Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.7 LAccepted-AOC 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | L1 | Accepted-AOC Being lowest bidder. | |
| 2 | L2₹49.5 L+₹77,989.92 (1.60%)Rejected-Finance MOHALLA KAMA KHAN WARD NO 07 HOUSE NO 88 DISTT POONCH J K | L2 | Rejected-Finance Being other than lowest bidder. |
Tender Value
₹42.6 L
EMD Value
₹85,200
Closing Date
20 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF JAMMU
GE AF JAMMU
CA NO GE/AFJ-14/2023-24 PROVISION OF FRP SHETERS (QTY- THREE) FOR ACCOMMODATION OF PERSONNEL AND PROVN OF REST ROOM FOR DSC GUARDS NEAR DSC GUARD POST AT SHASHITAR UNDER GE (AF) JAMMU
2023_MES_597978_4
CA NO GE/AFJ-14/2023-24
Open Tender
Civil Works
Item Rate
SHASHITAR AND JAMMU
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE(AF) JAMMU
₹85,200
Yes
6 Feb 2024
20 Oct 2023
23 Nov 2023
20 Oct 2023
20 Nov 2023
31 Oct 2023
Amount
SCHEDULE 'A' PART-I (SITE CLEARANCE AND COMMON NATURE WORK)
Rough excavation n exc 1.50m deep and getting out in soft disintegrated rock, complete all as specified & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified.
Description all as per srl item no.1.02 above but in rock, complete all as specified & directed.
Surface excavation n exc 30cm deep and averaging 15cm deep and getting out insoft/loose soil, complete all as specified & directed
Surface excavation n exc 30cm deep and averaging 15cm deep and getting out in any type of soil, complete all as specified & directed
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5m in depth in softdisintegrated rock soil and getting out, complete all as specified and as directed
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5m in depth in soft/loose soil and getting out, complete all as specified and as directed
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specified.
M&L for precast cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate in foundations, filling and mass concrete complete all as specified & directed.
M/L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in built in cement mortar 1:6 complete all as specified & directed.
M/L for rendering 15mm thick on fair faces of brick work in CM 1:4 finished even and smooth with out using extra cement but using integral water proofing compound as per manufacturer,s instructions, complete all as specified. Note : Integral water proofing compound shall be measured & paid seprately.
M/L Hardcore of guage not exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick watered and rammed to true surface with broken bricks complete all as specified & directed.
SCHEDULE 'A' PART-II (BUILDING WORK)
Sand filling under floors or in fdn incl watering and consolidation under floors complete all as specified & directed.
M/L for 75 mm thick cement concrete type D2 1:4:8 ( 40mm graded acrushed stone aggregate) as in sub base complete all as specified & directed.
M&L for 25mm thick Plain Cement Concrete 1:2:4 type B0 (using 12.5mm graded crushed stone aggregate) as in floor base for tiles complete all as specified and directed.
M&L for Non skid coloured glazed ceramic tiles 7 to 8 mm thick square / rectengular area of each tile exc 0.11 sqm not exc 0.18 sqm in floors etc set and jointed neat cement slurry and pionted white or coloured cement to match including 15mm thick screed bed complete all as specified & directed.
M&L for Mild Steel work in tubular trusses / purlinsincluding MS plates,nuts & bolts and gusset plates frames, flat iron including special shaped washer etc. complete using ERW or induction butt weldedtubes conforming to I. S.1161-1979 grade St.-240 complete all as specified & directed. Note:- Measurement to be made as per actual weight of nuts & bolts and MS plates etc
S&F for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-In-Charge.
M/L preparation of new surface and applying two coats of synthetic enamel paint on steel surfaces , over 10 cm in width or grith over a coat of zinc oxide primer not other wise described complete all as specified & directed.
S/F of 50mm th PUF insulated Board made of 0.50 mm thick GI sheet powder coated filled with PUF for thermal insulation including necessary fixtures and fittings of same material fixed with self drilling screw and sealed with epoxy sealent complete all as specified and directed by Engr-In-Charge.
S/F of 50mm thick PUF insulated Board made of 0.63 mm thick GI sheet (one side corugated and one side plane) powder coated filled with PUF for thermal insulation on roof including necessary fixtures and fittings of same material fixed with self drilling screw and sealed with epoxy sealent complete all as specified and directed by Engr-In-Charge.
S&F anodised aluminium powed coated window with glazed and wire mesh ,shutter sliding type using 1.60 mm thick aluminium open three track section having specific size of style ,top rails and bottom rails including anodised aluminium frame including necessary joining cleats, glazing clips rubber packing, anodised aluminium snap beading screws, anodised aluminium fittings complete and including glazing by using 5mm thick plain sheet glass and stainless steel wire mesh of dia 0.36 mm and aperture 1.40 mm including aluminium grill of 50x50 mesh complete all as specified and as directed Note :- S& F of 5mm thick glass & SS wire mesh hinges if any required are included in the items No payment will be made separately)
S&F Aluminium anodised powder coating grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in- charge.
S&F Pressed steel frames (Factory made) made out of 1.25 mm thick black MS sheet for doors, with one or more rebates including necessary fixing lugs, Butt hinges, lock strike plate, etc complete, size of frame 125x60mm incl bottom of each chowkat to be welded with 2 nos 25x25x3mm thick flat iron projecting 10 cm on either side and back fill to chowkhats with PCC 1:3:6 type C-0 using 12.5mm crushed stone aggrgate complete all as specified.
S/F 30mm thick flush shutters solid core construction with block board core and plywood face panels commercial type on both sides complete all as specified and as directed by Engr-In-Charge.
S&F 100 mm size MS butt hinges medium weight cold rolled fixed/ welded to frame complete all as specified and as directed by Engr-in-Charge.
S/F MS sliding door bolt ,plate type stove enammeled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts four on bolt plate and two on staple plate 300mm long complete all as specified and as directed by Engr-in-Charge.
S&F 200 mm long,aluminium,anodised, barrel tower bolts of extruded section complete all as specified and as directed by Engr-In-Charge.
S&F 150mm size aluminium handles,cast type,anodised complete all as specified and as directed by Engineer-In-Charge.
M & L for painting to new wood and wood based surfaces of any description exc 10cm with or girth with two coats of synthetic enamel paint over a coat of pink primer including preparation of new or previously untreated surface, complete all as specified and as directed.
S&F cast iron body hydraulic door closer regulated, designation No.2, universal type suitable for door shutters of weight between 36 to 60 kg complete all as specified and as directed.
M & L for preparing of new plastered surfaces on walls and applying two coat of exterior emulsion paint in camouflage patter over a coat of primer complete all as specified and as directed.
M&L RCC M-25 design mix using 20 mm graded aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L RCC M-25 design mix using 20 mm graded aggregate in Columns, pillars, piers, posts and struts complete all as specified and as directed.
M&L RCC M-25 design mix using 20 mm graded aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft & raft beams, sides & soffits of foundation & plinth beams; and similar work; verticle or to batter Rough finished surfaces of concrete flat complete all as specified and as directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work; exc. 200m thick (Horizontal or sloping) rough finished surfaces of concrete flat complete all as specified and as directed.
Formwork to sides of pillars, posts, struts, piers,columns, and stanchions rough finished surfaces of concrete Square, rectangular or polygonal complete all as specified and as directed.
M&L RCC M-25 design mix using 20 mm graded aggregate in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M & L for MS TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking bending spiirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not les than 0.9 mm dia or securing with clips quaility conforming to complete all as specified and as directed.
Mild steel bars TMT 5 to 10 mm mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia as in stirrups complete all as specified and as directed.
Supplying only Integral waterproofing compound
M&L rendering 15 mm thick CM 1:6 on other than fair faces of brick work or concrete surface complete all as specified and as directed.
M&L rendering 10 mm thick CM 1:3 on fair faces of brick work or concrete surface as in roof slab, column, beam complete all as specified and as directed.
M&L 100mm thick PCC type C-2, (1:3:6) using 40mm graded crushed stone aggregate complete all as specified and as directed.
M&L 25mm thick PCC type B-1, (1:2:4) using 20mm graded crushed stone aggregate complete all as specified and as directed.
M&L 15mm thick screed for laying floor finishes in CM (1:4) complete all as specified and as directed.
S&F Coloured Non Skid ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
Description all as per item no 2.36 above but as on skirting on wall over 10mm thick plaster in CM(1:4) on fair face of brick or concrete surface complete all as specified and as directed.
M&L applying two coats of distemper oil emulsion, white or tinted over a coat of primer on new ceiling surface including preparation of surface complete all as specified and as directed.
M&L applying two coats of distemper oil emulsion, white or tinted over a coat of primer on new wall surface including preparation of surface complete all as specified and as directed.
M&L preparation of new plaster surface of walls and applying two coat of cement base paint over a coat of alkali resistant primer complete all as specified and as directed.
S&F Pressed steel frames (Factory made) made out of 1.25 mm thick black MS sheet for doors, with one or more rebates including necessary fixing lugs, Butt hinges, lock strike plate, etc complete, size of frame 105x60mm incl bottom of each chowkat to be welded with 2 nos 25x25x3mm thick flat iron projecting 10 cm on either side and back fill to chowkats with PCC 1:3:6 type C-O using 12.5 mm graded crushed stone aggregate complete all as specified.
S&F steel windows with side hung shutters including projecting type hinges with steel handles, 2 Nos steel tower bolts 100mm long peg stay complete with glazing bars, dovetailed or welded complete all as specified directed by the Engr-in-Charge.
Description all as per srl item No 2.42 here in before but without glazing bars complete all as specified and as directed.
S&F MS framed work such as grills, gratings, framed guard bars etc and similar work, confirming to Fe 410-0 or Fe 310-0, complete all as specified directed by the Engr-in-Charge.
S&F factory made Plain framed, panelled shutter (two panel) with lock rail and panelor 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated 2nd class hard wood fitted to chowkats complete all as specified directed by the Engr-in-Charge.
S&F 2nd class hardwood 35mm thick glazed and skelton, shutters, open rebated and prepared to receive glass, gauze without sash bars all as specified in SSR Pt I, Section 8, clause 8.20 (a) complete all as specified directed by the Engr-in-Charge.
S&F sheet glass 3 mm thick, ordinary quality and glazing with oil putty or wooden bedding in square exc .5 Sqm in each pane complete all as specified directed by the Engr-in-Charge.
Supply and fixing galvanised mild steel wire cloth 0.56mm nominal dia wire and average width of aperture 1.18mm and fixed with tinned tacks of galvanised wire staple to steel windows/fixed with wooden beads of 2nd class HW to wooden doors/windows complete all as specified directed by the Engr-in-Charge.
S&F Mild steel barrel tower blots 200mm long, stove enamelled black, with bright bolt complete all as specified directed by the Engr-in-Charge.
S&F aluminum handle150 mm size, cast type, anodized complete all as specified directed by the Engr-in-Charge.
S&F Mild steel sliding door bolts 300mm long, plate type, stove enamelled black, with bright bolt not less than 12mm dia with & including a minimum of 6 bolts & nuts, four on bolt plate & two on staple plate complete all as specified directed by the Engr-in-Charge.
M&L for 75mm thick PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection/ path finished even and smooth with out using extra cement including forming and filling of joints 12mm wide with bituminous filler complete all as specified directed by the Engr-in-Charge.
M&L Rendering 15mm thick on brick masonry surfaces or surface other than fair face of brickwork in CM (1:4) complete all as specified directed by the Engr-in-Charge.
M&L for water proofing treatment on horizontal and vertical surface with polymeric water proofing membrane minimum weiging 3.0 kg/sqm and minimum 3mm thick reinforced with polyster non wave fabric (wt. not less than 150 gms/sqm) laid on primed surface by forced application complete all as specified laid overr a coat of of bitumen primer @.30 Ltr/Sqm with applying a coat of hot blown bitumen of 85/25 or 95/15 @ 1.20 Kg/Sqm. APP membrance shall be laid by torching with 75mm overlap in longitudinal direction and 100mm overlap in transverse direction and finally fisished with a coat of solar reflective bituminous aluminium paint @ 100 grams/Sqm all as specified and as directed by Engr-in-Charge.
M&L for GI snap grid frame work for false ceiling fixed to surrounding wall and hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof with GI flat 40x3mm size 60mm long and expansion hold fasteners complete and with 6mm thick non asbestos cement composite board of designer ceiling of size 59.50cm x59.50cm ,fixed in ceiling with screws to frame work with GI channel powder coated at bottom,frame work complete all as per manufacture instruction complete all as specified and as directed by Engr-in-Charge.
SCHEDULE 'A' PART-III (INTERNAL ELECTRIFICATION)
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multi strand copper conductor of size 1.5 Sq mm FRLS (Nominal area) drawn through PVC conduit concealed in wall, ceiling with GI saddles GI screws, rawl plugs (concealed conduit wiring) with all fittings including Tee, Junction boxes and provision of pressed steel terminal box powder coated of suitable size with 3 mm thick laminated sheet cover for mounting switch sockets and regulators and drawing continuous earth wire of PVC insulated unsheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) complete all as specified. Note: Cost for cutting, chasing and making good to existing surfaces are deemed to be included in the Quoted Rate.
For one light point controlled by one SP switch
For one fan/exhaust fan and wall mounted fan point controlled by one SP switch.
All as per Srl item No. 3.01 here-in-before but for one 3 pin 5 Amps socket out let point on the same board with the cable 2.5 Sqmm size controlled by one switch and continouus earthwire of PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 2.5sqmm complete all as specified and directed by Engr-in-Charge.
All as per item No-3.01 above but for one 3 pin socket out let, 6 Amps on Independent board with the cable 2.5 Sqmm size and continouus earthwire of PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 2.5sqmm complete all as specified and directed by Engr-in-Charge.
All as per item No-3.01 above but for one 3 pin socket out let, 16 Amps on Independent board with the cable 2.5 Sqmm size and continouus earthwire of PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 2.5sqmm complete all as specified and directed by Engr-in-Charge.
S & F socket outlet 5 pin, 6 amps flush type complete all as specified and as directed by Engineer-in-Charge.
S & F socket outlet 6 pin, 16 amps (Multi pin) flush type complete all as specified and as directed by Engineer-in-Charge.
S & F switch piano flush button type 6 amps single pole one way.
S & F switch piano flush button type 16 amps single pole one way.
S & F ceiling rose surface bakelite 2 to 3 terminals 65 x 50mm complete all as specified and as directed by Engineer-in-Charge.
S & F of lamp holder insulated body with back plate for batten fitting including LED bulb 12 watt (SSK-PAG-N-12W)complete all as specified and directed by Engineer-in-Charge.
S & F energy saving decorative box type batten light fitting surface mounted complete with high efficiency PMMA diffuser soft glare free light LED lamp 20 watt suitable for 120 volts to 270 volts of system efficacy not less then 90 lumen/watt, with all accessories, pre-wired, including lamp and providing flexible copper wire, twin core cable complete all as specified and directed by Engineer-in-Charge.
S & F energy saving decorative box type batten light fitting surface mounted complete with high efficiency PMMA diffuser soft glare free light LED lamp 08/10 watt suitable for 120 volts to 270 volts of system efficacy not less then 90 lumen/watt, with all accessories, pre-wired, including lamp and providing flexible copper wire, twin core cable complete all as specified and directed by Engineer-in-Charge.
Supply and fixing PVC exhaust fan with louvers of size 250 mm sweep, 900 RPM 230 volts single phase AC supply complete with, bolt, nuts and washers, suitably embedded in the wall including making suitable opening and provisioning of flexible cord copper of size 23/0.0076 from ceiling rose to exhaust fan for giving connection complete all as specified and directed by Engineer-in-Charge.
Supply and fix stepped type electronic fan regulator flush type on the phenolic laminated sheet etc as required.
M & L for sub main wiring with two single core FRLS, PVC insulated, stranded, unsheathed cable copper conductor with size 04 Sqmm and drawing through & including Non metallic PVC conduit concealed in wall including earth continuity conductor of size 04 Sqmm PVC insulated unsheathed stranded copper conductor cable and connected to earth dolly to be drawn in ccocealed PVC conduit including connecting to main board complete all as specified and directed by Engineer-in-Charge. Note:- Conduit will be measured and paid separately.
S & F rigid non metalic PVC conduit 25 mm exclusives of boxes but incl all Tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles and pipe hooks etc complete all as specified and directed by Engineer-in-Charge.
S&F sheet metal enclosures for MCBs, single pole and neutral, 08 ways 240 Volts double door type complete all as specified and directed by Engineer-in-Charge.
S&F MCB SP 1 to 32 Amps, 240 Volts complete.
S&F MCB SPN upto 32 Amps ,240 Volts complete.
S & F in repair Lamp holder, PVC/Polycarbonate type with back plate and 12W LED Lamp suitable for batten fittings complete incl taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge.
S&F energy saving decorative box type batten light fitting surface mounted complete with high efficiency PMMA diffuser soft glare free light LED lamp 20 watt suitable for 120 volts to 270 volts of system efficacy not less then 90 lumen/watt, with all accessories, pre-wired, including lamp and providing flexible copper wire, twin core cable complete all as specified and directed by Engineer-in-Charge.Make:- Havells ,Crompton Greaves/ Philips/Bajaj.
Supply and fixing of 10 Watt energy efficient wall mouted LED Bulk head luminaire made off die cast aluminium with opal diffuser IP 65 Crompton ,Philips/Wipro
S&F sheet metal enclosures for MCBs, single pole and neutral, 04 ways 240 Volts double door type complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.0 sq mm 2 core complete all as specified and directed by Engr-in-Charge
Supply and fix stepped type electronic fan regulator flush type on the phenolic laminated sheet etc as required complete all as specified and directed by Engr-in-Charge
Supply and fixing ceiling fan size 1200 mm sweep, 230 volts single phase AC supply complete with bolt, nuts and washers including fan hook with 5 star rating(BLDC) complete all as specified and directed by Engr-in-Charge
SCHEDULE 'A' PART-IV (EXTERNAL ELECTRIFICATION WORK)
Supply & fixing GI tubing light grade 50 mm bore on poles, under floors, road crossing etc complete all as specified and directed by Engr-in-Charge
Supply, Laying, connecting including taking out testing XLPE cable underground PVC insulated and over all sheathed with aluminium conductor heavy duty 1100 volts grade of size 35sqmm 3.5 core laid in trenches, floors, ducts passing through pipe for road crossing etc complete all as specified and directed by Engr-in-Charge. Note:-Excavation, earth work, brick protection sand cushioning and GI pipe etc shall be measured & paid for separately
S & F of Cable jointing kit suitable for 11 KV grade cable end termination, heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 to70 sq mm complete all as specified and directed by Engr-in-Charge
Supply, Laying, connecting including taking out,testing XLPE cable underground PVC insulated and over all sheathed with aluminium conductor heavy duty 1100 volts grade of size16 Sqmm 2 core laid in trenches, floors, ducts passing through pipe for road crossing etc complete all as directed by Engr-in-Charge. Note;-Excavation, earth work, brick protection sand cushioning and GI pipe etc shall be measured & paid for separately.
M & L for earthing complete with galvanized steel earth plate electrode 60 x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to earth lead galvanised iron strip 25×4mm by means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvd iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of 2009 complete with necessary earth work in any type of soil, removal to a distance not exc. 50m, testing on completion complete all as specified & directed .. Note : RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover.
Supply, install, test and commission out door type cubical feeder pillar box outer shell made out of 3.15 mm thick MS sheet inner shell made out of 2 mm thich MS sheet and MS angle section 50x50x6 mm on PCC 1:2:4 type B-1 platform 45cm above the ground level and 30 cm below the ground level, frame factory fabricated with front and back open able double door system complete suitable for 3 phase 4 wire 415 Volt, 50 Hz, Size of panel board- 1.0X0.9X0.5 Mtr, a) TPN, Aluminium bus bar 300 Amps insulated with colour coded heat shrinkable sleeve. b) Incoming MCCB 4 pole 100 Amp 25 KA -01 No Make - Schneider/Legrand/Siemens/ABB c) Out going MCCB TP 63 Amps 16 KA - 1 Nos (d) Out going MCB SPN 63 Amps 10 KA - 4Nos e) Indicator lamps RYB –01 S et f) Voltmeter 0-500 volts 96 mm square flush pattern-01 No. Make -AE f) Amp meter 0-200 Amps 96mm square flush pattern - 01 No Make-AE Note :- (i) The quoted rate shall includes minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc. (ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming to IS-694. (iii) Panel drawing shall be got approved before placing of order from Engr-in-Charge/GE. (iv) The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated.
(vi) The Panel shall be surrounded with 9 inch brick wall upto 0.5 mtr height all around the panel and blank portion between panel and wall shall be filled with PCC 1:2:4 incl masonary work leaving ducts for cables complete all as directed. (vii) All MCCBs have Ics= 100% Icu. . Note :- (i) The quoted rate shall includes minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc. (ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming to IS-694. (iii) Panel drawing shall be got approved before placing of order from Engr-in-Charge/GE. (iv) The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated. (vi) The Panel shall be surrounded with 9 inch brick wall upto 0.5 mtr height all around the panel and blank portion between panel and wall shall be filled with PCC 1:2:4 incl masonary work leaving ducts for cables complete all as directed. (vii) All MCCBs have Ics= 100% Icu. .
Supply and laying of DWC (Double Wall Corrugated) HDPE Pipe, ISI Marked IS 16205 Part-II, of outer dia of 120 mm and inner dia 103 mm with smooth internal and profiled external surface for non pressure under ground cable including all connected accessories like coupler, 'O' Ring etc, for protection of cable complete all as specified and as directed
SCHEDULE 'A' PART-V (EXTERNAL WATER SUPPLY WORK)
Supply & laying galvanised medium class including fitting 25mm91') dia complete all as specified and directed by Engr-in-Charge
SCHEDULE 'A' PART-VI (LIGHTENING PROTECTION WORK)
S&F single pointed air termination aluminium rod 12mm dia 300mm long complete all as specified and as directed.
S &F Aluminium strip 25 x 3mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and as directed.
Galvanised iron strip 32 x 6mm buried in ground complete all as specified and as directed
Test point terminal block made out of gun metel or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 nos 8mm dia 25 mm long hex head screw complete all as specified and as directed.
Earthing complete with galvanized steel earth plate electrode 600x600x6mm burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead strip of 32x6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC 1:2:4 in pit with pre- cast RCC 1:2:4 cover reinforced with XPM not less than 4 Kg Sqm, test point etc. all as shown in electric plate No. 3 of SSR Part-I complete with necessary earth work in any type of soil, removal to a distance not exc. 50m, testing on completion complete all as specified & directed .. Note : RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover.
Cement concrete in mass concrete type C1, 1:3:6 (20 mm graded aggregate) for errection of poles above ground level and coping etc. including necessary formwork complete all as spd and directed.
S & F GI tubes light grade of dia 32mm with all fitting and fixed with Air termination rod pipes by means of double clamps on top incl duly painted with synthetic enamel alluminium paint over a coat of red oxide primer all as spd and indicated and of length not less than 1.5 meter complete all as specified and as directed.
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed.
Supply and fixing PVC earthing strip DMC insulator for , for electrical installation surface treatment colour coated , tensile strenth 25 Mpa including washer Nut & bolts etc complete all as specified and as directed.
SCHEDULE 'A' PART-VII (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch 'A' Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder.
JAMWAL CONSTRUCTION CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .