Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance PLOT NO RZ B 1 59 KH NO 534 535 BLOCK B 1 NEW ROHANPURA PP NO 1416 NAJAFGARH NEW DELHI 110043 | NEW DELHI | NAJAFGARH | DELHI | 110043 | Admitted-Finance |
| 5 | Admitted-Finance PLOT NO 17 GF PRATAP NAGAR NEW DELHI 110064 | WEST | DELHI | 110064 | Admitted-Finance |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
17 Jun 2020, 6:00 pmClosed
GE AF FARIDABAD
Garrison Engineer AF Faridabad Dabua Colony Faridabad Haryana Pin-121005
PROVN OF GREASE TRAP ON BASANT NAGAR OFFICERS MESS PROVISION OF SHIFTING OF GATE TOWARD NEWLY ACQUIRED LAND AT TECHNICAL AREA AND REPAIRS OF FLOOR WALL TILES ALUMINUM JOINERY AND OTHER MISC ITEMS AT MCC BASNAT NAGAR
2020_MES_348000_1
GE (FBD)/AF-05/2020-2021
Open Tender
Civil Works
Item Rate
240 days
AF STATION PALAM
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF FARIDABAD
₹38,000
Yes
29 Jun 2020
29 May 2020
19 Jun 2020
29 May 2020
17 Jun 2020
5 Jun 2020
30 May 2020 - 4 Jun 2020
Amount
Excavating over areas, n exc 1.5 m deep and getting out in any type of soil complete all as specified and as directed by the Engineer-in-Charge
Excavating over areas, exc 1.5 m deep and n exc 3m getting out in any type of soil complete all as specified and as directed by the Engineer-in-Charge
Removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by the Engineer-in-Charge
M&L for PCC 1:2:4 Type B2 using 40mm graded stone aggregate as in mass concrete complete all as specified and as directed by the Engineer-in-Charge
M&L for Precast cement concrete 1:2:4, type B1 (Using 20 mm graded stone aggregate) in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge
M&L for Mild steel TMT 6 mm to 8 mm dia., cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips qualit complete all as specified and as directed by the Engineer-in-Charge
S&F Coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0. 11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match over 20 mm thick screed bed or bedding layers in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge
Coloured Glazed ceramic tiles 300 x 200 x 7 mm thick, on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over 15 mm thick screed bed or bedding layers in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge
Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by the Engineer-in-Charge
S&F for joists, channel, angle or tee sections fixed independently with out connecting plates Fe 410-0 complete all as specified and as directed by the Engineer-in-Charge
S&F Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, with revited ,bolted or welded attachement complete all as specified and directed by Engr-in-Charge
Synthetic enamel painting two coats to steel surfaces of any description exc 10cm width or girth over a coat of red oxide primer incl preparation of new surfaces complete all as specified and as directed by the Engineer-in-Charge
S&F PVC (SWR) pipes 250 mm dia single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed by the Engineer-in-Charge
M & L for 20-25 mm thick Sand cusion for laying of paver block tile complete all as specified and as directed by the Engineer-in-Charge
M & L for 60 mm thick Machine pressed precast concrete inter locking Paver Block tiles with grey cement and Pigment complete all as specified and as directed by the Engineer-in-Charge
Demolition of brick work or stone bulders masoary built in cement mortar complete all as specified and as directed by the Engineer-in-Charge
Demolition of reinforced concrete any description complete all as specified and as directed by the Engineer-in-Charge
Dismantling wrought iron or mild steel work of any description complete all as specified and as directed by the Engineer-in-Charge
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in Hard/ Dense soil complete all as specified and as directed by the Engineer-in-Charge
Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soil complete all as specified and as directed by the Engineer-in-Charge
Removing Excavated soils exceeding 1.50 Km but not exceeding 5.0 Km and depositing where complete all as specified and as directed by the Engineer-in-Charge
Form work to sides of foundation, footings similar work exc 200 mm thick complete all as specified and as directed by the Engineer-in-Charge
Fair finished flat Form work to sides of pillars vertical surfaces such as columns, struts etc , similar work exc 200 mm thick complete all as specified and as directed by the Engineer-in-Charge
M&L for RCC for bands using type B1 using 20 mm graded stone aggregate 1:2:4 complete all as specified and as directed by the Engineer-in-Charge
M&L for RCC for column footings using type B1 using 20 mm graded stone aggregate 1:2:4 complete all as specified and as directed by the Engineer-in-Charge
M&L for RCC columns using type B1 using 20 mm graded stone aggregate 1:2:4 complete all as specified and as directed by the Engineer-in-Charge
M&L for TMT bars 10 mm dia, and over cut to length, bent to shape required, including cranking, bending spically for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia, or securing with clips complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick on other than fair faces of brick work in cement mortar 1:4 , surface finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge
M/L for PCC type B0 1:2:4 (using 12 mm graded for copying complete all as specified and as directed by the Engineer-in-Charge
Fixing only framed work such as gates railing and similar works confirming to FE290 complete all as specified and as directed by the Engineer-in-Charge
M&L for one coat of synthetic enamal paint for old steel surfaces complete all as specified and as directed by the Engineer-in-Charge
M&L Preparing new surface of wall and applying two coats of cement primer over one coat of primer complete all as specified and as directed by the Engineer-in-Charge
Surface Excavation not exceeding 30 Cm deep and averaging 21 Cm deep and getting out in Hard dense soil complete all as specified and as directed by the Engineer-in-Charge
M&L Two layers of hardcore of guage n. exe 63 mm broken stone deposited spread and levelled in layers n.exe 15 cmm thick ,watered and rammed to a true surfaces complete all as specified and as directed by the Engineer-in-Charge
M & L for 100 mm thick cement concrete 1 : 4 :8 type D-2, (using 40 mm graded stone aggregate) as flooring finished without using extra cement complete all as specified and as directed by the Engineer-in-Charge
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed by the Engineer-in-Charge
M/L for brick work with Sub class B brick straight or curved on plan exc 6 m mean radius built in Cement mortar 1: 6 complete all as specified and as directed by the Engineer-in-Charge
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 coplete complete all as specified and as directed by the Engineer-in-Charge
M&L for preparing old surfaces of walls and applying two coat of white wash incl complete removal of existing treatment complete all as specified and as directed by the Engineer-in-Charge
Dismantaling water tanks and removing to store exc 500 but n. exc 1000 ltrs capacity complete all as specified and as directed by the Engineer-in-Charge
S&F rotational moulded polyethylene water storage tanks (cylinderical, vertical with closed top) of 1000 Ltrs capacity hoisted and fixed in position complete all as specified and as directed by the Engineer-in-Charge in SSR Pt I
S&F in repair Ball brass valve, high pressure with polythelene float and fly nut complete, screwed for iron pipe or brass ferrule 20 mm Dia complete all as specified and as directed by the Engineer-in-Charge
S&F for Gun-metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed in repair for 20 mm bore pipe complete all as specified and as directed by the Engineer-in-Charge
M&L for 10mm thick cement plaster in cement mortar (1:4) on on ceilings of concrete surfaces, including finishing surface even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge
M/L for preparation of newly plastered surfaces of walls/ceilings and applying two coats of oil bound distember over a layer of wall care putty ( Birla/JK white putty) to obtain smooth finish complete all as specified and as directed by the Engineer-in-Charge
M&L for preparing old surfaces of walls and applying two coat of white wash incl complete removal of existing treatment complete all as specified and as directed by the Engineer-in-Charge
M&L for preparing old decorated surfaces and applying two coat of white wash.on surface of ceilings complete all as specified and as directed by the Engineer-in-Charge
Complete removal of existing treatment on walls and applying two coats of Plastic Emulsion paint over a coat of oil based primer over a coat of birla white putty complete all as specified and as directed by the Engineer-in-Charge
Complete removal of existing treatment and applying two coats of exterior emulsion apex paint over wall care putty including a coat of primer as per manufacturers instruction complete all as specified and as directed by the Engineer-in-Charge
M/L for complete removal of existing treatment and applyig two coats of cement base paint complete all as specified and as directed by the Engineer-in-Charge
M/L for complete removal of existing treatment and applyig two coats of oil bound distember complete all as specified and as directed by the Engineer-in-Charge
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc., laid, bedded and pointed in any mortar complete all as specified and as directed by the Engineer-in-Charge
All as per item above but as in skirting / dado over 10 mm thick cement mortar in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge
All as per item No 55 above but as in counters including cutting for WHb , moulding / chamfering to all exposed surfaces complete all as specified and as directed by the Engineer-in-Charge.
M & L Dismantling floor, hearth or wall tiling or stone flooring including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by the Engineer-in-Charge
M&L for digital design glazed ceramic tiles in vertical surface of size of each tile 300 x 600 mm and 7 to 8 mm thick fixed to wall with 10 mm thick cement sand mortar in CM 1: 4 , set and joint in neat cement slurry and pointed in white or coloured cement to match the same complete all as specified and as directed by the Engineer-in-Charge
S&F Coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0. 18 sqm but not exceeding 0.38 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match over 15 mm thick screed bed or bedding layers in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge
M&L for 600mmx600mmx9mm thick vetrified coloured and printed tiles of any shade as approved as in flooring( in any pattern) and jointed with neat cement slurry over 15 mm thick cement screed in CM 1:6 and pointed with coloured cement matching with surfaces of tiles as in floor complete all as specified and as directed by the Engineer-in-Charge
All as per item No 61 above but as in skirting set and jointed with neat cement slurry over 10mm thick cement screed in cement mortor 1;4 and pointed with colour cemnt matching with surfaces of tiles as in skirting and complete all as specified and as directed by the Engineer-in-Charge
S & F in repair colour EWC model LYS-IVY -0204 of Jaquar or Equvlent ‘S’ trap vitreous china including all fittings i.e seat cover, cistern super water saver dual, flush complete all as specified and as directed by the Engineer-in-Charge
M & L for repair counter top oval shape white / ivery coloured wash hand basin of size 56 x 41cm make- CNS-Ivy-WB07 of Jaquar or Equvlent complete all as specified and as directed by the Engineer-in-Charge
S & F for repairs 15 mm bore bib taps chromium plated with wall flange and fancy type with crutch or butter fly handle high pressure screwed down of complete all as specified and as directed by the Engineer-in-Charge. Make- ORM-10037of Jaquar or Equvlent.
S & F for repairs single lever basin mixer with popup waste system and 450 mm long braidaed hoses chromium plate of complete all as specified and as directed by the Engineer-in-Charge Make- ORM-10051 B of Jaquar or Equvlent.
S & F for repairs 15 mm angle valve chromium plated with wall flange and fancy type with high pressure screwed down and with CP flange of same make complete all as specified and as directed by the Engineer-in-Charge of Make- ORM-10053 of Jaquar or Equvlent.
S & F in repairs for single lever sink mixer with swinging spout on upper side with connecting legs and wall flanged complete all as specified and as directed by the Engineer-in-Charge Make- ORM-10165 of Jaquar or Equvlent.
S & F in repair for CP waste coupling 32mm size half threaded with 130mm height complete all as specified and as directed by the Engineer-in-Charge.Make-ALD-709 of Jaquar or equvelent
S & F in repair for CP bottle trap with internal partition 32mm size 300 mm x 190 mm with wall connection pipe and wall flange complete all as specified and as directed by the Engineer-in-ChargeMake-ALD-769 L of Jaquar or equvelent
S & F in repair for 450mm long braided house with two 15mm nut and rubber washers without nipple complete all as specified and as directed by the Engineer-in-Charge Make-ALD-805 B of Jaquar or equvelent.
S & F in repair for hand shower( health faucet )with with 1.0 m long easy flex tube in chrome finish and wall hook complete all as specified and as directed by the Engineer-in-Charge Make-ALD-CHR-565 of Jaquar or equvelent.
S & F in repair for CP towel racks with lower hanger complete all as specified and directed by Engr-in-Charge Make-AHS-1581 of Jaquar or equvelent. complete all as specified and directed.
S & F in repair for CP Soap dish of Make-AQN-7731 of Jaquar or equvelent complete all as specified and as directed by the Engineer-in-Charge
S&F in repair for CP telephonic jet with all fitting and fixture for EWCs of Make- Jaquar or equvelent complete all as specified and as directed by the Engineer-in-Charge
S & F for vitrious china sensor urinals Make- Jaquar cat part No-URS-WHT-0704 & SNR-51097 or equvelent including all necessary fittings etc complete all as specified and as directed by the Engineer-in-Charge
S & F for 8 mm thick toughend frosted glass urinal partitions Make- Jaquar cat part No-1810-US or equvelent including all necessary stainless steel fitting etc complete all as specified and as directed by the Engineer-in-Charge.
Dismantling of any type of ceiling boarding with and including GI frame work of any description fixed in any position fixed with screws complete all as specified and as directed by the Engineer-in-Charge
S & F 12 mm thick semi perforated particle boards/tiles for insulation and accoustic purposes 600 mm x 600 mm size wixed in aluminium snap grid ceiling of 605 x 605 mm size and 6 mm GI wire tied with roof or necessary fasters complete all as specified and as directed by the Engineer-in-Charge
S&F venitition blinds as window curtais of approved make and quality as approved complete all as specified and as directed by the Engineer-in-Charge
Taking down Chowkats or frames not exceeding 1.5 Sq. M each (Without taking off shutters from the frames)and removing to store complete all as specified and as directed by the Engineer-in-Charge
Taking down and removing to or from stores Chowkats or frames exceeding 1.5 Sq. M but not exceeding 4 Sq. M each (Without taking off shutters from the frame) complete all as specified and as directed by the Engineer-in-Charge
S&F Anodised aluminium frame for doors, windows, Ventilators/ Partition with one or more rebates including joining cleat for fixing etc complete all as specified and as directed by the Engineer-in-Charge
S&F anodized aluminium window and ventilator shutters, Sliding type without sash bar, aluminium section weighing 0.55Kg/m including necessary jointing cleats, glazing clips rubber packing, anodised aluminium snap beading screws anodized aluminium fittings such as peg stays 150 mm long (1 No), hinges type B-21 100 mm long (2 No) suitable handle (1 No) complete all as specified and as directed by the Engineer-in-Charge
S&F anodized aluminium door shutters aluminium section weighing 0.55Kg/m including necessary jointing cleats, glazing clips rubber neoprene packing, handles 2 Nose in each door, hinges, anodised aluminium snap beading screws etc complete all as specified and as directed by the Engineer-in-Charge
S & F 5.5 mm thick Sheet glass, ordinary quality and glazing with oil putty in squares exceeding 0.5 Sq. M in each pane complete all as specified and as directed by the Engineer-in-Charge
S&F double action floor spring hydraulically regualted made up of aluminium 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and as directed by the Engineer-in-Charge
S & F Aluminium body door closer hydraulically regulated, designation No. 3 universal type, suitable for door shutters of 851 oto 1000 mm in width and of weight between 61 to 80 Kg complete all as specified and as directed by the Engineer-in-Charge
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails. M.S frame shall bw covered with heat moulded plain colour PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and with wood grain PVC sheets for top rail, lock rail and botom rail on either side & as gap insert for tip rail & bottom rails; Panelling of wood grain PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement.icludin two nos pvc handles and 150 mm long PVC tower bolt suppling and fixing in the frame at site as per specification & drawing complete all as specified and as directed by the Engineer-in-Charge
Soild PVC Door frame of size 50 mm x 47 mm made out of 5 mm frame with wood grain printed PVC sheet reinforced with MS square tube, suppling and fixing in opening as per specification and drawing complete all as specified and as directed by the Engineer-in-Charge
Taking down steel tubings and connections of 15 mm bore and removing to store complete all as specified and as directed by Engr-n-Chage
Taking down steel tubings and connections of 20 mm bore and removing to store complete all as specified and as directed by Engr-n-Chage
S&Laying of 15 mm CPVC Pipes with fittings on walls/ceillings and laying under floor complete all as specified and as directed by the Engineer-in-Charge
S&Laying of 20 mm CPVC Pipes with fittings on walls/ceillings and laying under floor complete all as specified and as directed by the Engineer-in-Charge
S&F Cast iron floor trap 100mm dia with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4)
M&L for repairs to existing texture finish of any patteran /texture complete all as specified and directed by Engr-in-Charge.
M/s KUNDU CONSTRUCTION
M/S CHANDER MUNI
M/s Durga Traders
Kunal Construction Co.
H.B. Traders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .