Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹46.2 L+₹18,019 (0.39%)Rejected-Finance D 662 WZ 1598 R 1 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹46.4 L+₹42,464 (0.92%)Rejected-Finance FLAT NO 744 RAMA APARTMENTS PLOT NO 2 SECTOR 11 DWARKA NEW DELHI 110075 | SOUTH WEST | DELHI | 110075 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹50.2 L+₹4.2 L (9.03%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
12 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE NO 2
CWE NO 2 DELHI CANTT
SPL REPAIR TO BLDG NO T-45, T-60, P-93 AND P-94 AT 262 TRANSIT CAMP UNDER GE (WEST), DELHI CANTT-10
2020_MES_358197_1
CWE/WEST-08/2020-21
Open Tender
Civil Works
Item Rate
180 days
DELHI CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (WEST) DELHI CANTT
₹98,000
Yes
19 Sept 2020
3 Jul 2020
14 Aug 2020
3 Jul 2020
12 Aug 2020
31 Jul 2020
60 days
Amount
Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
Dismantling timber scantling 40 Sqcm and over in section in any position as in unframed work, complete all as specified and directed.
Taking down Chowkats or frames n.exc 1.5 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down Chowkats or frames exc 1.5 sqm but n.exc 4 sqm each with shutters (without taking off shutters from the frames) complete all as specified and dircted.
Dismantling of wall and ceiling boards (fibre, pulp, insulation. etc) or insulation boards/slabs/blankets, any thickness, including cover fillets complte all as specified and directed.
Taking down cement plaster from stone/brick walls including racking out joints for keys and scrubbing down with water and removing the rubbish from the premises and disposed off outside MOD land etc, complete all as specified and directed.
S&F false ceiling of grid of galvanzed steel tee/ angle (power coated ) of grid size 600x600mm as directed comprising of main tee ( weight not less than240gm /RM) and angle (weight of section not less than 217gm/RM) all around of walls suspended of ceiling by fasteners of adjustable guide hanger including clips/MS fitments to hold the panels insert of any type, including ceiiling boards of size 595x595x16mm thick mineral fibre board designer tiles of approved firm fixed in position complete all as specified and directed.
S&F mild steel rolled work as in roof trusses, (framed), trussed, purlin, crane gantries, rails and heavy bracket framing (Beam, angle, channel or flat section) including distance pieces,cleats etc,confirming to grade Fe 410 -o or Fe 310-o, complete all as specified and directed.
S&F Rolled mild steel section as in main and cross beams ,hip and jack rafters ,purlins,wind ties for roof sheet, where connected to common rafter and running rails and guides for sliding doors ,fixed with angle cleats or other connecting plates confirming tograde Fe-410-o or Fe-310-o, complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge,roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for 15mm thick cement plaster in Cement Mortar 1:6 on bricks or concrete surfaces finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick cement plaster in Cement Mortar 1:4 on bricks or concrete surfaces with water proofing compound finishing the surfaces even and smooth without using extra cement complete all as specified and directed. Note: WPC shall be measured and paid separately as supply only.
Supply only liquid integral water proofing compound complete all as specified and directed. Make: Dr. Fixit LW+ or equivalent in Pidilite/
M&L for preparation of newly plastered surfaces of walls and applying birla white putty 1 to 2 mm on wall even and smooth surface and applying two coat of oil bound distemper over a coat of alkali primer (of approved quality and tint) on wall using painting roller, complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and applying two coat of oil bound distemper over a coat of alkali primer (of approved quality and tint) on ceiling using painting roller, complete all as specified and directed.
M&L for complete removal of old existing treatment by brooming down or steel wire brushing, scrapping down smoke, mass, efflorescent salt and oil and greesy spot etc by electric driven sanders machine and washing rubbing down distemper surfaces and applying birla white putty 1 to 2 mm thick on wall even and smooth surface and applying two coat of oil bound distemper over a coat of primer (of approved quality and tint) on wall using painting roller, complete all as specified and directed.
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
M&L for factory made 2nd class hard wood(Kail) 35mm thick glazed /gauzed and skelton shutters, open rebated and prepared to receive glass, gauge etc (with sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc, sizes of members of shutters specified in SSR Part I, Section 8 , Clause 8.24(a).complete all as specified and directed.
S&F factory made 35mm thick flush shutters solid core construction with plywood core and plywood face panels commercial type covered with decorative face veneer with lipping/frame to match complete all as spcified and directed.
M&L for two coats of synthetic enamel paint over a coat of pink primer on new wooden surfaces over 10 cm in width or girth including preparation of new or previously untreated surfaces of wood complete all as specified and directed.
M&L for two coat of synthetic enamel painting on new steel surfaces over 10cms width or girth over a coat of red oxide primer including preparation of newly or previously untreated surfaces of steel complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings dressed stone work and Precast concrete articles, complete all as specified and directed.
M&L for Brick work with Sub class 'B' bricks straight or curved on plan exceeding 6m mean radius, built in Cement mortar 1:6 complete all as specified and directed.
S&F in stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples (for steel windows and gauzed doors) all as specified and directed
M&L PCC 1:2:4 type B1 (20mm graded aggregate) as in anchoring hold fast, bed plate etc complete all as specified and directed.
S&F 100mm long PVC butt hinges for PVC doors complete all as specified and directed.
S&F 125mm long PVC handle for PVC doors complete all as specified and directed.
S&F 200mm long PVC tower bolt for PVC doors complete all as specified and directed.
S & F stainless steel butt hinges 100mm long medium weight etc complete all as specified and directed.
S & F 200mm long aluminum, anodized barrel tower bolts of extruded section complete all as specified & directed.
S&F 250mm long aluminium alloy,anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
S & F aluminum anodised handle 150 mm long cast type complete all as specified and directed.
S&F floor door stopper 150mm of brass body and tongue, with hard drawn steel spring, fixed in floor complete all as specified and directed.
S&F solid PVC Door Frame of size 50mm x 95mm made out of 5mm wood grain printed PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
S&F factory made solid PVC moulded door shutter 28 to 30mm thick(stiles) with 2,4 or 6 raised panel design with 2mm thick 3D wood grain moulded PVC sheet polyurethane painted on the front face & 2mm plain colour PVC sheet on back face complete all as specified and directed.
S&F in repair vitretious china wash down water closet pan (padestal pattern (excluding flushing cistern but including flush pipe and pvc sheet cover white) complete all as specified and directed.
S&F in repair vitreous china wash hand basin, white flat back, size 580 x 450mm excluding taps, waste pipe chain and plug and porcelain but including brackets, waste coupling complete all as specified and directed.
S&F in repair flushing cistern 10ltr capacity syphonic action type low clevel with inlet ball valve ,float valve and handle including bracket,flushing pipe etc. complete all as specified and directed.
S&F in repair PVC connetion of size 15x600mm with PTMT nuts complete all as specified and directed.
M&L in repair for cast iron floor trap of 75mm dia,plain with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
S&F in repair Cast iron vent cowl of 100mm dia complete all as specified and directed.
S&F in repair 100mm bore cast iron "P" or "S" trap,bends,tee,branch pieces with oval acess door complete all as specified and directed.
S&F in repair for 15mm dia 2 in 1 bib taps, cast copper alloy chromium plated with capstan head fancy type,screwed down,screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair for wash basin mixer CP/brass with capstan heads, screwed down high pressure, screwed for iron pipe and fixed complete all as specified and directed.
S&F in repair for wall mixer 3 in 1 CP/brass with capstan heads, screwed down high pressure, screwed for iron pipe and fixed complete all as specified and directed.
S&F in repairs 15 mm bore angle valve, cast copper alloy screwed down high pressure with capstain head with long shank & cup complete all as specified and directed.
S&F in repair chromium plated brass overhead shower rose 150x150mm, with revolving joint fixed to 15mm pipe, complete all as specified and directed.
M & L in repair for chromium plated toilet paper holder complete all as specified and directed.
S&F in repair 20mm dia brass chromium plated towel rail 600mm long between flange complete all as specified and directed. Make: Jaquar cat No. ACN-1111SM or equivalent in GEM/ Marc/ Jalangi
M & L in repair hand shower (health faucet) (ABS chromium plated ) with 8mm dia, 1m long flexible tube and wall hook complete all as specified and directed.
M & L in repair chromium plated bottle trap (with internal partition ) 32mm size with 250mm and 190mm long wall connection pipes & wall flange complete all as specified and directed.
M & L in repair chromium plated jet spray including connection pipe comlete all as specified and directed.
M & L in repair chromium plated soap dish complete all as specified and directed.
S & F in repair 15 mm dia two way angle valve cast copper alloy chromium plated with capstan head handle, screwed down high pressure screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repair chromium plated towel rack 600mm long with lower hanger complete all as specified and directed. Make: Jaquar Cat Pat No. ACN-1181N or equivalent in GEM/ Marc/ Jalangi
S&F in repair chromium plated towel ring square with round flange complete all as specified and directed. Make: Jaquar Cat Pat No. ACN-1121N or equivalent in GEM/ Marc/ Jalangi
S&F CPVC pipe 20mm external dia with all fittings and fixed complete to walls ceilings or laid in floors of medium grade including dismantling old GI pipes complete all as specified and directed.
S&F CPVC 25mm external dia with all fittings and fixed complete to walls ceilings or laid in floors of medium grade including dismantling old GI pipes complete all as specified and directed.
S&F of 1000 ltr capacity rotational moulded polythene water tank hoisted & fixed in position including PVCfloat valve 20mm dia including dismantling old water tank complete all as specified and directed.
M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (square) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm (size 400x400mm), in floors etc set and joined in neat cement slurry and pointed in white or colour cement to match colour tiles including 15 mm thick screed bed in Cement Mortar 1:6 including dismantling of old tiles and removing the rubbish from the premises and disposed off outside of MOD land complete all as specified and directed.
M&L for glazed ceramic coloured tiles (300x600x7mm/ 450x350x7mm ) thick on vertical surfaces such as skirting and dado set and joint in neat cement slurry and pointed in white or coloured cement to match including 10mm thick plastering in Cement Mortar 1:4 rough to receive tiles including dismantling of old tiles and removing the rubbish from the premises and disposed off outside of MOD land complete all as specified and directed.
Demolition of cement concrete in ground floor and paving n.exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for Plinth protection 75 mm thick in PCC 1:3:6 type C-1(using 20 mm graded crushed stone aggregate) laid in alternate bays(not exc 2 Sqm each) finished even and fair at top without using extra cement and providing joints throughout the thickness of plinth protection, filled with mastic filling comprising one part of bitumen 85/25 graded and three parts of sand by weight complete all as specified and directed.
S&F 100mm dia cast iron (spun cast) soil, waste and vent pipe in any length with or without ears with lead joints laid in trenches,wall or in floor including all fittings including demolition old CI pipes, complete all as specified and directed.
S&F 75mm dia cast iron (spun cast) soil, waste and vent pipe in any length with or without ears with lead joints laid in trenches, wall or in floor including all fittings including demolition old CI pipes, complete all as specified and directed.
M&L for vetrified ceramic light shade tiles 10mm thick (Square) polished, area of each tile n exc 0.36 Sqm (size 600x600mm), in floor etc, set & jointed in neat cement slurry and pointed in white or coloured cement to match including dismantling of old tiles and removing the rubbish from the premises and disposed off outside of MOD land complete all as specified and directed.
M&L for screed bed or bedding layer of cement mortar 20mm thick for laying floor finish of cement plaster 1:6 complete all as specified and directed.
M&L for rendering 15mm thick in Cement Mortar 1:4 as in backing coat on brick work or concrete surfaces complete all as specified.
M&L for preparation of newly plastered surfaces of walls and applying two coats of exterior acrylic emulsion paint over a coat of alkali resistant primer including 1 to 2 mm thick exterior wall care putty complete all as specified and directed.
M&L for complete removal of old existing treatment, preparation of surfaces of walls and applying two coats of exterior acrylic emulsion paint over a coat of alkali resistant primer including 1 to 2 mm thick exterior wall care putty complete all as specified and directed.
S&F in repair stainless steel drapery rod (curtain rod) 28 - 32 mm dia,pair of suitable brackets,fennals and also making good the wall surface to match the existing surfaces complete all as specified and directed.
M&L for providing cement concrete 1:2:4 type B-I (20mm graded agg) in roof kerb or mud slops, rounded or chamfered on edges, coping, kneelers, kerb water tough and the like including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed.
M&L for water proofing treatment to roof surface with APP polymeric based water proofing membrane 3mm thick & weighing not less than 3.5 Kg/Sqm of approved make black finish consisting of a central core of high molecular high density polyethylene film (HMHDPF) & reinforced with non woven polyester matt of min 90 gm/sqm with a thermo fusible finish laid over a coat of hot blown bitumen of 85/25 grade conforming to IS 702 @ 1.2 kg/sqm over a coat of an bitumen primer conforming to IS-3384 @0.4 Ltr/Sqm over prepared roof surfaces, forcing overlap with a propane or butane gas torch with a overlap of 75mm at sides & 100mm at ends & sealing including applying a coat of cold emulsion bituminous primer complete as per manufacturer's instructions complete all as specified and directed. Note :- 1. Water proofing treatment shall be got carried out by the manufacturer or their authorised applicator only. 2. Bitumen primer, bitumen and membrane shall be of same make / manufacturer. 3. The APP Membrane to be inserted in the parapet wall/wall by cutting chases of at least 65mm X 50mm size & making good in Cement Mortar 1:3. Make: Ms Sika India Pvt Ltd/ Ms Fosroc Chemicals/ Ms STP limited/ Ms IWL India limited/ Ms Tiki Tar Danosa (India) Pvt Ltd/ Ms Torchtar Membrane & Bitumen Pvt Ltd
M&L for cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) on roof padding with water proofing compound surface finished even and smooth without using extra cement complete all as specified and directed. Note: WPC shall be measured and paid separately as Supply only
M&L for cement concrete plain tiles 25cmx25cmx22mm thick machine pressed set jointed and pointed in neat cement slurry with grey cement and no pigment in floors with screed bed in 15mm thick Cement Mortar 1:6 complete all as specified and directed.
Supply and fixing for aluminium powder coated sliding window made of the following specifications :- Note : external size of window shall be measured. Following items are included in this unit rate. (a) Aluminium frame powder coated all around of hollow section 100 mm x 44 mm x 1.60 mm thick. (b) Provn of 03 trade runners of size 92 x 31.75 x 1.10 mm. (c) Provn of glazed sliding shutters (02 Nos) of section 44 mm x 18 mm x 1.25 mm provided with 4 mm thick heat obseving glass with suitable EPDM beading and locking clips arrangement. (d) Provn of 01 No gauzed shutter of Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm with suitable EPDM beading arrangement of Section 44 mm x 18 mm x 1.25 mm . (e) Aluminium powder coated grill of weight not less than 1.60 Kg/Sqm on external side with suitable frame/aluminium runner to be fixed on the window frame. Note :- Opening for windod type AC shall be made in Alumunium window in Each room and rates if required shall deemed to be included in this item.
S & F aluminium powder coated ventilators made of complete all asspecified and directed for the following specifications :- Note: Net external size of ventilator shall be measured. Following items are included in this unit rate. (a) Aluminium frame powder coated styles, bottom, top and middle rail of hollow section 50 mm x 25 mm x 1.80 mm thick. (b) Lower portion of ventilator shall be fixed with 3 mm thick pin headed glass fixed with suitable aluminium beading clips and EPDM beading (rubber). (c) Upper portion shall be fixed with aluminium powder coated louver guides fixed with 3 mm thick pinheaded glass with suitable EPDM beading incl suitable handle and clips. (d) Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with suitable frame in upper panel.
M&L for 50mm dia high density polyethylene pipes (HDPE) of pressure rating 6kgf/cm2 fixed complete to walls,ceiling or laid in floors etc including taking down old PVC pipe complete all as specified and diretced.
Demolition of stone slab and tiles of any description or thickness in floors laid bedded and pointed in any mortar and removing the rubbish from the premises and disposed off outside of MOD land complete all as specified and directed.
M&L for machine cut kota stone slab flooring 20-25mm thick laid over 20mm thick screed bed in cement mortar 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and directed.
M&L for machine cut kota stone slab flooring 20-25mm thick as in riser in steps,skirting ,dado and pillar laid over 15mm thick backing coat in cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and directed.
M&L for grinding and polishing of old kota stone flooring complete all as specified and directed.
S & F in repair mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors, angle iron chowkhats; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0, complete all as specified and directed.
S&F brass connetion of size 15x600mm with brass nuts for geyser complete all as specified and directed.
S&F factory made RCC GT cover of size 500x400x50mm thick with 01 no handle and 150mm dia notch at one side of cover at centre at 500mm long side complete all as specified and directed.
S&F for aluminium peg set of six fixed on aluminium flat of size 25mm wide 450mm long and 3-4mm thick fixed on wall with wooden guity CP brass screws complete all as specified and directed.
S&F for aluminium door seal complete all as specified and directed.
S&F for door eye complete all as specified and directed.
M&L for cutting holes in brick walls built in cement mortar or cement lime mortar for inserting hold fasts depth of embeded portion of hold fast exc half brick but n.exc one brick and making good dismantled portion in Cement mortar 1:3 or cement concrete 1:2:4 type B-1 and removing the rubbish from the premises and disposed off outside of MOD land as required complete all as specified and directed.
S&F in repair 15mm gun metal globe or gate valves with iron wheel head,screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair 20mm gun metal globe or gate valves with iron wheel head,screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair 100mm dia stainless steel grating with or without hole fixed with solvent cement in floor/nahani trap complete all as specified and directed.
M&L 18-20mm thick black granite of size in single pieces with full width of wall (tabled rubbed, polished and moulded) as in columns, steps, window cills and like laid over 15mm screed bed or plastering in Cement Mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with the shade of granite including dismantling of stone slab complete all as specified and directed by the Engr-in-Charge.
M&L for repairing of spalled concrete from ceiling in the following stages:- 1. Prepration of existing surfaces like chipping of unsound weak / loose concrete with electric hammer or manually including tapering all edges, making square shoulders of cavities etc. n.exc 50 mm thickness removal of debries, complete all specified and directed by the Engineer-in-charge. 2. Applying rust remover cum passivator Sika rustoff 100 @ 0.20kg/Sqm/per coat or as per manufacturer's specifications to remove rust from existing reinforcement. 3. Applying a epoxy based zinc rich rebar corrosion protection system of product : Fiazin (R) R @ 0.15Kg/Sqm/coat or as per manufacturer's specifications. 4. Mixing & applying two component Epoxy resin concrete Bonding coat of Sikadur(R)-32 LP A & B @ 0.40 Kg/Sqm(Mixing proportion as per manufacturer's instructions) on prepared RCC surfaces as per manufacture specification including prepartaion of surface by chipping and throughly cleaning of surface complete whereever required over new reinforcement (if required) and as directed by the Engineer-in-charge.(Reinforcement will be measured and paid separatley). 5. Apply a pre-batched one component polymer modified cementious patch repair mortar n.exc 50mm in layer of 15mm thick each of Product: Sika Mono Top®-122 F as per manufacturer insturctions and as directed by the Engr-in-Charge. 6. Apply aluminised synthetic resin Concrete curing compounds for the prevention of premature water loss from concrete of product: Antisol®-E(WP) @ 0.10 to 0.20 kg/m2 as manufacturers instructions and as directed by the Engr-in-Charge. Make: Sika or equivalent in Fosroc/ STP limited
M&L PCC 1:5:10 Type C2 (using 40 mm graded stone aggregate) in mass concrete including demolition of unreinforced cement concrete exc 15cm thickness for sunken portion of WC, complete all as specified and directed.
Taking down cement plaster of any description and M & L for rendering 10 mm thick in cement mortar 1:4 laid to achieve slope with two coat of teap create mixed (1:2) with cement slurry @ 500 gm per sqm as per manufacturer instruction in sunken portion of toilets ,finished even and smooth without extra cement and applying a coat of hot blown bitumen primer as the rate of 0.70 kg per sqm and applying one coat of hot bitumen 85/25 grade at the rate of 1.20 kg per sqm and one layer of 2mm thick APP membrane,a coat of hot blown bitumen 85/25 grade at the rate of 1.20 kg per sqm over it including getting out etc all as specified and directed.
M&L for old painted steel and iron surfaces of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
S&F 18/19mm thick prelaminated particle board/plywood grade BWP type BB ,interior grade,prelaminated one side for cupboard shutter/partition with knob, hinges and handle each cupboard with decorative choice lamination & other side balancing white lamination,fixed with screw to timber frame work complete all as specified and directed.
Impregnating cream for injection into masonry or concrete wall 230mm thick against capilary rising humidity. Rising bars super strong product No.201 of chowgale building chemicals are equivalent Pidilite/Dr. Fixit/Sika/Fosroc complete all as speified and directed. Method of application Methodology (a) The surface must be sound, absorbent,clean, free of dust, oil,paint, curing agents, loose cement or lime plaster & concrete debris or any sepration layers. (b) The plaster must be knocked off at least 50cm beyond the visiblity penetrated area. (c) Damaged mortar joints are to be scraped out to a depth of approximately 2-3 cm.All sharp edges/joints need to be levelled loose concrete to be removed. (d)Drill boreholes at ground level horizontally.The boreholes are drilled horizontal into the masonry. (e) The holes should be drilled until a depth of approx 5cm(for a 6cm thick wall) before the end of the wall is reached.The boreholes should have a diameter of 12mm upto a maximum of 15mm and should be spaced approx 100 to 120mm apart and the vertical offset is 6cm max. (f) Before inserting rising bar super strong or equivalent the boreholes must be cleaned from boring dust by using air pressure it is not necessary to pre-wet the borehole. (g)For applying of rising bar super strong or equivalent the dosing system inserted as far as possible into the bore hole.While dosing the product uniformly,the injection nozzle out leading to a completely filled bore hole. (h)Treatment of highly absorbent masonry might require repeated filling of the boreholes depending upon extent of damage rising bar super strong or equivalent can be reinjecting into the same hole after 24 hrs.Depending on absorbence application or masonry thickness 0.1 to 0.15 ltr/m with 10cm wall thickness.
M&L for anti termite treatment along the external wall below concrete or masonry apron using chemical emulsion @2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed.
M&L for anti termite treatment of soil under existing floor using emulsion @ 1 Litre per hole 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement :2 coarse sand) to match the existing floor complete all as specified and directed.
Taking down carefully copper/aluminium any type of point wiring (light/fan/socket/power) complete (fittings such as switches, ceiling roses, holders, sockets, light fittings) and deposit the same to MES Store and making good the disturbed surfaces of wall/floors/ceiling etc) complete all as specified and directed.
M&L for concealed point wiring with PVC FRLS insulated multi stranded unsheathed cable 1.5 sqmm size with stranded copper conductor, 1100 volts grade conforming to IS-: 694 drawn in and including concealed PVC rigid conduits 20 mm dia including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed with concealed sunk in pressed steel terminal boxes of 1.6mm thick factory made and painted with stove enameled black paint covered with 3mm thick plastic laminated sheet of required colour fixed with brass screws and cup washers including single core stranded copper conductor 1.5 sqmm PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same concealed conduit complete all as specified and directed for the following :-
One light/fan/bell point controlled by one way switch 5 amps.
One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one way switch on same board.
All as per item No. 105 above but with 2x2.5 Sqmm and 1x 1.5 sqmm cable for earth connection for one 3 pin socket outlet 15 amps independent board complete all as specified and directed
S&F in repair switch piano flush button type 5 amps single pole one way complete all as specified and directed.
S&F in repair switch piano flush button type 15 amps single pole one way complete all as specified and directed.
S&F in repair socket outlet multipurpose 2/3 pin 5 amps flush button type complete all as specified and directed.
S&F in repair socket outlet multipurpose 2 in 1, 5 and 15 Amps complete all as specified and directed.
S&F in repair bell push flush type 5 amps complete all as specified and directed.
S&F in repair electric bell Ding-Dong AC 230 Volt SP with brass screws and cup washers complete all as specified and directed.
S & F in repair of decorative wall light fixture city-3 made up of polycarbonate, suitable for 15 watt LED bulb complete all as specified and directed. Make: Havelss Cat part no- LHDL06160099 or equivalent in Philips/ Baja/ Crompton Greaves/ Benlo/ C&S Electric/ Polycab/ Halonix
Supply, laying and drawing in and including 20 mm dia concealed PVC rigid conduits including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed on walls 02 runs of IC x 4 sqmm (Main Cable and neutral) and one run of IC x 2.5 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including taking down complete all as specified and directed.
Supply, laying and drawing in and including 20 mm dia concealed PVC rigid conduits including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 4.0 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including taking down complete all as specified and directed.
Taking down ceiling fan , sealing cable end, dismantling blades and removing fan and blades to MES store complete all as specified and directed.
S&F of celing fan 1200 mm sweep including blade canopy, down rod, regulator and connecting up including provision of flexible PVC FRLS cable with stranded copper conductor of size 0.75 sqmm from ceiling rose to connector of ceiling fan complete all as specified and directed.
S&F in repair of factory made epoxy polyester powder coated distribution board SP & N 8 way fabricated from minimum 1.6 mm thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, eath bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 6 SP MCBs as outgoings and conforming to IS: 8623 alongwith cable end box for above DB complete all as specified and directed. NOTE (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F in repair of single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 including taking down old MCB's complete all as specified and directed.
S&F in repair of double pole MCB 40 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for 10 KA breaking capacity complete conforming complete all as specified and directed.
S&F in repair of surface mounting 20 watt LED tube light fitting of 4 ft length connected with 23/.0076 twin core PVC flexible cable complete all as specified and directed. Make: Havells Cat Part No: LUMILINEPLLUSBS20WLED865SPCSS or equivalent in Philips/ Baja/ Crompton Greaves/ Benlo/ C&S Electric/ Polycab/ Halonix
S&F new generation energy saving and environmental friendly long life versatile pressure die cast alumonium IP-66 road way luminaire with high power 25 watt LED security light complete all as specified and directed. Make: Havells Cat Part No: ENDURAPEARLSL25WLED757SASYTOPC 2 or equivalent in Philips/ Baja/ Crompton Greaves/ Benlo/ C&S Electric/ Polycab/ Halonix
S&F in repair of factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN MCCB DB) with metal double door (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for DPX 160, 4 pole MCCB and ELM as incommer and Single Pole MCBs outgoings and conforming to IS: 8623 along with cable end box for above DB including taking down old DBs complete all as specified and directed. NOTE :- (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F in repair of MCCB 125 Amp 4 pole 16 KA at 415 V with fixed thermal megnatic release complete all as specified directed.
M&L for Earthing complete with galvanised steel earth plate electrode 600×600× 6mm thick, buried directly into the ground (earth pit not lessthan 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point and PCC CI cover.funnel with watering pipe wiremese,and copper lugs etc,GI protection pipe of size,test point extra length of main earthing lead 7.5 mtrs ,connectiong lead from last point to main switch or switch board.or equipment to be earthed on testing after complete the earth resistance and earth will be done at no extra testing on completion complete all as specified and directed.
S&F of electric storage water heater of capacity 25 ltr with vitreous enamel coating with all accessories and fittings arrangements and testing after installation complete all as specified and directed. Make: Havells Model- Monza EC or equivalent in Crompton Greaves/ Bajaj/ Morphy Richards/ Venus/ Lexus/ Jaguar/ Orison Note: Rates are inclusive of connection from existing pipe line to electric storage water heater.
S&F in repair single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed.
Supply and fixing metal type exhaust fan single phase, 230/240 V of 300 mm sweep including cutting of holes in a round shape,fixing rag bolts,plastering and fixing the fan complete all as specified.
Dismantling of brick tiles or terracing tiles single layer on roof complete all as specified and directed.
Demolition of mud phaska on roof slabs any thickness including cleaning of roof surface and removing the debris from the premises and disposed off outside the MOD land complete all as specified and directed.
SHIVA ENTERPRISES
Chandramauli Engineers Pvt. Ltd.
Kunal Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .