Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.4 LAccepted-AOC 2 EVEREST VIHAR PT T N MISHRA MARG NIRMAN NAGAR JAIPUR 302019 | JAIPUR | RAJASTHAN | 302019 | ₹17.4 L Quoted ₹17.9 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹18.6 L+₹71,570 (4.00%)Rejected-Finance | ₹18.6 L+₹71,570 (4.00%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹19.2 L+₹1.3 L (7.47%)Rejected-Finance | ₹19.2 L+₹1.3 L (7.47%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹20.0 L+₹2.1 L (12.0%)Rejected-Finance | ₹20.0 L+₹2.1 L (12.0%) | L4 | Rejected-Finance Other than lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
27 Dec 2019, 6:00 pmClosed
GE AF UTARLAI
GE AF UTARLAI PB No 11 BARMER (RAJ) 344001
SPL REPAIR TO LT PANELS, PROVN OF LIGHTNING ARRESTER WITH EARTH PITS FOR BPI BUILDING AND CHEMICAL EARTH PITS IN MET AND LGS SECTION AND PROVN OF SHUTTER FOR POL SHED, FLAME PROOF LIGHT, WATER POINT FOR TYRE WASHING AT AF STN UTARLAI
2019_MES_300741_2
8698/05/E8 dt 25 Nov 2019
Open Tender
Civil Works
Item Rate
180 days
GE AF UTARLAI
As per NIT
7 documents required · 7 mandatory
₹500
Yes
GE AF UTARLAI
₹50,000
Yes
14 Jan 2020
11 Dec 2019
28 Dec 2019
11 Dec 2019
27 Dec 2019
12 Dec 2019
Amount
Supply, install, testing and commissioning in replacement of factory made and tested (including CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted, compartmentalized and IP-54 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated copper bus bars 300 amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, made of 3.15mm thick CRCA MS sheet and with base frame of 50x50x6mm angle iron, powder coated, Front and rear opening type with aprons for cable entry with double door shutter and locking arrangement including foundation & PCC 1:3:6 type C-2 using 40mm graded stone aggregate work and with necessary internal wiring with standard copper conductor PVC insulated cables of adequate size & cable glands for cable entry and exit and including consisting following. The panel height should be 1.0 Mtr from ground level. (Location- Z-1, Z-2, Z-4, Z-5, Z-6, Z-7, Z-8) Incoming (a) MCCB 100 amps, 4 pole, 25 KA, 415 volts grade, (Ics=100% Icu) with thermal magnetic including making connections with thimbles - 01 No (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 300 Amp, 4 pole, not less than 45 cm long mounted on insulators for incoming supply - 01 No. (c) Digital Load manager multy functional energy meter having facility to measure true RMS value, KWH, neutral current, for quadrant energy, max demand (KW, KVA, Kvar & Amp), 3rd to 15th and harmonics, CT operated 415 volts, 50 Hz AC supply including CTs. - 01 set. (d) Neon indicating lamps (R, Y & B) - 01 Set. Outgoing (a) MCCB 63 amps, 4 pole, 25 KA, 415 volts grade, (Ics=100% Icu) with thermal magnetic - 02 Nos (b) MCB TPN 63 amps, 4 pole, 10 KA , 415 volts, 50 Hz - 01 No. (c) MCB SPN 40 amps,10 KA - 01 No.
Supply, install, testing and commissioning in replacement of factory made and tested (including CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted, compartmentalized and IP-54 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated copper bus bars 500 amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, made of 3.15mm thick CRCA MS sheet and with base frame of 50x50x6mm angle iron , powder coated, Front and rear opening type with aprons for cable entry with double door shutter and locking arrangement including foundation & PCC 1:3:6 type C-2 using 40mm graded stone aggregate work and with necessary internal wiring with standard copper conductor PVC insulated cables of adequate size & cable glands for cable entry and exit and including consisting following. The panel height should be 1.0 Mtr from ground level. (Location- Z-3) Incoming (a) MCCB 250 amps, 4 pole, 36 KA, 415 volts grade, (Ics=100% Icu) with thermal magnetic including making connections with thimbles - 01 No (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonizing, corrosion resistance SMC insulators 500 Amp, 4 pole, not less than 45 cm long mounted on insulators for incoming supply - 01 No. (c) Digital Load manager multy functional energy meter having facility to measure true RMS value, KWH, neutral current, for quadrant energy, max demand (KW, KVA, Kvar & Amp), 3rd to 15th and harmonics, CT operated 415 volts, 50 Hz AC supply including CTs. -01 set. (d) Neon indicating lamps (R, Y & B) -01 Set. Outgoing (a) MCCB 160 amps, 4 pole, 25 KA, 415 volts grade, (Ics=100% Icu) with thermal magnetic - 01 No (b) MCCB 63 amps, 4 pole, 25 KA, 415 volts grade, (Ics=100% Icu) with thermal magnetic - 02 No (c) MCB TPN 63 amps, 4 pole, 10 KA , 415 volts, 50 Hz - 01 No. (d) MCB SPN 40 amps,10 KA - 01 No.
Supply, install, testing and commissioning in replacement of factory made and tested (including CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted, compartmentalized and IP-54 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated copper bus bars 500 amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, made of 3.15mm thick CRCA MS sheet and with base frame of 50x50x6mm angle iron, powder coated, Front and rear opening type with aprons for cable entry with double door shutter and locking arrangement including foundation & PCC 1:3:6 type C-2 using 40mm graded stone aggregate work and with necessary internal wiring with standard copper conductor PVC insulated cables of adequate size & cable glands for cable entry and exit and including consisting following. The panel height should be 1.0 Mtr from ground level. (Location- Between Z-4 & Z-5) Incoming (a) MCCB 250 amps, 4 pole, 36 KA, 415 volts grade, (Ics=100% Icu) with thermal magnetic including making connections with thimbles - 01 No (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonizing, corrosion resistance SMC insulators 500 Amp, 4 pole, not less than 45 cm long mounted on insulators for incoming supply - 01 No. (c) Digital Load manager multy functional energy meter having facility to measure true RMS value, KWH, neutral current, for quadrant energy, max demand (KW, KVA, Kvar & Amp), 3rd to 15th and harmonics, CT operated 415 volts, 50 Hz AC supply including CTs - 01 set. (d) Neon indicating lamps (R, Y & B) - 01 Set. Outgoing (a) MCCB 100 amps, 4 pole, 25 KA, 415 volts grade, (Ics=100% Icu) with thermal magnetic - 03 Nos (b) MCB TPN 63 amps, 4 pole, 10 KA , 415 volts, 50 Hz - 01 No. (c) MCB SPN 40 amps, 10 KA - 01 No.
Supply, install, testing and commissioning in replacement of factory made and tested (including CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted, compartmentalized and IP-54 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated copper bus bars 500 amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, made of 3.15mm thick CRCA MS sheet and with base frame of 50x50x6mm angle iron , powder coated, Front and rear opening type with aprons for cable entry with double door shutter and locking arrangement including foundation & PCC 1:3:6 type C-2 using 40mm graded stone aggregate work and with necessary internal wiring with standard copper conductor PVC insulated cables of adequate size & cable glands for cable entry and exit and including consisting following. The panel height should be 1.0 Mtr from ground level. (Location- ORP 20 End) Incoming (a) MCCB 250 amps, 4 pole, 36 KA, 415 volts grade, (Ics=100% Icu) with thermal magnetic including making connections with thimbles- 01 No (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonizing, corrosion resistance SMC insulators 500 Amp, 4 pole, not less than 45 cm long mounted on insulators for incoming supply - 01 No. (c) Digital Load manager multy functional energy meter having facility to measure true RMS value, KWH, neutral current, for quadrant energy, max demand (KW, KVA, Kvar & Amp), 3rd to 15th and harmonics, CT operated 415 volts, 50 Hz AC supply including CTs -01 set. (d) Neon indicating lamps (R, Y & B) -01 Set. Outgoing (a) MCCB 100 amps, 4 pole, 25 KA, 415 volts grade, (Ics=100% Icu) with thermal magnetic - 04 Nos (b) MCB TPN 63 amps, 4 pole, 10 KA , 415 volts, 50 Hz - 02 Nos. (c) MCB SPN 40 amps,10 KA - 02 Nos.
Supply, install, testing and commissioning in replacement of factory made and tested (including CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted, compartmentalized and IP-54 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated copper bus bars 500 amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, made of 3.15mm thick CRCA MS sheet and with base frame of 50x50x6mm angle iron , powder coated, Front and rear opening type with aprons for cable entry with double door shutter and locking arrangement including foundation & PCC 1:3:6 type C-2 using 40mm graded stone aggregate work and with necessary internal wiring with standard copper conductor PVC insulated cables of adequate size & cable glands for cable entry and exit and including consisting following. The panel height should be 1.0 Mtr from ground level. (Location- ORP 02 End) Incoming (a) MCCB 250 amps, 4 pole, 36 KA, 415 volts grade, (Ics=100% Icu) with thermal magnetic including making connections with thimbles - 01 No (b) Supply and fix change over switch 250 Amps, 4 pole, 415 Volts, 50 Hz, on load open execution type - 01 No (c) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonizing, corrosion resistance SMC insulators 500 Amp, 4 pole, not less than 45 cm long mounted on insulators for incoming supply - 01 No. (d) Digital Load manager multy functional energy meter having facility to measure true RMS value, KWH, neutral current, for quadrant energy, max demand (KW, KVA, Kvar & Amp), 3rd to 15th and harmonics, CT operated 415 volts, 50 Hz AC supply including CTs - 01 Set. (e) Neon indicating lamps (R, Y & B) -01 Set. Outgoing (a) MCCB 100 amps, 4 pole, 25 KA, 415 volts grade, (Ics=100% Icu) with thermal magnetic - 04 Nos (b) MCB TPN 63 amps, 4 pole, 10 KA , 415 volts, 50 Hz - 02 Nos. (c) MCB SPN 40 amps,10 KA - 02 Nos.
Supply, install, testing and commissioning in replacement of factory made and tested (including CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted, compartmentalized and IP-54 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated copper bus bars 500 amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, made of 3.15mm CRCA MS sheet and with base frame of 50x50x6mm angle iron, powder coated, Front and rear opening type with aprons for cable entry with double door shutter and locking arrangement including foundation & PCC 1:3:6 type C-2 using 40mm graded stone aggregate work and with necessary internal wiring with standard copper conductor PVC insulated cables of adequate size & cable glands for cable entry and exit and including consisting following. The panel height should be 1.0 Mtr from ground level. (Location- ORP 02 Blast Pen) Incoming (a) MCCB 250 amps, 4 pole, 36 KA, 415 volts grade, (Ics=100% Icu) with thermal magnetic including making connections with thimbles - 01 No (b) Supply and fix change over switch 250 Amps, 4 pole, 415 Volts, 50 Hz, onload open execution type - 01 No (c) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonizing, corrosion resistance SMC insulators 500 Amps, 4 pole, not less than 45 cm long mounted on insulators for incoming supply - 01 No. (d) Digital Load manager multy functional energy meter having facility to measure true RMS value, KWH, neutral current, for quadrant energy, max demand (KW, KVA, Kvar & Amp), 3rd to 15th and harmonics, CT operated 415 volts, 50 Hz AC supply including CTs -01 Set. (e) Neon indicating lamps (R, Y & B) -01 Set. Outgoing (a) MCCB 160 amps, 4 pole, 25 KA, 415 volts grade, (Ics=100% Icu) with thermal magnetic - 01 No (b) MCCB 100 amps, 4 pole, 25 KA, 415 volts grade, (Ics=100% Icu) with thermal magnetic - 01 No (c) MCB TPN 63 amps, 4 pole, 10 KA , 415 volts, 50 Hz - 01 No. (d) MCB SPN 40 amps, 10 KA - 01 No.
M&L in replacement for earthing complete as per electrical plate No. 3 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less then 1.5 metre below normal ground level connected to and including galvanised iron or steel earth strip 25mm x 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 32mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover tested complete all as specified.
M & L for Supplying, laying, connecting and testing in trenches, under floors/ roads or on walls Cable 25sqmm 4 core XLPE insulated screened PVC bedded galvanized steel strips or wire armored, electric power cables (heavy duty) ISI marked with stranded aluminium conductor, 1100 volts grade including taking out old unserviceable cable with sand/stone patti complete all as specified
M & L in replacement of 40mm bore Galvanised steel tubing light grade for protection of under ground cable on poles / walls under road crossing etc conforming to IS-1239 including taking out/down of existing GI pipes complete all as specified
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and n. exc 1.50m depth for foundation etc or for shafts, wells, cesspits , man holes, pier holes etc n. exc 10 sqm on plan and getting out in soft /loose soil complete all as specified.
Returning, filling in, including spreading, leveling watering & well ramming in layers not exc. 25 cm for soil complete all as specified.
Removal of excavated material at a distance not exc 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as specified
M&L for Providing dry tibba sand in trenches as sand cushioning to U/G cable including punning down of sand in layer complete all as speciied. (Note :- Punned thickness shall only be measured and paid).
M & L for 40 to 50 mm thick rough dressed Jodhpur type stone slab cover 25 to 30 cm wide and 30 to 40 cm in length laid dry abutting each other for cable protection complete all as specified.
S&F Aluminium strip 25x3.15 mm with saddles and fixing screws for roof/earth conductors and down conductors above ground all joints should be connected complete all as specified and directed. Note: All joints should be joined by brazing or by using of nuts and bolts.
S&F Air Termination Single Pointed Aluminium Rod 12mm dia and 300mm long with Galvanized Steel tubing 40mm bore (dia), 1.50 mtr long, "light grade" including provision of Cement Concrete 1:2:4 type B-1 (20mm graded stone aggregate) Block 300x300x300mm and necessary fixing arrangement at roof, compete all as specified and directed. Note: If threaded of the GI Tubing is damaged then Contractor will be responsible for cutting of thread for fixing the GI Tubing.
M&L for electrical earthing with GI plate electrode of size 60cm x 60cm x6.3mm thick buried directly in ground vertically earth pit not less than 2.5 Mtr deep below normal ground level with the top edge of the earth plate at a depth not less 1.5 Mtr below normal ground level connected to GI strip earth lead of size 32 x6 mm by means of bolts, nuts, washers made of galvanized iron and connected main control board/switch gear/panel boards all as specified and shown in Electrical plate No 3 of MES schedule (SSR) Part-I, 2009 including necessary excavation and earth work in any type of soil, charcoal dust, salt and PCC 1:2:4 type B1 in chamber RCC 1:2:4 type B1 cover slab with 6mm dia mild steel bars at 100 mm center to centre both ways and with 6 mm dia MS hook and testing resistance complete all as specified and directed. Note: GI strip 32x6 mm upto 7.5 Mtr length shall be deemed to include in this item rate.
S&F test point terminal block made of gunmetal or prosperous bronze size 75x75x25mm drilled and srewed including 3 Nos 8mm dia 25 mm long hexagonal screws complete all as specified.
Supply and laying of GI pipe 40mm bore, "light grade" ISI marked with all fittings laid in trenches complete all as specified.
S&F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to pole or any other indicated situation for loop earthing etc size 32x6mm GI strip complete all as specified.
S&F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to pole or any other indicated situation for loop earthing etc size 20x3mm copper strip complete all as specified and directed by Engr-in-Charge.
S&F low density poly ethylene pipes (LDPE) of pressure rating 6Kg/Cm2 size 40mm bore laid in trenches complete all as specified and directed.
M&L for chemical earthing complete with plate 90x60cmx5mm thick copper plate electrode buried direct in ground vertically not less than 3.15Mtr deep below ground level with top edge of the plate (earth pit not less than 2.25 Mtrs), deep below ground level with connected to copper strip of size 32x6 mm as earthing lead by means of bolt nut and brazing, check nut and washer all as directed to test point including necessary excavation and earth work in any type of strata) and providing charcoal dust 250Kgs, common salt 200 Kgs, Magnesium sulphate 100 Kgs and all around the plate 15 cm depth and wide and upto 02 Mtr height in continuous layers, balance pit will be filled with soil upto ground level including watering pipe GI medium grade of 20mm bore and 50mm bore pipe medium grade for earth strip protection upto 7.5Mtr, PCC (1:3:6) type C1 (using 20mm graded stone aggregates) chamber, cast iron chamber frame, heavy duty funnel and RCC pit cover complete all as specified.
Demolition of reinforced cement concrete of any description and in any position not other wise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified.
Removing excavated soil/ rubbish of cement concrete exc 1.5 Km but n.exc 15.00Km and depositing where directed
M&L for Hardcore of broken stone of gauge n.exc 63mm, deposited spread and leveled in layers n.exc 15cm thick watered and rammed to a true surface complete all as specified
M&L for cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete or in sub base of floors complete all as specified
M&L for cement concrete work in pavement/hardstanding of flexural strength 40 Kg per sqm cm in field using 400 Kg of cement per cubic metre, thickness of concrete 25cm or less
M&L forming construction joints 10mm wide and 30mm deep and filled with sealing compound Grade 'B' complete all as specified.
M&L forming contraction (dummy) joints 65mm deep and 10mm wide filled with sealing compound Grade 'B' complete all as specified.
S&F SFRC (Steel fibre reinforced concrete) cover and frame (heavy duty HD-20 grade & Design) of any size as per site requirement of cover and frame confirming to IS-12592, fixed in cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) complete all as specified Note : Thickness of manhole cover and frame shall be according to IS-12592 for HD-20 (Heavy Duty-20) grade and overall size of manhole cover with frame should be measured.
Supply and laying of GI pipe 25mm bore, "medium grade" ISI marked with all fittings laid in trenches complete all as specified.
Supply and laying of GI pipe 15mm bore, "medium grade" ISI marked with all fittings laid in trenches complete all as specified.
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe of 25mm bore complete all as specified.
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe of 15mm bore complete all as specified.
M&L for cutting of existing pipe and insertion of tee 25x25x25mm dia for taking branch connection. Note: Cost of tee and union is included in the above rate
M&L for Cutting trench through road/wall to a width of 20 cm and depth of 30 cm for laying GI pipe and filling back the trench with PCC 1:3:6 type C1 using 20mm graded stone aggregate complete all as specified
S&F CMRI certified LED flame proof weather proof flood light fitting 70W fixture, recommended for gas/vapour group of IIA & IIB and zone 1&2 IP 65 protection surface mounted, pre wired with all accessories complete all as specified and directed by Engr-in-Charge
S&F FLP/WP switch 16 Amp, 250V single pole ON/OFF rotary type with termination box in LM6 complete alll as specified and directed by Engr-in-Charge
S&F FLP/WP isolator 16 Amp double pole ON/OFF with termination box in LM6 complete all as specified and directed by Engr-in-Charge
Supply, laying and testing LT XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 Sq mm 2 core fixed on wall with suitable saddle and base complete all as specified and directed by Engr-in-Charge
M&L for flame proof wiring with 2 runs of 1.5 sqmm single core multistranded copper conductor FRLSH PVC insulated unsheathed cable 1100 volts grade drawn through ERW steel conduit of 20mm bore with all acessories like sockets, bends, junction boxes etc and PVC insulated copper conductor FRLSH 1.5 sqmm as continous earth wire fixed on wall. Note: 2 run of 1.5 Sqmm PVC insulated unsheathed copper conductor FRLSH and 1 run of 1.5 sqmm PVC insulated unsheathed copper conductor FRLSH and 1 run of steel conduit size of 20mm bore will be measured as a single run.
M&L for point wiring for flame proof light point controlled by one switch with 1100 volts grade 1.5 Sqmm PVC insulated unsheathed FRLSH multistranded copper conductor cable and including ERW steel rigid in stove enamelled conduit medium grade conduit of minimum 20mm dia external with wall thickness not less than 1.6mm, including all conduit accessories like bends, tees and elbows, junction boxes etc and FRLSH PVC insulated unsheathed copper conductor wire of 1.5 sqmm as continuous earth wire fixed on walls/roof/floors connected to switch complete all as directed by Engineer-in-Charge.
Excavation in trenches in soft/disintegrated rock not exceeding 1.5 metre wide and n. exc 1.50m depth for foundation etc or for shafts, wells, cesspits , man holes, pier holes etc n. exc 10 sqm on plan and getting out complete all as specified.
Excavation in trenches in soft/disintegrated rock not exceeding 1.5 metre wide and exc 1.50m depth but n.exc 03 Metre for foundation etc or for shafts, wells, cesspits , man holes, pier holes etc n. exc 10 sqm on plan and getting out complete all as specified.
S&F 2000 Ltrs capacity rotational moulded, polyethyene water storage tanks (cylindrical vertical with closed top) with threaded top mouth cover complete all as specified. Note: PVC tank shall be ISI marked and having two layers
S&F Factory made steel rolling shutters made of 1.0mm thick mild steel sheet without ball bearing, including top cover, achoring road, hasp and staple, guid channels, strike plate push pull are mannual type etc complete all as specified and directed
M & L for preparation of new steel surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
M &L for Forming jambs in cement mortar 1:6 etc. to openings(to foregoing item) including cutting, toothing and properly bonding into old work, including facing, jointing and pointing ( if necessary) to match existing plaster work and finishes complete all as specified.
M & L for providing cement concrete (1:2:4), type B-1 using 20mm graded stone aggregate as in lintels upto 1.50m clear span, cills steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parpets and railing upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering , slightly rounded or chamfered angles and throating including necessary form works etc complete all as specified.
M & L Mild steel works in band, straps, supports or stay for rain waters , wind ties ventilating pipes incl bolts if required hooks (stay) having for large gates , hook and pintle hinges,large hasp and staples , chains, hand made sliding bolts clamps, hold fasts , wall ties hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or fafters , knee piece inserts , two and three ways straps , plate washers and similar small articles conforming to grade E-165 (Fe-290) complete all as specified.
Godara Construction and General Suppliers
M.D. CONSTRUCTION CO.
M/s Pankaj Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .