| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.5 LAccepted-AOC BHAWANI KRUPA GANDHI CHOWK PULGAON | PULGAON | WARDHA | MAHARASHTRA | L1 | Accepted-AOC Being Lowest and Quoted rates are reasonable | |
| 2 | L2₹44.6 L+₹3.8 L (9.42%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹44.8 L+₹4.1 L (10.0%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹45.2 L+₹4.5 L (11.0%)Rejected-Finance PULGAON | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹50.1 L+₹9.4 L (23.0%)Rejected-Finance 011 NAGAREWADI 612 NAGAREWADI POST PADALI TALUKA SHIRUR KASAR DISTRICT BEED 413249 BEED MAHARASHTRA 413249 UDYAM MH 05 0079863 | BEED | MAHARASHTRA | 413249 | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
2 Apr 2024, 6:00 pmClosed
GE PULGAON
GE PULGAON CAD CAMP PULGAON PIN 442303
REPAIR/REPLACEMENT OF LT PANELS/LT OH LINES/CABLES AND OTHER CONNECTED WORKS AT CAD DEPOT AREA UNDER GE PULGAON
2024_MES_646023_1
8112/PUL/E8
Open Tender
Civil Works
Item Rate
270 days
GE PULGAON
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE PULGAON
₹80,000
Yes
7 May 2024
12 Mar 2024
9 Apr 2024
12 Mar 2024
2 Apr 2024
28 Mar 2024
12 Mar 2024 - 27 Mar 2024
Amount
Taking out LT XLPE/PVC insulated armoured cable alongwith all joints of any size from trenches wall/roof including taking out of brick layer and sand from trenches complete all as directed by Engr-in-Chrage.
Supply and fixing Double wall Corrugated High Density Polymer Ethylene (HDPE) pipe of following sizes as per IS 14930 (Part-2):2001, Laid in trenches/floors and fixed on walls/poles, with and including neccessary fittings such as bends, sockets and other connected accessories etc., for laying of electric cables, complete all as specified and as directed.
HDPE pipe size 50 mm diameter
HDPE pipe size 90 mm diameter
HDPE pipe size 120 mm diameter
Excavation in trenches by mechnical means (hydraulic excavator) not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out all kind of soil complete all as specified and as directed.
M&L for Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm in soft/loose soil. complete all as specified and directed Engr-in-Chrage.
Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and directed Engr-in-Chrage.
Supply, laying and testing LT XLPE insuated PVC bedded galvanised steel strip or wire armoured earthed electric power cable with aluminium conductor 1100 volts grade, heavy duty in trenches/along pole or wall of following sizes complete all as specified and directed by Engineer-in-Charges. Note:- 1. Excavation and earth work, sand cushioning, brick pipes, clamps, and cable joint shall be measured and paid separetely under respective items :-
10 Sqmm 2 core
16 Sq mm 2 core
16 Sq mm 4 core
25 Sq mm 4 core
35 Sq mm 3.5 core
50 Sq mm 3.5 core
70 Sq mm 3.5 core
95 Sq mm 3.5 core
120 Sq mm 3.5 core
185 Sq mm 3.5 core
240 Sq mm 3.5 core
Re- laying LT XLPE insuated PVC bedded galvanised steel strip or wire armoured earthed electric power cable with aluminium conductor 1100 volts grade, heavy duty in trenches/along pole or wall of following sizes complete all as specified and directed by Engineer-in-Charges. Note:- 1. Excavation and earth work, sand cushioning, brick pipes, clamps, and cable joint shall be measured and paid separetely under respective items :-
16 Sq mm -35 Sqmm 3.5/4 core
50 Sq mm-70 sqmm 3.5/4 core
95 sqmm-240 Sq mm 3.5/4 core
Supply & laying in repair galvanized steel tubing "light grade" with all fittings in trenches/ under roads/ along pole/ wall for cable protection all as specified & directed by Engr-in-Chrage. for the following sizes : - .
40 mm bore
50 mm bore
80 mm bore
100 mm bore
Material and Labour for drilling boring horizontally (manually) through path/road/culverts for laying cable all as directed by Engr in charge.
M&L for tesitng of faulty LT XLPE/PVC armoured cable of any size and any position at CAD Pulgaon by using LT voltage testing kit installed on movable vehicle complete all as specified and directed by Engr-in-Chrage. Note : This job includes cost of vehicle transport from Nagpur to Pulgaon and back
Supply & Fixing in repair cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 and 4 core XLPE armoured aluminium conductor cable complete all as specified and directed by Engr-in-Chrage. for the following size. .Make 3M-Seal/Birla/Denson:- Note : Excavation, returning filling, sand brick and removel shall be measured and paid separatly under relevant item of this BOQ
For cable 6 -16 Sqmm 4 Core
For cable 25 to 50 sq mm 3.5 core
For cable 70 to 120 sq mm 3.5 core
For cable 150 to 185 sq mm 3.5 core
For cable 240 to 300 sq mm 3.5 core
Dismantling and taking out the existing unserviceable (damaged/broken) or serviceable tilted Panel of any type and any size, from Location and removal from site all as directed by Engr-in-Chrage.
Material and Labour for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation of pole upto ground level complete all as directed by Engr-in-Chrage.
PCC (1:3:6) type C-1 using 20 mm graded stone aggregate as in coping/plinth block including necessary form work all as directed by Engr-in-Chrage.
Supply install, testing and commissioning Out door, in replacement of LT Distribution Panel Feeder Pillar (CPRI approved) Cubicle type,IP-56,outdoor type confirming to IS: 61439 Part I & II factory fabricated made out of outer cover with 3 mm thick CRCA sheet & inner cover with 2mm thick CRCA sheet of suitable size to accommodate all accessories / fittings, compartmentalized in costruction to accommodate the incoming MCCB and TPN bus bars and outgoing MCCBs feeders. The TPN busbars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator at an interval of not more than 500 mm through out the length of the TPN bus bar. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/Epoxy insulators having provision for termination of incoming and outgoing cables. The cubicle shall have a bottom and four legs (400mm long) of size 50x 50x6 mm, The panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY STRUCTURE after seven tank phosphating treatment, front & back opening type, and fixing 2 Nos.danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel with voltage and danger indicated in Hindi and English, with double door shutter and shall have louvers and airvent gasket for natural flow of air, Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following Make of panel board: Advance/ Shalabh / Adlec / Tricolite. Make of ACB & MCCB : ABB / L&T / SIEMENS / SCHNEIDER.
M& L for taking out LT feeder panel front and back type opening replace old clamps and fix new hinges by drilling or belding as per condition , replaced burnt out lugs and insulation , proper, insulation taping to XLPE cable and painting inner and outer side , top and bottam, including cleaning of grass around, from the panel till 2mtr and from road to panel for easy operation complete all as specified and drirected by Engr-In-Charge
M& L for taking out LT feeder panel all cables from loops, for fixing GI Pipe for cable protection and making new foundation in place of broken foundation with PCC 1:4:8 in 40 mm graded stone aggregate and re-fixing all cables with proper lugs after inserting through GI pipe complete. Note :; PCC shall be measured and paid in the respective items.
S&F for Indicator lamp neon/LED type (set of three )
S& F for Panel Wiring with suitable size PVC insulated PVC sheathed 1100 volts grade FRLSH type with copper conductor multistranded cable not less than 1.5 sqmm with lugs on both ends of cable.
S&F of MCCB in replacement 3 Pole from 25 Amps to 100 Amps fixed type 16 KA, 415 volts complete all as specified and directed including taking out old one MAKE:L&T /Legrand/GE/C&s/schnieder
S&F of MCCB in replacement 3 Pole from 125 Amps 16 KA, fixed type 415 volts complete all as specified and directed including taking out old one MAKE:L&T /Legrand/GE/C&s/schnieder
S&F of MCCB in replacement 3 Pole 160 amps 36 KA 415 volts adjustable type complete all as specified and directed including taking out old one MAKE:L&T /Legrand/GE/C&s/schnieder
S&F of MCCB in replacement 3 Pole 200 amps 36 KA 415 volts adjustable type complete all as specified and directed including taking out old one MAKE:L&T /Legrand/GE/C&s/schnieder
S&F of MCCB in replacement 3 Pole 250 amps 36 KA 415 volts adjustable type complete all as specified and directed including taking out old one MAKE:L&T /Legrand/GE/C&s/schnieder
S&F of MCCB in replacement 3 Pole 400 amps 36 KA 415 volts adjustable type complete all as specified and directed including taking out old one MAKE:L&T /Legrand/GE/C&s/schnieder
Material and labour in replacement/repair for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI strip 32mm X 6mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (2009) connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt alround earth plate, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) 50mm thick cover reinforced with 8mm dia TMT bars @ 100mm c/c both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm bore GI medium grade earth lead protection pipe, complete all as specified and directed. Note :- Earth strip 32x6 mm and protection pipe 40 mm dia up to 7.5 mtr shall be included in quoted rate.
S&F for GI earthing strip 32x6 mm with nut and bolts complete including taking down old one all as specified and directed by Engr-In Charge
M&L for Preparation of old painted surfaces of steel tubular poles 9/11 Mtr long including cross arms protection pipe and painting one coat of aluminium paint e ground level to top of pole and cross arms and protection pipe paint including writing poles numbers in white letter on black ground complete all as specified and directed by Engr-in-Charge.
S and F in repair loop in / loop out box of internal size 250 x 210 x 115mm made out of FRP (Hot moulded type) with weather proof canopy and locking screws alongwith 5/6 Amps MCB-01 No, 15 Amps rated 3 pole connector - 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector complete in the box, duly fixed to steel tubular pole using 25 x 3mm FI clamp with suitable gland and lugs for connecting cable including taking down old one complete all as specified and as directed. Make :- HENSEL / SINTEX / HANSU of model HB 14.
Taking down existing rusted/broken out MS cross arm, angle, clamps, nuts, bolts and washers and supply and fixing new MS Cross arms, bracings, supports, clamp and back plates fabricated for cable cover frame work, from structural steel section including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any type, shape or as indicated and directed inclusive of one coat of red oxide primer and two coats of aluminium paint complete all as specified and directed.
M&L in replacement of unserviceable jumper of ACSR Conductor with new jumpers of ACSR conductor of suitable size including binding properly on the existing OH line with clamp, nuts & bolts etc.complete all as specified and directed.
supply and fixing in replacement of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size
supply and fixing in replacement of Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade
Supply and fixing in replacement of guard wire under LT Over head line Cradles, hexagonal/rectangular,fabricated with galvanised steel wire 3.15 or 4mm dia
Supply and fixing in replacement Manual Onload changeover switch in sheet steel enclosure, Type - CO2-200, 415 Volt , 50 Hz four pole 200 Amp Cat Part No. CO22000OSOO Make :L&T or equivalent in Havells/Legrand
Supply and fixing in replacement Manual Onload changeover switch in sheet steel enclosure, Type - CO1-100, 415 Volt , 50 Hz four pole 100 Amp Cat Part No. CO11000OSOO Make :L&T or equivalent in Havells/Legrand
I P Constructions
M/s MM TRADERS
M/S Maa Durga Constructions,Pulgaon
MAHARASHTRA ENTERPRISES
Bidder Name
MAHARASHTRA ENTERPRISES
M/S Maa Durga Constructions,Pulgaon
M/s MM TRADERS
M/S JAI BHAWANI CONSTRUCTIONS
I P Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .