Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 LAccepted-AOC | ₹3.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹3.9 LRejected-Finance 121004 | ₹3.9 L | L2 | Rejected-Finance UNSUCCESFUL-L2 |
| 3 | L3₹4.1 LRejected-Finance | ₹4.1 L | L3 | Rejected-Finance UNSUCCESFUL-L3 |
Tender Value
₹3.9 L
EMD Value
₹7,738
Closing Date
29 Jun 2026, 12:00 pmClosed
Executive Engineer, Bankura Division, PWD
Office of the Executive Engineer Bankura Division PWD Kenduadihi Bankura
Making partition walls and installation of fire-resistant doors inside the UPS room of Super Speciality building of Bankura Sammilani Medical College and Hospital under Bankura Division PWD (Civil Work) (2ndCall)
2026_WBPWD_5015497_4
WBPWD/EE/BANKURA DIVISION/NIT- 03/2026-2027
Open Tender
CIVIL WORKS
Percentage
30 days
Bankura
Please refer Tender documents.
4 documents required · 4 mandatory
₹7,738
17 Aug 2026
15 Jun 2026
1 Jul 2026
20 Jun 2026
29 Jun 2026
20 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Brick work with 1st class bricks in cement mortar (1:6).b)
In superstructure, ground floor | 30.6 | Cu.m. | 4,682.81 | ₹1,43,293.99 |
| 2 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.
(A) Pakur Variety. In Ground Floor | - | Cu.m. | 5,340.77 | - |
| 3 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction
(a) For works in foundation and upto roof of ground floor/upto 4 m
(i) Tor steel/Mild Steel
II. JSW/JSPL/SHYAM/SRMB/BMASL/ELECROSTEEL/SSL | 1 | MT | 54,741.47 | ₹54,686.73 |
| 4 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor).
(c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work.
In Ground Floor | 12.24 | Sq.m. | 357 | ₹4,369.68 |
| 5 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface]
(i) With 1:6 cement mortar. (b) 20 mm thick plaster
In Ground Floor | 129.12 | Sq.m. | 149.71 | ₹19,330.56 |
| 5.01 | (i) With 1:6 cement mortar. (c) 15 mm thick plaster
In Ground Floor | 93.78 | Sq.m. | 132.53 | ₹12,428.66 |
| 6 | Supplying, fitting & fixing fire resistant door frame conforming to IS:3614, tested and certified as per laboratory approved by Engineerin- charge, of section 143 x 57 mm having built in rebate made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 120 minutes fire rated door shutters. The frame is fitted with intumescent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with back plate bracket and anchor fastener of approved size and make. Rubber door silencers should be provided on striking jamb.
Supplying, fitting & fixing fire resistant Door leaf of 46 mm thick fully flush double skin glazed fire resistant door shutters with or without vision lite, of 120 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 18 SWG G.I. sheet (zinc coating not less than 120 gm/ m2) duly filled heat-resistant phenolic resin bonded insulation material (honeycomb craft) and fixing with necessary stainless steel ball bearing hinges of approved make. For pair of doors astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturer recommendation with a beeding and screw from inside. The glass should be 6mm clear borosilicate fire rated glass of relevant rating.
All door and frames shall be finished with polyurethene aliphatic grade paint of approved colour including applying a coat of approved brand fire resistant primer. The door leaf and frame shall have passed minimum 250 hours of salt spray test. Rate should include supply and installation complete as per direction of Engineer - in- charge.
i) 2 hour Fire rated door single leaf of size (1200 mm x 2180 mm) | 4 | Nos. | 22,523 | ₹90,092 |
| 7 | a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.
(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.
In Ground Floor | - | Qntl. | 9,888 | - |
| 8 | (a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. | 7.56 | Sq.m. | 29 | ₹219.24 |
| 9 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :
(b) On steel or other metal surface
With super gloss (hi-gloss) -
(iv) Two coats (with any shade except white) | 7.56 | Sq.m. | 79 | ₹597.24 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.94 MB
2911-ii.pdf
Tender Documents • 0.58 MB
BOQ_5084322.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].