Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC | L1 | Accepted-AOC SINCE LOWEST BIDDER | |
| 2 | L2₹23.0 L+₹1.5 L (6.83%)Rejected-Finance 18 GOBINDPURA STREET NO 10 PO RAYON SILK MILLS PURANI CHUNGI CHHEHTRA AMRITSAR 143001 PB | AMRITSAR | AMRITSAR | PUNJAB | 143001 | L2 | Rejected-Finance SINCE NOT LOWEST BIDDER | |
| 3 | L3₹25.2 L+₹3.7 L (17.1%)Rejected-Finance SCHEME NO 07 BLOCK NO 22 FLAT NO 03 NEW GURDASPUR DISTT GURDASPUR PB 143521 | GURDASPUR | PUNJAB | 143521 | L3 | Rejected-Finance SINCE NOT LOWEST BIDDER | |
| 4 | L4₹30.8 L+₹9.3 L (43.3%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L4 | Rejected-Finance SINCE NOT LOWEST BIDDER | |
| 5 | L5₹33.1 L+₹11.6 L (54.0%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-Finance SINCE NOT LOWEST BIDDER |
Tender Value
₹33.5 L
EMD Value
₹67,000
Closing Date
25 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AMRITSAR CANTT
HQ CWE ASR OLD CANTT
MAINTENANCE AND TESTING OF MRS AND CONNECTING ITEMS AT NAMS
2023_MES_605753_1
CWE/ASR-23/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE NAMS
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE NAMS
₹67,000
Yes
22 Sept 2023
26 Jun 2023
1 Aug 2023
26 Jun 2023
25 Jul 2023
13 Jul 2023
Amount
Servicing of HT VCB 11KV,630A /800A of Kirloskar or as per existing make alongwith tripping system and testing of vaccum circuit breaker 11KV, 630A/800A , 25KA including taking out Breaker/trolley and carried out the fwg repair/tests made for smooth operation. SM No 652/3145 HV/06 to SM No 652/3158 HV/06, SM No 652/3162-HV/17 to SM No 652/3164-HV/17, SM No 652/3126-HV/09 to SM No 652/3137-HV/09 and SM No 652/3172-HV/17 to SM No 652/3198-HV/17. (a) Cleaning and greasing of mechanism- 01 Job (b)Tightning testing of mechanism parts- 01 Job. (c ) Alignment testing and adjustment of mechanism- 01 Job. (d) Operation, testing of trip and close electrical and manual mode- 01 Job. (e) Spring charging testing electrical and manual mode- 01 Job. (f) Cleaning of panel insulater CT &PT unit- 01 Job. (g) Cleaning and tightning of control/wiring CT &PT unit- 01 Job. (h) Cleaning and testing of relay with current injection method- 01 Job. (j) Testing of auxillary relay - 01 Job. (k) Allingment of trolley, checking/greasing of shutter /lock of breaker Note :- (a) The cost of minor spare parts i.e Springs, grommets, dust cover, ring of isolator contacts, clips, pin for release prop, 'Y' Phase shround, over ride stop pin , grease and lacker spray etc. unless or otherwise mentioned here-in-after but essentially required to make the panel serviceable shall be deemed to be included in the quoted rate. Note :- All the maintenace / servicing shall be carried out by Mechanical team of PSPCL and all expenses shall be deemed to be included in quoted rates and nothing extra shall be admissible.
Servicing of HT RTCC Panel/ Capacitor Feeder Panel/ CR Panels / Bus Coupler / Bay marshal box as per existing make alongwith operating mechanism system and carried out the fwg repair for smooth operation (a) Cleaning and greasing of mechanism- 01 Job (b)Tightning testing of mechanism parts- 01 Job. (c ) Alignment testing and adjustment of mechanism- 01 Job. (d) Operation, testing of trip and close electrical and manual mode- 01 Job. (e) Control wiring and software updation / repair- 01 Job. (f) Cleaning of Panel and bus bar - 01 Job. (g) Cleaning and tightning of control/wiring AC/ DC- 01 Job. (h) Cleaning and testing of all relay - 01 Job. Note :- (a) The cost of minor spare parts i.e. grease and lacker spray etc. unless or otherwise mentioned here-in-after but essentially required to make the panel serviceable shall be deemed to be included in the quoted rate. Note:- All the maintenace / servicing shall be carried out by Mechanical team of PSPCL and all expenses shall be deemed to be included in quoted rates and nothing extra shall be admissible.
M&L for replacement of complete nut and bolts of VCB complete all as specified and as directed by Engr-in-Charge. Note :- Size of nuts and bolts are same as per existing site no other size and shape accepted.
M & L for Natural river sand for cushioning to underground cable in trench/ in ducts of sub stations/ under power transformer all as specified and directed.
Supply and fixing in replacement of silica gel for Transformers complete all as specified.
Dehydration of old transformer oil by heating and maintaing breaking capacity above 50 KV complete all as specified and directed by EIC.
Supply and fixing in replacement CT unit 300/150/5A, 15 VA 50Hz suitable for 11KV VCB Make Areva/Kirloskar/CG & other equivalent makes as specified.
Supply and fixing in replacement CT unit 100/50/5A, 15 VA 50Hz suitable for 11KV VCB Make Areva/Kirloskar/CG & other equivalent makes as specified.
Supply and fixing in replacement CT unit 600/300/5A, 15 VA 50Hz suitable for 11KV VCB Make Areva/Kirloskar/CG & other equivalent makes as specified.
Supply & Fix in replacement of old unsv conventional/ LED flood Light with new LED Flood light 120 watt ,high power SMD LED cool white, supply voltage 220/240/50 Hz, light engine driver base.pole adapter,pressure die cast polycarbonate, powder coated in IP 66 Including protection over temperature fixed on 66 KV Sub Stn grid/ Sub Stn Bldg including fixing arrangement as per site requirement ie clamps, nut and bolts etc complete all as specified and as directed.
Supply and fixing in replacement multifunction relay suitable for 11 KV ,630 Amp VCB Complete all as specified and as directed.
Supply and fixing in replacement multifunction meter suitable for 11 KV ,630 Amp VCB Complete all as specified and as directed.
Supply and fixing in replacement master trip relay suitable for 11 KV ,630 Amp VCB Complete all as specified and as directed.
Supply and fixing in repalcement 66KV lightening surge arrestor 10 KA class -II metal oxide gapless type as per existing technical specification and size for one phase complete all specified.
M&L for disconnecting of old BER OCB and hiring suitable T&P for shifting the same OCB to Sub Divn solvage store from different locations of NAMS area complete all as specified and as directed.
Supply and fix in replacement spring charging electric motor 24 V -110V , speed < 2000 RPM suitable for VCB of cap 630 Amp with complete accessories as per existing.
Material & labour for providing 20mm broken stone aggregate including spreading and levelling complete all as specified and directed.
M&L for PG Clamps/ T Connector including nut and bolt of suitable size made of aluminum suitable for 66 KV grid complete all as specified and as directed.
Supply , jointing ,testing in repair end termination jointing kit heat shrinkable out door type ,suitable for HT 11000 volts grade cable of size 185 sqmm 3 core complete all as specified.
Excavates and relaying LT cables loops near the poles / transformers, cutting the damages/burnt parts of cable and reconnecting its into positions complete with thimbles, nut bolts, sleaves all as specified and directed by Engineer-in-Charge.
Prunning of trees of over head lines of any voltage by taking proper shutdown & removing the same from site upto a distance of 50 mtr all as directed by Engr in Charge.
Material & labour for restrainging ACSR conductor HT/LT providing proper sag all as specified and directed. Note : Upto 5 conductor will be consider as one span only.
Material and labour for jointing broken/ lying on ground conductor and restrach the same conductor with straching of 3 to 4 span complete with maintaing proper sag all as specified and as directed. Note :- Conductor required for jointing broken conductor shall be included in the quoted rate. No extra payment shall be made to the contractor for the same.
Material and labour for replacement of electrical shock treatment chart in Hindi ,english and Punjabi complete with figures and letters complete of size not less than 50 cm x 75 cm Engr-in-Charge with white paint complete all as specified and as directed.
Material and labour for locating the fault in VCB, repair/ replacement of defected items, drying moisture from VCB and common complete bus bar of system and restand the elect supply complete all as specified and as directed. Note :- (i) All tools and plant including blower/ gas cylinder, spray for cleaning bus bar , spray for bus bar insulation , cleaning clothes , emergency lighting arrange in power house for repair work and other equipment will be arranged by the contractor with no extra cost paid to contractor. (ii) One VCB and common complete HT bus bar of different VCB will be catered as on Job (iii) Contractor shall deposit / Procure all the material in advance to avoid any late night fault/ after market hours / non availability of material in market. The elect supply shall be restore within 5 hours from the time of tripping / fault in day or night in the stn, failing this a panelty of Rs 5000/- per complaint / fault will be imposed on the contractor from contractor dues. (iv) Minimun one VCB shall be produce to contractor for restand/ repair for one visit. Contractor will not demand all VCB repair in one visit. Visit and Repair charges of electrician and helper are included in the quoted rate. no extra charges paid to contractor.
Material and labour for locating the fault in Transformer of any capacity , pole mounted/ plinth mounted, laid indoor on ground , repair/ replacement of defected gasket, HT bush , LT bush, replacement of thimble of transformer 160 KVA to 400 KVA , maggering transformer for detecting fault and retapping complete and make the transformer serviceable complete all as specified and as directed. Note :- (i) All tools and plant including magger , ladder and othe equipment will be arranged by the contractor with no extra cost paid to contractor. (ii) One transformer will be catered as on Job (iii) Contractor shall deposit / Procure all the material in advance to avoid any late night fault/ after market hours / non availability of material in market. The elect supply shall be restore within 5 hours from the time of tripping / fault in day or night in the stn, failing this a panelty of Rs 5000/- per complaint / fault will be imposed on the contractor from contractor dues. (iv) Minimun one transformer shall be produce to contractor for restand/ repair for one visit. Contractor will not demand all job in one visit. Visit and Repair charges of electrician and helper are included in the quoted rate. no extra charges paid to contractor. (v) Strip opening of transformer for detecting fault shall be included in the quoted rate. No extra amount shall be paid to the contractor. Note :- (i) Gasket, Copper / Aluminum thimble, HT/ LT Tape for any size of transformer will be included in the quoted rate . No extra amount shall be paid to the contractor for the same. (ii) LT/ HT rod , transformer oil and insulator shall be measured and paid seperately.
Material and labour for disconnecting all the transformer, connection (Indoor/ Outdoor, Plinth/Pole Mounted any type anywhere) and carry transformer to other location (TOP -II Yard) and shifting other transformer to the location of fault under the arrangement of contractor and connecting all the connection and make the light serviceable / functional complete all as specified and as directed. Note :- All tools, plants and vehicle for lifting and carrying shall be arranged by the contractor and not extra payment shall be paid to the contractor for the same.
Material and labour for preparing mild steel sheet board 1.6mm thick 30cm x 20 cm having letter written with white paint and red paint on MS board (MAN ON WORK/ SHUT DOWN) complete with hanging arrangement on VCB for shut down procedure and complete all as specified and as dirrected.
Excavates and relaying HT cables loops near the poles ,transformers, VCB , cutting the damages/burnt parts of cable and reconnecting its into positions complete with thimbles, nut bolts, sleaves all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of DC electric wiring kit complete suitable for Kriloskar made VCB 630 Amp and with male and female scoket 52 Pin type as per existing.
Supply and fixing in replacement of AC electric wiring kit complete suitable for Kriloskar made VCB 630 Amp complete all as specified and as directed.
Servicing and repair/maint of HV SF6 Breaker 66 KV alongwith tripping system and carried out the fwg repair made for smooth operation. (a) Cleaning and greasing of mechanism, Operation, trip and close electrical and manual mode, Spring charging testing electrical and manual mode, Cleaning of panel insulater CT &PT unit, (a) Service will be carried out through PSPCL /Service Engineer of Manfacturer /Authorised Service Engineer only. (b) The cost of minor spare parts i.e nut and bolts, springs, grommets, clips, pin etc essentially required to make the breaker serviceable shall be deemed to be included in the quoted rate.
M&L for vacuum interrupter bottle suitable of 11 KV VCB 630 Amp complete all as specified and as directed.
Supply only HT Insulation tape High quality size minimum 20 mtr long x 2 CM width complete all as specified and as directed.
M&L for cleaning and greasing of complete operating contacts of 66 KV Sub Stn Grid of 04 Nos power transformer through PSPCL mechanical team including grease and other cleaning material all as required at site compete all as directed. Note :- Necessary shut down shall be take from PSPCL . (ii) Grease for the work shall be included in the quoted rate. No extra payment shall be made to contractor for the same.
Material and labour for painting to steel gantry towers & beams for 66 KV outdoor type switch yard complete including all accessories and equipment, support, structrure including preparation of steel surface by scraping and removing old paint, applying a coat of red oxide primer and two coats good quality of aluminium paint as per following:- (a) Approximatly 11 mtr high towers (vertical) - 18 Nos (b) Approximatly 03 Mtr high towers (vertical) - 40 Nos (c ) Approximatly 06 Mtr long (Horizontal) towers - 10 Nos (d) Stand for highly arrested 3 mtr long x 2 mtr width support- 08 Nos (e) Greasing of all contact points in 66 KV switch yard. Note:- All the painting work will be carried out in the 66KV yard after proper shut down from PSPCL and as directed .
Supply and fixing in replacment of HRC Fuse cap 4 Amp suitable for 11 KV VCB DC Circuit all as specified and directed by Engr-In-charge.
Supply and fixing in replacment of HRC Fuse cap 10 Amp suitable for 11 KV VCB DC Circuit all as specified and directed by Engr-In-charge.
Supply and fixing in replacement of limit switch for 11 KV VCB of KEC Make all as specified and directed by Engr-In-charge.
Supply and fixing in replacement and providing of double space heater 80Watt each including 1.5 Sqmm wiring and thermostate suitable for 11 KV VCB complete all as specified and as directed.
Supply and fixing in replacement of Volt meter suitable of 11 KV 630 Amp VCB complete all as specified.
Supply and fixing in replacement of Amp meter DM 3 252 suitable for 11 KV 630 Amp VCB complete all as specified.
Supply and fixing in replacement of 11KV support insulator suitable for 11KV VCB (VCB make Areva,Kirloskar & CG ), dismantling and mantling of VCB Panel labour charge,high quality 11KV VCB busbar Insulation Material and Nutbolts included in quoted rates complete all as specified
Supply and fixing, in replacement, air breather with silica gel as per existing suitable for 6/8 MVA Transformers main oil tank complete all as specified and directed.
Supply and fixing, in replacement, air breather with silica gel as per existing suitable for 6/8 MVA Transformers oil conservator tank complete all as specified and directed.
S & F in replacement End termination joint heat shrinkable of any size suitable for 3 core 11000 volts XLPE HT UG cable of size 95 Sq mm to 120 Sq mm complete all as specified and directed.
Supply and fixing in replacement of auxalary switch 8 NO + 8NC complete all as specified.
Supply and fixing in replacement trip coil assembly 24V DC complete all as specified.
Supply and fixing in replacement of contactor coil 220 Volt DC complete all as per existing complete all as specified.
Supply and fixing in replacement of PLA relay of 220 volts DC , 04 MO, 04 NC complete all as specified.
Supply only heavy duty (Suitable for HT ) Copper thimble of size 120 to 185 sqmm complete all as specified.
Supply and fixing in replacement three phase over current + earth fault digital relay with high set MC 61 ANX, 4000, Volts 24 - 240 AC /DC type MC 61 ANX 4 NO, Make L&T or equivalent complete with wiring all as specified..
Supply and fixing in replacement of muster trip relay voltage 220 volt DC VAZ type of model No VAZ 413YF67B including complete wiring and make the relay functional complete all as specified and as directed.
Supply and fixing in replacement of Instantneous under voltage relay 110 Volt VAGM type of model No VAGM22AF171G
M& L for blue silica gel transformer breather 500 gm suitable for transformer of upto capacity 630 KVA complete all as specified and as directed.
Taking out existing gravels/hardcore material from the bottom of substn/equipment completely for cleaning and spraying of anti grass chemical and screnning the hardcore material and refill the same at places complete all as specified and directed by Engr in charge. Note:- Anti Grass chemical and loose filling of aggregate for topping up will be measured and paid separetly respective item of BOQ.
Supply and spraying anti vegetation chemical liquid of 1ltrs bottle mixed with water as per direction of Engr in charge . Note :- (i) Area for sparay is 66 KV MRS, TOP-I Sub Stn, TOP-II Sub Stn, Red Colony MAP Sub Stn, Kathania MAP Sub Stn, NME MAP Sub Stn, Khetarpal MAP Ssub Stn, NOC MAP Sub Stn, and other unmanned sub stn / around LT Panel in NAMS Area (ii) Complete anti vegeration chemical shall be deposit in advance and will be sprayed by the Contractor labour as per direction and location where directed.
Material and Labour straight through joint kit of heats shrinkable suitable for 120 Sqmm to 185 sqmm HT 3 core 11000 volts XPLE cable type complete all as specified and directed.
Material and labour for providing earthing of advance chemical earthing system of copper pipe chemrod 3 mtrs long 50mm dia filled with highly conducting metallic compounds with the permanent sealings at both the ends. Top of the earth electrode shall be compressed to form an extended lead with 2 holes for connecting the strip / wire to the load. To ensure the moisture content and clectrical conductivity each earting pit shall be provided with minimum 2 bags of 20 Kg chemical compound. An arrangement for connection of copper strip 25 x 3 mm to rod to be made with given teminal point through gas welding, including polymer chamber with cover proper cover alongwith locking arrangement and necessary excavation in any type of soil , returning filling in removal of surplus soil complete all as specified and as directed. MakeJK Chemical Rod/ LPI/Altec/ Akaltech & other equivalent makes as specified. Note :- Chemical earthing shall only be carried out in presence of company representative and a test report of earthig alongwith result sheet shall be submitted by the company through contractor.
Material and labour for painting of steel , 11 KV 4 pole sturecture including all channel and air break switch and clamps at power house with two coat of aliminum paint complete all as specified and as directed.
M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white , with numeric, letters in \hindi ,English and including local language and conventional skull and bones in signal red and fixed with MS Clamps , bolts and nuts of approved size for EHV (66 KV ) ,of suitable size complete all as specified and as directed.
Material and labour for top up of deficient transformer oil in transformer of any cap having dielectric strength not less than 60 KV at 4 mm gap conforming to IS complete all as specified and directed.
Supply and replacement brass stud for LT side suitable for transformers upto 600 KVA & other equivalent makes as specified.
Supply and replacement HT 11 KV bush rod suitable for indoor / outdoor type upto 600 KVA transformer complete with brass stud, brass nuts, brass cup and packing gasket complete all as spd and directed.
Material and labour for reconditioning of battery complete with changing of positive and negative cells and battery outer cover and terminals compelte with checking voltage 2 V to 2.2 V , 150-180Ah all as specified and as directed. Note:- 13 Nos battery in each TOP-I, TOP-II and 03 Nos MAP Sub Stns.
Material and labour for preparation of rig/ battery bank cage , suitable for fitting of 14 battery , 2 Volt each made of MS Iron Flat and Angle Iron 40x40x6mm having provision of top cover and locking system including lock and 2 keys and fixed in ground upto 25 cm grouted in ground and min 25 cm above ground complete all as specified and as directed.
Material and labour for replacement of HT Copper bus bar 1200 Amp, suitable for HT VCB used for common Bus bar in VCB Panel including cutting as per site and making holes for cable connectiona complete with HT insulation as per colour coding RYB and as required at site complete all as specified and as directed.
Supply and install in replacement Heavy duty battery charger 24 V suitable for charging of battery bank of VCB complete all as specified and as directed.
Routine testing of 66 KV assets by Power Grid Corporation of India/PSEB and authorised rep of manufacturer to be tested are as under ;- (a) Transformer 66 KV 6.3/8 MVA - 02 Tests to be carried out (i) IR value test of both transformer and bushings. (ii) PI value test for 20 seconds and 120 seconds. (iii) No load current test. (iv) Magnetic balance test. (v) Short circuit test. (vi) Testing of tap changer. (vii) Tan/delta test of transformer. (viii) Dielectric strength of transformer Oil (xi) Dissolved gas analysis test (b) 66 KV SF-06 Breaker (03 Nos) - Tests to be carried out by the power Grid Corporation of PSEB Protectiion team. Following test shall be carried out :- (i) IR value both in open and close position. (ii) Continuity of breaker in closed position. (iii) Tripping and closing of breaker. (iv) Functioning of all the tripping system/relays displayed on the control relay panel-such as differential o/c, earth fault, metering circuits and all other protection emanating from transformer - oil temp trip, OLTC trip, winding temp gauge trip, bucholz relay, inter trip etc, calibration of all the relays and complete Panel for time observed with respect to time setprimary injection of all the CTs, complete all as specified and directed.
(v) Greasing/oiling of all the moving parts. (vi) Operation/working of charging motor and limit switch. (c ) Testing of 11KV, VCB breaker- 16 Nos through Power Grid Corporation of India PSEB. The equipments to be tested through Protection team PSEB are as under:- Following tests to be carried out on each breaker ( Nos of Breaker - 16 Nos) ;- (i) IR Value for open/close circuit- fault relay, over load earth fault relay etc (ii) Tripping and closing time in M/S. (iii) Operation - both manual and through motor. (iv) Functioning of indicators. (v) Continuity. (vi) CT ration through primary injection. (vii) Polarity test. (viii) Testing of all the protection relay - i.e. o/c, earth fault, instantaneous, trip suspension, auxiliary relay etc. (ix) Operation/working of charging motor and limit switch. (x) Calibration of all relay, male, female contracts of VCB. Notes : (i) Any part/spare found defective during testing shall be repaired/replaced for which payment shall be made separately against respective items here in after. (ii) Test sheet shall be prepared as specified under PS clause and shall be produced.
M&L for testing of 11KV breaker through Power Grid Corporation of India , through PSEB Protection team are as under:- (NRC MAP Ph II ) (a) Tests to be carried out on each breaker ( Nos of Breaker - Five in NRC II)
M&L for testing of 11KV breaker through Power Grid Corporation of India , through PSEB Protection team are as under:- ( Kathania MAP Ph II) (a) Tests to be carried out on each breaker ( Five in Kathania II)
M&L for testing of 11KV breaker through Power Grid Corporation of India , through PSEB Protection team are as under:- (Khterpal MAP Ph II ) (a) Tests to be carried out on each breaker (Nos of Breaker - Nine in Khterpal II)
M&L for testing of 11KV breaker through Power Grid Corporation of India , through PSEB Protection team are as under:- (NOC MAP Ph II ) (a) Tests to be carried out on each breaker ( Nos of Breaker - Three in NOC II )
M&L for testing of 11KV breaker through Power Grid Corporation of India , through PSEB Protection team are as under:- (TOP-I Sub Station ) ( Nos of Breaker - Seven in TOP-I )
M&L for testing of 11KV breaker through Power Grid Corporation of India , through PSEB Protection team are as under:- (TOP-II Sub Station ) ( Nos of Breaker - Ten in TOP-II )
M&L for testing of 11KV breaker through Power Grid Corporation of India , through PSEB Protection team are as under:- (NME MAP Ph II) (a)Tests to be carried out on each breaker ( Nos of Breaker - One in NME Ph II) Note for srl Item No 70 to 76 (a) Following tests to be carried out on each breaker ( for Srl Item No 70 to 76) (i) IR Value for open (ii) Tripping and closing time in M/S. (iii) Operation - both manual and through motor. (iv) Functioning of indicators. (v) Continuity. (vi) CT ration through primary injection. (vii) Polarity test. (viii) Testing of all the protection relay - i.e. o/c, earth fault, instantaneous, trip suspension, auxiliary relay etc. (ix) Operation/working of charging motor and limit switch. (x) Calibration of all relay, male, female contracts of VCB. Note : - (i) Any part/spare found defective during testing shall be repaired/replaced for which payment shall be made separately against respective items here in after except for minor parts such as packing, nuts bolts, cotton waste etc for which cost shall be deemed to be included in the unit rate quoted for this item.
SUN CHEMICALS
HARPAL ENGINEERS AND BUILDERS
R D Bansal
kailu construction co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .