| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.8 LAccepted-AOC 0 KALAMBAGH CHOWK MUZAFFARPUR BIHAR 842002 UDYAM BR 23 0013096 | MUZAFFARPUR | BIHAR | 842002 | ₹3.8 L | L1 | Accepted-AOC As per NIT. |
| 2 | L2₹3.9 L+₹6,998.90 (1.84%)Rejected-Finance | ₹3.9 L+₹6,998.90 (1.84%) | L2 | Rejected-Finance As per NIT. |
| 3 | L3₹4.0 L+₹14,140.62 (3.71%)Rejected-Finance | ₹4.0 L+₹14,140.62 (3.71%) | L3 | Rejected-Finance As per NIT. |
| 4 | L4₹4.1 L+₹28,424.07 (7.46%)Rejected-Finance | ₹4.1 L+₹28,424.07 (7.46%) | L4 | Rejected-Finance As per NIT. |
| 5 | L5₹4.2 L+₹41,088.73 (10.8%)Rejected-Finance F 1 1ST FLOOR EAST JYOTI NAGAR SHAHDARA DELHI DELHI 110093 | NORTH EAST | DELHI | 110093 | ₹4.2 L+₹41,088.73 (10.8%) | L5 | Rejected-Finance As per NIT. |
Tender Value
₹4.8 L
EMD Value
₹10,000
Closing Date
30 Jul 2026, 2:00 pmClosed
Sh. Sudhir Kumar
Old Zonal MCD Office, Vishal Enclave, Rajouri Garden, West Zone, Delhi -110027.
Providing and fixing of 45 Watt LED Street lights along with its allied accessories at various locations in Ward No. 103 Keshopur under West Zone.
2026_MCD_285082_9
E.E(Elect.)/WZ/2026-27/NIT No.30
Open Tender
Electrical Works
Percentage
90 days
EE/Electrical-III Division West Zone.
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
₹10,000
17 Aug 2026
23 Jul 2026
30 Jul 2026
23 Jul 2026
30 Jul 2026
23 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.001 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. | 5 | Each | 5,958 | ₹29,790 |
| 1.002 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. | 7 | metre | 313 | ₹2,191 |
| 1.003 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm | 500 | Metre | 36 | ₹18,000 |
| 1.004 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 45 Watt | 124 | Each | 1,744 | ₹2,16,256 |
| 1.005 | Supply and fixing of 32mm dia X 1 meter long G.I. Pipe (Medium Class) bracket for mounting of fluorescent/HPMV/HPSV Street Light fitting on pole including bending the pipe to the required shape , 2 nos 25mm X 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd. | 124 | Each | 982 | ₹1,21,768 |
| 1.006 | Supply of XLPE insulated PVC sheathed Al.conductor Un-Armoured Cable 1.1 KV grade conforming to IS-7098 of following Size:- 2 x 4 sqmm | 500 | Metre | 47 | ₹23,500 |
| 1.007 | S.I.T.C of Hot Press moulded SMC panel/Canopy Box of size(OD) 920 mm x 460 mm x 260 mm & (ID) 900 mm x 450 mm x250 mm , anti – corrosive, dust proof, rust proof, shock proof , Self-extinguishing property , resistant to heat , Vermin proof, Ultra Violet stabilized, Pilfer resistant, Suitable for mounting 1 no. 3 phase Starter, 1 no. 63 Amp 4 pole isolator and 1 no. 3 phase Energy meter, Socket for outgoing connection with pilferage proof SMC door duly welded with S/S handle having danger logo on its outer surface and with 1 no Hot Dip galvanized iron stand for a base of size 40 mm x 40 mm x 5 mm and height of the stand is 600 mm including 300 mm height below the ground with side strip of size 25 x 5 mm. | 5 | Each | 12,922 | ₹64,610 |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.09 MB
3009ConditionsandCircular.pdf
Tender Documents • 9.12 MB
3009GCC.pdf
Tender Documents • 1.74 MB
3009DNIT.pdf
Tender Documents • 0.76 MB
3009Schedule.pdf
Tender Documents • 1.52 MB
BOQ_332964.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .