Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
10 Oct 2022, 10:30 amClosed
Commandant ARC and MC
Commandant Assam Rifles Constr and Maint Coy Laitkor Shillong
Maint of DG sets, transformer, pumps at Dwarka and LOAR, New Delhi
2022_ARMHA_716239_1
ENG/III-235/2022-23/63 dated 04 Oct 2022
Open Tender
Civil Works
Works
240 days
LOAR New Delhi
As per tender documents
2 documents required · 2 mandatory
₹500
Yes
Commandant ARC and MC
₹30,000
Yes
2 Nov 2022
4 Oct 2022
11 Oct 2022
4 Oct 2022
10 Oct 2022
4 Oct 2022
4 Oct 2022 - 10 Oct 2022
SF ACCN DWARKA, NEW DELHI M & L maintenance and servicing of 250 KVA DG set (Make-Cummins) complete including draining out of diesel, draining out engine oil from the sump, flushing the sump and cleaning, replacement of gaskets, fuel filters, oil filters, air cleaner elements and the worn out parts like fuel flexible pipes, nuts, bolts, fuel line etc . filling the starting batteries with electrolyte, applying petroleum jelly in battery terminals poles, checking of voltage, amps, fuel, coolant and exhaust leakages etc tightening all the nuts and bolts to the required torque incl testing in all respect as per directed by Engr-In-Charge.
M&L for servicing to Diesel Engine 125 KVA, 6 cylinder, 1500 RPM prime mover directly coupled with 50 HP Jokey pump for fire fighting services installed at SF accn including dismantling components cleaning ,servicing replacing fuel filters ,lube oil filters of recommended grade including checking servicing of Fuel injection pump etc re assembling all the components to its original position and servicing & maint of Jokey pump with testing and commissioning to entire satisfaction of Engr-in-Charge
Maint & servicing of 750 KVA dry power distribution transformer, 11/0.433 KV indoor type including taking out the top cover assembly with gaskets and inspect/ technical checking the windings, loose connections, condition of tap changers, gas level upto required mark terminal boards and cleaning the all dust, dirt or residues on windings or insulators through air compressor / vacuum cleaner. Cleaning the lead supports, tap changers and terminal boards through brushes/wiped with dry lint-free cloth. Technically checking the all HT & LT bushes, loose connection, replace the bushing with nuts and bolts if required. Checking the HT & LT cable jointing kit, replace the same if required. Charging of transformer and testing to entire satisfaction in all as directed by Engr In Charge.
M&L for servicing to VCB 11KV installed SF6 breaker dismantling components cleaning ,servicing and overhauling ,lubricating male female contact point and trolley track, closing coil and opening coil 230volt ,checking control wiring and IDMT relays rectified defects including reassembling all the dismantle components to its original position with testing and commissioning of switch gear to the entire satisfaction of Engr-in-charge
Decoupling pump & motor, opening the body of motor, taking out burnt/defective winding wire carefully without damaging the stator, cleaning the slot, rewinding the stator with super enameled copper winding wire of existing gauge along with insulating material, greasing varnishing the bearing complete all as specified and as directed for 7.5 HP capacity of motor.
Decoupling pump & motor, opening the body of motor, taking out burnt/defective winding wire carefully without damaging the stator, cleaning the slot, rewinding the stator with super enameled copper winding wire of existing gauge along with insulating material, greasing varnishing the bearing complete all as specified and as directed for 2.5 HP capacity of motor.
Supply & installed lead Acid battery 12 Volt, 180 AH including testing and commissioning complete.. Make-EXIDE/Amaron
M&L for repair and maint of Smart UPS, 2.2 KVA capacity, Make-APC installed at SF accn Dwarka for smooth functioning of lift elevator including dismantling of enclosure plate and check the all electronic components and detect the UNSV parts ie main PCB, input circuit breaker, battery connector plug, indicators, electronic card etc, repair/replace the same and re-assemble the all components and servicing and maint of batteries with testing and commissioning to entire satisfaction as per directed by Engr-In-Charge
M&L for repair and maint of Smart UPS, 1.0 KVA capacity, Make-APC installed at SF accn Dwarka for smooth functioning of lift elevator including dismantling of enclosure plate and check the all electronic components and detect the UNSV parts ie main PCB, input circuit breaker, battery connector plug, indicators, electronic card etc, repair/replace the same and re-assemble the all components and servicing and maint of batteries with testing and commissioning to entire satisfaction as per directed by Engr-In-Charge
Repair & servicing to as and when required 1000 LPH RO Plant including servicing of raw water pump and high pressure pump ,rewinding of motor if required, servicing & maint of membranes, replace of high pressure switch ,low pressure switch and flow meter if required. Replace of filters and water purify chemicals required for smooth functioning of Plant etc in all complete as per directed by Engr-In-Charge.
Repair & servicing to as and when required for 500 LPH RO Plant including servicing of raw water pump and high pressure pump ,rewinding of motor if required, servicing & maint of membranes, replace of high pressure switch ,low pressure switch and flow meter if required. Replace of membrane filters and Water purify chemicals required for smooth functioning of Plant etc in all complete as per directed by Engr-In-Charge
Supply and filling of engine oil, Kirloskar super 15W40 of DG sets where directed and as specified by; the manufacturers.
Supply and filling of radiator premix coolant, Castrol
LOAR, NEW DELHI M & L maintenance and servicing of 125 KVA DG set (Make-Kirloskar) complete including draining out of diesel, draining out engine oil from the sump, flushing the sump and cleaning, replacement of gaskets, fuel filters, oil filters, air cleaner elements and the worn out parts like fuel flexible pipes, nuts, bolts, fuel line etc . filling the starting batteries with electrolyte, applying petroleum jelly in battery terminals poles, checking of voltage, amps, fuel, coolant and exhaust leakages etc tightening all the nuts and bolts to the required torque incl testing in all respect as per directed by Engr-In-Charge.
M & L maintenance and servicing of 62.5 KVA DG set (Make-Kirloskar) complete including draining out of diesel, draining out engine oil from the sump, flushing the sump and cleaning, replacement of gaskets, fuel filters, oil filters, l, air cleaner elements and the worn out parts like fuel flexible pipes, nuts, bolts, fuel line etc . filling the starting batteries with electrolyte, applying petroleum jelly in battery terminals poles, checking of voltage, amps, fuel, and exhaust leakages etc including refilling radiator coolant , tightening all the nuts and bolts to the required torque incl testing in all respect as per directed by Engr-In-Charge
Supply and filling of engine oil, Kirloskar super 15W40 of DG sets where directed and as specified by; the manufacturers.
Maint & servicing of 200 KVA power distribution transformer, 11/0.433 KV out door type, oil cooled including taking out the sample of transformer oil for checking the dielectric strength and acidity test of oil for the presence of moist presence of moisture, impurities etc after the dehydration including top up of transformer oil as per requirement and de-hydration (Filtration) of transformer oil through mobile filtration plant to be used to respective locations duly connecting inlet/outlet to the machine by switching off HT power supply and taking all safety precautions so as to achieve dielectric strength not less 36 to 40 KV per minute rupturing capacity and switch on supply, charging of transformer all as directed by Engr-In-Charge.
Maint & servicing of 750 KVA power distribution transformer, 11/0.433 KV out door type, oil cooled including taking out the sample of transformer oil for checking the dielectric strength and acidity test of oil for the presence of moist presence of moisture, impurities etc after the dehydration including top up of transformer oil and de-hydration (Filtration) of transformer oil through mobile filtration plant to be used to respective locations duly connecting inlet/outlet to the machine by switching off HT power supply and taking all safety precautions so as to achieve dielectric strength not less 36 to 40 KV per minute rupturing capacity and switch on supply, charging of transformer all as directed by Engr-In-Charge.
Supply, fill and topping up of transformer oil duly tested for proper de-electric strength up to desired level after heating up oil in each transformer all as directed
Supply and fix HT 11 KV out door type gang operated air-break switch suitable for horizontal or vertical mounting rotating type complete with 9 insulators of rating upto 400 Amps
M&L for earthing of machinery/ equipment installed at power house/ sub station, using 25X3 mm copper strip and earth electrode 600x600x3mm as required length and copper plate of size 600X600x5mm thick with necessary earth excavation for earth pit at required depth & width incl connecting between earth electrode to body/neutral of transformer and casting of PCC earth pit chamber with CI cover incl watering pipe, salt, charcoal etc in all complete
M&L for providing and laying of crushed stone/aggregate suitable size for insulation purpose of 11 KV sub station in all respect as directed by Engr-in-Charge.
Repair & servicing to as and when required 1000 LPH RO Plant including servicing of raw water pump and high pressure pump ,rewinding of motor if required, servicing & maint of membranes, replace of high pressure switch ,low pressure switch and flow meter if required. Replace of filters and water purify chemicals required for smooth functioning of Plant etc in all complete as per directed by Engr-In-Charge.
M&L for replacement of single phase split type AC out door unit fan motor 230 volt ,AC,50 Hz with copper bush including necessary power connection with testing complete.
M&L for replacement of capacitor of 3 mfd suitable for 1.5 ton capacity air conditioner including necessary connection with testing complete.
M&L for servicing to air conditioner split/window type of 1.5/2 ton capacity installed by disconnecting power connection and removing front PVC grills , filters cleaning washing with chemical copper condenser coil and cooling coil servicing cleaning fans including minor repair and replacement of grill filters where ever required with re assembling dismantled component to its original position with testing grill temperature to the optimum efficiency of machine to the entire satisfaction of Engr-in-Charge
Dismantling & taking down unserviceable sealed unit compressor from existing 1.5 ton split air conditioners of any make and replace the same by original manufacture / authorized dealer , 1.5 ton capacity sealed unit including necessary brazing and cleaning work and charging of refrigerant gas, including provision of new bushes, grommets, sleeves, washers , mounting rubbers , nuts bolts, terminal covers & clips, complete all as specified and directed with pressure testing complete to the entire satisfaction of Engr-in-charge.
M&L for refrigerant gas charging in split/window type air conditioner of any make/model as per desired pressure with minor repairs to copper tubing across including pressure testing for detection of leakages, vacuumsing etc complete to the entire satisfaction as directed by Engr-In-Charge.
Replacement of unserviceable fan motor with blade 1/32 Horse Power capacity suitable for water coolers 40/80 Ltr, complete all as specified and directed , Make:- AUE/Crompton
Taking out carefully old unserviceable sealed unit of make Shri Ram/ Kriloskar/Techumesh Model SR-412,4440/2612/CAJ 34 Compressor from water cooler 40/80 Ltr Capacity and replaced with factory reconditioned sealed unit from manufacture / authorized dealer of same model , after replacing the liquid line filter including oil and gas charging and necessary brazing work flushing cooling and condenser coil with CCI-4 solution including testing on pressure complete all as specified and directed
Taking out old unserviceable starter of any type and supply and fixing of starter automatic star delta 415 volt 3 phase make Havells /L&T suitable for 5 HP motor pump set in all complete
Decoupling pump & motor, opening the body of motor, taking out burnt/defective winding wire carefully without damaging the stator, cleaning the slot, rewinding the stator with super enameled copper winding wire of existing gauge along with insulating material, greasing varnishing the bearing complete all as specified and as directed for 5 HP capacity of motor.
M&L for servicing of dessert cooler including replace of natural grass cleaner , water pipe, switches, regular if required, cleaning of water storage tank removing of old water and refilling fresh water and testing in all complete.
Replacement of unserviceable fan motor with blade suitable for dessert cooler complete all as specified and directed , Make:- AUE/ Havells / Crompton or equivalent
Replace of water pump suitable for dessert cooler incl testing in all complete
Rewinding the ceiling fan motor of 1200 mm sweep, with super enameled copper wire of appropriate gauge inc replacement of insulating materials such as laminated elytroid paper, sleeves, necessary varnishing with golden colour varnishing, greasing/oiling of bush and the bearing, replacement of missing/worn out nut, bolt& washer etc and lesting after reassembling the same complete all as specified and directed.
Rewinding the ceiling fan motor of 1400 mm sweep, with super enameled copper wire of appropriate guage inc replacement of insulating materials such as laminated lethroid paper, sleeves, necessary varnishing with golden colour varnishing , greasing/oiling of bush and the bearing, replacement of missing/worn out nut,bolt &washer etc and lesting after reassembling the same complete all as specified and directed. Make : For item No 7&8, Wire : Devi Dayal / HTP Ltd Bombay / Victor, Varnish : MODI / CHINAR / LOTUS. NOTE : For item No 7&8 : quoted rate of above item is inclusive of disconnection and taking down ceiling fan, rod blade set of three and opening out the ceiling fan for rewinding.
Replacement of capacitor 2.5 Mfd for ceiling fan of any make/model/sweep, complete. Make:- EPCOS/ NICCO/ USHA/ UNISTAR.
Replace of MCCB 200 A, 4 pole, 415 volts (Make- L&T/Havells)
NAITIK ASSOCIATE
GIRI AND SONS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .