg/m including necessary, jointing cleats, glazing clip, rubber neoprene packing handles two nos in each door, hinges three nos in each leaf, anodized snap beading screws etc powder coating of any colour (Thickness of powder coating not less than 50 micron) complete all as specified and as directed.
S&F Aluminum anodized powder window and ventilator shutters side hung type without sash , aluminum sections weighinh 0.55 Kg/m including necessary jointing cleats, glazing clips, rubber packing anodized aluminum snap beading screws anodized aluminum fittings such as peg stays 150mm long (one no) hinges type B-21 100mm long (2 no) suitable handle (01 no) for each leaf ,powder coating of any colour (Thickness of powder coating not less than 50 micron) complete all as specified and as directed.
S&F Mortice brass lock vertical type size 100mm with 4 levers complete all as directed.
S&F floor spring double action hydraulically regulated made up of min 1.25mm thick aluminum alloy sheet foundation box, main body with stainless steel cover governing pivot made of brass other parts made of mild steel heavy duty ISI Marked fixed in position, complete all as specified and as directed.
M&L for two coats of synthetic enamel paint over one coat of pink primer including preparation on wood or wood based surfaces of any description on new surfaces exc. 10 cm width or grith complete all as specified.
M&L for one coats of synthetic enamel paint including preparation on wood or wood based surfaces of any description on old surfaces exc. 10 cm width or grith complete all as specified.
M&L for one coats of synthetic enamel paint including preparation on steel or steel based surfaces of any description on old surfaces exc. 10 cm width or grith complete all as specified.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified.
S&F 4mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified.
S&F 300 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified
S&F 100 mm Butt hinges, Medium weight, cold rolled mild steel, and fixed complete all as specified.
S&F 150 mm Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified.
S&F 150 mm Aluminium handles, cast type, anodised complete all as specified.
S&F 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified .
Demolition Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified.
M& L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in set in CM 1:4 complete all as specified.
Demolition of cement concrete (reinforced) in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified.
M&L for reinforced cement concrete (Nominal Mix) 1:1.5:3 Type A1 (20 mm graded aggregate) as in lintel over 1.5 M span, Beam etc complete all as specified.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified.
S&F in repair Vitreous china wash down water closet pan (pedestal pattern), white, including flush pipe of polyethylene of low or high density or PVC 32 mm dia., plastic water closet seat closed pattern with cover and hinging device and trap with connection in repairs complete all as specified.
S & F in repairs Vitreous Chine wash down water closet pan single piece with UF seat cover hinges, fixing accessories set, cistern fitting of size 365x655x760 with S trap (Make : Jaquar, Modle LYS-WHT-38851S , Cera- S1013119 or equivalent) complete all as specified and directed.
S&F Chromium plated jet for EWC complete all as specified.
S&F 10 Ltrs PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and connections to pipes and fixing of chain and pull, or lever, if any in repairs complete all as specified.
S&F Vitreous china wash basin, white, flat back, size 550 X 400 mm including fixing with brackets exclusive of fixing of supply and waste pipe and 32 mm chromium plate waste fitting with long screwed shanks and fly-nuts complete all as specified.
S&F PVC connections 15 mm size with PTMT nuts of length 600 mm in repairs complete all as specified.
S&F 15 MM Bib taps, cast copper alloy, fancy type, chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15 mm bore steel tube fixed in repair complete all as specified.(Make: Jaqure, Modle no FLR-5047,CERA-F1018151 or equivalent)
S&F 15 mm bore Brass CP mixer for WHB for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified. (Make: Jaqure, Modle no FLR-5167NB , F2010461 or equivalent)
S&F 15MM Stop valves, cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed to15 mm bore steel tube in repairs complete all as specified.(Make: Jaqure, Modle no FLR-5053N , F2004351 or equivalent)
S&F 15 mm bore Brass CP mixer for wall for mixing hot & cold water with provision for overhead shower with 115mm long bend pipe on upper side , connecting & wall flange fancy type, cast copper alloy, chromium. (Make: Jaqure, Modle no FLR-5273 UPR , CERA-F1014401or equivalent)
S&F Brass chromium plated shower rose 125mm size for iron pipe or for unions and fixed to 15 mm bore steel tube in repairs complete all as specified.
S&F Aluminium anodised tubular towel rail, 20 mm dia., D type, 60 cm long between flanges in repairs complete all as specified.
S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified.
S&F Soap dish, cast copper alloy, chromium plated with screws complete all as specified.
S&F 75 mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified.
S&F 75 mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified.
Taking up or down steel tubing 15 mm bore, and connections, including cleaning for re-fixing or removal to store in repairs complete all as specified.
S&F 15 mm bore, steel water tubing, medium grade, galvanized, with all fitting and fixed complete to walls and ceiling or laid into floor in repairs complete all as specified.
Taking up or down steel tubing 20 mm bore, and connections, including cleaning for re-fixing or removal to store complete all as specified.
S&F 20 mm bore, steel water tubing, medium grade, galvanized, with all fitting and fixed complete to walls and ceiling or laid into floor in repairs complete all as specified.
S&F 1000 Ltrs capacity, rotational moulded polyethylene water storage tanks 3 layer (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part – I, including ball brass valves, high pressure with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed to 20 mm bore steel tube and dismantling existing water tank and removing complete all in repair as specified.
All as per item No - 89.00 hereinbefore but area exc 1 sqm but n exc 2 sqm.
S &F 12mm thick toughened glass pane fixed to opening with stainless steel cleats as directed by Engr-In-Charge.
M&L for 20mm thick Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of ranite stone including grinding and polishing complete incl 20mm thick screed bed in CM 1:6 complete all as specified and dircted by Engr-in-Charge.
M&L for machine cut kota stone slab 20-25 mm thick in floor laid and jointed with grey cement slurry mixed with pigment to match shade of the slab including cutting, waste, rubbing and Mirror polishing over and including cement screed bed 20 mm th in CM 1:6 complete all as specified.
M&L for machine cut kota stone slab 20-25 mm thick in skirting jointed with grey cement slurry mixed with pigment to match shade of the slab including cutting, waste, rubbing and polishing over over 10 mm thick cement plaster in cement mortar 1:6 as backing of wall tiles complete all as specified.
S&F flase ceiling at all heights with GRG (Glass Fiber Reinforced Gypsum) false ciling tiles of sizes 595x595 mm of approved texture , design and patterns having moisture content less than 2% , humidity resistance of 99% NRC 0.85 (with 50mm thick Glass Wool) as per IS 8225:1987, Noncombustilble as per BS 476 (Part-4) -1970 and light reflectance of 75-85 % to be laide in true horizontal level suspended on inter-locking metal T-Gride of hot dipped galvanized iron section of 0.30 mm thick(Galvanized @ 120GMS /SQM Incl both sides)compprising of main T-runners of sizes 24x32 mm of length 3000mm ,cross T-of size 24x26 mm of length 1200mm and secondary intermediate cross T of size 24X26 mm of length 600mm to form grid module of size 600x600 mm suspended form ceiling using galvanized mild steel items (galvanized @ 80gm /sqm ) i.e 50 mm long, 8 mm outer diameter M-6dash fasterner, 6 mm dia fully threaded hanger rod up to 1000 mm length and L-shapenlevel adjuster of size 85x25x2 mm. Glavanized iron perimeter wall angle of size 24x24x0.40 mm of lrgth 3000mm to be fixed on periphery wall/ partition with the help of plastic eawl plugs at 450mm center to center and 40mm long dry wall SS screws. The work shall be carried out as per specification and as directed by Engr-In-Charge complete all as specified.
S&F Plain (White) PVC Board Scratch and strain free (weight not less 9 Kg/Sqm) in Door, Shelves for Cup Boards or Kitchen Cabinets, both side laminated, 18/19mm thick as required, jointed by means of PVC Adhesive Solvent and fixed using Self-tapping Aluminium Screws, and Fixed-in-repairs,complete all as specified and as directed.
S&F Stainless Steel Silver chrome Door Handle 100mm long, suitable for fixing of Brass screws inside of the board etc, and Fixed-in-repairs,complete all as specified and as directed.
S&F Magnetic Door Catcher medium grade to hold approx 1000 mm opening cabinet door and Fixed-in-repairs complete all as specified and directed
S&F Stainless steel frog hinges suitable for kitchen cupboards 22 mm PVC Celuka Board etc for smooth movement, and Fixed-in-repairs,complete all as specified and as directed.
M&L for Preparation of new plastered surface and applying two coat of oacrylicemulsion paint with hand roller over primer to receive distemper over 1 to 1.5mm th wall care putty complete all as specified.
M&L for complete removal of existing treatment of wall surface and applying two coat of acrylic emulsion paint with hand roller over primer to receive distemper over 1mm to 1.5mm thick wall care putty complete all as specified.
S&F Aluminum anodized powder coated 3 track sliding window shutters of 2 Nos of glass shutter,gauzed shutter, aluminum section weighing n. less than 0.30 Kg/m including necessary, jointing cleats, glazing clip, rubber neoprene packing handles two nos in each shutters, hinges three nos in each leaf, anodized snap beading screws etc powder coating of any colour (Thickness of powder coating not less than 50 micron) complete all as specified and as directed.
S&F 4.8mm thick Sheet glass, ordinary quality and glazing fixed with aluminium door /window shutter in square n exc 0.5 sq. m in each panefixed in position, complete all as specified and as directed.
S&F in repairs galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm, complete all as specified and directed.
M&L two coats of synthetic enamel paint including preparation on steel or steel based surfaces of any description on old surfaces exc. 10 cm width or grith complete all as specified.
S&F Stainless steel sink with draining board,made out of 1.00mm thick sheet for kitchen or laboratory with plug, washers waste pipe, cast iron cantilever brackets,connecting union overall size 915mmx460mm with bowl size 410mm x330mm x 160mm complete all as specified and as dircted by Engr-in-Charge.
Taking down carefully aluminium/copper wiring of any size (for light, fan, socket or power etc complete) ( fittings such as switches, sockets, ceiling roses, pendent holders regulators, tube lights etc to be measured and paid separately) and making good disturbed surfaces of wall, roof etc to match with existing surface complete all as specified and as dircted by Engr-in-Charge.
Taking down carefully by unscrewing from the boards/outlets boxes fittings and fixtures such as switches, sockets ceiling, rose, lamp holders, tube light fittings, regulators etc and making good of disturbed surfaces complete all as specified and as dircted by Engr-in-Charge.
Taking down unserviceable main switches MCB DB’s incl MCB SP/SPN/TPN of any make and type including teakwood board etc complete and making good the disturbed surfaces including colour washcomplete all as specified and as dircted by Engr-in-Charge.
Taking down ceiling fans / wall mounted fans of any size / sweep after disconnecting the wire fro existing ceiling rose and refixing the same after painting the same with synthetic enamel paint by spray machine including filter after cleaning dust, oiling and greasing complete including providing flexible twin core copper conductor stranded cord from ceiling rose to connecting of fan complete all as specified and as dircted by Engr-in-Charge.
Taking down exhaust fans of any size / sweep after disconnecting the wire from existing ceiling rose and refixing the same after painting the same with synthetic enamel paint by spray machine including filter after cleaning dust, oiling and greasing complete including providing flexible twin core copper conductor stranded cord from ceiling rose to connecting of fan complete all as specified and as dircted by Engr-in-Charge.
Taking down carefully sub main wiring complete with conductor, cast conductor and PVC casing and coping and make good to the disturbed surfaces complete all as specified and as dircted by Engr-in-Charge.
M&L for point wiring for light/fan points controlled by two, two way switch using 1.5 Sqmm nominal cross sectional area copper conductor multistranded, PVC insulated unsheathed FRLS cable in and including Heavy duty 2mm thick ISI marked concealed conduit of suitable dia complete with all ISI marked PVC conduit accessories/ fittings and 1.5 sqmm nominal cross sectional area stranded copper conductor PVC insulated unsheathed FRLS green colour cable earth wire and connecting to earth dolly etc. complete all as specified and directed. The point wiring shall include the wiring of light/ outlets of any length from the distribution board via switch to the point complete all as specified and as dircted by Engr-in-Charge.
All as per item No 113 hereinbefore but One socket outlet 5 Amps on the same board.
All as per item No 113 hereinbefore but One 3 pin socket outlet 5 Amps independent.
All as per item No 113 hereinbefore but One 3 pin 5 amps socket outlet indepen dent but below the switchboard of light points in the same vertical plane
All as per item No 113 hereinbefore but with 2.5 Sq mm two single core and 2.5 Sq mm one single core as earth wire for 15 Amps independent socket .
All as per item No 113 hereinbefore but socket outlet independent but below the switch board of light points in the same vertical plane with 4.00 Sq mm two single core and 2.5 Sq mm one single core as earth wire for 15 Amps.
S&F piano switch flush type 5 Amps 230 Volts single pole one way completed all as specified and as directed by Engr-in-Charge.
S&F piano switch flush type 15 Amps 230 Volts single pole one way completed all as specified and as directed by Engr-in-Charge.
S&F socket outlet combination 2 in 1, 3 pin 5 Amps flush type universalcompleted all as specified and as directed by Engr-in-Charge.
S&F socket outlet combination 2 in 1, 3 pin 15 Amps flush type universal completed all as specified and as directed by Engr-in-Charge.
S&F ceiling rose surface bakelite 3 terminal with base plate completed all as specified and as directed by Engr-in-Charge.
S&F steped type electronic fan regulator flush type on the existing phenolic laminatedsheet etc completed all as specified and as directed by Engr-in-Charge.
M&L for submain wiring with 2 single core PVC FRLS insulated, unsheathed, multi stranded flexible copper conductor 1100 volts grade cables 6 Sqmm drawn through rigid PVC heavy grade concealed conduits incluidng 4 Sqmm PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified, directed and shown on drgs. (Note :- Two runs of cables and continuous earthwire in conduit will be measured as one length of sub main .)
M&L for submain wiring with 4 single core PVC FRLS insulated, unsheathed, multi stranded flexible copper conductor 1100 volts grade cables 4 Sqmm drawn through rigid PVC heavy grade concealed conduits incluidng 2.5 Sqmm PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified, directed and shown on drgs. (Note :- four runs of cables and continuous earthwire in conduit will be measured as one length of sub main.)
S&F LED tube light fitting 1x22Watt Saviour slim energy saving channel suitable for LED lamps with standerd fittings all as specified and directed.
Supplying, fixing ,testing and commissioning of pre-wired 36 watt LED CW light fitting of size 600x600mm approved make, complete with CRCA housing,replaceable driver, high quality difuser etc, all as specified and as directed. The rates shall include all fixing accessories that are required to make the installation complete in all respects including the required GI flexible conduit with wiring from true ceiling to false ceiling for fixtures recessed in false ceiling,providing connecting wires and channel support wherever required,Internal wiring between accessories,Self interlocking connector blocks for connecting the wires from fixtures to the points,.Earthing of fixtures with 1.5 sq. mm. FRLS PVC insulated copper conductor wire, and other components and fixing accessories wherever required.
S&F landscaping wall light sun/prismatic made up of unbreakable carbonate, suitable on wall /surface mountinglamp holder with 12 w LED lampcomplete all acessoris and fitiing all as specified and directed.
S&F MCB DB SPN 12 way sheet metal enclosure double door with 200 Amps common bus bar and neutral link compete to fixtures.
S&F MCB DB TPN 4 way sheet metal enclosure double door with 200A common bus bar and neutral link complete to fixtures, complete all as specified and directed by Engr-in-Charge.
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of TPN four poles and 63 AMP current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) of SPN poles and 63 AMP current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
S&F Metal enclosure Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 32 amps complete all as specified and directed.
S&F in repair GI pipe light grade 40mm bore in trenches/wall/poles for protection of cable complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4core complete all as specified & directed by Engineer - In - Charge.
M & L for excavation in trenches n.exc 1.5 m wide and n exc 1.5 m depth for laying of cable and getting out in hard/dense soil complete all as specified and directed.
Returning filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm complete all as specified and as directed.
Removal of excavated material/surplus soil to a distance n exc 1.50m and depositing where directed at a level n exc 50m above the starting point complete all as specified and as directed.
Supply and laying sand in trenches for protection of cable sand cushioning to cable 8 cm thick below cable and 15 cm thick above cable in layers all as specified and as directed.
M&L for brick protection with sub class 'B' old bricks laid dry flat 23cm in width over sand cushioning in trenches as perpendicular to the direction of underground cable complete all as specified and as directed.
supply and lay in treches for fixed Wall/floor or passing through ducts GI tube light grade of sizes upto 80mm as per site requirement for protection of UG cable with necessary fittings all as specified as directed.
M&L for carrying out horizontal boring below roads/PCC hard standing/Drain suitable Up to 100mm dia GI pipe as per site requirement all as specified as directed for inserting GI pipe of the following sze with a depth upto 1.5m & length of road upto 12m of the follwing size of bore complete all as specified and as directed.
Material & Labour for concealed point wiring with single core PVC insulated and unsheathed 1100 volts grade cable with multistranded copper conductor of size 1.5 Sqmm nominal area drawn through & including non metallic rigid PVC conduit (circular/flat pvc conduit), medium duty not less than 20 mm dia concealed in wall/fixed on wall/ceiling with GI saddles , GI screws , rawl plugs with all fittings including tees , modular junction boxes including fixing GI gang box of any module not less than 3.15mm thickness flushed in wall with hylem cover sheet of suitable size for mounting switches , sockets & regulators & drawing through continuous earth wire of PVC insulated unsheathed 1100 volts grade cable with copper conductor solid conductor of size 1.5 sqmm for one light or fan point complete all as specified & directed by Engineer -In-Charge. Note: Cost for cutting chases in any type of wall/ceiling and supply & flushing conduit pipe, junction box, tee, PVC flexible pipe, cover plates, back plate and GI gang box ( any qty, Nos & module) and making good to match the existing surface shall be deemed to be included in the quoted rate.
All as per item No 145 hereinbefore but two light points controlled by one switch.
All as per item No 145 hereinbefore but three light points controlled by one switch.
All as per item No 145 hereinbefore but five light points controlled by one switch.
All as per item No 145 hereinbefore but One socket outlet 5 Amps on the same board.
All as per item No 145 hereinbefore but One 3 pin socket outlet 5 Amps independent.
All as per item No 145 hereinbefore but One 3 pin 5 amps socket outlet indepen dent but below the switchboard of light points in the same vertical plane
All as per item No 145 hereinbefore but with 2.5 Sq mm two single core and 2.5 Sq mm one single core as earth wire for 15 Amps independent socket .
All as per item No 145 hereinbefore but socket outlet independent but below the switch board of light points in the same vertical plane with 4 Sq mm two single core and 2.5 Sq mm one single core as earth wire for 15 Amps.
S&F Modular switch 1 way 6A, 1 module 230 Volts complete all as specified and directed.
S&F Modular switch 1 way 10A, 1 module 230 Volts complete all as specified and directed..
S&F Modular switch 1 way 16A, 1 module 230 Volts complete all as specified and directed..
S&F Modular socket outlet combination 2 in 1, 3 pin 5 Amps flush type universal.
S&F Modular socket outlet combination 2 in 1, 3 pin 15 Amps flush type universal.
S&F Modular Fan step regulator, 120W - 2 module steped type electronic fan regulator.
Supply and fixing round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete.
Supply and fix in replacement of factory made epoxy polyster powder coated distribution board SP&N 12 way with 200 Amp rated fabricated from minimum 1.6 mm thick CRCA sheet with double door (IP-43 protection) fixed flush to wall and standard DIN rail, earth bar and cable ties for cable management, suitable for one incoming TPN MCB and 9 outgoings SP MCB complete all as specified and confirming to IS: 8623 (Make: Legrand /Siemens/Schenider). Note: Cutting on wall and taking out old one and then flushing new DB and making all the connection as before and any accessories required to fix the DB including making good the disturbed surface is deemed to be included in quoted rate.
BLANK
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of TPN four poles and 100 AMP current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed.
All as per item No. 163 above but with TPN 4P 40A complete all as specified and directed.
BLANK
Supply and fixing Rigid non-metallic PVC conduit 25 mm dia exclusive of boxes (junction/terminal) but inclusive all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and directed.
Supply, fixing and testing round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. Earthing of fixtures with 1.5 sq. mm. FRLS PVC insulated copper conductor wire, and other components and fixing accessories wherever required.
M&L for submain wiring with 3 single core PVC FRLS insulated, unsheathed, multi stranded flexible copper conductor 1100 volts grade cables 6 Sqmm drawn through rigid PVC heavy grade concealed conduits incluidng 4.00 Sqmm PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified, directed and shown on drgs. (Note :- three runs of cables and continuous earthwire in conduit will be measured as one length of sub main.)
Supply and fixing 415V 10KA 'B' 40 Amps curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning.
M&L Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and as directed.
P R Constructions
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .