Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹22.4 L+₹65,950 (3.04%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹25.8 L+₹4.1 L (18.7%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹27.5 L+₹5.8 L (26.6%)Rejected-Finance | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹29.6 L+₹7.9 L (36.3%)Rejected-Finance | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
27 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
GE 970 EWS C/o 56 APO
REPAIR AND MAINT OF EXTERNAL ELECTRIC NETWORK INCLUDING LT OH LINES, UG CABLES, CABLE JOINTS, LT POLES, INSULATOR, STAY ASSY ETC AND PERIMETER LIGHTS AND CONNECTED WORKS AT JAK LI RC UNDER GE 970 EWS
2021_MES_485056_1
GE 970 EWS-56/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE 970 EWS
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 970 EWS
₹82,000
Yes
24 Jan 2022
30 Oct 2021
29 Nov 2021
30 Oct 2021
27 Nov 2021
13 Nov 2021
60 days
Amount
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth and getting out in soft/loose soil for taking up or laying of cable complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed
Removal of surplus soil not excceed to a distance of 50M where directed at a level not exc 1.5 M above the starting point complete all as specified and directed.
Sand cushioning to underground cable with clean dry sand locally available 8cm thick before laying the cable and 15cm above the cable,stretching and testing of cable lcomplete all as specified and directed. Note : For payment purpose , punned thickness shall be measured .
Brick protection with brick well burnt locally available sub class 'B' laid over sand cushioning to cable in trenches with width of brick parallel to the length of cable complete all as specified and directed.
Taking down old unserviceable LT UG cable from any description (tranches, walls, ceilings.,etc) from various locations, including any length, supply and laying under ground LT cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 120 Sq mm, 4 core, with aluminium conductor with suitable size aluminium cable lugs and jointed in any description complete all as specified and directed. NOTE:- 1. Excavation , concrete cable protection bicks, pipe, PCC work for crossing/hard standing and sand for cushioning will be measured and paid separately. 2. Cost of aluminium cable lugs (eye lid/barrel/bottle neck type/ring type or any shape), gable gland, new nut bolt and washers of required size shall be deemed to be included in the unit rate quoted by the tenderer.
All as per item no.6 here in before but size 95 Sqmm ---ditto---
All as per item no.6 here in before but size 70 Sqmm ---ditto---
All as per item no.6 here in before but size 50 Sqmm ---ditto---
All as per item no.6 here in before but size 35 Sqmm ---ditto---
All as per item no.6 here in before but size 25 Sqmm x 4 core ---ditto---
All as per item no.6 here in before but size 16 Sqmm x 4 core ---ditto---
All as per item no.6 here in before but size 10 Sqmm x 2 core ---ditto---
Supply and fixing in repair LED flood light fitting of 120 watts with driver inside a pressure die cast alumnium housing with toughened front glass cover, IP65 degree of protection complete all as specified and directed. MAKE:-Bajaj / Havells /Wipro / Crompton Greaves.
All as per item No. 14 here-in-before but of 200 watts ---ditto--- MAKE:-Bajaj / Havells/Wipro/Crompton Greaves.
All as per item No. 14 here-in-before but of 240 watts ---ditto--- MAKE:-Bajaj / Havells/Wipro/Crompton Greaves.
Supply and fixing in repair LED street light fitting 45 watts with high efficency long life LEDs in built replaceble electronic driver complete housed in pressure die-cast aluminium alloy covered with polycarbonate cover with IP65 degree of protection complete all as specified and directed. MAKE:- Bajaj / Havells/ Wipro/ Crompton Greaves
All as per item No. 17 here-in-before but of 60 watt ---ditto--- MAKE:- Bajaj / Havells/Wipro/Crompton Greaves
All as per item No. 17 here-in-before but of 70 watt ---ditto--- MAKE:- Bajaj / Havells/ Wipro/Crompton Greaves
All as per item No. 17 here-in-before but of 90 watt ---ditto--- MAKE:- Bajaj / Havells/ Wipro/ Crompton Greaves
All as per item No. 17 here-in-before but of 120 watts ---ditto--- MAKE:- Bajaj /Havells/Wipro / Crompton Greaves
Supply and fixing in repair LED post top light fitting made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection 40 watts with high efficiency long life LEDs In-built replaceable electronic driver ccomplete all as specified and directed. MAKE:- Bajaj / Havells /Wipro / Crompton Greaves
Taking down of high mast light, hot dip galvanised mast 15/16 M high and luminairies carriage duly opening of nut & bolt at bottom with the help of Hydra/Crane for repair/replacement of old UNSV winch and steel wire ropes (as per existing) complete with ratchet, limit switches etc as per standard engineering practice to avoid falling of carrirer during raising of lowering and re-installation, testing at site and comissioning after satisfactorily repair complete all as specified and directed.
Material & labour in replacement of GI pipe bracket made out of galvanised iron tubing 32/40mm bore (dia), light grade, 1.20 M long bent to shape as per specified for fixing street light fitting including suitable size of clamps and applying two coats of aluminium paint over a coat of aluminium primer complete all as specified and directed.
Material & labour in replacement of cable junction box/ distribution board IP 65 with metric knockouts for cable entry of size 10 to 25 Sqmm x 2 core including fastening clamp with LT pole, box size : 333 x 233 x 120 mm (or nearest higher size) hinged cover with locking arrangements including with terminals TPN strip, with 01 No. MCB SP 6A complete all as specified and directed.
Supply and fix in repair mild steel cross arms channel, bracing, support, clamps etc fabricated structured steel, sections, including nuts, bolts, washers etc and cutting to required length beat to any shape drilling holes, fixed on poles or jointed by means of elect welding complete including painting with 2 coats of alumunium paint over a coat of red oxide primer after preparation of surfaces icomplete all as specified and directed.
Supply and fix or laying in trenches / on wall / poles / structure in repairs GI tubing light grade for road crossing for cable protection of the following size including necessary suitable size MS flat fixing clamps, fixing screws complete all as specified and directed.
(a) 40 mm dia
(b) 50 mm dia
(c) 80 mm dia
Material & labour in repairs for sub main wiring using FR insulated unsheathed, multistrand copper conductor FR-LS PVC cable 2 runs of size 2.5 Sqmm for phase and neutral and 1.5 Sqmm for earthing, drawn through rigid PVC conduit 20 mm dia with clamps for fixed on pole for connection from junction box to light fitting/switch complete all as specified and directed. NOTE:- Two runs of cable for phase / neutral and one run of cable for earth including conduits shall be measured and paid as one unit length.
Material & labour in repairs ACSR conductor any size from poles including stringing on LT poles complete including aluminium binding wires, jumpering, bindings at insulators etc complete all as specified and dirceted.
Disconnecting the buildings of loose overhead conductors of LT lines from insulators and restringing the same for proper sag and rewinding including aluminium winding wires, tapes etc and jumpering for any type of conductor complete all as specified and directed. (Each LT line OH conductor shall be measured as unit length.)
Supply and fixing in replacement of insulator pin type porccelain viterious, white brown or green insulator including one galvanised mild steel spindle, two galvinised washers and one GI nut 100 mm hight and 65 mm dia for 1100 Volt grade complete all as specified and directed.
Supply and fixing in replacement of insulator shackle type porccelain viterious, white brown or green insulator including one galvanised mild steel strap, washers, insulator bolts, washers and nuts for working preasure 100 mm hight and 65 mm dia for 1100 Volt 115 mm dia, section of strap (31 x5) mm dia of bolt 14mm complete all as specified and directed.
Supply and fixing in repair incl errection of steel tubuler swage poles complete with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-31 (9.0 mtr long) and shifting of conductors and insulators etc including painting the exposed portion of the pole with two coats of aluminium paint over a coat of red oxide primer and interally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer. Marking of pole number with black paint in yellow circle complete all as specified and directed.
Material & labour for PCC 1:4:8 type D2 using 40mm stone aggregate for pole foundation complete all as specified and directed.
Material & labour in repairs for earthing complete with GI earth plate 60 x 60 cm x 6 mm thick electrode and 32 x 6mm GI strip as earthing lead burried directly in ground (Earth pit not less then 2.25 m deep below ground level) with top edge of the plate not less then 1.5 m below normal ground level, connected to GI strip 32 x 6mm as earth lead by means of bolts, nuts, check nuts and washers of galvinised iron or steel all as shown in electrical plate No. 5 and including earth work, PCC pit and cover, watering pipe 20mm dia medium grade, funnel, wiremesh, charcoal dust, 40mm dia light grade protection pipe and salt etc and connected to earthing test point including necessary earth work complete all as specified and directed.
Material & labour for painting of steel tubuler pole 9.0 m long, by applying one coat of aluminium paint after scraping / brushing and cleanin the rust on pole and cross arms. Aluminium painting will be done on pole above 1.5m hight from ground level and balance 1.5 m from ground level will be painted by alternate layer of black and white enammelled paint (30 cms each) pole Nos will be written on pole by black and white in yellow circle of 150mm dia complete all as specified and directed.
Material & labour for LT heat shrinkable cable jointing kit suitable for 3.5 core 35 to 50 Sqmm aluminium cable complete all as specified and directed.
Material & labour for LT heat shrinkable cable jointing kit suitable for 3.5 core 70 to 95 Sqmm aluminium cable complete all as specified and directed.
Material & labour in repair MCCB 4 pole, current rating 400 Amp, adjustable over load and short circuit with Micro processor release setting, breaking capacity 36 kA at 415V, 50Hz complete ll as specified and directed. MAKE:-L&T/Legrand/Schenedier/HAVELLS
All as per item No. 44 here in before but 4 pole 250 A, having breaking capacity 36 kA, ---ditto---
All as per item No. 44 here in before but 4 pole 200 A, having breaking capacity 36 kA, ---ditto---
All as per item No. 44 here in before but 4 pole 160 A, having breaking capacity 36 kA, ---ditto---
All as per item No. 44 here in before but 4 pole 125 A, having breaking capacity 36kA, ---ditto---
All as per item No. 44 here in before but 4 pole 100 A, having breaking capacity 36 KA, ---ditto---
All as per item No. 44 here in before but 4 pole 100 A, having breaking capacity 16 KA, ---ditto---
All as per item No. 44 here in before but 4 pole 63 A, having breaking capacity 25 KA, ---ditto---
BLANK
BLANK
BLANK
Material & labour for PCC 1:2:4 type B-1 using 20mm graded stone aggregate including use and waste of form work for pole coping / any description complete all as specified and directed.
Material and labour in repairs for stay assembly complete with all section such as stay plate, stay clamps, stay brackets with 16mm dia stay rod and MS stay plate 230mmx230mm complete all as shown in electrical plate No 1 of SSR Part-I complete all as specified and directed NOTE : Loop insulator, excavation and concrete work will be measured and paid separtely.
Material and labour as in repairs for stay strand size 7/4 mm complete all as specified and directed
Material and labour as in repairs loop type insulator vitreous porcelian white, brown or green of size 65x90 mm overall dimension and 16mm clearance of hole complete all as specified and directed
Supply and fixing PVC line spacer (Separator) of superior quality of 4 way spiral type for three phase over head conductor complete all as specified and directed
Supply and fixing PVC line spacer (Separator) of superior quality of 6 way spiral type for three phase over head conductor complete all as specified and directed
Taking down unserviceable perimeter/security/street /highmast/ flood light in JAK LI RC area comprising various types Light fittings viz. HPSV, HPMV, MH, CFL, LED Fitting of various size/capacity mounted on Poles/Walls/High mast after disconnecting electric supply and sealing the cable ends for carrying out repairs to find out defective/taking out unserviceable Parts such as Tube Rod, Lamp, Choke, Starter, Capacitor, Lamp Holder, Bipin Holder, driver etc. and repairing by changing the defective parts including lowering and raising of high mast lights luminaires carriage, minor repair to Cable Connection /Loose Connection/ necessary cleaning the Bowl/ Cover of Security Light providing with Junction Box Cover, screws, Nut & Bolts and Insulation tape to insulate the LT Joint, etc to make the fitting fully functional to the entire satisfaction of Engineer-in-Charge and testing on completion complete all as specified and directed.
NOTES :- (a) The supply of items capacitor, Ignitor, Holder, Lamp, HPMV/HPSV/MH/ LED Fitting Electronic Driver, PVC insulated Aluminium/Copper Conductor Cable for connecting Street/Security Light Fittings, etc shall be measured and paid for separately under respective item as supply only hereinafter . The cost of fixing of item these items shall deemed to be included in the unit rate of tem No 61 quoted by the contractor. The cost of taking down of fittings shall deemed to be included in the unit rate of item no 61 quoted by the contractor. (b) Necessary T&P, Safety Belt, Aluminium Ladder, transportation etc reqd for repair/maint of perimeter/security/street lights shall be provided by the contractor without any extra cost to the department and nothing extra shall be admissible on this account. (c) The quoted unit rate shall deemed to be inclusive of attending any breakdown . The contractor shall attend the complaint within 24 hours of intimation of Engineer-in-Charge/JE.The complaints shall be attended by qaulified manpower .Fault shall be intimated through Telephone/ SMS to the contractor or his authorised representative. (d) The contractor shall attend the complaints 24 hours and if the contractor is not rectify the complaint , penalty shall be charged as given below :- (i) Upto 06 Hours- NIL (ii) Exc.06 and upto including 12 hours - Rs 200.00 per complaint (iii) Exc.12 and upto including 24 hours - Rs 400.00 per complaint (iv) Subseqently for 24 hours - Rs 500.00 per complaint
Material and labour in repair earthing complete with GI earth plate 60x60cmx6mm thick, burried directly in ground (Earth pit not less then 2.25 metres deep below ground level) with top edge of the plate not less then 1.5 metre below normal ground level, connected togalvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron as earthing lead or steel all as shown in electrical plate No.5 and incl earth work, PCC pit and RCC cover, watering pipe 20mm dia medium grade, funnel, wiremesh, charcoal dust, 15 mm dia light grade protection pipe and salt etc and connected to earthing test point incl necessary earth work complete all as specified and as directed.
Supply only electronic driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 120 Watt, complete all as specified and as directed.
All as per item no 64 above but for LED Light Fitting of capacity 100 Watt- ditto--
All as per item no 64 above but for LED Light Fitting of capacity 60/72/75 Watt -ditto--.
All as per item no 64 above but for LED Light Fitting of capacity 30/45 Watt- ditto--
Supply only PVC insulated, PVC Sheathed flat twin core cable with stranded aluminium conductor of size 2.5 sqmm complete all as specified and directed. Make: Finolex/ Polycab/ Havells
Supply and fixing of digital voltmeter 0 to 500 volts 96 x96mm flush type in LT Panels incl taking out the old unserviceable complete all as specified and as directed.
Supply and fixing of digital ammeter range as per existing 96 x96mm flush type in LT panels incl taking out the old unserviceable complete all as specified and as directed.
Supply and fixing of LT current transformer ratio from 200/5 Amps or 100/5 or 400/5 in LT panels incl taking out the old unserviceable complete all as specified and as directed.. Make : L&T.
Supply and fixing indicator assembly (RYB) LED type in LT panel boards incl taking out the old unserviceable complete all as specified and as directed.
Material & Labour PCC 1:3:6 type C 2 using 40 mm graded stone aggregate for filling of pole & stay complete all as specified and directed.
Material & Labour for galvanised steel wire 4 mm dia to be stringed as continuous earthing wire on over head LT lines including taking down the old rusted earth wire complete all as specified and directed.
Supply and fixing in repair 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 01 metre apart including 4 mm dia GI suspension wire one twin core cable flat or circular stranded conductor of size 10 sqmm complete all as specified and directed.
Material & Labour for trimming of tree branches touching or leaning over overhead power lines of one span 2 to 5 span in same pole will be measure as one unit) and removing of cut tree branches from the site complete all as specified and directed.
Supply and fixing of ACB Four pole 800Amps 35 KA capacity 415V 50Hz with adjustable thermal and magnetic relay incl taking out the old unserviceable complete all as specified and as directed. (Make of ACB's-L&T/Havells/Siemens/Standard/C&S)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .