CWE (A) Jaisalmer
HQ CWE(A) JAISALMER
REPAIRS AND MAINTENANCE OF AC PLANTS UPPER AND LOWER AT ARMED UNITS, WEU, AMN COY AND MISC REPAIR WORK UNDER GE (A) JAISALMER.
2026_MES_793310_1
84487/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
JAISALMER
AS PER NIT
8 documents required · 8 mandatory
₹500
GE ARMY JAISALMER
₹62,000
Yes
10 Oct 2026
10 Oct 2026
2 Nov 2026
10 Oct 2026
31 Oct 2026
24 Oct 2026
10 Oct 2026 - 17 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and charge refrigerant gas R-407 in AC plant, of any capacity complete all as specified & directed by Engineer-in-charge. | 530 | Kg | - | - |
| 2 | M&L in repair condensor unit suitable for 12.5 TR compressor complete all as specified and directed by Engineer-in-charge. Including Gas kits, daffle plate,connecting rods,liquid port,dischagre port,service valve,service valve port , copper rods ( any size as requried of site),expender plate, condensor cell , End cover,high pressure realse valve port etc .all other equipment that are requried to functional the condensor unit complete all as per specified and directed by engg-in- chagre . make-voltas/bluestar/carrier/teknotherm | 2 | Each Job | - | - |
| 3 | M & L for Descaling of condensers of 12.5TR capacities with minimum dia 25cm & length 100cm by isolating the condenser's by closing the water inlet and outlet connections recirculating dilute HCL by descaling pump until the scale is removed, opening the both end covers of the condenser, brushing the condenserr water tubes with nylon brush until the scale and dust deposits are removed, neutrlising with caustic soda solution, flushing out the tubes with fresh water, refixing the condenser end covers after replacing the warn out parts like gaskets, bolts, nuts, washers etc. Opening the inlet and outlet water line connections including testing and commissioning of following condensers, all as specified and directed by Engr-in-Charge. ( Note :- Shell & tube condenser should be descaled quarterly once and each descaling are measured and paid separately) | 54 | Each Job | - | - |
| 4 | Supply and replacing of compressor oil 25/50 TR for compressor as per site complete all as specified & directed by Engineer-in-charge | 100 | Ltrs | - | - |
| 5 | M&L for servicing servicing of AHU of 8000/10000 CFM AC plant including cleaning of filters by cleaning with chemical solution as required at site complete all as specified & directed by Engineer-in-charge. | 12 | Each Job | - | - |
| 6 | Disconnecting the electrical connection & taking down the burnt out motor of capacity 10 HP from AC Plant and transporting to workshop for repair, dismantling the motor & taking out burnout copper winding and rewinding the same with super enamelled copper wire as per existing guage including replacement of bearings & correcting minor defects, reassembling, incl any machinary works such as welding, grinding, tuning, polishing etc and transporting motor from workshop to site, reinstalled at site, reconnecting, testing and commissioning complete all as specified & directed by Engineer-in-charge. | 4 | Each Job | - | - |
| 7 | All as per iem No 6 above but of capacity 7.5HP motor of pump set/compressor motor/ cooling tower/ blower motor, 3 Phase, 450 Volts | 8 | Each Job | - | - |
| 8 | All as per iem No 6 above but 5 HP motor for pump set/ Compressor motor/blower motor/cooling tower motor, 3 Phase, 450 Volts | 10 | Each Job | - | - |
| 9 | All as per iem No 6 above but of capacity 3 HP motor of pump set/compressor motor/ cooling tower/ blower motor, 3 Phase, 450 Volts | 4 | Each Job | - | - |
| 10 | All as per iem No 6 above but 2 HP motor for pump set/ Compressor motor/blower motor/cooling tower motor, 3 Phase, 450 Volts | 2 | Each Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
Tender.pdf
Tender Documents • 2.49 MB
BOQ_889630.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .