Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.5 LAccepted-AOC OPPOSITE J K BANK BAROO NH1 HAIDERY COMPLEX BAROO KARGIL BAROO KARGIL LADAKH 194103 | KARGIL | LADAKH | 194103 | L1 | Accepted-AOC Lowest rate quoted | |
| 2 | L2₹30.8 L+₹4.5 L (17.0%)Rejected-AOC | L2 | Rejected-AOC Higher rate quoted than L1 | |
| 3 | L3₹31.0 L+₹4.7 L (17.9%)Rejected-AOC | L3 | Rejected-AOC Higher rate quoted than L1 | |
| 4 | L4₹33.3 L+₹7.0 L (26.6%)Rejected-AOC | L4 | Rejected-AOC Higher rate quoted than L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
23 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DIST-BURDWAN, WEST BENGAL, PIN-713420
All as per BOQ
2023_MES_583918_1
8400-916/E8
Open Tender
Electrical and Maintenance Works
Works
180 days
PANAGARH
Class D and Category b (i) (Low Tension Electric Works (Upto 1100 Volts))
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹90,000
Yes
6 Apr 2023
2 Mar 2023
24 Mar 2023
2 Mar 2023
23 Mar 2023
9 Mar 2023
Amount
Taking down carefully aluminium conductor point wiring (light,fan,socket or power) complete including fittings such as switches,ceiling roses, pendants, regulators ,sockets etc. and removing (except those to be reused shall be kept in safe custody at the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as specified and directed.
M&L for point wiring for light point/ fan point, one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLSHH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes 3 mm thick bakelite sunmica sheet cover (ISI Marked) fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLSHH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
All as per item No 2.00 mentioned here-in-above but 5 Amp socket on same board with other switches complete all as specified and directed.
All as per item No 2.00 mentioned here-in-above but 5 Amp socket on Independent board with other switches complete all as specified and directed.
All as per item No 2.00 mentioned here-in-above but one bell point with other switches complete all as specified and directed.
All as per item No 2.00 mentioned here-in-above but for one light point controlled by two -2 way switches complete all as specified and directed.
M&L for wiring for socket outlet 3 pin, 15 amps on independent Boards controlled by one, one way switch using 4.0 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes/ modular , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 4.0 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLSH cable earth wire and connecting to earth dolly complete all as specified and directed. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
M&L for point wiring for light point/ fan point one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLSH cables in and including suitable size PVC casing and caping/PVC conduit above 20mm (ISI marked), including pressed steel terminal box or PVC terminal sutable for modular, top cover (ISI Marked) 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc complete all as specified and directed. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
All as per item No 8.00 mentioned here-in-above but 5 Amp socket on same board with other switches complete all as specified and directed.
All as per item No 8.00 mentioned here-in-above but 5 Amp socket on Independent board with other switches complete all as specified and directed.
All as per item No 8.00 mentioned here-in-above above but one bell point with other switches complete all as specified and directed.
All as per item No 8.00 mentioned here-in-above but for one light point controlled by two 2 way switches complete all as specified and directed.
M&L for point wiring for light point/ fan point one light/fan/exhaust fan point controlled by one, one way switch using 4.0 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLSH cables in and including suitable size PVC casing and caping (ISI marked), 4.0 sqmm nominal cross sectional area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly complete all as specified and directed. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
S&F switch piano flush type, single pole , 5/6 Amps, one way complete all as specified and directed. (Make: Anchor/Penta/Havells/Gold Medal)
S&F socket outlet 2 in 1 multipurpose 5 pin , (6 Amps ) flush type controlled by one switch duly marked complete all as specified and directed. (Make: Anchor/Penta/Havells/Gold Medal)
S&F switch 16 Amps, 230/240 V complete all as specified and directed. (Make: Anchor/Penta/Havells/Gold Medal)
S&F socket outlet 2 in 1 , 6 pin , (16 Amps ) flush type controlled by one switch complete all as specified and directed. (Make: Anchor/Penta/Havells/Gold Medal)
S&F ceiling rose surface bakelite 45 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified and directed. (Make: Anchor/Penta/Havells/Gold Medal)
S&F stepped type electronic fan regulator flush type 240 Volts ISI marked complete all as specified and directed (Make: Anchor/Penta/Havells/Gold Medal)
S&F Bell push , flush type , 5 amp duly marked complete all as specified and directed. (Make: Anchor/Penta/Havells/Gold Medal)
S&F Ding dong, AC 230 Volts, single pole 230 volts all as specified and directed. (Make : Anchor/Penta/Havells/Gold Medal)
S&F lamp holder with 15 Watt LED lamp inverter type with 4 hour backup, polycarbonate body with back plate straight or angular suitable for batten fittings complete all as specified and directed. (Make : Anchor/Penta/Havells/Gold Medal)
S&F switch modular type 6 Amp one way, one module, single phase, complete all as specified and directed by Engineer-in-charge (Make: Anchor (Wood)/ABB/Legrand)
S&F switch modular type 16/20 Amp one way, one module, single phase, complete all as specified and directed by Engineer-in-charge. (Make: Anchor (Wood)/ABB/Legrand).
S&F bell push ,modular type 6 Amp SP one way, 1 module complete all as specified and directed. (Make: Anchor (Wood)/ABB/Legrand)
S&F fan regulator modular step type 120 W 2 module suitable for 230 volt AC complete all as specified and directed. (Make: Anchor (Wood)/ABB/Legrand)
S&F socket outlet modular type 6 Amp 2/3 pin , two module, single phase, complete all as specified and directed by Engineer-in-charge. (Make: Anchor (Wood)/ABB/Legrand).
S&F socket outlet modular type 16 Amp 2/3 pin , two module, single phase, complete all as specified and directed by Engineer-in-charge. (Make: Anchor (Wood)/ABB/Legrand).
S&F decorative front plate white coloured for 8 modules complete all as derected by Engineer-in-charge (Make: Anchor (Wood)/ABB/Legrand)
All as per item No 29.00 mentioned here-in-above but 6 module complete all as specified and directed
All as per item No 29.00 mentioned here-in-above but 4 module complete all as specified and directed
All as per item No 29.00 mentioned here-in-above but3 module complete all as specified and directed
All as per item No 29.00 mentioned here-in-above but1/2 Module complete all as specified and directed
S&F blanking plates white coloured for 1 modules complete all as specified and directed
S&F metal terminal boxes fixed flush in position with cement mortar (1:4) complete all as specified, suitable for 1/2 modules complete all as specified and directed (Make: Anchor,ABB,Legrand).
All as per item No 35.00 mentioned here-in-above but for 3 module complete all as specified and directed.
All as per item No 35.00 mentioned here-in-above but for 4 module complete all as specified and directed.
All as per item No 35.00 mentioned here-in-above but for 6 module complete all as specified and directed.
S&F sheet metal enclosure with 20 Amp Mcb and two pin and earth plug and socket complete with one single pole MCB complete all as specified and directed (Make : Anchor/Havells/ABB).
S&F submain two single core, 4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC conduit (ISI marked), concealed, including 4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface. Three runs cable and PVCconduit pipe will be measured and as single unit.).
S&F submain two single core ,6 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade drawing in and including nd including suitable size PVC conduit (ISI marked), concealed, including 6 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface. Three runs cable and PVC conduit pipe will be measured and as single unit.).
S&F submain two single core, 4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC casing and caping/PVC conduit pipe above 20mm (ISI marked) including 4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface. Three runs cable and PVC conduit pipe will be measured and as single unit.).
S&F submain two single core ,6 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade drawing in and including nd including suitable size PVC casing and caping (ISI marked) including 6 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface. Three runs cable and PVC conduit pipe will be measured and as single unit.).
S&F wall security light fittings 35 watts 230v, minimumm lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65/66 including necessary connection complete with 25mm GI pipe with suitable clamp, nut, bolts etc all accessories including connected with 3 core copper cable of suitable 1.5 sqmm size complete all as specified and directed. (Make : Mazic/Phillips/Wipro)
S&F modular type 25 Amps power unit combine with ON/OFF switch enclosure single pole and neutral with two pin and earth socket complete all as specified and directed (Make : Bajaj/Crompton/Phillips/Havells) (Note: Including suitable terminal box modular covery plate etc)
S&F wall mounted adjustable angle LED focus/spot light 6/9 watt indoor luminaries with and including Electronic driver and LED lamp, pre-wired including necessary electric connection from ceiling rose to light fitting, conforming to the following specifications :- (for focusing on the portait/photos, Name plates, Inogration Bords etc) (i) System Watts/Lumens : Max 9W/Total system lumen not less than 1260 Lm. (ii) Housing - Extruded polycarbonate. (iii) IP rating IP 20 (iv) Front cover -Acrylic/Polycarbonate cover. (v) Colour temperature not less than 5700 K (vi) Colour rendering index (CRI) - Not less then 80. (vii) Optics - Designed for optmum light distribution. (viii) Control gear - Inbuilt electronic driver with APFC, PF no less than 0.95, and THD not more than 20% of the stander operating voltage 180-270 V Ac, 50 Hz. (Make : Philips/Havells/Juquar/CG/Bajaj)
S&F in repair 01 x 18 Watt LED batten light fittings, with T-8 tube, rode, lighting fixture with extruded polycarbonate complete with all accessories and connection from ceiling rose with twin core twisted flexible copper conductor cable with suitable size and earthing complete all as specified and directed. (Make: Bajaj/Crompton/Phillips/Havells).
S&F round shape 6 watt 220 volts AC reccessed type with high effiency PMMA diffuser soft glare free light complete with driver ,holder & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engr-in-Charge (Make: Bajaj/Havells/Phillips/CG).
S&F LED luminaire 600x600mm 40 watt 220volt AC reccessed type with high effiency PMMA diffuser soft glare free light complete with driver ,holder & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engr-in-Charge (Make: Bajaj/Havells/Phillips/CG).
S&F LED luminaire 600x600mm 35/36 watt 220volt AC reccessed type with warm white colour high effiency PMMA diffuser soft glare free light complete with driver ,holder & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engr-in-Charge (Make: Bajaj/Havells/Phillips/CG).
S&F sheet metal enclosure of size 3' x 2' x 200mm with locking arrangement made with 2mm thick poweder coated CRC sheet and provn of 04 Nos glass 75mm x 150mm size in front door for measuring meter reading flush to wall for fixing of 04 Nos energy meter including taking down carefully energy meter including connection complete all as specified and directed.
S&F in repairs epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 12 ways with mounting fitted with bus bar, DIN hannel , neutral link and incoming contact complete all as specified and directed. (Note: All wire connection with suitable size copper lugs) (Make :Havells/ABB/Legrand).
S&F in repairs epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Tripple pole and neutral 240 V, 4 ways with 160 amp MCCB copper bus bar chamber etc mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed. (Note: All wire connection with suitable size copper lugs) (Make :Havells/ABB/Legrand).
S&F in repairs epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed. (Note: All wire connection with suitable size copper lugs) (Make : Havells/ABB/Legrand).
S&F in repairs epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), V/TPN 240 V, 12 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact with suitable size 125 amp MCCB complete all as specified and directed (Make :Havells/ABB/Legrand).
M&L for checking of ceiling fans upto 1400mm, after taking down the fan carefully and removing from site to workshop including, split pin and jam nut, rewinding of fan coil with super quality, super enameled copper wire of suitable gauge and heat vernishing and refixing the same in original positionincluding greasing of bearings and other moving parts and replacement of split pin, jam nut & rubber brush and testing complete all as specified and directed.
S&F in repairs MCB SPN 40 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating) (Make :Havells/ABB/Legrand).
S&F 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning (Make :Havells/ABB/Legrand).
S&F in repairs MCB TPN 63 Amps, 'C' series 10kA, 415 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating). (Make :Make :Havells,ABB,legrand).
S&F in repairs MCB TPN 80 Amps, 'C' series 10kA, 415 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating). (Make :Havells/ABB/Legrand).
S&F MCCB 4 pole, 3 phase, 415 volt of capacity 63 Amp, 16 KA complete with proper copper thimbles, copper reducer etc all as directed. Make :Havells,ABB,legrand.
S&F MCCB 4 pole, 3 phase, 415 volt of capacity 125 Amp, 16 KA complete with proper copper thimbles, copper reducer etc all as directed Make :Havells,ABB,legrand.
M&L for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth wire electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth wire encased in and including 15 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments, 20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. (Note :- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) Testing to be carried out by the contractor in presence of Engr- in- Charge , entered in the eath testing register, prepared and to be maintained by the contractor & submited to Concerned JE E/M. (iii) T&P and testing instrument(Meger) to be provided by the contractor at own cost).
S&F in repair steel body Exhaust ventilation fan of sweep 300mm 230V, 1400 RPM after taking out the existing burnt out fan complete all as specified and directed by Engr-in-Charge. (Make : Havells/Bajaj/Crompton).
S&F in repair steel body Exhaust ventilation fan of sweep 380mm 230V, 1400 RPM after taking out the existing burnt out fan complete all as specified and directed by Engr-in-Charge. (Make : Havells/Bajaj/Crompton).
Repair replacement of upto 300 mm Exhaust Fan Motor, 240 V, Speed: 1440 Rpm with copper rewinding complete all as specified and directed Engr-in-Charge (Make : Havells/Bajaj/Crompton).
Repair replacement of Three Phase Mild Steel Electric Heavy Duty Exhaust 450 mm Fan with copper rewinding Motor 50 Hz Frequency Speed Upto 1400 RPM Material Mild Steel complete all as specified and directed Engr-in-Charge (Make : Bajaj/Havells/CG)
Dismantling old unservicable under ground cable of any size any make complete all as specified and directed Engr-in-Charge.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10sqmmx2core laying properly in treanche complete all as specified and directed E-in-charge. (Make: Havells,Polycab,KEI).
M&L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16sqmmx2core laying properly in treanche complete all as specified and directed E-in-charge (Make: Havells,Polycab,KEI).
M&L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25sqmm x 4 core laying properly in treanche complete all as specified and directed E-in-charge (Make: Havells,Polycab,KEI).
Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling, including spreading, leveling, watering and well ramming in layers not exc. 25cmin soft/loose soil complete all as specified and directed.
Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and directed. (Note : Punned thickness shall be measured).
M&L for sub class B bricks locally available of size 25 x 12.5 x 7.5 cm laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and directed
M&L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35sqmm x 4 core laying properly in treanche complete all as specified and directed E-in-charge (Make: Havells,Polycab,KEI). (Note : Excavation, removing, sand cunning, brick laying paid in respective item separately)
ANSH CONSTRUCTION
R. D. Industrial
CHANDRA CONSTRUCTION AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .