Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹37.4 LAccepted-AOC | L-1 | Accepted-AOC lowest bidder | |
| 2 | L-2₹44.1 L+₹6.0 L (15.7%)Rejected-AOC | L-2 | Rejected-AOC other than lowest bidder | |
| 3 | L-3₹46.8 L+₹8.7 L (22.7%)Rejected-AOC | L-3 | Rejected-AOC other than lowest bidder | |
| 4 | L-4₹46.8 L+₹8.7 L (22.9%)Rejected-AOC 5 A LANE 1 GREATER KAILASH JAMMU J K 180011 | JAMMU | JAMMU AND KASHMIR | 180011 | L-4 | Rejected-AOC other than lowest bidder | |
| 5 | L-5₹47.2 L+₹9.1 L (23.8%)Rejected-AOC | L-5 | Rejected-AOC other than lowest bidder |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
6 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh Tanuj Bagla, EE
GE Kaluchak Pin-900673 C/O 56 APO
REPAIR OF ROOFING APP, SUNKEN FLOORING, CHAJJA AND RAIN WATER PIPES AT KALUCHAK MIL STN UNDER GE KALUCHAK
2023_MES_627477_1
GE/KC/NIT-47/2023-24
Open Tender
Civil Works
Item Rate
120 days
Kaluchak
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹98,000
Yes
27 May 2024
8 Nov 2023
8 Dec 2023
8 Nov 2023
6 Dec 2023
22 Nov 2023
8 Nov 2023 - 15 Nov 2023
Amount
Demolition of brick work or stone / boulder masonry including all quoins, arches, pillars, etc. built in cement mortar or cement lime mortar complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thick (Below or above ground level) complete all as specified and directed.
Demolition of reinforced cement concrete in any position and any description including cutting of reinforcement bars to facilitate demolition complete all as specified and directed.
Dismantling of structural steel work including doors, gates but excluding framed trusses complete all as specified and directed.
Dismantling of plain or corrugated AC sheeting, any gauge, thickness including Nainital or similar pattern roof covering complete all as specified and directed.
Taking down cement or cement lime plaster from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. complete all as specified and directed.
Dismantling of water tank exc. 500 Litre but not exc. 1000 Litre capacity complete all as specified and directed.
Dismantling of water tank exc. 1000 Litre but not exc. 2000 Litre capacity complete all as specified and directed.
M & L for providing plain cement concrete type B-1, 1:2:4, (using 20 mm graded stone aggregate), as in copings, bed block for embedding hold fasts, kneelers, apex stones, bed plates, water throughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
M & L for providing plain cement concrete, type D-2, 1:4:8 (using 40 mm graded stone aggregate) as in sunken, filling and mass concrete complete all as specified and directed.
M & L for brick work with sub class ‘B’ old size bricks straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L for brick work with sub class ‘B’ old size bricks (EXCEPT BRICKS) straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed. NOTE: - OLD BRICKS OBTAINED FROM DEMOLITION SHALL BE USED UNDER THIS ITEM.
S & F of wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work onforming to Fe-290 Gde E-165 complete all as specified and directed.
S & F of rolled mild steel sections as in roof trusses (framed), trussed, purlins, crane gantry, rails, fastening, heavy bracket framing (Beam, tee, angle, channel or flat section), including distance pieces, cleats etc. confirming to Fe 410 -W(Gde-E- 250) quality-B including cutting, welding etc. complete all as specified and directed.
S & F of mild steel framed work such as gate grills, gratings etc. with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, frame work of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S&F for suspended false ceiling system using 4mm thick high pressure steam cured fibre cement pre-primed textured varient E-board (classic), ISI marked, conforming to IS:14982-2000 over and including GI snap grid frame work for false ceiling, grid size 605 x 605 mm with GI angle of size 24x24mm, main runner ‘T’ of size 24x38mm, secondary runner ‘T’ of size 24x28mm with 6mm GI wire with butterfly clips as hangers for leveling, fastners, supports, plugs to walls/joists etc , hangers to be fixed with approved rawl plug, level adjusters and screwsa etc, last hanger at the end of each runner shall not be greater than 450mm from adjacent wall all as per manufacturer’s Instructions including making holes, cutting chasis and making good existing walls in cement mortar 1:3 or PCC 1:2:4 type B1, complete all as specified and directed. Note : All steel members shall be hot dipped galvanised with zinc coating not less than 120 gm/sqm.
S & F of Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed . NOTE:- Corrugated shape of sheet shall be approved by GE
S & F of Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed . NOTE:- Corrugated shape of sheet shall be approved by GE
S & F of 6 mm thick asbestos cement corrugated or semi-corrugated sheets fixed with ‘L’ type or ‘J’ type or cranked hook bolts and washers as in roof covering, walls etc. complete all as specified and directed.
Fixing only 6 mm thick asbestos cement corrugated or semi-corrugated sheets fixed with ‘L’ type or ‘J’ type or cranked hook bolts and washers as in roof covering, walls etc. complete all as specified and directed.
S & F of 6 mm thick asbestos cement two piece serrated ridge fo corrugated or semi-corrugated sheets fixed with ‘L’ type or ‘J’ type or cranked hook bolts and washers as in roof covering, walls etc. complete all as specified and directed.
M & L for providing 25 mm thick cement concrete 1:2:4 type B-1 (using 20 mm thick graded stone aggregate) as in floor finishing top surface rough complete all as specified and directed.
M & L Non - skid joint free Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. NOTE: - SCREED SHALL BE MEASURED AND PAID SEPARATELY.
M & L for Glazed ceramic coloured tiles in vertical surface 450x300x 7 mm thick , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. NOTE: - RENDERING SHALL BE MEASURED AND PAID SEPARATELY.
M & L for precast cement concrete tiles tiles of size 250X 250 X 20 mm thick with grey cement and pigment set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile as in roof over APP memberance and laid over 15 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes finished even and rough complete all as specified and directed.
M & L for 15 mm thick rendering on fair faces of brick work or concrete surfaces with cement mortar 1:6 finished even and smooth (without using extra cement)complete all as specified and directed.
M & L for 5 mm thick rendering on fair faces of brick work or concrete surfaces of ceiling with cement mortar 1:4 finished even and smooth (without using extra cement)complete all as specified and directed.
M & L for 15 mm thick rendering on fair faces of brick work or concrete surfaces with cement mortar 1:4 finished even and smooth (without using extra cement)complete all as specified and directed.
M & L for 15 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes finished even and rough complete all as specified and directed.
M & L for 10 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar 1:4 on vertical surfaces of wall finished even and rough suitable for laying wall tiles complete all as specified and directed.
Taking down cement plaster and decayed concrete of any description, upto triple storey of building from roof projection, chajjas etc and making good the decayed portion with cement mortar 1:3 mixed with integral water proofing compound or PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate including necessary form work/scaffolding where ever required, rendering with 15 mm thick cement mortar 1:3, surface finished even and smooth without using extra cement using integral water proofing compound as per manufacturer,s instructions , complete all as specified & directed. NOTE:- Integral water proofing compound shall be measured & paid seprately.
Hacking out old broken glass (any thickness, size, quality or description) from wooden / metal frames, glazed with oil putty or fixed with beads including punching or drilling out old glazing pins / spring clips and providing and fixing new ones complete all as specified and directed.
S & F of 3 mm thick plain, ordinary quality sheet glass and glazing with oil putty or fixed with beads in square not exc. 0.5 sqm in each pane complete all as specified and directed.
M & L for preparation of newly plastered or un-plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M & L for preparing newly plastered or previously untreated wall surfaces and applying two coats of cement base paint over one coat of primer complete all as specified and directed.
M & L for preparing newly plastered or previously untreated wall surfaces and applying two coat of oil bound distemper over a coat of chalk whiting complete all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning and removing all scale and dirt, etc from tanks and from mouths of circulating pipes by using bleaching powder, hoisting if required, reconnecting and re-fixing in position of capacity exc. 500 & n. exc. 1000 ltr, making good for running of water from tank to inside of bldgs and writing of date of cleaning and due on by synthetic enamel paint on water tank, complete all as specified & directed. NOTE :- Cost of bleaching powder shall be deemed included in the quoted rate of this item.
S & F of 500 Litre capacity rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of specifications as per MES Schedule 2009, Part – I and hoisted, fixed in position complete all as specified and directed.
S & F of 1000 Litre capacity rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of specifications as per MES Schedule 2009, Part – I and hoisted, fixed in position complete all as specified and directed.
Taking up or down 15 mm bore steel water tubing and connection, including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 20 mm bore steel water tubing and connection, including cleaning for refixing or removal to store complete all as specified and directed.
Fixing only 15 mm bore old steel water tubing and connection in new or old position to wall and ceiling or laid in floors jointing and testing of old retrieved serviceable galvanized mild steel water tubing with and including all fitting (such as bends, elbows, tees, short pieces, connectors, back nuts, deminishing pieces caps, plugs and union etc) complete all as specified and directed. NOTE: - OLD STEEL WATER TUBING OBTAINED FROM DISMANTLING SHALL BE USED UNDER THIS ITEM.
Fixing only 20 mm bore old steel water tubing and connection in new or old position to wall and ceiling or laid in floors jointing and testing of old retrieved serviceable galvanized mild steel water tubing with and including all fitting (such as bends, elbows, tees, short pieces, connectors, back nuts, deminishing pieces caps, plugs and union etc) complete all as specified and directed. NOTE: - OLD STEEL WATER TUBING OBTAINED FROM DISMANTLING SHALL BE USED UNDER THIS ITEM.
S&F 15mm nominal bore of pipe in walls, and ceiling or laid in floors, jointing and testing galvanised mild steel water tubing “medium grade” with and including all fitting (such as bends, elbows, tees, short pieces connectors, back nuts, diminishing pieces, capas, plugs and union etc) complete all as specified and directed.
S&F 20 mm nominal bore of pipe in walls, and ceiling or laid in floors, jointing and testing galvanised mild steel water tubing “medium grade” with and including all fitting (such as bends, elbows, tees, short pieces connectors, back nuts, diminishing pieces, capas, plugs and union etc) complete all as specified and directed.
S&Fof bib taps, cast copper alloy with crutch or butterfly handle, screwed down, externally threaded having weight @ 0.40 Kg/Each, ISI marked with IS : 781, screwed for iron pipe or brass ferrule of 15mm bore complete all as specified and directed.
S & F of 32 mm bore low density polyethylene pipes (LDPE) of pressure rating 6 Kgf per Sqcm and laid in complete to walls, ceilings or in floors etc. complete all as specified and directed.
S&F fancy type angular stop cock with flange, cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, externally threaded, screwed both ends for iron pipe or for unions of 15mm bore complete all as specified and directed.
S&F stop cock (valves), cast copper alloy, , screwed down, high pressure, with crutch or butterfly handle, externally threaded, having weight @ 0.75 Kg/Each, ISI certification marked with IS : 881, screwed both ends for iron pipe or for unions of 20 mm bore complete all as specified and directed.
S & F of 20 mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) complete all as specified and directed.
S & F in repairs 450 mm long PVC connection with two Nos. PTMT nuts internally threaded and PVC washer suitable for 15 mm bore pipe line complete all as specified and directed.
S & F in repairs water closet vitreous china squatting pan ‘Orrisa’ pattern size 580 X 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe, anti-syphonic pipe etc. with and including setting the trap and pan in lime concrete bedding (one lime, two sand or surkhi and 5 aggregate) minimum 150 mm thick alround and finished just below level of rim of pan to receive the floor finishes complete including making good floor complete all as specified and directed.
S & F in repair vitreous china wash down water closet pan (Pedestal pattern) and trap (excluding) fixing bolts,flushing cistern and flush pipe including connection to drain (or outgoing pipe) including plastic seat cover suitable for water closet pedestal pan, coloured closed pattern with flat bottom and cover and mid steel chromium plated or aluminium hinges devices with and including brass chromium plated standard quality jet with nozzle 1500 mm long PVC pipe etc complete all as specified and directed complete all as specified and directed.
S & F in repair polymer white (polypropylene Delrin and ABS) low level flushing cistern 10 litre capacity valve less, syphonic action type, complete with inlet, ball valve, float valve, bends, brackets, flush pipe, brass screws, handle etc complete having BIS description mark with IS: 7231 with and including 32 mm bore PVC flush pipe of suitable length complete all as specified and directed.
S & F of 110 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint fixed to wall complete all as specified and directed.
S & F of 110 mm bore PVC (SWR) junction single, (Single ‘T’) equal or unequal with Oval access complete all as specified and directed.
S & F of 75 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint laid in trenches or in floors complete all as specified and directed.
S & F of 75 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint fixed to wall/floor complete all as specified and directed.
S & F of 110 mm bore PVC (SWR) bend with Oval access complete all as specified and directed.
S & F of 75 mm bore PVC (SWR) bend with Oval access complete all as specified and directed.
S & F of 110 mm bore PVC (SWR) Slotted vent cowl complete all as specified and directed
S & F of 75 mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed.
Water proofing treatment to sunken portion with 15mm thick rendering in cement mortar 1:3 using integral water prooofing compound both on floor and walls including preparation of surface by making free from all loose particles, surface cured and allowed to dry, apply a coat of Moisture Cured High Tensile Elastomeric Modified Poly Urethane based liquid membrance coating as per manufacturers instructions both on floor as well on walls, sunken slab shall be laid to a slope of 1:40 outwards with 25mm dia PVC pipe spout projecting at least 45mm beyond out face of wall, complete all as specified & directed. Notes : a) PVC spout 25mm dia, PCC 1:4:8 type D2 and WC / EWC shall be measured and paid for separately under respective items. b) Ponding shall be done in sunken portion area by filling water which shall be kept there for one week. In case a slightest indication of seepage /leakage is noticed, the same shall be rectifird by grounting the effected area at no extra cost. Thereafter, ponding shall be repeated till there is no indication of seepage/leakage. The arrangements of ponding to be included in quoted rates and nothing shall be admissible on this account.
Complete removal of the existing roof treatment of any description viz tarfelt or membrance surface of roof tiles/concrete padding etc including grubbing up of tree roots, removing all the debris to a distance n exc 100m for roof treatment work, preparation of the concrete roof surfaces by scrubbing down with steel brushes and cleaning with water all loose dirt/dust and applying the following Roof Treatment complete all as specified & directed :- (a) Applying 1st course of 15mm thick screed bed in cement mortar 1:4 over concrete surfaces. (b) Applying 2nd course of bitumenous primer conforming to IS-3384 @ 0.4 Kg/Sqm over the screed bed. (c) Applying 3rd coarse of a coat of blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm. (d) Applying 4th course of APP (Atactic Polypropylene) modified polymeric membrane 3 mm thick weight not less than 3.6 Kg/Sqm with 160 Grams/Sqm non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to be laid with LPG torch and overlap sealed and finished neat. (e) Applying 5th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm. (f) Applying a coat of bitumious based aluminium
Supply only water proofing compound (Liquid) complete all as specified.
M/S CHOUDHARY BUILDERS
M/s Anand Prakash
NARESH KUMAR AND COMPANY
M/S RAVINDER SINGH
GENESIS INDIA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .