Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹18.3 LAccepted-AOC 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | 1 | Accepted-AOC Being L-1 | |
| 2 | 2₹19.7 L+₹31,010 (1.60%)Rejected-Finance KE 100 B KAVERI KUNJ PHASE I KAMLA NAGAR AGRA 282005 | AGRA | AGRA | UTTAR PRADESH | 282005 | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹19.7 L+₹33,652 (1.74%)Rejected-Finance 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | 3 | Rejected-Finance Being other than L-1 | |
| 4 | 4₹20.0 L+₹60,950 (3.15%)Rejected-Finance NAGLA UDHA NEAR PRIMARY SCHOOL POST DHANOLI AGRA UP AGRA 282010 | AGRA | AGRA | UP | 282010 | 4 | Rejected-Finance Being other than L-1 | |
| 5 | 5₹20.7 L+₹1.3 L (6.79%)Rejected-Finance | 5 | Rejected-Finance Being other than L-1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
19 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Adm Area Agra 282008
GE (AF) Adm Area Agra 282008
REPAIR MAINT OF LT UG CABLES LT POLES LT OH LINES STAY ASSEMBLY SWITCH GEARS AND OTHER CONNECTED WORKS AT CAMP AREA UNDER GE AF ADM AREA AT AF STATION AGRA
2023_MES_605322_1
8000-2064/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF Station Agra
Class E
cat b i
8 documents required · 8 mandatory
₹500
GE AF Adm Area Kheria Agra
₹40,000
Yes
12 Aug 2023
23 Jun 2023
21 Jul 2023
23 Jun 2023
19 Jul 2023
7 Jul 2023
23 Jun 2023 - 6 Jul 2023
Amount
Excavating in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation etc or for laying for cables etc n.exc 10 sqm on plan and getting out in any type of soil including removal of sand, bricks/PCC covers laid for cable proection complete all as specified and directed.
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layers not exc. 25 cm in any type of soil complete all as specified and directed.
Removing surplus excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
Supply & laying in replacement of brick, double walled corrugated (DWC) HDPE split pipe in 2 m lenght conforming to IS 16205 Pt-24 of approved colour complete with fittings for cable protection of size 103 mm inner dia and 120 mm outer dia complete all as directed.
Supply & laying in replacement of brick, double walled corrugated (DWC) HDPE pipe conforming to IS 16205 Pt-24, inner plain, 450 N of approved colour complete with fittings for cable protection of size 50 mm inner dia and 63 mm outer dia complete all as directed.
Taking out old unserviceable LT UG cables of size 25 to 120 Sqmm 3.5/4 Core from trenches, poles/walls and floor for removing of fault or re-laying (Necessary earth work shall be measured and paid under respective item of Schedule) complete all as directed.
Supply and Laying including testing in floor/trenches or fixed on pole/wall XLPE LT UG cable PVC insulated, bedded, galvanised steel strip or wire armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 120 Sqmm 3.5 core complete all as specified and directed.
Supply and Laying including testing in floor/trenches or fixed on pole/wall XLPE LT UG cable PVC insulated, bedded, galvanised steel strip or wire armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 95 Sqmm 3.5 core complete all as specified and directed.
Supply and Laying including testing in floor/trenches or fixed on pole/wall XLPE LT UG cable PVC insulated, bedded, galvanised steel strip or wire armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 70 Sqmm 3.5 core complete all as specified and directed.
Supply and Laying including testing in floor/trenches or fixed on pole/wall XLPE LT UG cable PVC insulated, bedded, galvanised steel strip or wire armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 25 Sqmm 4 core complete all as specified and directed.
M&L for replacement of existing unsv cable straight through joints with straight through joints (heat shrinkable) any type suitable for XLPE 1100 Volts aluminium conductor cable of size 70-240 Sqmm 3.5 core and testing after jointing. Note:- Rate quoted including necessary excavation, returning filling, removal etc for taking out loop/ cutting of burnt cable for required length for making end joint.
All as per item No. 11 but for cable size 25-50 Sqmm 3.5/4 core
M&L for drilling suitable dia horizontal bore holes for insertion / laying of 50 to 150 mm GI/ HDPE pipe of any description below/under road surface/floors etc. with using mechanical or manual devices as required at site including making good disturbed surface to match with the existing streta after laying pipes complete all as specified and directed.
Clearing of bushes/small plants upto root level around and surroundings areas E/M installations (i.e. Two Pole/ Four structures, outdoor-substation yards & other Misc E/M installations etc.) soft and loose soil including surface dressing n.exc 15 cm deep and removing debris to a distance n.exc 50 m complete all as directed
Restringing (without taking down) of existing ACSR’s conductorsand earth wires including cradles, of any description, size & shape and in any position, as in LT/HT overhead lines, on existing poles, including opening of connections and binding wires, restringing and tightening of conductors/earth wire in position, removing sag, binding to insulators with new aluminum wire, making and connecting jumper connections etc. including testing complete all as specified and directed. The quoted rates shall be deemed to include the following provisions also :- (i) Setting/adjusting etc in position of cradles. (ii) Old serviceable spacers of ACSR conductor shall be reused and fixed as directed by Engineer-in-Charge.
Material & labour pin type porcelain, vitreous, white, brown or green insulator including one GI nut bolt 100 mm height 65 mm dia for 1100 Volt complete including taking down old unserviceable insulator all as specified and directed.
Material & labour Shackle type, porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts for 1100 Volt 100 mm height & 115 mm dia with GI straps 31x5 mm & dia of volt 14 mm complete including taking down old unserviceable insulator complete all as specified and directed.
Trimming up of tree branches upto 3 mtr all around LT overhead lines, removing cut branches from site as directed. Note :- (i) The overhead lines will be kept clear from all trees by trimming of tree branches with 3 mtr all around the line. (ii) Necessary permission will be obtained from department by contractor one day prior to trimming in particular area and shut down of that area will be arranged by department.
M&L for prepration of old painted surface of steel tubular poles of 9 mtr long including cross arms, cable protection pipe, bus bar box and painting of complete area with one coat of aluminum paint from 1.5 mtr above ground level to top of pole and a height of 1.5 mtr from the ground level synethetic enamel paint in alternate strips / layer (30 cm wide) with white and blue colour including writing the pole number in white letters on black background and cleaning /cutting the grass/bushes at a radius of 2 mtr surrounding the pole all as directed.
M&L in replacement of existing unsv MCCB 250 Amps current carrying capacity 25 KA, AC 415 Volts Ics= 100% Icu, four pole with magnetic/ thermal adjustable type setting complete all as specified and directed.
M&L in replacement of existing unsv MCCB 160 Amps current carrying capacity 16 KA, AC 415 Volts Ics= 100% Icu, four pole with magnetic/ thermal adjustable type setting complete all as specified and directed.
M&L in replacement of existing unsv MCCB 630 Amps current carrying capacity 50 KA, AC 415 Volts Ics= 100% Icu, four pole with magnetic/ thermal adjustable type setting complete all as specified and directed.
Taking down existing old unsv LT panel board with all accessories and Supply, installing, erecting, commissioning and testing new factory made LT panel board cubical in door type of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 2 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement, panel base of angle iron 50x50x6 mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including TPN Aluminium bus bar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN bus bar shall be insulated with colour coded heat shrinkable sleeves and shall be mounted on F class insulators. All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN Aluminium bus bar of rating not less than 1.5 times rated capacity of individual outgoing feeders. All control wiring shall be with FRLS PVC insulated 6 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm and complete mounted or fixed on PCC foundation 0.45 mtr above floor and cable connection with suitable size of copper lugs and suitable size chrome plated glands provided for incoming and out-going cables comprising the following :-
Taking down existing old unsv LT panel board with all accessories and Supply, installing, erecting, commissioning and testing new factory made LT panel board cubical out door type of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement, panel base of angle iron 50x50x6 mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including TPN Aluminium bus bar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN bus bar shall be insulated with colour coded heat shrinkable sleeves and shall be mounted on F class insulators. All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN Aluminium bus bar of rating not less than 1.5 times rated capacity of individual outgoing feeders. All control wiring shall be with FRLS PVC insulated 6 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm and complete mounted or fixed on PCC foundation 0.45 mtr above floor and cable connection with suitable size of copper lugs and suitable size chrome plated glands provided for incoming and out-going cables comprising the following :-
Taking down existing old unsv LT panel board with all accessories and Supply, installing, erecting, commissioning and testing new factory made LT panel board cubical out door type of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement, panel base of angle iron 50x50x6 mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including TPN Aluminium bus bar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN bus bar shall be insulated with colour coded heat shrinkable sleeves and shall be mounted on F class insulators. All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN Aluminium bus bar of rating not less than 1.5 times rated capacity of individual outgoing feeders. All control wiring shall be with FRLS PVC insulated 6 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm and complete mounted or fixed on PCC foundation 0.45 mtr above floor and cable connection with suitable size of copper lugs and suitable size chrome plated glands provided for incoming and out-going cables comprising the following :-
M&L for replacament of existing old unsv earthing with steel earth plate electrode of size 600x600x6mm thick buried directly in ground to a depth not less than 3.25 mtr deep below normal ground level with top edge of the earth plate not less than 2.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earth lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full lenght of earth plate, 40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI watering pipe light grade with funnel and wire mesh, complete all as per SSR with PCC chamber, 50mm thick 30 x 30 cm size RCC cover in 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8mm dia TMT bar @ 80mm c/c both way with angle iron frame allround made of AI 40 x 40 x 4 mm, adequate qty of charcoal dust and salt layers all around the earth plate, including earth work in any type of soil, removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as shown on electric plate No 03 of SSR -2009 Part I complete all as specified and directed.(Note: Excavation and earth work is deemed to be included in the rates quoted).
M&L for disconnecting of burnt/damaged cables from panels/ junction boxes etc. cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tapes etc. and reconnecting using new nuts/bolts/washers/ thimble/lugs etc. and restoring three phase and neutral connection in the junction box for 10 to 240 Sqmm 2/3.5/4 core size LT underground cable complete all as specified and directed. Note:- Earth work required for extending the incoming/outgoing cable in junction box/ panel etc. shall deemed to be included in unit rates.
M&L for hard gravel with specific gravity not less than 2.5, free from clay, sand, loam, dust and organic impurities of any kind, acid solubility not more than 10 %, particle size of gravel between 20 mm to 30 mm, alongwith provide 02 layers of plastic papers under the gravels including removing old gravels of any size complete all as specified and directed.
M&L for replacement of existing unsv Bus Bar Panel with new Bus Bar Panel of capacity 250 Amps copper bus bar 04 Nos, 4 way with fixed on insulator welded with iron angle of size 40 x 40 x 6 mm thick grounting in floor, 30 x 30 x 45 cm depth grounting with PCC 1:3:6 upto ground level all as specified and directed. Make-Havells Cat Part No IHBC025004 or equivalent in Legrand/L&T.
M&L for replacement of existing unsv Bus Bar Panel with new Bus Bar Panel of capacity 200 Amps copper bus bar 04 Nos, 4 way with fixed on insulator welded with iron angle of size 40 x 40 x 5 mm thick grounting in floor, 30 x 30 x 45 cm depth grounting with PCC 1:3:6 upto ground level all as specified and directed. Make-Havells Cat Part No IHBC020004 or equivalent in Legrand/L&T.
M&L for replacement of existing unsv Bus Bar Panel with new Bus Bar Panel of capacity 400 Amps copper bus bar 04 Nos, 4 way with fixed on insulator welded with iron angle of size 40 x 40 x 5 mm thick grounting in floor, 30 x 30 x 45 cm depth grounting with PCC 1:3:6 upto ground level all as specified and directed. Make-Havells Cat Part No IHBC040004 or equivalent in Legrand/L&T.
M&L for replacement of existing unsv Bus Bar Panel with new Bus Bar Panel of capacity 100 Amps copper bus bar 04 Nos, 4 way with fixed on insulator welded with iron angle of size 40 x 40 x 5 mm thick grounting in floor, 30 x 30 x 45 cm depth grounting with PCC 1:3:6 upto ground level all as specified and directed. Make-Havells Cat Part No IHBC010004 or equivalent in Legrand/L&T.
M&L for PCC 1:3:6 Type C-1 (using 20 mm graded stone aggregate) as in coping/pedestal of poles/ foundation including necessary form work and finishing the surface with rendering 5 mm thick in cement mortar 1:4 finished even and smooth withot using extra cement complete all as specified and directed.
M/s Sumer Associates
M/s SCHOLASTIC ENTERPRISES
MUKTA AND COMPANY
M/s Pooran Singh and Company
Balaji Associate
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .