Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹40.6 L+₹17,330.30 (0.43%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹45.4 L+₹5.0 L (12.3%)Rejected-Finance JAISALMER | JAISALMER | RAJASTHAN | 342310 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹49.7 L+₹9.2 L (22.9%)Rejected-Finance 1286 TOTA RAM KI DHANI JAISALMER RAJ 345001 | JAISALMER | JAISALMER | RAJASTHAN | 345001 | L4 | Rejected-Finance Not being lowest |
Tender Value
₹45.3 L
EMD Value
₹90,500
Closing Date
12 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Army Jaisalmer
GE Army Jaisalmer - 345001
SPL REPAIR OF RANAUTAR ASCON NODE BLDG NO P-160, P-161, P-162, P-163, P-164 AND ROLLING SHUTTER DAMAGE DUE TO HEAVY STORM AT BLDG NO. P-1777, P-1778 REPAIR BAY OF CERTAIN UNITS AT MIL STN JAISALMER
2024_MES_666326_1
8369/24-25/E8
Open Tender
Civil Works
Item Rate
180 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Army Jaisalmer
₹90,500
Yes
28 Nov 2024
18 Jul 2024
14 Sept 2024
18 Jul 2024
12 Sept 2024
1 Aug 2024
Amount
PHASE-I
S&F steel rolling shutter (thickness of lath 1.25mm thick) with gear operated type with chain wheel and hand chain as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated including taking down existing rolling shutter shutter of any description complete all as specified & directed by Engineer-in-charge.
M&L for preparation of new steel surfaces and apply two coats of synthetic enamel paint over existing shop coat of primer complete all as specified & directed by Engineer-in-charge.
PHASE-II
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in hard/dense soil complete all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with hard/dense soil complete all as specified & directed by Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-Charge.
Demolition of stone slab & tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified & directed by Engineer-in-Charge.
M&L Granite (of any type) tile 16 to 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing laid on complete all as specified & directed by Engineer-in-Charge.
M&L Granite (of any type) tile 16 to 20mm thick machine cut,in skirting/dado laid over cement screed bed and jointed with cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified & directed by Engineer-in-Charge.
M&L for Machine cut kota stone slab flooring 16-22mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over and including screed bed 15 mm thick in CM 1:6 complete all as specified and directed by the Engineer in charge.
M&L Kota stone slab 16-22mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over and including backing coat 10mm thick in CM 1:4 complete all as specified and directed by the Engineer in charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premise complete all as specified and directed by Engineer-in-charge.
Demolition of cement concrete (un reinforced) in ground floors and pavings n.exc 15 cm thick (below or above ground level) & removing rubbish out side MD land all as directed by Engineer-in-charge.
M&L for 75 mm thick plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in sub base of flooring/ hard standing & finished the surface even & fair without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for 50 mm thick plain cement concrete (1:3:6) type C-1 (using 20 mm graded stone aggregate) laid in alternative bays as in plinth protection including finishing the surface even & fair & filling the joints with mastic filling i.e one part of bitumen 85/25 and 3 parts of sand by weight all as specified & directed by Engineer-in-Charge
M&L for 25mm thick plain cement concrete (1:2:4) type B-0 (using 12.5mm graded stone aggregate) as in subbase of floors & finishing the surface even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for Non Skid ceramic tiles Exterior Grade 300x300x10mm thick jointed in neat cement slurry and pointed in coloured cement as in floor laid over and including 15mm thick screed bed or bedding layer of cement mortar in CM (1:6) for laying floor finish complete all as specified and directed by the Engineer in charge.
M&L non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for glazed ceramic colour tiles 350x250mmx7mm/ 450X350X7mm thick, in vertical surfaces etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 10mm thick backing coat in CM (1:4) complete all as specified and directed by the Engineer in charge.
M&L for vetrified ceramic coloured tiles 9 to 10 mm thick area of each tile not exc 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement over 15mm thick screed bed in CM (1:6) provided with 3mm thick joints accomplished by providing PVC spacers and joints filled with epoxy filling complete all as specified and directed by the Engineer in charge.
M&L for vetrified ceramic coloured tiles 9 to 10 mm thick area of each tile not exc 0.36 sqm in Skirting/dado over 10mm thick backing coat provided with 3mm thick joints accomplished by providing PVC spacers and joints filled with epoxy filling complete all as specified and directed by the Engineer in charge.
S&F in repair soap dish stanless steel to walls complete all as specified and directed by the Engineer in charge.
S&F in repair, 75mm bore PVC (SWR) single socketed in any length with rubber ring joints & fixed to walls complete all as specified and directed by the Engineer in charge.
S&F in repair, 110mm bore PVC (SWR) single socketed in any length with rubber ring joints & fixed to walls complete all as specified and directed by the Engineer in charge.
S&F in repair, 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified & directed by Engineer-in-charge.
S&F in repair, PVC (SWR) bends of 75mm bore setting & jointing with solvent cement complete all as specified & directed by Engineer-in-charge.
S&F in repair, PVC (SWR) bends of 110mm bore setting & jointing with solvent cement complete all as specified & directed by Engineer-in-charge.
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches complete all as specified and directed by the Engineer in charge.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches complete all as specified and directed by the Engineer in charge.
S&F in repair, PVC (SWR) cowl of 75mm bore setting & jointing with solvent cement complete all as specified & directed by Engineer-in-charge.
S&F in repair, PVC (SWR) cowl of 110mm bore setting & jointing with solvent cement complete all as specified & directed by Engineer-in-charge.
S&F for PVC (SWR) floor trap 75mm diameter of outlet, plain with grating including jointing with solvent cement incl jointing to waste pipe fixed in plain cement concrete (1:2:4) type B1 complete all as specified and directed by the Engineer in charge.
S&F for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed by the Engineer in charge.
S&F in repair, 15 mm bore, fancy type, chromium plated, bib tap, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & directed by Engineer-in-charge.
S&F in repair 15 mm bore pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' & 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified & directed by Engineer-in-charge.
S&F in repair, tubular towel rail brass chromium plated, 20mm dia, D type, 60cm long between flanges fixed with chromium plated brass screws complete all as specified & directed by Engineer-in-charge.
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified & directed by Engineer-in-charge.
S&F in repairs vitreous china wash hand basin white 550x440mm of size incl cutting for and pinning in ends of brackets or erecting stand incl brackets PVC waste pipe 15mm PVC connection pipe and cuppling of suitable size complete all as specified & directed by Engineer-in-charge.
S&F 15 mm bore dia steel water tubing medium grade galvanised with and including necessary all fittings and fixtures complete fixed to walls and ceilings or laid in floors etc including taking down of old existing pipe complete all as specified & directed by Engineer-in-charge.
S&F 20 mm bore dia steel water tubing medium grade galvanised with and including necessary all fittings and fixtures complete fixed to walls and ceilings or laid in floors etc including taking down of old existing pipe complete all as specified & directed by Engineer-in-charge.
S&F in repairs vitreous china urinals with and including urinal spreader, Half stall (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing complete all as specified & directed by Engineer-in-charge.
S & F in repair Vitreous china wash down water closet pan(Pedestal pattern), white (EWC) with necessary P/S Trap and fixed in repairs including jet spray and seat cover complete all as specified & directed by Engineer-in-charge.
S&F in repair vitreous china squatting pan orissa pattern complete of size 580 x 440 mm white with intagral foot rest and making good to the floor complete all as specified & directed by Engineer-in-charge.
S&F in repair PVC low level white flushing cistern syphonic action type 10 ltrs capacity incl flush pipe 32 mm dia incl PVC connection 450 mm long complete all as specified & directed by Engineer-in-charge.
S&F in repair PVC connection 15mm size with PTMT nuts and polythene washers of 450mm length complete all as specified & directed by Engineer-in-charge.
S&F in repair PVC down take waste water pipe for WHB of size 32 mm dia and 60 cm long complete all as specified & directed by Engineer-in-charge.
S&F in repair Swivel shower rose 75mm size with arm 195mm long with bend of 45 degree with flange of PTMT any colour complete all as specified & directed by Engineer-in-charge.
S&F in repair sheet glass shelf assembly consisting of 5.5 mm thick sheet glass of size 12 cm wide with CP bracket guard and railing 60 cm long complete all as specified & directed by Engineer-in-charge.
S&F in repair chromium plated Angle valve 15mm complete all as specified & directed by Engineer-in-charge.
S&F in repair 15mm fancy type, chromium plated with long shank and cup (concealed type Stop valves, cast copper alloy screwed pressure, with crutch of butterfly handle, screwed both ends for iron pipe for unions complete all as specified & directed by Engineer-in-charge.
Taking down shutters of any description not exc 1 Sqm each complete all as specified & directed by Engineer-in-charge.
Taking down shutters of any description exc 1 Sqm but not exc 2 Sqm each complete all as specified & directed by Engineer-in-charge.
Taking down chowkat (without taking of shutter from the frame) not exc 1.5 sqm each including making good the disturbed surface in PCC 1:2:4 type B0 or CM 1:3 and white wash and cement base paint finished complete all as specified & directed by Engineer-in-charge.
All as per item No 51.00 above but exc 1.5 sqm and n exc 4 sqm each
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified & directed by Engineer-in-charge.
S&F Pressed steel frames of size 125x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. incl filling of hollow portion with complete all as specified & directed by Engineer-in-charge.
S&F, 35 mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc size of members of shutters as specified in SSR Part-I, section 8, clause 8.24 (a) complete all as specified & directed by Engineer-in-charge.
S&F, 35 mm thick second class hard wood factory made plain, framed, panelled shutters, with lock rail and panel of 9mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and Style as per IS:1003 (Part-1), kiln seasoned and chemically pressure treated complete all as specified & directed by Engineer-in-charge.
S&F Galvanized mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned stacks, or galvanized wire staples complete all as specified & directed by Engineer-in-charge.
M&L Preparation of New or previously untreated wood and wood based surfaces of any description, .exc 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer complete all as specified & directed by Engineer-in-charge.
S&F Steel windows with side hung shutters including projecting type hinge with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified & directed by Engineer-in-charge.
M&L for preparation of new or previously untreated steel surface of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red- oxide, zinc chrome primer complete all as specified & directed by Engineer-in-charge.
S&F for aluminium powder coated (minimum thickness of powder coating 50 micron) window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified & directed by Engineer-in-charge.
S&F figured glass pin head type 3mm thick ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified & directed by Engineer-in-charge.
S&F 150mm long aluminium anodized, barrel tower bolt of extruded section complete all as specified & directed by Engineer-in-charge.
S&F 150 mm long Aluminium handles, cast type, anodised complete all as specified & directed by Engineer-in-charge.
S&F, 100mm size, butt hinges, medium weight, cold rolled mild steel including necessary welding if required all as specified & directed by Engineer-in-charge.
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy all as specified & directed by Engineer-in-charge.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with single piece extruded PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement of single piece extruded PVC profile for top rail, lock rail and bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement complete all as specified & directed by Engineer-in-charge.
Taking down cement plaster of any description on stone or brick walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-charge.
M&L for rendering 15mm thick on stone surfaces or other than fair faces of brick work or on one side of lathing in cement mortor (1:6), finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for rendering 15mm thick in cement mortar C:M (1:4) in two layer (First coat 10 mm thick and second 5 mm thick floating coat) using water proofing compound @ 3% by weight of cement in second coat and finished fair and even complete all as specified and directed by Engineer-in-charge. Note :- WPC will be measured and paid separetly.
M&L for rendering 5 mm thick in CM (1:4) on fair faces of concrete surfaces as in ceiling finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L prepration of new plaster surfaces of wall and apply two coat of distemper oil emulsion over a coat of primer including apply putty for uniform smooth surface of wall complete all as specified and directed by Engineer-in-charge.
M&L for preparing new plastered or unplastered surfaces and applying three coats of white wash on ceiling all as specified & directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over one coat of primer including apply putty for uniform smooth surface of wall complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old decorated existing surfaces including cornices, plasterd or un plasterd surfaces by brooming down or steel wire brushing moulds, moss efflorescent salt and trading oil and gresy spots and applying one coat of white wash on ceiling complete all as specified & directed by Engineer-in-charge.
M&L for complete removal of the existing treatment on walls scrapping and washing including making good to the surfaces and applying two coat of distemper oil emulsion over a coat of primer and application putty for making uniform surface of wall complete all as specified & directed by Engineer-in-charge.
M&L for preparation of old decorated plastered surfaces of walls and applying one coat of cement base paint complete all as specified & directed by Engineer-in-charge.
M&L for preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as directed by Engineering in charge.
M&L for preparation of old painted wooden surfaces of any description not other wise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as directed by Engineer-in-Charge.
S&F, 3mm thick, sheet glass ordinary quality and glazing with oil putty in squares not exceeding 0.50 sqm in each panes and including hacking out old broken glasses (any thickness, size, quality or description) from steel/wooden frames, stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified & directed by Engineer-in-charge.
Welding in repairs exc 2.5cm but not exceeding 5cm in length (thickness of metal to be welded not exc 6mm) including cleaning preparing the surface and holding the member in true position complete all as specified and directed by Engineer in charge.
S&F steel ventilators with top hung shutters fitted with box type hinges including MS peg stays, MS handle and glazing bars dovetailed or welded for receiving glass including painting with one shop coat of zinc chromate primer,and cutting holes in wall for fixing the window lugs in PCC 1:2:4 type B1 using 20mm graded aggregate and making good the disturbed surfaces in CM (1:3) and applying two coats existing wall finishes to match with existing colour including taking down existing unserviceable window/ ventilators of any description complete all as specified and directed by Engineer-in-charge. Note : The rates quoted are inclusive of making good all the disturbed surfaces to match with the adjoining surfaces and necessary scaffolding etc up to 4th floor.
Supply only integrated water proofing compound complete all as specified & directed by Engineer-in-charge.
Demolition of Brickwork or stone/ boulder masonry, built in Cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles etc complete all as specified & directed by Engineer-in-charge.
M&L squared rubble walling Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) complete all as specified & directed by Engineer-in-charge.
M&L sand stone slabs 5cm thick in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc. n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:2 or cement mortar 1:4. complete all as specified & directed by Engineer-in-charge.
S&F aluminium (Die cast) door closer hydraulically regulated designation No. 3, universal type, suitable for door shutter of 851 mm to 1000mm in width and of weight between 61 to 80 Kg complete all as specified & directed by Engineer-in-charge.
Taking down all loose plaster and concrete if any in RCC columns, Chajjas, beams,slabs or any other type of RCC members,removing all loose ruts/scale from reinforcement etc by using wire brushes ,sand paper or any other chemicals, applying a coat appoxy coating on old reinforcement, tying IRC fabric of size 75x75mm of 3mm dia and binding with mild steel wire annealed with exsting reinforcement and applying cment slurry uniformaly to exposed surfaces and gunniting using CM 1:3 avg thickness of gunniting not less then 30mm and finishing the surfaces with 10mm thick rendering in CM 1:4 finished even and smooth with out using extra cement and removing the debris from the site complete all as specified & directed by Engineer-in-charge.
M&L providing and fixing additional steel bar in various structural elements like column, beams and Slab etc. including drilling ,bending and fixing the bars tying with preleft binding wires etc. complete Steel provided on the basis of 1% of volume of concrete .Anchoring reinforcement bar in exisiting RCC member in holes of minimum 10d depth for 8 to 12 mm dia complete all as specified & directed by Engineer-in-charge.
M&L Flush cutting of RCC chajjas, fins with reinforcement up to 150 mm depth by norms of Rcc mechanical cutting machine complete all as specified & directed by Engineer-in-charge. Note for Ser Item No. 92 to 94 (i) Rate quoted by the Contractor shall deemed to inclusive of scafolding. (ii) Content shall submit 10 years guarantee for these items at the Rate of 2.51 of the amount of these items.
S&F anodised aluminium snap grid frame work 605x605mm for false ceiling and hangers 6mm dia, GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fastener 12.5mm dia 40mm long including 12 mm Gymsum board, exterior grade with screws including dismantling of Ceiling Board of any description and any thickness including Cover Fillets, Cornices, etc complete all as specified and as directed. Note :- (i) Main tee, cross tee shall be 35x25x1.5mm & 25x25x1.5mm respectively. Angle at end all along the walls shall be 40x25x2mm. (ii) Rate quoted by the contractor shall deemed to inclusive of frame work & ceiling board complete.
S&F 1000 ltrs capacity white colour three layer rotational moulded polythene water storage tank (Cylinderical vertical with closed top) hoisted and fixed in position with 20mm bore dia ball brass valves high pressure, with polythene float and flynut screwed for iron pipe or brass ferrule including dismantling of existing tank with float valve complete all as specified & directed by Engineer-in-charge.
S&F 18/19mm thick pre-laminated particle board, exterior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination alround 6mm th teak fillets fixed in kitchen CB or pelmet including dismantling of existing unserviceable board of any description complete all as specified & directed by Engineer-in-charge.
M&L for 2nd class hard wood fillets square, rectangular as in lippings fixed with nails of area exc 3 Sqcm but n.exc 6 Sqcm complete all as specified & directed by Engineer-in-charge.
S&F 40mm width of flaps (when open) continuous (piano) hinges, mild steel bright finish or electro galvanised fixed to wooden or angle iron frame complete all as specified & directed by Engineer-in-charge.
S&F 40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, bright finished complete all as specified & directed by Engineer-in-charge.
S&F 100 mm size hasp and staple, safety type, aluminium anodized with mild steel hinge pin including bolt to hinge plate and fixed with screws including taking down existing hasp and staple complete all as specified & directed by Engineer-in-charge.
Dismantling wrought iron or mild steel work of any description specifically provided for gates, staircase railings, framed truss etc complete all as specified & directed by Engineer-in-charge.
S&F Pre-painted galvalume aluminium zine coating GI based corrugated steel sheeting 0.50mm thick any colour having tensile strenght 550Mpa in roof coverings fixed with self tapping screws including dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified & directed by Engineer-in-charge. Note :- (i) The fixing of Galvalume roof sheet as in sun-shades & in walls at certain places to be fixed by making of grooves cutting 75mm minimum with making good surface are inlcuded in the cost of item itself. No extra cost shall be paid for the same. (ii) The pattern and design of sunshades to be fixed as per directions of Engr-in-charge.
S &F Rolled sections Fe-410- W(Gde- E-250) quality- Bas in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified & directed by Engineer-in-charge.
Dismantling/Demolition of existing roof terracing of cement/brick concrete (un-reinforced) and existing water proofing treatment of any thickness in any position on top of roof of building, cleaning surface of roof with brush/mechanical brush and with water throughly to romove all dust/dirt and loose particles to expose bare concrete roof slab and romoval of rubbish/demolished material out side MD land complete all as specified & directed by Engineer-in-charge. Note : Demolition should be done by chiselling and will include removal of all the filled up earth over the roof and re-filling of removed earth after new roof treatment.
M&L for PCC (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) as in levelling padding course over RCC roof surface including rounded or chamferred on edges etc., with approved water proofing compound all as per manufacturer's instructuions on the roof surface to achieve requisite slope complete all as specified & directed by Engineer-in-charge. (Note :- Supply only water proofing compound shall be measured & paid separately).
M&L for providing 3 mm thick APP modified memberane over RCC roof with the following specifiations :-
(a) Cleaning existing surface properly. (b) Apply oil bound bitumen primer @ 0.40 lit/Sqm manufactured by the same agency as that of APP with a density of 0.87 -0.89 Kg/Lit at 25 Degree Centigrade on the prepared dry roof surface. (c) Providing and Laying APP modified water proofing membrane reinforced with non wooven polyster matt with physical propertities as under :- (i) Membrane weight >3.6 Kg/Sqm. (ii) Net wooven polyster weight >160 gm/Sqm (iii) Softening point of membrane > 150o C (iv) Joint Tensile strength Longitudiual > 650 Sq Cm at 230o C & Transverse > 450/ Sq cm (v) Tear strength - Longitudual > 300 N & Transverse > 250 N Direction (vi) Elongation > 30 % (vii) Impermeability under water pressure > 3 Kg/Sq cm Note:- APP membrane shall be laid using butane torch by Torch application with minimum 10 cm side overlap and 15 cm end lap. The laying of membrane shall be got done through authorised applicator of manufacturer of membrane.
S&F in repair sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified & directed by Engineer-in-charge.
S&F in repair stainless steel plate rack of size 31x30x10 inchs of approved make by Engr-in-charge fixed to wall including all fittings and fixtures complete all as specified & directed by Engineer-in-charge.
S&F Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete all as specified & directed by Engineer-in-charge.
S&F galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) including taking down existing unserviceable barbed wire of any description complete all as specified and directed by Engineer-in-charge.
S&F in repair anodised aluminium alloy Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified and directed by Engineer-in-charge.
Taking down carefully surface aluminium or copper point wiring with PVC casing-caping (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc and making good disturbed surfaces complete all as specified and directed by Engineer-in-charge.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including MCBs any type and capacity making good the disturbed surfaces to match with the existing finishes complete all as specified and directed by Engineer-in-charge.
Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed by Engineer-in-charge.
M&L Point wiring used approved colour coding as per IS (Red, Black and Green) for single phase circuits), with multi-stranded copper conductor 1.5 sqmm nominal cross -sectional area, single core, PVC insulated and unsheated FRLS cable 1100 volts grade, ISI 694 marked with valid CML No. in and including medium grade, PVC concealed conduit MMS, ISI marked of dia not less than 20 mm and conduit accessories conceled in wall/roof/floor etc, ISI marked with valid CML No. (IS-9537 - 1983 for condits and IS : 3419 - 1976 for conduit accessories) with terminated to new pressed flush metal boxes readily available cover with outer plates inner plates et, suitable for mounting modular type switches, socket fan regulator etc PVC insulated multistanded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :- Note : Modular switch and socket shall be measured and paid separately.Make: Polycab/Havells
One light point controlled by one switch
One ceiling/exhaust fan point controlled by one switch
one bell/buzzer point controlled by one push botton.
One socket outlet 6 amp controlled by one switch on the same board with other switches.
All as per item No 116.00 here in before but with copper conductor cable of nominal class area 2.50 sq mm for phase ,neutral & earth for One 2/3 pin socket outlet 5Amps on independent board.
All as per item No 116.00 here in before but with copper conductor cable of nominal class area 4.0 sq mm for phase, neutral & earth for power socket point 15 A.
S& F modular switch one way 6A, 1 module complete all as specified & directed by Engineer-in-charge.
S&F modular socket 6A-2/3 pin combined 2 module complete all as specified & directed by Engineer-in-charge.
S&F modular switch socket combined 6A/16A , 6 pin, 3 module complete all as specified & directed by Engineer-in-charge.
S&F step type modular fan regulator 120W -2 module ISI Marked with valid CML No complete all as specified & directed by Engineer-in-charge.
S&F Ceiling rose, three terminals PVC/polycorbonate, isolated body complete all as specified & directed by Engineer-in-charge.
S&F in repair bell push flush type 5 Amps complete all as specified & directed by Engineer-in-charge.
S&F in repair bell AC single pole Ding Dong type 230 volt complete all as specified & directed by Engineer-in-charge.
S&F vertical DBs TPN 4 way 415 V double door powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 250 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required,suitable for TP/FP MCCB as incomer including MCCB 160 A , and with SP/TP MCCB's as incoming MCCB FP 160A, 25 KA complete all as specified & directed by Engineer-in-charge.
S&F vertical DBs TPN 4 way 415 V double door powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 250 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required,suitable for TP/FP MCCB as incomer including MCCB 100 A , and with SP/TP MCCB's as incoming MCCB FP 100A, 25 KA complete all as specified & directed by Engineer-in-charge.
S & F for MCB DB SPN 12 way double door IP 43 complete prewired including Bus Bar etc suitable for operation on 240 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified & directed by Engineer-in-charge.
S & F for MCB DB SPN 8 way double door IP 43 complete prewired including Bus Bar etc suitable for operation on 240 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified & directed by Engineer-in-charge.
S & F for MCB DB SPN 4 way double door IP 43 complete prewired including Bus Bar etc suitable for operation on 240 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified & directed by Engineer-in-charge.
Supply and fixing 415V 10 KA 'C' curve miniature circuit breaker (MCB) of tripple pole and neutral rated capacity TPN 63 To 100 Amps current carrying capacity in the DB complete with connection testing and commissioning complete all as specified & directed by Engineer-in-charge.
Supply and fixing MCB's single pole and neutral 40 to 63 Amps, 240 Volts,10 KA rapturing capacity 'C' curve complete all as specified & directed by Engineer-in-charge.
Supply and fixing MCB's single pole 10 Amps to 32 Amps, 240 Volts,10 KA rapturing capacity 'C' curve complete all as specified & directed by Engineer-in-charge.
M&L for submain wiring with approved colour code/as per IS (Red,black & green for three phase) concealed conduit circuit with four single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 10.00 Sqmm (FRLS) in conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 10.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified and directed by Engr-In-Charge. Note :- Four runs of 10.00 Sqmm cable & one run of 10.00 Sqmm cable as earth wire and one run of PVC conduit shall be measured and paid as one unit length.
M&L for submain wiring with approved colour code/as per IS (Red,black & green for single phase) concealed conduit circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 10.00 Sqmm (FRLS) in conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 10.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified and directed by Engr-In-Charge. Note :- Two runs of 10.00 Sqmm cable & one run of 10.00 Sqmm cable as earth wire and one run of PVC conduit shall be measured and paid as one unit length.
M&L for submain wiring with approved colour code/as per IS (Red,black & green for single phase)concealed conduit circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 6.00 Sqmm (FRLS) in conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 6.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified and directed by Engr-In-Charge. Note :- Two runs of 6.00 Sqmm cable & one run of 6.00 Sqmm cable as earth wire and one run of PVC conduit shall be measured and paid as one unit length.
S&F triple pole and enclosure with a three pin and earth plug and socket complete with 63 Amp triple pole MCB as incomer 415 V complete all as specified & directed by Engineer-in-charge.
S&F single pole and enclosure with a two pin and earth plug and socket complete with 20 Amp single pole MCB as incomer 240 V complete all as specified & directed by Engineer-in-charge.
S&F bldg security light fittings wall mounted led Light of Capacity 36 Watt with inbuilt driver having pressure die cast Aluminum housing, IP-66 Having Efficiency of ≥ 100 Lumens/Watt, Operating voltage 120 – 270 Volts, P.F ≥ 0.95, T.H.D < 10 % , both fixture /luminaire & driver must have separate BIS marked registration and it must be mentioned clearly on fixture & as well as on driver also suitable for 30 to 40 mm O.D mounting Pipe and connecting with three core copper flexible cable of size 1.50 Sq mm including taking down existing unserviceable light fitting of any description complete all as specified & directed by Engineer-in-charge.
S&F bracket of GI pipe light grade of 40mm dia, 1.2 meter in length clamps made of FI 40 mm x 6mm incl nuts, bolts & washers, painting and including taking down existing bracket complete all as specified & directed by Engineer-in-charge.
S&F surface and wall mounted LED tube light along with fixture, 4 ft, 20 W, extruded aluminium housing provided for efficient heat disspation with polycarbonate, operating voltage 240 V, 50HZ, AC supply and operating tempureture 0 to 50 C, power factor >0.9, lumen output > 2000 and provision of new 3 core multistanded copper conductor of size 23/0.193 from ceiling rose to fitting with white colour flexible pipe including taking down existing unserviceable light fitting of any description complete all as specified & directed by Engineer-in-charge.
Supply and fixing of recessed/ceiling mounted down lighter with CRCA housing with high bright LED, idealy suited for low ceiling areas Brilliance 36 watt LED, size 2ft x 2ft The product features color tuning from 3000 K to 6500 K, necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with white color flexible pipe including taking down existing unserviceable light fitting of any description complete all as specified & directed by Engineer-in-charge.
S&F LED tube light fitting 10 watt tube LED Neutral white in colour, 600 mm in length wall mounted LED batten, extruded aluminium heat shink provided for efficient heat dissipation & integrated electronic driver, optic diffused type including all electric connection with whilte flexible cord 1.50 Sqmm 3 core as required including taking down existing unserviceable light fitting of any description complete all as specified & directed by Engineer-in-charge.
S&F for LED post top lantern/gate Light 40 watt light fitting made of cast aluminium spigot housing with decarative opal acrylic diffuser with IP 65 protection complete with all accessories including removal of old unserviceable complete all as specified & directed by Engineer-in-charge.
Supply and fixing of PVC insulated copper conductor 2.5 sq mm 3 core in PVC conduit medium grade in ground/surface with necessary fixing arrengment and connecting items complete all as specified & directed by Engineer-in-charge.
S&F ceiling fans with three blade, down rod, accessories 230 V, 1200 mm sweep including necessary connecting cable complete all as specified & directed by Engineer-in-charge. Note :- The rate quoted by the contractor shall deemed to inclusive of suitable size/ length of down take rod and length of cable as per site requirement.
S&F Steel body heavy duty exhaust fans AC single phase 230/ 240 V of size 450 mm sweep with louver complete all as specified & directed by Engineer-in-charge.
Supply & fix water heater storage type (Geyser) vertical type, inner container of capacity 25 ltrs, electrically operated, AC 230 Volts, including 4 Nos of fashner nuts required suitable size fixed in brick wall BEE 5 star rated complete all as specified & directed by Engineer-in-charge.
Cutting holes in wall with mason for making opening suitable for fixing of 450 mm exhaust fan and making good as per existing surface of wall complete all as specified & directed by Engineer-in-charge.
Taking down ceiling fan/ exhaust fan of any sweep, dismanting blade and including preparation, filling cavity applying one coat of synthetic enamel paint by spraying with machine, re-assembling the fan body to fan and re-fixing in its original position or any other position complete all as specified & directed by Engineer-in-charge. Note :- Rate quoted by the contractor shall deemed to inclusive of replacing of quarter pin, nut bolt with check nut, rubber real etc.
Taking down storage geyser of any capacity after disconnecting electrical connection from existing socket, removing the bolts and nuts from wall and disconnected inlet and outlet water connection including preparation of surface and apply synthetic enamel paint by spraying with machine including filling cavity with filler one coat and including refixing the geyser it's original location after repair/replacing the unsv items like heating element, thermostat, PVC connection pipe of hot & cold type changing of outer body with its inner tank if found unservicable, making Geyer serviceable in all respect complete all as specified and directed by Engineer -in-Charge. (Note :- Rate Quated by Contractor shall be inclusive for replacing all unsv item like Sefty valve, Heating element, Thermostat, PVC Connection pipe of hot & cold type, Changing of outer body with its inner tank ete).
M&L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground level connected to galvanized iron wire 4 mm dia as earthing lead up to Panel /DB BOX as per site requirement by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection including test point terminal cover the earhing hole by PCC chamber and GI cover and testing on completion and including taking down existing earthing complete all as specified & directed by Engineer-in-charge.
M&L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with copper pipe of dia 40 mm bore and thickness of pipe not less than 1.80mm 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground level connected to copper strip 32x6mm as earthing lead up to 7.5 mtr by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection connected to electrical equipment and earthing test point , earth dolly and earth chamber as shown in elect plate No 2 of SSR Pt-I including all necessary earth work, excavation, earth chamber with PCC 1:3:6, Type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20 mm dia GI watering pipe with funnel and wire mesh etc and testing onc ompletion and including taking down existing earthing complete all as specified & directed by Engineer-in-charge.
NOTE FOR ITEM No. 152.00 & 153.00 [i]. Excavation & earth work in any type of soil including removing of surplus material upto 100M [ii]. PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways. [iii]. Main earthing strip from earth electrode to test point upto 7.5 mtr. [iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd. [v]. GI protection pipe of size 40 mm bore light grade 7.5m.
M&L in repair of Air termination, single pointed copper rod 18 mm dia 900 mm long with base fixing complete all as specified and as directed Engg-in-Charge..
M&L in repair for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in pipe or fixed to DBs or any other indicated situation for loop earthing with copper strip of 32X6 mm size complete all as specified and directed Engg-in-Charge.
M & L in repair of Earthing Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos 8mm dia 25mm long hex. head screw.Material and labour for testing/termination point made out of 32 x 6 mm copper strip of length 150 mm duly housed in suitable MS box insulators etc for linking the down conductor and the earth terminals of the lightening arrester system complete all as specified and as directed Engg-in-Charge.
Supply and fix in repair of insulators made out of porcelain for fixing the lightening roof conductor and the down conductor complete all as specified and as directed Engg-in-Charge.
M&L in repair of GI Tubing light grade 40mm dia.for earthing strip protection complete all as specified and directed Engg-in-Charge.
M&L in repair of for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in pipe or fixed to DBs or any other indicated situation for loop earthing with GI wire 4 mm mm size complete all as specified and directed Engg-in-Charge.
S&F in repair of for GI Tubing light grade 20 mm dia.for cable protection complete all as specified and directed Engg-in-Charge.
Supply, laying, testing and commissioning of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 volt grade with stranded aluminium conductor of size of cross sectional aera 50 Sqmm 3.5 Core with cable lugs, gland, cable termination box etc and including taking down old Unsv existing cable complete all as specified & directed by Engineer-in-Charge. Note : - Earthwork excavation sand cushioning, Jodhpur Stone patti, GI protection pipe shall be measured and paid separately in their respective items
Supply, laying, testing and commissioning of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 volt grade with stranded aluminium conductor of size of cross sectional aera 35 Sqmm 3.5 Core with cable lugs, gland, cable termination box etc and including taking down old Unsv existing cable complete all as specified & directed by Engineer-in-Charge. Note : - Earthwork excavation sand cushioning, Jodhpur Stone patti, GI protection pipe shall be measured and paid separately in their respective items
Supply, laying, testing and commissioning of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 volt grade with stranded aluminium conductor of size of cross sectional aera 16 Sqmm 4 Core with cable lugs, gland, cable termination box etc and including taking down old Unsv existing cable complete all as specified & directed by Engineer-in-Charge. Note : - Earthwork excavation sand cushioning, Jodhpur Stone patti, GI protection pipe shall be measured and paid separately in their respective items
M&L for sand cushioning to under ground cable using tibba sand and gently punning to cushioning to cable complete all as directed by Engineer-in-Charge. (Note :- Punned thickness of sand cushioning shall only measured for the purpose of payment).
Supply & laying 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and n. exc 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified & directed by Engineer-in-charge.
Supply and fixing MCCB 4 Pole 250 Amps, breaking capacity 36 KA, thermal & magnetic adjustable type, 415 volts with extended copper terminals complete and connecting links on LT panel/feeder pillar including taking down existing unserviceable MCCB complete all as specified & directed by Engineer-in-charge.
Supply and fixing MCCB 4 Pole 160 Amps, breaking capacity 25 KA, thermal & magnetic adjustable type, 415 volts with extended copper terminals complete and connecting links on LT panel/feeder pillar including taking down existing unserviceable MCCB complete all as specified & directed by Engineer-in-charge.
Supply and fixing MCCB 4 pole 100 Amps rupturing capacity 16 KA with connecting links on LT panel/feeder pillar including taking down existing unserviceable MCCB complete all as specified & directed by Engineer-in-charge.
Supply and fixing MCB TPN 63 Amps rupturing capacity 16 KA with connecting links on LT panel/feeder pillar including taking down existing unserviceable MCB TPN complete all as specified & directed by Engineer-in-charge.
Material and labour for cutting the existing bituminous road / hard standing to size not exceeding 45cm wide and depth not less than 45cm for passing of UG cable through GI pipe and making good the disturbed surface filled with excavated material and top 200mm depth with plain cement concrete 1:3:6, type C1 using 20mm graded aggregate complete all as specified & directed by Engineer-in-charge.
S&F GI pipe light grade of dia 50 mm laying in road and along with poles for cable protection complete including taking down old pipe complete all as specified & directed by Engineer-in-charge.
Supply and Fix Weather proof Street light Junction Box of size 230 x 170X105 mm depth including MCB SP 6 Amp C Curve and connecting terminals 4-way and fixing with street light poles (PCC Pole) using necessary MS Clamps, nuts, bolts washers of suitable size etc. including M& L fixing arrangement and including taking down existing unserviceable box complete all as specified & directed by Engineer-in-Charge.
S&F street light bracket made out of 40mm dia light grade GI pipe 1.5 Mtr long bend to shape including necessary fixing arrangement with MS Clamp of suitable size made out of 35 x 4 mm MS flat suitable shape to pole including nut bolts 03 Nos and washers and including taking down existing bracket complete all as specified & directed by Engineer-in-Charge.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver with separate surge protection device 5 KA rating, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete and sepatate connector block for termination of incomming cable connection and including taking down existing unserviceable light fitting complete all as specified & directed by Engineer-in-Charge.
Supply and fixing 3 core PVC insulated and unsheathed 1100 volt grade multicore cable 1.5 sqmm with stranded copper conductor cable on bottom and top of pole from looping box to security light fitting including 20mm dia PVC pipe heavy grade (from junction box to Street light fittings) with necessary fitting & fixture and including taking down existing unserviceable cable complete all as specified & directed by Engineer-in-Charge.
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate & salt up to ground level connected to galvanized iron strip 25 x 3 mm as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection including all necessary earth work, excavation, earth chamber with PCC 1:3:6, type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20mm dia GI watering pipe with funnel and wire mesh etc and testing on complete all as specified & directed by Engineer-in-Charge.
NOTE FOR ITEM No. 177.00 [i]. Excavation & earth work in any type of soil including removing of surplus material upto 100M [ii]. PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways. [iii]. Main earthing strip from earth electrode to test point upto 7.5 mtr. [iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd. [v]. GI protection pipe of size 40 mm bore light grade 7.5m.
M/s Ramniwas Bishnoi (BID ID -3085077)
M/S MAYA CONSTRUCTION COMPANY (BID ID -3086643)
GEMRARAMCONTRACTOR (BID ID -3086339)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .