Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
10 Dec 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Maj Sarith E
GE (WEST) MATHURA
REPAIR / MAINT OF STARTER PANELS, CABLES AND ALLIED WORKS AT VARIOUS PUMP HOUSES UNDER GE (WEST) MATHURA
2026_MES_799548_1
8300/1425/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
GE (WEST) MATHURA
As per NIT
10 documents required · 10 mandatory
₹500
GE (WEST) Mathura
₹80,000
Yes
19 Nov 2026
19 Nov 2026
17 Dec 2026
19 Nov 2026
10 Dec 2026
3 Dec 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation, testing and commissioning of fully automatic oil immersed auto transformer motor starter / controller panel (Pedestal type) filled with transformer oil suitable for 125 HP rating of induction motor, rated voltage 415 Volt AC in sheet steel enclosure with IP-53 protection duly painted with weather resistant enamel paint, copper wire wound oil immersed auto transformer having E class insulation, impregnated in varnish with voltage tapping of 50%, 65% & 80% of rated voltage suitable for 03 Starts/Hr in duration of 15 Second each with 03 Nos oil immersed contactors, thermal overload relay of range 90 to 150 Amps, coil voltage 415 Volt AC, push button for ON-OFF operation, with provision of Ammeter, Voltmeter with selector switch and ON, OFF & Trip indication LED lamps including Voltmeter, single phase preventor, HRC fuse fitted inside the panel all as conforming to IS/IEC 60947-4-7 including dismantling of old worn out starter panel complete in all respect and as directed. | 2 | Each | - | - |
| 2 | Supply & fixing in replacement of worn out starter with fully automatic star delta ( FASD) starter/controller suitable for 75 HP, 3 phase, 415 volt AC, AC-3 duty induction motor in sheet steel enclosure with IP 54 protection to changeover from star winding to delta winding with the help of electronc timer, having ON/OFF operation and overload protection with additional features like Auto ON (with 30 sec ON Delay), indications of supply ON/OFF and pump ON/OFF, reading of real time voltage & current of pump with unique dual analog meter, single phasing protection relay (SPPR), relay range 66 to 110 Amp, wide band coil operation from 65% to 110% of rated coil voltage - 380/415 Volt, phase-reversal protection, phase-unbalance protection, variable time-delay adjustment inside controller complete in all respect and conforming to IS/IEC 60947-4-1 standards complete all as specified and directed. | 7 | Each | - | - |
| 3 | Supply & fixing in replacement of MCCB - 125 Amp, 415 Volt, 4 pole, 25 KA with adjustable thermal magnetic protection, Ics = 100% Icu, thermal adjustable - 0.8 to 1 In, magnetic adjustment - 5 to 10 In in accordance with IS/IEC 60068-2-6 standard including making connection, testing and commissioning in DB complete all as specified and directed. | 8 | Each | - | - |
| 4 | Supply & fixing in replacement of MCCB - 160 Amp, 415 Volt, 4 pole, 36 KA with adjustable thermal & magnetic protection/setting, Ics = 100 % Icu, thermal adjustable - 0.8 to 1 In, magnetic adjustment - 5 to 10 In in accordance with IS/IEC 60068-2-6 standard including making connection, testing and commissioning in DB/LT Panel complete all as specified and directed. | 5 | Each | - | - |
| 5 | Supply & fixing in replacement of MCCB - 200 Amp, 415 Volt, 4 pole, 36 KA with adjustable thermal & magnetic protection/setting, Ics = 100 % Icu, thermal adjustable - 0.8 to 1 In, magnetic adjustment - 5 to 10 In in accordance with IS/IEC 60068-2-6 standard including making connection, testing and commissioning in DB complete all as specified and directed. | 5 | Each | - | - |
| 6 | Supply & fixing in replacement of MCCB - 250 Amp, 415 Volt, 4 pole, 36 KA with adjustable thermal & magnetic protection/setting, Ics = 100 % Icu, thermal adjustable - 0.8 to 1 In, magnetic adjustment - 5 to 10 In in accordance with IS/IEC 60068-2-6 standard including making connection, testing and commissioning in LT panel complete all as specified and directed. | 6 | Each | - | - |
| 7 | Supply & fixing in replacement of MCCB - 315/320 Amp, 415 Volt, 4 pole, 36 KA with adjustable thermal & magnetic protection/setting, Ics = 100 % Icu, thermal adjustable - 0.8 to 1 In, magnetic adjustment - 5 to 10 In in accordance with IS/IEC 60068-2-6 standard including making connection, testing and commissioning in LT panel complete all as specified and directed. | 2 | Each | - | - |
| 8 | Supply & fixing in replacement of MCCB - 400 Amp, 415 Volt, 4 pole, 36 KA with adjustable thermal & magnetic protection/setting, Ics = 100 % Icu, thermal adjustable - 0.8 to 1 In, magnetic adjustment - 5 to 10 In in accordance with IS/IEC 60068-2-6 standard including making connection, testing and commissioning in LT panel complete all as specified and directed. | 2 | Each | - | - |
| 9 | Supply & fixing in replacement of MCCB - 630 Amp, 415 Volt, 4 pole, 36 KA with adjustable thermal & magnetic protection/setting, Ics = 100 % Icu, thermal adjustable - 0.8 to 1 In, magnetic adjustment - 5 to 10 In in accordance with IS/IEC 60068-2-6 standard including making connection, testing and commissioning in LT panel complete all as specified and directed. | 1 | Each | - | - |
| 10 | Supply & fixing in replacement of MCCB - 800 Amp, 415 Volt, 4 pole, 36 KA with adjustable thermal & magnetic protection/setting, Ics = 100 % Icu, thermal adjustable - 0.8 to 1 In, in accordance with IS/IEC 60068-2-6 standard including making connection, testing and commissioning in LT panel complete all as specified and directed. | 1 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.46 MB
Tender1425.pdf
Tender Documents • 1.17 MB
BOQ_897077.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .