Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 LAccepted-AOC | ₹4.4 L | L1 | Accepted-AOC Work was Awarded |
| 2 | L2₹4.5 LRejected-AOC D NO 17 143 APOLLO GARDEN MADANADAR KUDIERUPPU NEAR KUMARAPURAM JN TIRUNELVELI 627 133 | TIRUNELVELI | TAMIL NADU | 627133 | ₹4.5 L | L2 | Rejected-AOC Work was Not Awarded |
| 3 | L3₹5.7 LRejected-AOC 40 E SUNDARAVELPURAM 7TH STREET TUTICORIN 628 002 | TUTICORIN | TAMIL NADU | 628002 | ₹5.7 L | L3 | Rejected-AOC Work was Not Awarded |
| Sl No | Description | Qty | Unit | S. MURUGAN CONTRACTOR L3 | APOLLO TRANSFORMERS AND FILTERS L2 | APOLLO ELECTRICAL SERVICE L1 |
|---|---|---|---|---|---|---|
| 1.00 | Maintenance of L.T. Boiler auxiliary motor De-termination of power cable, removal of L.T. Boiler auxiliary motor from the bed, measurement of IR values and winding resistance values of the motor, field coil and tacho-coil in the RC feeder motor and fault rectification by dismantling the motor and replacing the failed and worn out parts, reassembling and re fixing the motor on the bed, checking complete alignment, reconnecting the power cable and conducting trial run satisfactorily.(Including Cost of consumables, and hire charges for T&P) | 24 | Nos | 1,31,712 ₹1.6 L | 1,04,400 ₹1.2 L | 1,03,200 ₹1.2 L |
| 2.00 | Maintenance of L.T. Boiler valve motor / Soot blower motor Determination of power cable, removal of valve motor from the actuator, measurement of IR values and winding resistance values in the motor, and fault rectification by dismantling the motor and replacing the failed and worn out parts, reassembling and re fixing the motor on the actuator, reconnecting the power cable and conducting trial run satisfactorily. (Including Cost of consumables, and hire charges for T&P) Valve Motor - 12 Nos. Soot blower motor-24 Nos. Total - 36 Nos. | 72 | Nos | 1,88,784 ₹2.2 L | 1,51,200 ₹1.8 L | 1,44,000 ₹1.7 L |
| 3.00 | Rectification of LT Module Inspection of module during fault and rectification of the fault by tracing the control circuit, checking of tightness, replacing failed parts, complete checking the healthiness of module and out going cable in the BMCC, BVMCC, and soot blower modules. | 72 | Nos | 1,87,416 ₹2.2 L | 1,51,200 ₹1.8 L | 1,44,000 ₹1.7 L |
| 4.00 | Maintenance of Ash Silo Transformer Removal of Terminal box cover, measurement of IR values, checking tightness, inspection of cables, breather, explosion vent, oil level and collecting of oil sample for BDV test and complete cleaning of Ash silo Transformer A & B. (Including Cost of consumables, and hire charges for T&P) | 8 | Nos | 57,880 ₹68,298.40 | 46,400 ₹54,752 | 46,240 ₹54,563.20 |
Tender Value
Refer Docs
EMD Value
₹5,000
Closing Date
2 Jan 2026, 2:00 pmClosed
CE/TTPS
Chief Engineer Tuticorin Thermal Power Station-Tuticorin
TTPS ES Circle EM III Fault attending in boiler auxiliary motors and modules valve motors soot blower motor and preventive maintenance of Ash silo transformer A and B of unit IV V for the period from 01 04 2026 to 31 03 2027
2025_EB_633480_1
CE/SE/ES/TTPS/51/2026-27
Open Tender
Electrical and Maintenance Works
365 days
TTPS
As per BQR conditions in NIT
7 documents required · 7 mandatory
₹0
₹5,000
Yes
23 Mar 2026
17 Dec 2025
3 Jan 2026
17 Dec 2025
2 Jan 2026
17 Dec 2025
Maintenance of L.T. Boiler auxiliary motor De-termination of power cable, removal of L.T. Boiler auxiliary motor from the bed, measurement of IR values and winding resistance values of the motor, field coil and tacho-coil in the RC feeder motor and fault rectification by dismantling the motor and replacing the failed and worn out parts, reassembling and re fixing the motor on the bed, checking complete alignment, reconnecting the power cable and conducting trial run satisfactorily.(Including Cost of consumables, and hire charges for T&P)
Maintenance of L.T. Boiler valve motor / Soot blower motor Determination of power cable, removal of valve motor from the actuator, measurement of IR values and winding resistance values in the motor, and fault rectification by dismantling the motor and replacing the failed and worn out parts, reassembling and re fixing the motor on the actuator, reconnecting the power cable and conducting trial run satisfactorily. (Including Cost of consumables, and hire charges for T&P) Valve Motor - 12 Nos. Soot blower motor-24 Nos. Total - 36 Nos.
Rectification of LT Module Inspection of module during fault and rectification of the fault by tracing the control circuit, checking of tightness, replacing failed parts, complete checking the healthiness of module and out going cable in the BMCC, BVMCC, and soot blower modules.
Maintenance of Ash Silo Transformer Removal of Terminal box cover, measurement of IR values, checking tightness, inspection of cables, breather, explosion vent, oil level and collecting of oil sample for BDV test and complete cleaning of Ash silo Transformer A & B. (Including Cost of consumables, and hire charges for T&P)
APOLLO TRANSFORMERS AND FILTERS (BID ID -1551667)
S. MURUGAN CONTRACTOR (BID ID -1550019)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
BOQ_757900.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid