Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹76.3 LAccepted-AOC 184 C 13 THURAIYUR SAMINATHAN NAGAR PERAMBALUR SALAI TIRUCHIRAPPALLI TAMIL NADU 621010 UDYAM TN 27 0052941 | TIRUCHIRAPPALLI | TAMIL NADU | 621010 | L1 | Accepted-AOC BEING LOWEST TENDER, L1 | |
| 2 | L2₹79.8 L+₹2.2 L (2.83%)Rejected-Finance 47A C3 OLD DAMU NAGAR PULIAKULAM COIMBATORE 641 045 | COIMBATORE | COIMBATORE | TAMIL NADU | 641045 | L2 | Rejected-Finance BEING NOT LOWEST TENDER. | |
| 3 | L3₹80.9 L+₹3.3 L (4.23%)Rejected-Finance THE JEHOVAH SHALOM 21 THIRUMALAISAMY STREET LAKSHMI NAGAR EXTN KAVUNDAMPALAYAM COIMBATORE 641030 | COIMBATORE | COIMBATORE | TAMIL NADU | 641030 | L3 | Rejected-Finance BEING NOT LOWEST TENDER. | |
| 4 | L4₹81.3 L+₹3.7 L (4.76%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST TENDER. | |
| 5 | L5₹82.3 L+₹4.7 L (6.11%)Rejected-Finance | L5 | Rejected-Finance BEING NOT LOWEST TENDER. |
| Sl No | Description | Qty | Unit | KRISHNA ENTERPRISES L2 | KUMAR AGENCIES L3 | p.chinnasamy L4 | A.GOVINDARAJ L5 | KSR AND COMPANY L6 | eurekaenterprises L7 | NLK Construction L1 | Neptune Engineers and Builders L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00SCHEDULE A BOQ | |||||||||||
| 2.00 | M&L for demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) | 69.75 | Cum | 1,542 ₹1,07,554.5 | 1,200 ₹83,700 | 1,050 ₹73,237.5 | 1,105 ₹77,073.75 | 236 ₹16,461 | 65 ₹4,533.75 Lowest | 130 ₹9,067.5 | 1,240 ₹86,490 |
| 3.00 | M&L 100 mm thick Plain cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate ) as in sub base , fillng and mass concrete or as in receiving tiles/ surface channels and drains etc complete all as specified and directed. | 168 | Sqm | 435 ₹73,080 Lowest | 550 ₹92,400 | 512 ₹86,016 | 605 ₹1,01,640 | 550 ₹92,400 | 523 ₹87,864 | 440 ₹73,920 | 512 ₹86,016 |
| 4.00 | M&L Chequered cement concrete tiles 30cmx30cmx25mm thick machine pressed set jointed and pointed in neat cement slurry as in floors and cut and polished using grey cement and pigments over screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:4) including demolishing the existing tile complete all as specified and directed
Note : The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation/fixing. | 168 | Sqm | 1,623 ₹2,72,664 | 1,500 ₹2,52,000 Lowest | 1,598 ₹2,68,464 | 1,984 ₹3,33,312 | 1,700 ₹2,85,600 | 1,697 ₹2,85,096 | 1,550 ₹2,60,400 | 1,955 ₹3,28,440 |
| 5.00 | M&L 100mm thick, plain cement concrete (1:3:6), type C-2 (using 40 mm graded mechanically crushed stone aggregates), as in path/hardstanding including making joints @ 3.00 metre intervals and at each corner, the joint shall be filled with mastic filling (to full depth) comprising of one part heated hot blown bitumen 85/25 & two parts heated sand (by volume), surface finished even and smooth without using extra cement complete all as specified and as directed. | 200 | Sqm | 595 ₹1,19,000 | 875 ₹1,75,000 | 590 ₹1,18,000 | 568 ₹1,13,600 | 620 ₹1,24,000 | 710 ₹1,42,000 | 550 ₹1,10,000 Lowest | 614 ₹1,22,800 |
| 6.00 | M & L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate bring upto the slope by providing filling of light weight materials such as cinder, light weight concrete etc as required average 40mm thickness complete all as pspecified and directed. | 100 | Sqm | 210 ₹21,000 | 195 ₹19,500 | 261 ₹26,100 | 255 ₹25,500 | 310 ₹31,000 | 195 ₹19,500 | 170 ₹17,000 Lowest | 265 ₹26,500 |
| 7.00 | M&L Vitrified Ceramic tiles 10 mm thick, dark shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer, 15 mm thick in Cement Mortar 1:6 complete including dismantling of existing tile and disposal off to outside MD land all as specified and as directed. | 300 | Sqm | 2,200 ₹6,60,000 | 1,955 ₹5,86,500 | 2,000 ₹6,00,000 | 2,014 ₹6,04,200 | 2,132 ₹6,39,600 | 2,250 ₹6,75,000 | 1,950 ₹5,85,000 Lowest | 2,345 ₹7,03,500 |
| 8.00 | M&L Vitrified Ceramic tiles 10 mm thick, dark shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in vertcal surfaces such as skirting/ dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer ,10 mm thick in Cement Mortar 1:4 complete including dismantling of existing tile and disposal of to outside MD land all as specified and as directed. | 30 | Sqm | 1,874 ₹56,220 | 1,850 ₹55,500 | 1,650 ₹49,500 | 1,987 ₹59,610 | 1,900 ₹57,000 | 1,834 ₹55,020 | 1,910 ₹57,300 | 1,480 ₹44,400 Lowest |
| 9.00Note for item No 7 & 8 :- (i) Vitrified tiles are classified under group B1a of the international Standard for ceramic tiles ISO: 13006. Tiles shall be hard, dense, impervious and frost resistant. Water absorption of tiles shall be less than 0.5% and flexural strength (Modulus of Rupture) shall be more than 35 N/Sqmm. (ii) The manufacturer's test certificate and individual test certificate of Tiles must be submitted for approval by the concerned authority prior to installation. | |||||||||||
| 10.00 | M&L Glazed ceramic coloured tiles 450 x 300 mm x 7/8 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles on vertical surface such as dado including 10mm thick 1:3 backing coat including taking down existing tile and removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. | 140 | Sqm | 1,784 ₹2,49,760 | 1,790 ₹2,50,600 | 1,650 ₹2,31,000 | 1,810 ₹2,53,400 | 1,500 ₹2,10,000 Lowest | 1,850 ₹2,59,000 | 1,750 ₹2,45,000 | 1,890 ₹2,64,600 |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
15 Dec 2025, 6:00 pmClosed
GE AF SULUR
GE AF SULUR KANGAYAMPALAYAM
REPAIR AND MAINT TO HARD STANDING PATH CULVERT AND MISC B AND R WKS IN DOMESTIC AREA AND REPAIR AND MAINT OF DAY TO DAY COMPLAINTS OF VARIOUS LIGHTS AND OTHER MISC EM WORKS AT AF STN SULUR
2025_MES_740617_1
8813/E8
Open Tender
Miscellaneous Works
Item Rate
300 days
GE AF SULUR
As per tender documents
7 documents required · 7 mandatory
₹1,000
Yes
GE AF SULUR
₹1.5 L
Yes
5 Feb 2026
20 Nov 2025
17 Dec 2025
20 Nov 2025
15 Dec 2025
8 Dec 2025
22 Nov 2025 - 5 Dec 2025
Amount
SCHEDULE A BOQ
M&L for demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)
M&L 100 mm thick Plain cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate ) as in sub base , fillng and mass concrete or as in receiving tiles/ surface channels and drains etc complete all as specified and directed.
M&L Chequered cement concrete tiles 30cmx30cmx25mm thick machine pressed set jointed and pointed in neat cement slurry as in floors and cut and polished using grey cement and pigments over screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:4) including demolishing the existing tile complete all as specified and directed Note : The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation/fixing.
M&L 100mm thick, plain cement concrete (1:3:6), type C-2 (using 40 mm graded mechanically crushed stone aggregates), as in path/hardstanding including making joints @ 3.00 metre intervals and at each corner, the joint shall be filled with mastic filling (to full depth) comprising of one part heated hot blown bitumen 85/25 & two parts heated sand (by volume), surface finished even and smooth without using extra cement complete all as specified and as directed.
M & L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate bring upto the slope by providing filling of light weight materials such as cinder, light weight concrete etc as required average 40mm thickness complete all as pspecified and directed.
M&L Vitrified Ceramic tiles 10 mm thick, dark shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer, 15 mm thick in Cement Mortar 1:6 complete including dismantling of existing tile and disposal off to outside MD land all as specified and as directed.
M&L Vitrified Ceramic tiles 10 mm thick, dark shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in vertcal surfaces such as skirting/ dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer ,10 mm thick in Cement Mortar 1:4 complete including dismantling of existing tile and disposal of to outside MD land all as specified and as directed.
Note for item No 7 & 8 :- (i) Vitrified tiles are classified under group B1a of the international Standard for ceramic tiles ISO: 13006. Tiles shall be hard, dense, impervious and frost resistant. Water absorption of tiles shall be less than 0.5% and flexural strength (Modulus of Rupture) shall be more than 35 N/Sqmm. (ii) The manufacturer's test certificate and individual test certificate of Tiles must be submitted for approval by the concerned authority prior to installation.
M&L Glazed ceramic coloured tiles 450 x 300 mm x 7/8 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles on vertical surface such as dado including 10mm thick 1:3 backing coat including taking down existing tile and removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile of size exc 0.09 Sqm but n exc 0.18 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incuding screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:4) and dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as directed.
Note for item No 10 & 11 :- The manufacturer's test certificate of Tiles must be submitted for approval by the concerned authority prior to installation.
M&L Granite work (of any type) 18 to 20mm thick (table rubbed and polished including round edge) in steps, jambs, pillars, window cills, cooking platforms, wash basin platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with granite shade and including Stone slabs and tiles of any description or thickness in floors, aprons etc. in repairs complete all as specified and directed by Engineer-in-Charge.
M&L Taking down cement plaster on brick or stone walls, or concrete or ceilings etc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises, removal and depositing serviceable materials where directed and leaving the work clear of any plastering and material and labour for Rendering 15 mm thick in two layers on brick or stone or concrete surfaces,first coat 10mm thick in cement mortar 1:4 and 2nd coat 5mm thick in cement mortar 1:4 mixed with water proofing compound as per manufacturer instructions finished even and smooth without using extra cement complete all as specified and directed.
Note for Item No 14 :- (a) Supply only water proofing compound shall be measured and paid seperately.
Supply Only integral water proofing compound complete all as specified and as directed.
M&L Preparation of new plastered surfaces wall applying two coat of Oil emulsion distemper over a coat of alkali resistant priming paint complete all as specified and directed.
M&L Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; including dismantling of floor , hearth or wall tiling as specified and directed.
M&L Hardcore of gauge not exceeding 63 mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface including removal of existing complete all as specified and directed.
M&L in repairs Machine cut kota stone slab flooring 20-25mm thick over cement 25mm screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including screed bed or bedding layer, 15 mm thick in Cement Mortar 1:4 including Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation, cesspits, manholes, pier holes, etc. and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed.
Removal of excavated material to a distance exceeding 1.50 Km and not exceeding 5.00 Km and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Demolition of brick work masonry, built in cement mortar including all quoins, pillars etc., complete all as specified and as directed.
M&L Brickwork with fly ash’ bricks using with old size bricks, straight or curved on plan exc 6m mean radius built in cm 1:4 , complete all as specified and as directed
All as per item No 25 here in above but except bricks. Note:Serviceable bricks obtained from Demolition be reused.
Demolition of cement concrete (reinforced) in of any description and in any position and removal of debris out of MD land complete all as specified and directed.
M&L Precast RCC 1:2:4, Type B–1 using 20mm graded stone aggregate as in landings, cover slabs [for manholes etc], chullah hoods, Chajjas, water troughs, mangers, Shelves and similar articles with plain faces complete all as specified and as directed.
S&F High strength corrosion resistant TMT bars of Grade Fe–500D of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified.
M&L PCC (1:2:4) Type B1 (using 20 mm graded stone aggregate) as in coping of including necessary form work finished fair and even surface without using extra cement including weathering slightly rounded or chamfered angles and throating complete all as specified and as directed.
Excavating in post holes (or similar holes) in hard and dense soil, each not exc 0.5 cum, getting out in hard dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm including demolition of existing damaged foundation of fencing posts complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed.
S&F Mild steel work in framed work such as grills and similar work including framed guard bars, barred iron doors, ladders, framed balusters etc., including of fixing of sheet steel or other covering to doors etc., to be prepared for hanging /sliding with or including either hooks or hinges or steel hanging door fittings etc., confirming to Fe 410-0 or Fe 310-0 work complete including Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed.
M&L M S angle iron Posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
M&L Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other to be fitted with washers and one hexagonal or square nuts, n exc 5cm long diameter of neck 5 to 10mm including taking down existing one complete all as specified and as directed.
M & L for pre-cast cement concrete block masonry with solid blocks of cement concrete exc. 10 cm width and setting in cement mortar 1:6 type C-1, 1:3:6 (using 20 mm graded stone aggregate) complete
M&L PCC 1:4:8, type D-2, using 40mm graded stone aggregate in foundation filling and mass concrete etc complete all as specified and as directed.
M&L Plain Cement concrete 1:3:6,type C-2, (using 40mm graded crushed stone aggregate) as in foundation of fencing post, filling and mass concrete etc complete all as specified and as directed.
M&L preparation of old decorated plastered or unplastered surface of wall, brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , treading, oil, greasy spots and applying one coat cement base paint complete all as specified and as directed.
M&L Machine pressed precast concrete interlocking paver block with greay cement and pigment any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade laid over and incl dismantling of existing tiles all as specified and directed. Note : The Unit rate quoted is included for Demolition of paver tiles of any description or thickness in floors,aprons etc laid bedded and pointed in any mortar and removing of debris outside of MD land
S&F Mild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 gradeSt.-240) complete all as specified and as directed.
S&F Mild Steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted ,bolted or welded attachment.(Fe 410 -W (Gde- E-250) quality -A complete including dismantling existing one all as specified and as directed.
M&L Pre painted Coloured Galvalume roofing system sheet 0.50 mm thick having Zinc aluminum alloy coating AZ150 shall be as per IS:277/ASTM 1379 150 gsm/ sqm double ribbed trapezoidal profile steel sheet any colour having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws including dismantling of existing one all complete all as directed.
M&L Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws including dismantling of existing one all as directed.
Note for pre-painted coloured Galvalume roofing :-
(i) The manufacturer's test certificate and individual test certificate for the chemical and mechanical properties of sheet must be submitted for approval by the concerned authority prior to installation.
(ii) The contractor shall ensure that no leakages take place from the roof. The roofing shall be Coloured Galvalume roofing system (olive green colour or as approved by GE) with feed material manufactured from 0.50 mm Total coated thickness (TCT), minimum 550 MPa yield strength and shall conform to the physical specifications of IS: 2062 of 2011, coated with hot dip metallic Aluminium / Zinc alloy coating AZ150 as 150 gm/sq.mt total on both sides complete all as specified and as directed.
(iii) The painting shall be coloured baked enamel polyester with silicon coating of film thickness 25 microns nominal on the exposed face/exterior side and on the reverse side ( interior face) shall be white with 15 microns film thickness, over a coat of 5 micron nominal thickness Primer.
(iv) The contractor shall produce purchase vouchers for each lot and independent test for verification of Engineer-in-Charge.
Bullnosed chequered cement concrete tiles 30cm x 30cm x 25mm thick machine pressed set jointed and pointed in neat cement slurry as in treads and cut and polished using grey cement and pigments over screed bed or bedding layer of mortar 15mm thick for laying floor fnishes in cement mortar (1:4) including taking down existing tiles complete all as specified and as directed by Engineer-in Charge. Note :- The manufacturer's test certificate and individual test certificate of tiles must be submitted for approval by the concered authority prior to installation
M&L Taking down cement plaster on brick or stone walls, or concrete or ceilings etc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises, removal and depositing serviceable materials where directed and leaving the work clear of any plastering complete all as specified and directed.
M & L for Rendering 15 mm thick in two layers on brick or stone or concrete surfaces,first coat 10mm thick in cement mortar 1:4 and 2nd coat 5mm thick in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 15 mm thick in two layers on stone masonary surfaces or surface otherthan fair face of brick-work or on one side of lathing, first coat 10 mm thick in CM 1:6 and 2nd coat 5 mm thick in CM 1:6 finished other than fair face without using extra cement complete all as specified and directed.
M&L Preparation of new plastered surfaces wall and applying two coat of white wasing on ceiling/ walls surfaces complete all as specified and directed.
M&L Preparation of new plastered surfaces wall applying two coat of Oil emulsion distemper over a coat of alkali resistant priming paint complete all as specified and directed.
M&L Dismantling and re-fixing barbed wire of any description straining and fixing to any type of standrard rails including securing or tying at crossing with and provision of galvanised mild steel wire ,stapple or steel pins complete all as specified and as directed. (Note: Each line of wire to be measured).
S&F in repairs Galvanised steel punched type concertina coil 1050mm dia (dia of coil with unstreched) and streched for a length of 6RM/ Coil while fixing and fixed to angle iron posts/ supports binded with 3.15mm dia GI wire complete all as specified and directed. Note :- Weight of one coil, with 50 Turns of 1050mm dia and 129 number clips shall not be less than 15.2 Kg.
Supply only Chain link mesh, made of galvanised wire and shall confirm to IS 2712.2003 and having zinc coating of type heavy as laid down in IS 4826 including binding wire etc fixed to any type of standards posts complete all as specified and as directed.
M&L in repairs Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins, etc complete all as specified and as directed Note :- Each line of wire to be measured.
S&F 6 mm thick, corrugated polycarbonate transparent sheet with UV coating of 40 microns ensuring light transmission not less than 85 % weather & heat resistant and tesile and break up strength as per relevent IS, side lap fixed with self tapping screws/J hooks 8mm dia and aluminium sectionsin lapping portionetc., in roof, wall etc complete including taking down all as specified and as directed.
Dismantling boarding, any description, fixed in any position with nails complete
S & F in repairs 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and directed.
S& F in repairs both side Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed.
S & F in repairs Hat and coat hooks, solid body, 175mm to 250 mm complete
Disconnecting & taking out unserviceable one and replacemet with new LED aviation obstruction light with IP 66 protection water clear poly carbonate UV stabilized dome neoprene rubber with bind spike with 302 Nos LED bulbs including necessary electric connections including 2.5 sqmm, 2 core, PVC copper cables fixed on wall with 20mm dia PVC conduit from DB to light fitting fixed in and including GI pipe 25mm dia 1 mtr long grouted with PCC complete/ binding with existing angle frame etc complete including taking down existing one complete all as specified and directed
Attending unserviceable/ non functional street light complaints (for street light/perimeter lights/high mast light/flood light etc of any type/size fitted on poles/walls/post/pillars etc) by deploying technically qualified and experinced techinicians to find out defective/taking out unserviceable parts such as electronic driver, pvc insulated copper conductor cable for connecting street light fittings etc and repairing by changing the defective parts including minor repair to cable connection/loose connection, screws,nuts & bolts and insulation tap to insulate the LT joint etc and testing complete all as specified and as directed for at complete AF Station(both domestic & technical area) Sulur
Note for item No 66 : The following items are deemed to be inclusive of quoted rate :-
(a) The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced before commencement of work.
(b) 'Supply only' items to be delivered/ supplied to AGE E/M store yard as per qty asked by Engineer-in-Charge with in one calender month from the date of commencement of contract and these items will be issued from AGE E/M store yard for attending unserviceable/ defective street light complaints.
(c) Contractor or his Authorised Representitive has to inspect all Street/ Security Lights on Daily basis at their own arrangement between 7.00 PM to 9.00 PM and maintain the record in Register which will be put up to Engineer-in-Charge/ JE on the very Next day.
(d) A Joint Inspection for Serviceability of all Street/Security Lights will be carried out from 7.00 PM to 9.00 PM on every Friday by Engineer-in-Charge/ JE (E/M)/ User alongwith Contractor or his authorised Representitive.
(e) Contractor has to arrange own moveable Generator of suitable capacity for repairing and testing of the Street/ Security Lights, defect rectification of Cables, etc. and to check the serviceability after repair. No Electricity shall be provided by the Department on this account.
(f) Quoted Unit Rate shall deemed to be inclusive of attending any breakdown of Street/ Security Lights during night. Contractor has to arrange Electrician and Helper and all necessary T&P and Equipments to remove the breakdown. Fault will be intimated through Telephone/ SMS.
(g) In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent work, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
(h) The penalty shall be applicable to the contractor if the delay is noticed by the Engr-in-Cahrge more than twelve hrs after handing over works of urgent nature to the contractor. The Engr-in-Charge shall handover the slip containing specification of work to the contractor by lodging the time and signature of contractor be obtained on slip. The contractor shall attend the complaint immediately and shall report to Engr-in-Charge with in 12 hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive. If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Charge and the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 50/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforceabove as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. The decision of the Accepting Officer is this regards shall be final and binding.
(j) Contractor has to ensure serviceability of all Street/ Security Lights of DOMESTIC & TECHNICAL AREA on Daily basis in any Weather Condition at their own arrangement.
(k) Contractor shall provide conveyance to the deployed labour for maintaining the services without any extra cost to department.
(l) Vehicle mounted ladder for maintaining services shall be provided by the contractor at no extra cost to department.
(m) Materials required for the repairing of the lights shall be measured and paid separately under respective item(s). But labour required for taking down, dismantling, repairing and replacing parts and reinstalling and testing the street lights fittings shall deemed to be included in the rate quoted.
(n) Necessary T&P, Safety Belt, Vehicle, Aluminium Ladder, etc. will be arranged by the Contractor and Cost for the same shall deem to be included in the Quoted Unit Rate.
(o) All safety measures and provn of all safety devices, first aid box etc shall be provided by the contractor. Contractor will be solely responsible for full safety of the persons deployed for providing the services and department will have no liability for any type of accident/injury of any type. Unit rate quoted will be deemed to include the cost of the same and no extra payment shall be made on this part.
(p) All type of T & P, PVC insulation tapes, minor nuts/ bolts/ washers etc required for maintaining the services shall be provided by the contractor without any extra cost to department.
(q) Attending and repairing complaint for one light of any type shall be measured and paid as one Job.
(r) Earth work (if necessary at Site) for removing of any Cable Fault will be Measured and Paid under respective Items.
(s) The contractor shall maintain a record of all urgent work at and if the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the Govt.
(t) Contractor shall provide contact details of his responsible person(s) for any emergency.
(u) Any Materials replaced which are not specified in SCHEDULE OF CREDIT will be deposited to MES STORE YARD without any extra Cost to the Department.
Disconnecting & taking out unserviceable one and replacemet with new electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 10 to 25 watt, complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 30 to 45 watt, complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 60 to 90 watt, complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 100 to 110 watt, complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 120 to 140 watt, complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 140 to 160 watt, complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 180 to 210 watt, complete all as specified and as directed.
M & L for disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tapes etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box complete all as directed for the 25/ 35 sqmm 3.5 core size of LT underground armoured cables complete all as specified and directed.. Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall be deemed to be included in the unit rate quoted.
Disconnecting & taking out unserviceable one and replacemet with new GI tubing 40/50 mm bore light grade 1.2 mtr long bent to shape as required with clamps for fixing of street light on poles/ walls including nuts, bolts, washers clamps of suitable size including taking down existing one complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new Single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 including taking down existing one complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed..
Disconnecting & taking out unserviceable one and replacemet with new TPN, MCB 40 to 63 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 complete all as specified and directed.
Excavation in trenches in hard/dense soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth for laying of cable and not exceeding 10 Sqm on plan for poles, struts, stays etc. and not exceeding 1.5 m in depth and getting out complete all as specified and directed
Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming complete all as per specified and as directed.
Note for item No 80 :- In case sufficient sand not obtained from excavation, the rate is deemed to be inclusive for additional qty of sand required to be obtain from out side MD land as directed by the Engineer-in-Charge.
Removing excavated materials not exceeding 50m distance and depositing where directed at level not exceeding 1.5 m above the starting point complete all as per specified and as directed.
S&F Fly ash bricks using modular bricks as in cable protection cover including taking down existing bricks of any size complete all as per specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soil all as specified and as directed.
S&F XLPE insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 25 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed.
Note for item No 84: Excavation and earth work shall be measured and paid seperately.
Disconnecting & taking out unserviceable one and replacemet with new Cable jointing kit for 1.1 KV grade cable for outdoor stright through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armored aluminium conductor cable of size 10 sqmm to 16 sqmm.
M & L for cutting existing road/PCC/Drain for laying of DI/GI or any typeof pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, wide 800mm including making existing surface with PCC 1:2:4 type B1 using 20mm aggregate thickness of concrete is 150mm complete all as specified and directed.
Note for item No 86:- The tenderer shall take into consideration for following points while quoting his rate for this item and the unite rate is deemed be included for :-
(i) Earth work excavation in any type of soil
(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed.
(iii) Removing excavated material to out side MD land
(iv) Laying of any type/any bore of pipe in trenches including taking down any description. Supply of pipe will be measured and paid separately
(v) 150 mm thick PCC 1:2:4 type B1 as in any type of road
(vi) GI pipe required for cable protection shall be measured and paid separately under respective item. But labour required for take the cable through GI pipe and laying in trench shall deemed to be included in the rate quoted.
Disconnecting & taking out unserviceable one and replacemet with new GI pipe 50 mm bore medium grade for cable protection complete all as specified and as dierced by Engr-in-Charge.
M & L for preparing the existing painted steel surface and painting with one coat of aluminium paint on cross arms, clamps, MS flat and street light brackets if any on Steel / RCC pole for Double cross Arm for three Phase 4 wire system.
Disconnecting & taking out unserviceable one and replacemet with new LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed..
S&F XLPE insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 16 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed.
Note for item No 90: Excavation and earth work shall be measured and paid seperately.
Disconnecting & taking out unserviceable one and replacemet with new steel tubular swaged poles of 9 mtr long type 410 SP- 31 IS-2713 marked complete with CI/ MS base plate, finial taper plug, bolts, nuts, washers and screws as specified, drilling of necessary holes including painting with two coats of aluminium paint over a coat of red oxide primer on exposed surface and black bituminous paint on steel surface embeded in conrete externally and throughout internally and painting 03 nos of band /strips with fluorescent , PO box red synthetic enamel paint (30 cm wide each) at a distance of 30 cm from plinth block and number of poles including taking down existing one complete all as specified & directed by Engineer-in-Charge.
Note for item No 91.01 :- Earth work excavation, PCC foundation, coping will be measured and paid separately. The rate for pole shall also be included painting to steel tubular pole (in side and out side).
M&L cement concrete 1:4:8,type D2 (using 40mm graded stone aggregate ) including necessary form work for pole foundation complete all as specified and directed by Engr-in-Charge .
M&L cement concrete 1:3:6 type C2(using 40mm graded stone aggregate) including necessary form work for pole foundation complete all as specified and directed by Engr-in-Charge .
M&L PCC 1:2:4 type B-1 using 20mm graded stone aggregates as in pole coping ccomplete all as specified & directed
Disconnecting & taking out unserviceable one and replacemet with new Power contactors 63 Amps, 4 pole, 415V, including taking down old item complete all as specified and as directed.
M & L for preparing the painted steel surfaces of existing LT/steel tubular pole including cross arms, clamps MS flats, steel light bracket if any etc and applying one coat of aluminium paint(above ground/coping level) not exc 8 mtr long including painting of strips of height 0.3mtr each (three nos sky blue and three nos white), tightening of cross arms, clamps and street light brackets complete all as specified and directed.
S&F XLPE insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 10 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed.
Note for item No 97 : Excavation and earth work shall be measured and paid seperately.
Disconnecting & taking out unserviceable one and replacemet with new LED street light fittings energy saving luminaire with lens , capacity 45 watt with system efficacy (lm/w) shall be 100 lumen per watt or more lumens per watt, total system lumen not less than 4500 lumens, PF not less than 0.95, CRI not less than 70, colour temp. 5000K to 6500 K, surge protection not less than 5 KV, high pressure die cast aluminium alloy LM6 housing IP-65/66 class 1 protection, toughened glass cover, driver efficiency > 85% with constant output of current and voltage against input voltage variation 120 to 270 volt at 50 Hz ( + 5%), THD< 10% complete including taking down existing complete all as specified and directed.
S&F XLPE insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 10 Sqmm 2 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately.
S&F XLPE insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 6 Sqmm 2 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed.
Note for item No 100: Excavation and earth work shall be measured and paid seperately.
Disconnecting & taking out unserviceable one and replacemet with new Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete
Disconnecting & taking out unserviceable one and replacemet with new synchronising electronic timer unit operated on AC 230 Volts, 24 hrs clock time for controling street lights including taking down old unserviceable timer switches complete all as directed.
M & L cleaning of existing solar street light panels fixed above street light pole of approximate height 6 meter by using wet cloth dipped in soap water including the panel perimeter complete all as specified and directed.
Note for Item No 103:- (i) The contractor shall be responsible for arrange necessary conveyance vehicle, Aluminium self supporting ladder/bamboo ladder, bucket, soap powder, cloths etc and the quoted rate shall be deemed to be inclusive for the above.
(ij) Contractor has to ensure serviceability of solar street light panel of DOMESTIC & TECHNICAL AREA on Daily basis in any Weather Condition at their own arrangement.
(iii) Contractor shall provide conveyance to the deployed labour for maintaining the services without any extra cost to department.
(iv) Vehicle mounted ladder for maintaining services shall be provided by the contractor at no extra cost to department.
(v) Necessary T&P, Safety Belt, Vehicle, Aluminium Ladder, etc. will be arranged by the Contractor and Cost for the same shall deem to be included in the Quoted Unit Rate.
(vi) All safety measures and provn of all safety devices, first aid box etc shall be provided by the contractor. Contractor will be solely responsible for full safety of the persons deployed for providing the services and department will have no liability for any type of accident/injury of any type. Unit rate quoted will be deemed to include the cost of the same and no extra payment shall be made on this part.
M & L for cleaning vegetation around the LT pole completely root out from soil and clean the surface one mtr around the pole of street lights complete all as specified and as directed.
Note for item No 104 : Removing of accumulated earth depth upto 15cm cleaning / Cutting the grass with hand operated petrol/ kerosene driven grass cutting machine and removing the grass waste to outside MD land is deemed to be included in quoted rate.
Disconnecting & taking out unserviceable one and replacemet with new Power contactors 40 Amps, 4 pole, 415V, including taking down old item complete all as specified and as directed.
M & L for preparing surfaces by removing exisiting faded sky blue and white straps on PCC poles and applying a coat of sky blue/white straps painting with synthentic enamel paint, each sky blue/white straps of 30 cm height up to 1.5 mtr from top of PCC coating, writing pole no with white paint on black base of PCC pole by sentensile measure including applaying one coat of synthetic enamel paint to clamps/cross arm/street light GI bracket fixed on pole complete all as specified and as directed
Disconnecting & taking out unserviceable one and replacemet with new PVC insulated Copper Conductor Cable 1.5 Sqmm, 3 Core Round Flexible for connection of Street Light Fitting, complete all as specified and as directed.
M&L Sub main wiring for circuit complete with 2 runs of 1.5 sqmm single core PVC insulated, unsheathed FRLS 1100 Volt grade multi stranded copper conductor cable drawn through and incl suitable size non metalic PVC Conduit and accessories complete fixed surface to wall/roof/ceiling etc and 1 run of 1.5 sqmm single core PVC insulated, unsheathed FRLS 1100v grade multi stranded copper conductor cable as earth continuity conductor etc including taking down existing submain wiring complete all as specified and directed.
Note for item No 108:- Two runs of power cable , one run of earth conductor and one run of PVC conduit/casing capping will be measured as one length.
Disconnecting & taking out unserviceable one and replacemet with new Connector suitable for fixing of Cable of size Cross sectional area 10 Sqmm to 25 Sqmm armoured/PVC for preventing of Short Circuiting of Cable in Junction Boxes, complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new IP 66 Thermoplastic PC- GFS Polycarbonate weatherproof Junction Box size 255L x 205B x 112D MM with plain walls for cable entries to be drilled individually, system voltage : 415V, 50hz, The plain side walls on the four sides can be drilled and customized for cable entries from any direction. Lid fasteners shall not have screws but shall be with quarter turn locking knobs – which is well visible ( open – locked), and they will be sealable without any accessories. Cable terminal :- 25 Sq mm- 4 no with 10A SP MCB- 1 no, 6sq mm disconnected terminal- 1 no, The junction box shall fulfill the following standards Weather proof : UV resistant due to solar radiation, Rainwater proof, temperature resistant.Salt water proof & shall be suitable for off-shore applications. IEC 60670-22 : Particular requirements for connecting boxes and enclosures. IEC 60695 – 2 – 11 : Flame – retardant & Self-extinguishing. Glow Wire tested at minimum 960 deg C. IEC 60529 : IP 66 / IP 67 / IP 69 degree of protection including taking down existing all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new LED flood light fitting 70 Watts 240 Volts, (suitable for fixing on pole/ wall) with secondary optics made in pressure die cast housing with heat sink and aluminium extrusion with IP 66 class of protection complete with control driver and all accessories with high quality lenses, reflector, and toughened glass, power factor > 0.95, Luminaire lumen output - 8200lm, operating voltage range from 140V to 270V at 50 Hz AC Frequency, Temperature range-40 to +70 deg Celsius, driver efficiency > 85%, THD<10%, CRI>70%, Colour temperature 5700K, Surge protection from overvoltages 4kV internal and 10kV external, 50000 burning hours, Luminaire efficacy-110 lm/w complete all as directed. Make : Philips Cat No BVP192 LED 82 CW HO NB FG GR PSU or Equivalent in approved make in PS
Disconnecting & taking out unserviceable one and replacemet with new LED flood light fitting 170 Watts 240 Volts, (suitable for fixing on pole/ wall) with secondary optics made in pressure die cast housing with heat sink and aluminium extrusion with IP 66 class of protection complete with control driver and all accessories with high quality lenses, reflector, and toughened glass, power factor > 0.95, Luminaire lumen output - 17600lm, operating voltage range from 140V to 270V at 50 Hz AC Frequency, Temperature range-40 to +70 deg Celsius, driver efficiency > 85%, THD<10%, CRI>70%, Colour temperature 6500K, Surge protection from overvoltages 4kV internal and 10kV external, 50000 burning hours, Luminaire efficacy-110 lm/w complete all as directed.
Disconnecting & taking out unserviceable one and replacemet with new convetional type post top fitting with LED Post tops lamp fitting 1x45 W LED made die cast aluminium with innovative glare free indirect lighting ditribution & IP 65 protection inlcuding fixing arrangement with suitable flanged GI pipe base and PCC fixed on floor/ground complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new ALCOR LED flood light, 50 watts RGB colour changing light, 240 Volt, with high quality lenses & reflector, High grade aluminium pressure Die-Cast Housing with toughened glass cover, IP-66 class of protection, complete with control gear and all accessories including necessory PCC foundation for placing of flood light complete all as specified and directed by Engr in charge.
Disconnecting & taking out unserviceable one and replacemet with new pathway light decorative retrofit LED fitting with 9 W LED bulb including necessary excavation, PCC foundation, 1.5 mtr long GI pipe light grade 50 mm bore with base plate, cable junction box with 2 pole connector 32 A capacity including cable entry and exist knockouts, 1.5 mtr length 3 core 1.5 sqmm PVC insulated copper round cable from connector to light fitting, disposal of soil to outside MD land complete all as specified and directed by Engineer-in-Charge.
Disconnecting & taking out unserviceable one and replacemet with new convetional type boolard fitting with LED bollard light fittings suitable for 1x9 watt LED bollard in rectangular shaped vicotria design with opal acrylic diffuser and IP 65 protection inlcuding fixing arrangement with suitable flanged GI pipe base and PCC fixed on floor/ground all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new Revolving search light 300 W LED High intensity, long range, weather proof, energy saving, instant glow, LED search light, beam range 700 meters (as per model), Single LED light, Efficiency >140 lm/w, PF >0.95, CCT ~ 6000K, Optical grade PMMA-PC lens, narrow beam 8 degree, die cast LM6 body with air fins, toughened front glass sealed with silicon gasket, fully powder coated, wide range of working voltage 90 - 300 AC, protection against over volt & under volts, reflector lens efficiency >90%, average lux level at 10 meter is approx. 2000 - 6000 lux (as per model) with circle of approx 1meter, confirming to LM79 & LM80. This search-light is ready to installed on rotating disc of auto revolving mechanism. Degree of protection : IP65 and the stand would be suitable for mounting of search lights on its rotating disk on top side. It is made of iron/steel with epoxy powder coating weather proof paint on surface. The stand has designed so that the search light can be rotate one full round horizontally and 30 degree vertically & can be locked at any position at any time. It would be 4 nos. high grade PVC castor wheels at bottom for easy movement on the platform with wheel locking arrangement. The height of tripod stand is generally 1 Meter above from the bottom.
Disconnecting & taking out unserviceable one and replacemet with new Integrated solar street light of less than 20W with 4500 lumen and system lumen efficiency of more than 170 lumen per watt. The luminaire shall use highly efficient microcontroller based integrated MPPT charge controller, both charger and driver to be on same board with more than 90% efficiency of both charger and driver. High grade aluminium die-cast housing to ensure good heat dissipation. The luminaire shall have flexi mount of 0 to 15 degree to adapt to certain geography diversity. The luminaire shall be with smart self-diagnosis feature with LED indicators alongwith battery charging and deep discharging out off indications. The system shall use long time maintenance free lithium Ferro Phosphate (Li Fe PO 4) battery with BIS certification. Battery capacity of minimum 170 wh for autonomy of 24 hrs with fully charged battery. The luminaire shall be with hybrid feature (integrated/ seperated) ON-OFF switch, Outer mounting diameter of 48-60 mm. Operating temp range for light engine is 0 to +35 Dep C. operating humidity shall be upto 95%. System lumen output should be atleast 12V DC, 2000 lm. Solar panel module capacity of 12V, 35W Peak Mono-crystalline. Solar cell efficiency with min 12%. LED burning hrs to be 50,000 hrs at L70. Rating of IP 65 and IK 08 to comply with UV stabilized poly carbonate front cover. Colour temp of 5700K and CRI > 70 including taking down existing one all as directed. Note :- The unit rate is deemed to included for 6 mtr long MS/GI pipe of 50MM bore medium grade including necessary excavation, PCC foundation, coping, base plate and bend to shape and size suitable for fixing of above fitting all as specified and directed by Engr-in-Charge
Notes for Item No 118:- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report including BIS certification. (b) The contractor shall submit warranty certificate from manufacturer for minimum 5 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract. (d) The contractor shall also submit safety and performance standard compliance of IEC 60598-2-3 for road and street lights, IEC 62109-1 for power converters used in Solar Panel, EN 50530 for MPPT performance evaluation, IEC 61607 for EMC immunity, CISPR 15 for Radio disturbance characteristics, IEC 62133, IEC 61960 and UL 1642 for safety of lithium Ferro Phosphate battery and IEC 61730-1, 2 & IEC 61215 for safety of solar panel module. (e) The rates quoted deemed to be included 6 mtr long GI pipe of 50mm bore medium grade including necessary excavation, PCC foundation, coping, base plate and bend to shape and size suitable for fixing of above fitting all as specified and directed by Engineer-in-Charge.
Disconnecting & taking out unserviceable one and replacemet with new Triglow rope light 18 mtr length IP 65 water plug and play strip light for republic day and independence day celebration showcausing patriotism for India . Indian tricolour strip light - orange +whitw+green colour in single strip . Wattage -6W/Meter Lumen output 400lm/meter, input volt- 220V to 240V all as directed.
Disconnecting & taking out unserviceable one and replacemet with new twin core 4 Sqmm service wire 1100V grade heavy duty with PVC insulated aluminium stranded conductor served with inner sheatning of PVC tape and PVC sheathed including taking down old unserviceable service wire complete all as directed.
Disconnecting & taking out unserviceable one and replacemet with new twin core 6 Sqmm service wire 1100V grade heavy duty with PVC insulated aluminium stranded conductor served with inner sheatning of PVC tape and PVC sheathed including taking down old unserviceable service wire complete all as directed .
Disconnecting & taking out unserviceable one and replacemet with new twin core 10 Sqmm service wire 1100V grade heavy duty with PVC insulated aluminium stranded conductor served with inner sheatning of PVC tape and PVC sheathed including taking down old unserviceable service wire complete all as directed.
Cutting and trimming trees branches any girth and any size covering street lights mpunted on pole/wall/building and cleaning the distance 1.5 mtr dia, each disposing the same, clearing the site all as directed . Note: 05 Nos of Lights shall be measured as one job.
Disconnecting and taking out old unserviceable LED street light fitting from its existing locations and Supply and fixing of complete new LED security lights 60W with electronic driver with lumen efficency not less than 110 lum/watt,High performance low wattage street light with Housing high pressure die cast aluminium, high power LED light source, IP66 protection,PDC housing with finless design and high impact resistance (IK08) or higher impact resistance Polycarbonate/glass cover with integrated street Light optics,replaceable driver with minimum 4kV surge protection,THD < 10%, PF not less than 0.95, operating voltage 140-270Volts,50HZ with permisible CRI rannge of balance energy efficiency and visibility compitable for mounting on pole and Gi tubing dia 32-50mm dia , including necessary screws,nuts,bolts of suitable size and necesary wiring from light to Junction Box complete all as directed
Disconnecting and taking out old unserviceable LED street light fitting from its existing locations and Supply and fixing of complete new LED security lights 90 W with electronic driver,multiple optics with lumen efficency not less than 110 lum/watt,High performance low wattage street light with Housing high pressure die cast aluminium, high power LED light source, IP66 protection,PDC housing with finless design and high impact resistance (IK08) or higher impact resistance, Polycarbonate/glass cover with integrated street Light optics,replaceable driver with minimum 4kV surge protection,THD < 10%, PF not less than 0.95, operating voltage 140-270Volts,50HZ with permisible CRI range of balance energy efficiency and visibility compitable for mounting on pole and Gi tubing dia 32-50mm dia , including necessary screws,nuts,bolts of suitable size and necesary wiring from light to Junction Box complete all as directed
M&L for Dismantling foundation of LT pole of any height by taking out from PCC foundation complete and shifting to other location as directed including fixing the pole in true vertical position including excavation and earth work, PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as base concrete and PCC 1:3:6 type C2 (using 20mm graded stone aggregate) in both foundation and coping of poles all as specified in SSR Part I-2009 and applying two coats of aluminium paint to pole surface complete all as directed by Engineer-in-Charge.
M&L for Meggering of LT UG cable between Span to Span/, any type connection with complete diconnection & reconnection the same for checking of fault and rectification for any size any place after disconnection of Supply complete.
M & L cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and morrum filling including excavation for laying of cable pipe all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.
KRISHNA ENTERPRISES (BID ID -3498216)
KUMAR AGENCIES (BID ID -3498257)
p.chinnasamy (BID ID -3498310)
A.GOVINDARAJ (BID ID -3498467)
KSR AND COMPANY (BID ID -3499501)
eurekaenterprises (BID ID -3499990)
Neptune Engineers and Builders (BID ID -3500479)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.32 MB
BOQ_829323.xls
BOQ • 3.06 MB
8813TENDER.pdf
Tender Documents • 0.95 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .