Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.3 LAccepted-AOC A 1 BLOCK 2 HATHITHAN HATHITHAN VILLAGE TOWN JALALNAGAR CITY SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242001 INDIA | SHAHJAHANPUR | UTTAR PRADESH | 242001 | L1 | Accepted-AOC Being 1st Lowest | |
| 2 | L2₹17.9 L+₹3.2 L (21.9%)Rejected-Finance 687 ARYA NAGAR POWAYAN ROAD SHAHJAHANPUR 242001 UP | SHAHJAHANPUR | SHAHJAHANPUR | UP | 242001 | L2 | Rejected-Finance Being 2nd Lowest | |
| 3 | L3₹23.5 L+₹8.8 L (59.9%)Rejected-Finance WARD NO 11 THIRIYA NIZAWAT KHAN BAREILLY | BAREILLY | BAREILLY | L3 | Rejected-Finance Being 3rd Lowest | |
| 4 | L4₹25.3 L+₹10.6 L (72.1%)Rejected-Finance 65 MATA KA MANDIR RAM NAGAR COLONY SHAHJAHANPUR 242001 UP | SHAHJAHANPUR | SHAHJAHANPUR | UP | 242001 | L4 | Rejected-Finance Being 4th Lowest |
Tender Value
₹10.5 L
EMD Value
₹21,000
Closing Date
1 May 2024, 6:00 pmClosed
GE EAST BAREILLY
Garrison Engineer East Military Engineer Services Shahjahanpur Road Bareilly Cantt
MAINT AND REPAIR /REPLACEMENT OF REFIGERATOR, WINDOW/SPLIT TYPE AC, WATER COOLER, DESERT COOLER, VOLTAGE STABILIZER AND DEEP FREEZER AT MIL STN SHAHJAHANPUR UNDER GE (EAST) BAREILLY.
2024_MES_648020_1
8322/E8
Open Tender
Civil Works
Item Rate
245 days
BAREILLY
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE EAST BAREILLY
₹21,000
Yes
16 Jul 2024
27 Mar 2024
3 May 2024
27 Mar 2024
1 May 2024
17 Apr 2024
27 Mar 2024 - 17 Apr 2024
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level).
M&L 40mm thick PCC 1:2:4 type B1(using 20mm graded crushed stone aggregate) laid in panel, finished even and smooth with using extra cement as in flooring complete all as specified and directed.
M&L 75 mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection / foot path finishing cement concrete surface even and smooth with out using extra cement complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L for plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in surface channels and base of drains complete all as specified and directed.
Demolition of brick work in cement mortar incl all quoins, arches, pillars etc, but excluding ashler facings, dressed stonework and precast concrete articles complete all as specified and as directed.
M&L brick work with sub class B bricks burnt straight or curved on plan exc 6 M mean radius built in cement mortar 1:6 complete all as specified and as directed.
Taking down cement plaster including racking out joints hacking for key and scrubbing down with water etc complete all as specified and as directed.
M&L rendering 15mm thick in cement plaster 1:4 on surfaces fair faces of brick work and surface finished even and smooth without using extra cement complete all as specified and as directed.
M&L rendering 15mm thick in cement plaster 1:6 on surfaces other than fair faces of brick work and surface finished even and smooth without using extra cement complete all as specified and as directed.
M&L for two coats of cement base paint including preparation of new surface of wall complete all as specified and as directed.
M&L for two coats of cement base paint including preparation of old decorated surface of wall complete all as specified and as directed.
M& L for two coat of oil bound distemper including preparation of new surface of wall complete all as specified and as directed.
M& L for two coat of oil bound distemper including preparation of old treated surface of wall complete all as specified and as directed.
M&L for 1mm thick JK Wall putty on wall all as specified and directed
M&L three coat of white wash on wall including preparation of new plastered surface and complete all as specified and as directed.
M&L preparing Old plastered or unplastered surfaces of wall and applying one coat of white wash on old decorated surface of wall complete all as specfied and direcetd.
M&L preparing Old plastered or unplastered surfaces of ceiling and applying one coat of white wash on old decorated surface of ceiling complete all as specfied and direcetd.
Dismantling floor hearth or wall tilling including cement mortar bedding (but not backing ) removing serviceable tiles to store and rubbish off the premises complete all as specfied and direcetd.
M&L for 22 mm thick rubber moulded chequered cement concrete coloured tiles area of each tile exc 0.06 sqm but n.exc 0.12 Sqm , set & jointed in neat cement slurry and pointed with cement & pigment to match the shape of tiles in floors over and including 20 mm thick screed bed in CM (1:6) including dismantling of chequerred cement concrete tiles complete all as specified and as directed.
M&L in repairs for machine pressed pre-cast concrete interlocking coloured paver block, Glossy finish and shape and size conforming to IS-15658-2006 of 60 mm thickness M-35 grade with grey cement and pigment laid dry over and including 30 mm thick stone dust or sand base and compacted using vibrator complete all as specified and directed.
Demolition of stone slab and tiles of any description or thickness in floor, aprons etc complete all as specfied and direcetd.
M&L for machine cut mirror polish kota stone slab flooring20-25mm thich over 15mm thick screed bed in CM 1:6 laid and jointed with grey cement slurry mixed with pigmen to match the shad of the slab including round nosing at corners rubbing and polishing complete all as specfied and direcetd.
M&L for machine cut mirror polish kota stone slab 20-25 mm thich in riser of step,skirting,dado and pillers over and including 15mm thick rendering in CM 1:4 including rubbing and polishing complete all as specfied and direcetd.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.5 sqm each complete all as specified and directed.
S&F solid PVC door frames of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S. square tube, suppling & fixing in opening as per specification & drawing.
S&F factory made solid panel PVC door shutter 30 mm thick (Style) consisiting of frame made out of MS tubes for top & bottom rails M.S. frame shall be covered with heat moulded plain coloured PVC 'C' channel having a PVC sheet strip of 20 mm which stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rails & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement suppling & fixing in the frame at site as per specification & drawing.
S&F, 200 mm long aluminium anodised barrel tower bolts of extruded section and fixed as specified and as directed.
S&F, 100 mm long butt hinges, extruded alminium alloy with galavanised mild steel hinge pin, anodised and fixed , type C-21 complete all as specified and as directed.
S&F, 150 mm aluminium handles cast type, anodised complete all as specified and as directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 sqm but n. exc 4 sqm each complete all as specified and directed.
Taking down shutter of any description exc 1 sqm but n exc 2 sqm each complete all as specified and directed.
S & F Mild steel work as in chowkats/frame of door or gates of angle or other section with gusset plate , rail braces etc complete drilled for fixing of steel sheeting or other covering , doors etc to be prepared for hanging or sliding with and inclu either hooks and hinges or steel hanging door fittings ( exclusive of steel , sheeting or other covering , running rails and guisides ) and hanging also fastening and fixing complete
S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S & F 300 mm long mild steel sliding door bolts, ISI marked clip & bolt type, stove enamelled black, with bright bolt not less than 16mm dia with and including minimum 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and as directed.
S&F 2nd class hard wood glazed and skeleton shutters 35mm thick open rebated and prepared to receive glass , gauze etc (without sash bars) , edges of framing plain , chamfered or rounded , fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) , supplied and fitted to chowkats.
S&F 100 mm butt hinges medium weight cold rolled mild steel and fixed complete all as specified and as directed.
S&F 150 mm long mild steel pressed handles oval type stove enamlled black complete all as specified and as directed.
S&F 200 mm long mild Barrel tower bolt, oval type stove enamelled black with bright bolt and fixed complete all as specified and as directed.
M & L preparing wood or wood based surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S & F Mild steel gauzed door shutter with MS angle iron shutters frame 35 mm X 35 mm X5 mm devided with MS strip of35x5mm(01 N0) and 02 Nos of 25mmx5mm in four panel covered with galvanised mild steel wire clothes 0.63mm nominal dia of wire and average width of aperture 1.40 mm which is fixd with MS flat of 25x5 mm with nut and bolt of size 25x6mm at every 450 mm distances ,shutter with 1 Nos sliding door bolt of 16mm dia 250 mm long with locking arrangement, including MS angle iron frame 40mm x 40mm x 6mm as in chowkhat with 6 Nos hold fast of flat iron 30mm x 5mm, 200mm long with bottom flat iron of size 30mmx5mm and 100mm size 3 Nos butt hinges medium weight including necessary cutting, welding, binding as required, with two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces complete all as specified shown on drawing and as directed. (Single shutters of approx width 0.9 to 1.2M and height 1.9 to 2.1 M.)
S & F Mild steel door shutter with MS angle iron shutters frame 35 mm X 35 mm X5 mm in two panel covered with 1mm thick MS plate black sheet welded to shutters with 2 Nos sliding door bolt of 16mm dia 300 mm long with locking arrangement, including MS angle iron frame 40mm x 40mm x 5mm as in chowkhat with 6 Nos hold fast of flat iron 30mm x 5mm, 150mm long with bottom flat iron of size 30mmx5mm and 100mm size 3 Nos butt hinges medium weight including necessary cutting, welding, binding as required, with two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces complete all as specified shown on drawing and as directed. (Single shutters of approx width 0.9 to 1.2M and height 1.9 to 2.1 M.)
Taking down steel/wooden window of any size and description complete all as specified and as directed.
S&F steel windows with side hung shutters including projecting type hinges with steel handles, and steel peg stay complete without glazing bars, dovetailed or welded.complete all as specified and as directed.
S&F steel windows with side hung shutters including projecting type hinges with steel handles, and steel peg stay complete with glazing bars, dovetailed or welded.
S&F steel ventilator with top hang shutter including hinges steel pag stay,complete all as specified and as directed.
M&L framed work such as grills grating etc with end of bars shoulderd and/or riveted .welded or forged into spikes.framedguard bars iron doors.ladders framed balusters , walk ways. Railings, frame work of of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed
S&F 3 mm thick sheet glass, Ordinary quality and glazing with oil putty in square n. exc 0.5 Sqm in each pane complete all as specified and as directed.
S& F galvanised mild steel wire clothes 0.56 mm nominal dia of wire and average width of aperture1.18 mm complete all as specified and as directed .
S&F 0.80 mm thick mild steel plain black sheet in hearths, covering to door chowkhats (frames) chullah hoods, water tanks , water troughs, ducts,urinal trough and funnels etc , cut to size,edge beaded if directed, holes punched , including round headed screws,clout nails or rivets and fixed to wood or steel members, etc with plain 40 mm lap joints or welded /riveted seams including bending, turning up,mitred angles, stopped ends, outlets etc as required complete all as specified and as directed .
M&L applying 2 coats of synthetic enamel paints on new steel surfaces over a coat of red oxide primer including surface preparation over 10 cm width and girth complete all as specified and as directed .
Hacking out old broken glass of (any thickness,size,quality or description) from old wooden/steel frame ,or stones, concrete or brick surrounds glazed with putty or fixed with beads
M&L PCC 1:3:6 type C-1 using 20mm graded stone aggregate for filling in bed block of hold fast etc complete all as specified and direcetd.
S&F in repair vitreous china squatting pan of orrissa pattern long pan size 580 x 440 mm white with "P"or "S" trap size 100 mm dia front or back inlet and integral foot rest any pattern (excluding flushing cistern and flush pipe) including provn of lime concrete bedding complete all as specified. Model: cat no 20076of Hindware,or equivalent Parryware, Cera ".
S & F in Repair 10 ltrs capacity PVC valveless syphonic action type flushing cistern low level white , with inlet ball valve, float and handle including bracket and flush pipe of polyethylene of low or high density or PVC 32 mm dia for low level cistern complete all as specified and as directed.
Dismantling posts or struts (wood, steel or RCC) any section including taking out embedded portion and making good disturbed ground post embedded in concrete, brick work, masonry etc complete all as specified and as directed.
Excavation in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance n exc 50m and making good sufrace in soft/loose soil complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundation/mass concrete complete all as specified and as directed.
S&F M S Posts and struts in fencing (any size of angle) mm including cutting tops to shapes as directed including driling holes for bolting of MS flat iron in horizontal, vertical & diagnal faces of each pannel to be intertwined with Chain link fencing, and fixed to posts with MS nut bolts and washers, wind ties for sign board posts and struts, and similar work confirming to Fe 290 Gde E-165 complete all as specified and directed.
S&F mild steel screw bolts (machine made) with hexagonal or square head at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 30 cm long and dia meter of neck in mm n exc. 12mm complete all as specified and as directed.
S&F in repairs chain link M S galvanised fencing (IS-272) mesh as required but weight of mesh not exc 4.0 kg/sqm complete all as specified and directed. (Note: Weight of chain link per Sqm shall be finalised through BOO)
M&L for 10mm dia and over mild steel TMT bars, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips, complete all as specified and directed.
S&F in repairs Galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rail straining bolts including securing or tying at crossings with and provisons of galvanised mild steel wire, staples or steel pins etc as directed (each line wire to be measured) complete all as specified and directed.
M&L for preparation of roof surfaces, applying a coat of primer@ 0.40Kgs/sqm and applying a coat of bitumen grade 85/25 @1.2kg/sqm, supplying and laying water proofing treatment with using polymeric water proofing membrane (weight not less then 3kg/Sqm)3mm thick consisting of 100 micron HMHDPE film centre core including applying a coat of bitumen 85/25 grade @ 1.2kg per sqm on top surface of membrane and torch application of membrane with 10cm overlap where required and finally finished with and including a coat of aluminium paint @0.20Ltr/Sqm as per manufacture instruction over 15mm thick rendering on roof surfaces in CM 1:4 after taking down existing roof treatment complete all as specified and directed.
M&L in repairs 6mm thick Asbestos Cement, one piece plain angular ridge in roof fixed with L Type or J type or crancked hook bolt etc complete all as specified and as directed.
M&L in repairs 6mm thick Asbestos Cement, Corrugated or Semi corrugated sheets in roof, wall fixed with L Type or J type or crancked hook bolt etc complete all as specified and as directed.
S&F in repairs Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws to steel frame work, as specified.
S&F in repairs Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws to steel frame work, as specified.
S&F in repairs 75 mm dia PVC (SWR) floor trap plain with greting incl jointing with solvent cement complete all as specified and as directed.
S&F in repairs 75 mm bore PVC (SWR) pipes of single socketed in any length with rubber ring joints fixed to wall all as specified
S&F in repairs 75 mm bore PVC (SWR) bends complete all as specified and as directed.
S&F 75 mm dia stack clamps out of 50mmx5mm flat iron and 16mm dia round iron stays including bolts and nuts and securing ends of stays to ball or roof complete all as specified and as directed.
S&F 110mm bore.PVC(SWR) junction single (single T) equal or unequal with access door
S&F 110 mm PVC (SWR) bend any radius complete all as specified and as directed.
S&F in repairs 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and as directed.
S&F 100mm dia stack clamps out of 25mmx3mm flat iron with stays including bolts and nuts and securing ends of stays to wall complete all as specified and as directed
M&L for Earthing complete with using GI earth plate electrode 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness off 15 cm all around the plate with using 4 mm dia GI Wire as earth lead moulded and retreived to earth plate at one end and connected to main switch / control board at another end with and including 15 mm dia GI light grade from upper end of earth plate upto external face of the wall of the building including 20 mm dia bore GI pipe light grade as water pipe from chamber to upper edge of the plate GI funnel with wire mess fixed on water pipe and provison of PCC 1:2:4 type B-1 (Using 20 mm Dia graded stone aggregate) duly reinforced with mild steel round bar 6 mm dia @ 150 mm c/c both ways with 10 mm dia mild steel bars as in lifting handle with and including necessarry excavation and earth work including laying the pipe concealed in floor / wall allas per plate NO-3 of SSR Part-I complete all as specified and directed and testing on completiopn (Note:- If the desired resistance is not found earthing shall be done by the contractor at no extra cost to Govt).
Supply and laying in replacement of earthing strip GI 32 x 6 mm from earth test point to Electrical equipment including taking up of old UNSV earthing strip complete all as specified and directed.
Supply & Fixing in repair MCCB, 4 Pole, 160 Amps, 415 Volt, 25 kA including connecting up using suitable size of lugs complete all as specified and directed.
Supply & Fixing in repair MCCB, 4 Pole, 200 Amps, 415 Volt, 25 kA including connecting up using suitable size of lugs complete all as specified and directed.
Supply & Fixing in repair MCCB, 4 Pole, 250 Amps, 415 Volt, 25kA including connecting up using suitable size of lugs complete all as specified and directed.
Supply & Fixing in repair MCCB, 4 Pole, 400 Amps, 415 Volt, 36 kA including connecting up using suitable size of lugs complete all as specified and directed.
M&L painting to CI/MS pipes upto 18m height with two coats of synthetic enamel paint including preparation of surface on old surface.
M&L for painting to overhead tanks upto 25 m height with cement based paint includind cost for scaffolding and labour safety tools complete all as specified and directed.
Supply and fixing Glow sign board of size 2mtr x 1mtr for min 40 words of size 20 cm height and description with polycarbonate sheet suitable size including LED tube light fittings complete all as specified and directed.
S&F powder Fire extinguisher(Stored pressure type)capacity 9 kg duly ISI marked conforming to IS:15683:2006 with IS 4308,ISI marked ABC powder complete with squeeze grip release valve,discharge pipe locking arrangement,pressure gauge,operaation manual and bracket. Operating temp:-30 C to +60 C.
S&F CO2 wheeled fire extinguisher ISI marked conforming to IS:16018 Capacity 9 kg. complete with composite trolley with handle & wheel operation manual,wheel type release valve,locking arrangement and shut off valve fitted with delivery hose horn. Operating temp: -30 C to +55 C
M&L for single filling in floors or pavings,laid in layers n exc 15 cm thick,spread,levelled and blinded with earth and rammed including watering etc complete all as specified and directed
M&L for clearance of wild vegatation and grass below the transformer,panels,DG sets area and similar area and removal and refilling of shingle in the same area and spraying herbicide as specified to avoid growth of grass and vegatation
M&L for removal of rolling shutter from its opening,greasing the same,repair/replacement of spare parts ,painting and fixing in the same opening for smooth functioning of the shutter complete all as specified and directed
S&F ABC Modular Type CE certified Capacity 10 kg Fire extinguisher filled with ISI marked IS:4308 ABC powder complete all as specified and directed.
S&F in replacement taking out the old unserviceable sealed compressor unit from existing Split/window type AC 1.5 ton capacity of any make by cutting and replacing the same with new sealed unit from authorised OEM workshop/manufacturer and reconnecting the replaced sealed compressor unit to its original position of air conditioner by brazing incl flushing out complete refrigerator system by applying CTC/nitrogen gas, charging the refrigeration system with and incl compressor oil and refrigerant R-134 gas to its full capacity after complete equating and cleaning the system reinstalling the air conditioner at site and testing on false load to its satisfactor performance complete all as specified and directed.
All as per item No 94 but for capacity of air condition (2.00 ton) complete all as specified and directed.
Material and labour for detecting of leakages of gases in window type /Split Type AC unit of capacity 1.5/2 TR at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition. Note:- Refrigerant for toping up/ filling in will be measured and paid seperately under relevant items in the Schedule.
Taking down for servicing of split type AC 1.5/2 TR Capacity including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner OR cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., changing connections from heating mode to cooling mode or vice-versa and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified.
Taking down for servicing of Window type AC 1.5/2 TR Capacity including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner OR cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing connections from heating mode to cooling mode or vice-versa and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified. Notes for Ser Item No 97 & 98 :- (i) Replacement of defective spares for making the AC units in satisfactory working condition will be measured & paid separately under relevant items and Labour charges for taking out old spares & refixing of new spares shall deemed to be included in unit quoted rate.
Supply & fixing heavy duty copper pipe 6mm/12mm/15mm dia/ bore complete including insulation brazing, welding, nuts, bolts and screws of required size complete all as specified and directed.
Supply & fixing in repairs of suction and discharge valve set of size 15mm (5/8''), 6mm (1/4'') and 12mm (1/2'') for Split AC 1.5/2 TR capacity complete all as directed.
Taking down unserviceable insulation for copper pipe of any dia, supply and fixing new insulation for copper pipes suitabale for Split AC of capacity from 1.5 to 2.0 TR complete all as specified and directed.
Disconnection and removing of serviceable window type AC of capacity 1.5 TR/ 2.0TR of any make and model along with stabilizer from its position and fixing the same in other location including all other fixing accessories and testing complete all as specified and directed.
Disconnection and removing of serviceable split type AC of capacity 1.5 TR/ 2.0TR of any make and model along with stabilizer (Indoor & Outdoor Unit) from its position and fixing the same in other location including all other fixing accessories and testing complete all as specified and directed.
S&F in repairs for over load protector suitable for AC protector complete all as specified and directed.
S&F in repairs for condensor unit copper type suitable for split/window AC 1.5/2 ton capacity complete all as specified and directed.
S&F in repairs relay suitable for 1.5 Ton (window/Split type) air conditioner complete all as specified and directed.
S&F in repairs thermostat switch for AC complete all as specified and directed.
S&F in repairs switch controlling knobs along with complete control panel for any make and any size of AC complete all as specified and directed.
S&F in repairs running capacitor of required 36/45 MFD complete all as specified and directed.
S&F in repairs starting capacitor of required 120 MFD complete all as specified and directed.
M&L for repairing of voltage stablizer of any make and size of 4 KVA to 5 KVA by repairing/replacement of electric circuit and rewinding including insulating materials complete all as specified and directed.
S&F in repairs of PCB sutable size for window / split AC complete all as specified and directed by Engr In Charge.
Taking of old unserviceable/sealed compressor unit from existing refrigerator of 310/300 ltrs capacity of any make by cutting replacing the same from authorized OEM workshop and re-connecting the sealed compressor unit to its original position of refrigerator by brazing incl flushing out complete refrigeration system by applying/using Nitrogen gas, charging the refrigeration system with and incl compressor oil and refrigerant R-134A gas to its full capacity reinstalling the refrigeration machine at site testing on full for its satisfactorily performance incl painting to complete body of refrigerator with two coats of synthetic enamel paint after preparation of dents complete all as specified and directed.
All as per item No 113 for capacity of refrigerator 165/175 ltrs complete all as specified and directed.
Taking down for servicing of Refrigerator 300/310 ltrs capacity complete refrigeration system by nitrozen/CTC gas after deleting leakage and repairing tube/lines by brazing and charging the unit with compressor oil and refrigerant Gas-134 to its full capacity of refrigerator 300 lts/310 ltrs capacity of any make incl commissioning and testing for its smooth functioning complete all as specified and directed.
S&F rubber gasket of refrigerator door of any size and any make complete all as specified and directed.
Supply and replacement of thermostat switch of suitable size for any make and size of refrigerator complete all as specified and directed.
S&F in repairs for runnig capacitor of suitable size of refrigerator of any make and size complete all as specified and directed.
S&F in repairs for starting capacitor 40 MFD capacity complete all as specified and directed.
S&F in repairs for relay assembly suitable for refrigerator starting capacitor 40 MFD capacity complete all as specified and directed.
S&F in repair for over load protector suitable for refrigerator protector complete all as specified and directed.
Supply and replacement of freezer door of any make 310/300/165 ltrs size of refrigerators complete all as specified and directed.
Repair to body of refrigerator of any size/capacity by welding of MS Sheet not less than 1.6 mm thich to match existing after receiving old rusted/unserviceable portion replacement of old nut bolt washers and hinges of top cover incl painting to complete body of refrigerator with two coat of synthetic enameled paint after preparation of surface and removing dents complete all as specified and directed.
Taking of old unserviceable/sealed compressor unit from existing deepfreezer of 300/320/400 ltrs capacity of any make by cutting replacing the same from authorized OEM workshop and re-connecting the sealed compressor unit to its original position of refrigerator by brazing incl flushing out complete refrigeration system by applying/using Nitrogen gas, charging the refrigeration system with and incl compressor oil and refrigerant R-134 gas to its full capacity reinstalling the refrigeration machine at site testing on full for its satisfactorily performance incl painting to complete body of refrigerator with two coats of synthetic enamel paint after preparation of dents complete all as specified and directed.
Taking out the broken legs from the base of refrigerator supplying and fixing new legs set of 4 to put the refrigerator of any capacity/make in to vertical position complete all as specified and directed.
S&F in repairs for condensor unit suitable for deep freezer of existing size any capacity complete all as specified and directed.
M&L for repairing of voltage stablizer of any make and size of 2 KVA to 3 KVA by repairing/replacement of electric circuit and rewinding including insulating materials complete all as specified and directed.
Taking out the old unserviceble sealed compressor from existing water cooler of any capacity of any make 120/60 and 150 ltrs storage capacity by cutting, replacing the same with new compressor from nanufacturer and re-connecting the replaced sealed comressor, unit to its original position of water cooler by brazing incl flushing out complete refrigeration system by applying/using CTC Nitrogen gas, charging the refrigeration system with and incl compressor oil and refrigerant R-134 gas to its full capacity after complete evacuating and cleaning the system reinstalling the water cooler at site and testing on full for its satisfactorily performance complete all as specified and directed.
All as per item No 128 for capacity of water cooler 40/60 ltrs complete all as specified and directed.
Flushing out complete refrigeration system by CTC and repairing the leaking pipe/joints by refrigeration brazing and charging the unit with compressor oil and refrigerant gas after evacuating and flushing to its full capacity of any size and make of water cooler complete all as specified and directed.
S&F in repairs for condensor unit suitable for water cooler any capacity complete all as specified and directed.
S&F in repairs for running capacitor of suitable size of water cooler of any make and size complete all as specified and directed.
S&F in repairs for starting capacitor 80/100/120 mfd capacity complete all as specified and directed.
S&F in repairs for relay assembly 412Y/312Y complete all as specified and directed
S&F in repairs for over load protector suitable for water cooler protector complete all as specified and directed.
S&F in repairs for thermostat for water cooler complete all as specified and directed.
S&F in repairs rubber bedding gasket for any make and size of water cooler tank cover upto 25mm bore complete all as specified and directed.
Repair to body of water cooler of any size/capacity by welding of MS sheet not less than 1.6mm thick to match existing agter receiving old rusted/unserviceable portion, replacement of old nut bolt washers and hinges of top cover including painting to complete body of W/C with two coat of synthetic enameled paint after preparation of surface and removing dents complete all as specified and directed.
S&F Concussive pushbutton taps for water cooler of cast copper alloy 15mm, screwed for iron pipe and fixed complete all as specified and directed.
S&F in Replacement of PVC copper cable 2.5 sqmm multistrand three core complete all as specified and directed.
M&L for repairing of voltage stabilizer of any make and size of 0.5 KVA to 1 KVA by repairing/replacement of electric circuit and re-winding including insulating materials complete all as specified and directed.
Supply and Fixing Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed.
Material and labour for two single core PVC Insulated unsheathed multi stranded FRLS copper conductor cable of size 4 sqmm as sub main wiring including suitable size heavy duty rigid PVC conduit and of PVC insulated unsheathed multi stranded FRLS copper conductor cable of size 4 sqmm as an earth continuity conductor complete all as specified.
Material and labour for two single core PVC Insulated unsheathed multi stranded FRLS copper conductor cable of size 2.5 sqmm as sub main wiring including suitable size heavy duty rigid PVC conduit and of PVC insulated unsheathed multi stranded FRLS copper conductor cable of size 2.5 sqmm as an earth continuity conductor complete all as specified.
M&L for complete overhauling of desert cooler of any size and make including replacement of perished wiring oiling and greasing the blower motor exhaust fan and water lifting/tullu pump including replacement of plastic unserviceable spares susch as ben, water distributor and PVC pipe including replacement of wood pads, preventing leakage if any by welding, painting of water tank with rubber seal of any approved make and testing the same for its smooth functioning complete all as specified and directed.
M&L for Desert cooler fan/ exhaust fans any type 230 V, AC sup, Single phase dismantling the cooler fan/ exhaust fans and taking out complete burnt winding from cooler fan motor and rewinding the same with super enameled copper winding wire of existing gauge and size incl throughly cleaning all the components of cooler fan, oiling and greasing painting with one coat of synthetic enamel paint after scrubbing and preparing the old painted surfaces & testing etc complete all as specified and directed.
M&L for two coats of painting for desert cooler cover a coat of red oxide primer including preparation of old surfaces on complete body of desert cooler of existing colour after removing dents and preparing surface complete all as specified and directed.
supply and fixing in repairs front grill of desert cooler of approved make complete with 5 Amp switch , three speed regulator including lamp complete all as specified and directed.
S & F in repairs 3 pin plug top 5 amp, 230V for desert cooler complete all as specified and directed.
S&F in replacement of water submersible pump 40 watt (2.65 mtr water lifting) water pump for desert cooler (1.5 mtr power cord) type complete all as specified and directed.
S&F in replacement of wood wool for desert cooler of any size complete all as specified and directed.
Supply and filling refrigerant gas R-22/R-410A/R-32/R-134A in window type /Split Type AC unit of capacity 1.5/2 TR, Deep Freezer, Refrigerator, Water Cooler of any capacity complete all as specified and as directed.
Supply and Fixing Heating element of capacity 1.50 KW any type, ISI marked, suitable for geyser of capacity 25/50 Ltr complete all as specified and directed.
Supply and fixing capacitor Dry type 2.5 MFD 230 volts for Ceiling fan of any type complete all as specified and directed.
Supply and fixing capacitor Dry type 4 MFD 230 volts for Exhaust/cooler fan of any type complete all as specified and directed.
Supply and Fixing of fan blade for Desert cooler of any type and any size complete all as specified and directed.
Supply and Fixing of fan blade for AC of any type and any size complete all as specified and directed.
Supply and Fixing of fan blade for water cooler of any type and any size complete all as specified and directed.
Supply and Fixing of fan blade for deep freezer of any type and any size complete all as specified and directed.
M/S MANSI TRADERS
N S ELECTRICALS
M/S CHAUHAN ELECTRIC WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .