| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.6 LAccepted-AOC | L1 | Accepted-AOC Accepting being lowest | |
| 2 | L2₹5.0 L+₹1.1 L (28.2%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than lowest | |
| 3 | L3₹5.5 L+₹1.6 L (40.2%)Rejected-Finance | L3 | Rejected-Finance Rejected being other than lowest |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
17 Mar 2022, 6:00 pmClosed
Shri Prakash G Kalekar AE QS and C
Military Engineer Services, Garrison Engineer (South) Ahmednagar - 414002
REPAIR/REPLACEMENT OF COOLING APPLIANCES AND DG SETS AT MIL STN BHUSAWAL UNDER GE (S) AHMEDNAGAR
2022_MES_509095_1
8867/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
Bhusawal
Class E Cat b (i)
8 documents required · 8 mandatory
₹300
Garrison Engineer (South) Ahmednagar
₹10,000
Yes
22 Mar 2022
18 Feb 2022
19 Mar 2022
18 Feb 2022
17 Mar 2022
2 Mar 2022
18 Feb 2022 - 23 Feb 2022
Amount
Taking down from site or from E/M store yard, PVC/MS desert cooler of any size and make from bracket/ stand, spanning all three side shutters and taking out old wooden chips pad, cleaning outer and inner surface by rubbing with sand paper or wire brush, taking down of fan motor, submersible pump, diverter, fan blade, water pipe, water pump, condenser, side panels, scrapping of rusted inside of tank & body, painting of all dismantled items inside with one coat of red oxide metal primer and two coat of synthetic enamel paint of approved quality, re-assembling of wood wool with wire mesh, complete wiring and testing including re-fixing properly at the same place as required at site all as specified and directed. Note : Spares shall be measured and paid for separately.
M&L for transporting from site or from E/M store yard to local workshop and back, opening, cutting and taking out complete copper winding, cleaning with kerosene oil/ diesel/ turpentine oil and dried out, rewinding with new super enamelled copper wire of suitable size and gauge and number of turns as recommended by the respective manufacturers, varnishing and heating the winding including providing paper insulation (Cut/strip type) replacing unserviceable/ missing spare (bush, earthing, screw , upper , socket, CI block, quater /split pin (top & bottom), lock nut etc) fixing the stator in rotor properly aligned and resembling ensuring speedy and noiseless running and depositing in E/M yard or fixing at site in position complete all as specified and as directed. Note : Capacitor & bearing shall be measured and paid for separately as supply only.
S&F fan motor with double speed copper winding, 1400 RPM, single phase, 450mm sweep with MS frame and MS fan blade including bracket, nut, bolt , washer etc for desert cooler confirming to relevant IS all as specified and as directed. Make: Maxwell/ AUE/ Usha/ Kaitan/ ACW
S&F best quality of wood wool, suitable for desert coolers all as specified and as directed.
S&F PVC pipe 1/2" dia H/D for desert cooler for internal connection all as specified and as directed.
S&F GI wire mesh, 15 mm x 15 mm appreature of suitable gauge for desert cooler for fixing of wood wool as specified and as directed.
S&F condenser, 4 Mfd, 230 Volts, AC all as specified and as directed.
S&F water circulating pump motor, 1/26 HP (Tullu pump), 230 V, single phase, 1440 RPM, suitable for any type of air cooler/desert cooler fixed complete all as specified and as directed.
S&F in repairs, galvanised iron Air Diverter grill, 20" size for desert coolers, all as specified and as directed.
M&L in repairs, flexible cord, PVC insulated and sheathed, 3 core, flexible with copper conductor of size 2.5 sqmm all as specified and as directed.
S&F in repairs, heavy duty air cooler MS stand with trolly (Size 60cmx60cm) and minimum height 75cm complete all as specified and as directed.
S&F in repairs, motor bearing for desert cooler all as specified and as directed.
Maintenance and servicing of diesel engine driven generating set of capacitiy 200 KVA, 415 Volt- 01 No installed at Pump house No 2 by carrying out first hand repairs, cleaning of engine, cleaning of fuel tank, cleaning of duct, alternator , all type of filters etc from time to time complete and keeping DG set fully serviceable condition all as specified and as directed . Note : Spare parts will be measured and paid separately under relevant items.
Maintenance and servicing of diesel engine driven generating set of capacitiy 25 KVA, 415 Volt- 01 No installed at Sub Stn No 1 by carrying out first hand repairs, cleaning of engine, cleaning of fuel tank, alternator, all type of filters etc for time to time complete and keeping DG set fully serviceable condition all as specified and as directed. Note : Spare part, coolant and distilled water will be measured and paid separately under relevant items.
M&L for lubricant oil for DG set 25 KVA & 200 KVA complete all as specified and as directed.
M&L for radiator coolant concentrate for 200 KVA and 25 KVA DG Sets filled complete all as specified and as directed. Make:- K- COOL SUPER PLUS/ CASTROL
S& F in repairs, pre-oil filter assembly complete set with all fixing arrangement for 25 KVA DG set all as specified and directed. Make : Kirloskar
Radiator servicing (Separate) of 200 KVA DG set including dismantling from chasis and refixing after complete servicing of radiator all as specified and as directed.
S&F in repairs, fuel filter element for 25 KVA DG set all as specified and as directed.
S&F in repairs, diesel filter of 200 KVA DG set all as specified and as directed.
S&F in repairs, diesel filter of 25 KVA DG set all as specified and as directed.
S&F in repairs, engine oil filter of 200 KVA DG set all as specified and as directed.
S&F in repairs, engine oil filter of 25 KVA DG set all as specified and as directed.
S&F in repairs, flexible fuel pipe of suitable size with banzo washers for 25 KVA DG set all as specified and as directed.
S&F in repairs, flexible fuel pipe (from feed pump to fuel filter, fuel filter to fuel pump and pre-filter to tank unit) of suitable size with banzo washers for 200 KVA DG set all as specified and as directed.
S&F in repairs, 'V' belt for dynamo/ alternator of suitable sizes of DG Set 200 KVA all as specified and as directed. Make : Greaves
S&F in repairs, 'V' belt for dynamo/ alternator of suitable sizes of DG Set 25 KVA all as specified and as directed. Make : : Kirloskar
S&F in repairs, rubber hose pipe with clamp for 200 KVA DG Set all as specified and as directed.
S&F in repairs, rubber hose pipe with clamp for 25 KVA DG Set all as specidied and as directed.
S&F in repairs, air filter (outer & inner) complete of suitable size for 200 KVA DG Set all as specified and as directed.
S&F in repairs, air filter (outer & inner) complete of suitable size for 25 KVA DG Set all as specified and as directed.
S&F in repairs, 12 Volt, 88 AH, maintanance free battery for 25 KVA DG all as specified and as directed
S&F in repairs, 12 Volt, 180 AH, maintanance free battery for 25 KVA DG all as specified and as directed.
S&F in repairs, ignition/starter switch with key set for 200 DG set complete all as specified and as directed.
S&F in repairs, water temparatur gauge meter for 200 KVA DG set all as specified and as directed.
S&F in repairs, oil pressure gauge for 200 KVA DG set all as specified and as directed.
S&F in repairs, oil pressure gauge for 25 KVA DG set complete all as specified and as directed.
S&F in repairs, auto control wiring with PVC insulated copper wire multistranded of suitable size for 200 KVA DG set with all accessories all as specfied and as directed.
S&F in repairs, auto control wiring with PVC insulated copper wire multistranded of suitable size for 25 KVA DG set with all accessories all as specfied and as directed.
S&F in repairs, DOL starter (Control panel complete set) including ON/OFF button, ISI marked for 2HP submersible pump, single phase, 200-230 V complete all as specified and as directed.
S&F in repairs, insulation of duct tar sheet for 25 KVA DG set complete all as specified and as directed.
S&F in repairs, normal spare parts i.e washer, spring, O-Ring, bushes, disc plug, piston ring etc for 25 KVA DG set as required at the time of maintenance all as specified and as directed.
S&F in repairs, normal spare parts i.e washer, spring, O-Ring, bushes, disc plug, piston ring etc for 200 KVA DG set as required at the time of maintenance all as specified and as directed.
S&F in repairs, starting capacitor of capacity 80/100 mfd, 440 volt AC suitable for window type air conditioner 1.5 ton capacity complete all as specified and as directed. Make : TESLA EPCOS, siemens, Shriram.
S&F in repairs, running capacitor of capacity 36/50 mfd, 440 volt AC suitable for window type air conditioner 1. 5 ton capacity complete all as specified and as directed. Make : TESLA EPCOS, siemens, Shriram.
S&F in repairs, blower with condenser fan complete, 230V, AC 50, Hz, single phase of Window AC of any capacity complete all as specified and as directed..
Disconnecting, cutting and taking out unserviceable sealed unit compressor of Window type AC conditioner 1.5/2 Ton capacity, any make and model and supply and fixing new compressor of same make as existing for Window type air conditioner 1.5/2 ton capacity, soldering, welding , brazing as required and making electric & machanical connections of air conditioner at site and testing on full load complete all as specified and as directed.
S&F in repairs, oscillating motor for indoor unit of Split AC, 1.5 Ton/2.0Ton capacity , suitable for LG,as Samsung, Voltas, Blue Star /Shriram usha make all as specified and directed.
Disconnecting, cutting and taking out unserviceable condenser coil of Window type AC conditioner, 1.5/2 Ton capacity any make and model and supply and fixing new copper condenser of same make as existing for Window type air conditioner 1.5/2 ton capacity, soldering, welding , brazing as required and making electric & machanical connections of air conditioner at site and testing on full load complete all as specified and as directed.
Disconnecting, cutting and taking out unserviceable sealed unit compressor of split type AC conditioner 1.5 Ton capacity any make and model and supply and fixing new rotary type compressor of same make as existing for split type air conditioner 1.5 ton capacity, soldering, welding , brazing as required and making electric & machanical connections of air conditioner at site and testing on full load complete all as specified and as directed. Make : Hitachi/Voltas/Videocon or equivalent as approved from list of makes specified in the tender documents.
Disconnecting, cutting and taking out unserviceable condenser unit of split type AC conditioner 1.5 Ton capacity, any make and model and supply and fixing new copper condenser complete of same make as existing for split type air conditioner 1.5 ton capacity soldering, welding , brazing as required and making electric & machanical connections of air conditioner at site and testing on full load complete all as specified and as directed. Make : Hitachi/Voltas/Videocon or equivalent as approved from list of makes specified in the tender documents.
S&F in repairs, fan motor for indoor unit of Split AC, Capacity 1.5 Ton, suitable for LG, Samsang, Voltas, Shriram usha make, complete all as specified and as directed.
S&F in repairs, capacitor of 1.5 Ton Split AC for LG, Sumsang, Voltas make all specified and as directed.
S&F in repairs, evaporator coil assembly for indoor unit of 1.5 ton split AC, all as specified and directed. Make: Videocon, Hitachi, Sumsung
S&F in repairs, AC fan blade and swing blades motor of suitable size for ourdoor unit of Split AC complete all as specified and as directed.
M&L in repairs, flexible cord, PVC insulated and sheathed, 650/1100 V wire, 3 core, 4 sqmm copper conductor, all as specified and as directed.
S&F in repairs, control PCB circuit plate with display PCB (main board) for split AC, 1.5 ton capacity complete all as specified and as directed. Make- LG / Samsung/ Videocon
S&F in repairs, AC blower with fan motor for indoor unit of Split AC, capacity 1.5 Ton, suitable for Hitachi/ Voltas/ micromax make all as spd and as directed.
Disconnecting water cooler, any size from main power and taking out for servicing/maintanace and checking serviceability of compressors, fan motor, capacitor, thermostate switches, gas leakage, push taps, fan blades, relays, over load protectors, condensor coil and any other spares required to make the water cooler functional and fixing in original /existing position complete all as specified and as directed. Note : Spare parts to be replaced shall be measured and paid for separately under respective item.
Disconnecting, cutting and taking out unserviceable sealed unit compressor of water cooler, storage type 40-80 ltrs capacity, any make & model and supply and fixing new sealed compressor of same make for water cooler storage type, 40-80 ltrs capacity, soldering, welding, brazing as required, making electric & mechanical connections and water connection, installation of water cooler at site and testing on load complete all as specified and as directed.
Repair/maintenance of water cooler, 40/60/80 ltrs capacity, dismantling required parts for general cleaning, scraping with emery/sand paper filling of putty wherever required and painting with one coat of red oxide primer and two coat of synthetic enamelled paint of approved colour complete all as specified and as directed.
S&F in repairs, fan blade, made out of aluminium, suitable for water cooler 40/60/80/120 ltrs capacity all as specified and as directed.
S&F in repairs, thermostat, suitable for water cooler of capacity 40/60/80 ltrs all as specified and as directed.
S&F in repairs, fan motor, 1/35 HP, 230 Volts, single phase, 1440 RPM suitable for water cooler all as specified and as directed.
S&F in repairs, running capacitor, 10 mfd, suitable for water cooler all as specified and as directed.
M&L for charging gas R22/R-34 for water cooler/refrigerator/AC top up including testing complete all as specified and as directed.
Repairs/servicing of refrigerator, 165/310 lts capacity, including taking down of unserviceable parts such as cooling coil, freezer chest and other parts, cleaning internally and externally complete including S&F in repairs/replacement of unserviceable parts such as capillary, stainer, theromstat, relay and other parts etc all as specified and as directed.
Disconnecting, cutting and taking out unserviceable sealed unit compressor of refrigerator upto 310 ltr capacity, any make and model and supply and fixing new company make sealed compressor including soldering, welding, brazing as required and making electric & mechanical connections at site and testing on load complete all as specified and as directed.
Disconnecting, cutting and taking out unserviceable condenser of refrigerator upto 310 ltr capacity, any make amd model and supply and fixing new copper condenser, making electric & mechanical connections at site and testing on load complete all as specified and as directed.
S&F in repairs, following items for Kent RO, capacity of 25 ltrs/hrs complete all as specified and as directed :- (a) Sediment filters -03 Nos (b) Carbon filter - 01 No (c) RO membrane-01 (d) Post carbon filter-01 (e) UF hollow fibre -01 No
S&F in repairs, adaptor for Kent RO, capacity of 25 ltrs /hrs complete all as specified and as directed.
S&F in repairs, booster pumps for Kent RO, capacity of 25 ltrs/hrs complete all as specified and as directed.
M&L for repair of mini central AC system with the following parts replacement including cleaning:- (a) Water storage body cleaning. (b) Remove and refixing of woodwool of AC system body. (c) Copper winding of existing submersible motor 2 HP, single phase, 230 V and lifting head 2.5 mtr. (d) Repair of existing water storage body complete including applying one coat of red oxide primer and two coats of synthetic enamel paint. (e) Existing duct sheet to be extended upto 12 mtr with existing same size of duct incl 03 Nos air opening outlet size of 0.60x0.45m complete all as specified and directed.
Repairs/maintenance of deep freezer, 300 lts capacity, including taking down unserviceable parts such as cooling coil, freezer chest and other parts, cleaning internally and externally complete replacement of unserviceable parts such as capillary, stainer, theromstat, relay complete all as specified and as directed.
Disconnecting, cutting and taking out unserviceable sealed unit compressor of deep freezer upto 310 ltr capacity, any make and model and supply and fixing new sealed compressor, soldering, welding, brazing as required including gas charging in the compressor, making electric & mechanical connections at site and testing on load complete all as specified and as directed.
S&F in repairs, thermoste with relay suitable for 300 ltrs deep freezer complete all as specified and as directed.
CHAUDHARY AND ASSOCIATES
Bhirud Electric Stores
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .