Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.6 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹31.5 L+₹2.0 L (6.67%)Rejected-Finance VILL JASSAI DISTRICT BARMER RAJ 344001 | JASSAI | BARMER | RAJASTHAN | 344001 | L2 | Rejected-Finance Highest | |
| 3 | L3₹36.2 L+₹6.7 L (22.5%)Rejected-Finance S O KALA RAM C O LALIT AND BROTHERS UTARLAI UTTARLAI VPO UTTARLAI BARMER RAJASTHAN 344001 | BARMER | RAJASTHAN | 344001 | L3 | Rejected-Finance Highest | |
| 4 | L4₹37.1 L+₹7.6 L (25.6%)Rejected-Finance 205 IIND PHASE INDUSTRIAL AREA BARMER 344001 | BARMER | BARMER | RAJASTHAN | 344001 | L4 | Rejected-Finance Highest | |
| 5 | Rejected-Technical | - | Rejected-Technical REJECTED |
Tender Value
₹29.1 L
EMD Value
₹58,300
Closing Date
19 Dec 2023, 6:00 pmClosed
GE ARMY BARMER
Military Engineer Services, Jalipa Military Station, Garrison Engineer (Army), Barmer, PIN 344001
SPL REPAIR TO GUARD POSTS TOILET BLOCKS AND OLD UNSERVICEABLE LIGHTNING CONDUCTOR EARTHING AND CONNECTED ACCESSORIES AT MIL STN JASAI UNDER GE ARMY BARMER
2023_MES_627392_1
8737/E8
Open Tender
Civil Works
Item Rate
240 days
GE ARMY BARMER
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ARMY BARMER
₹58,300
2 Feb 2024
8 Nov 2023
26 Dec 2023
8 Nov 2023
19 Dec 2023
22 Nov 2023
Amount
Taking up or down existing GI Tubing15 mm dia & connections including cleaning for Refixing or removal to store complete all as specified and directed
Taking up or down existing GI Tubing 20 mm dia & connections including cleaning for Refixing or removal to store complete all as specified and directed
Taking up or down existing GI Tubing 25 or 32 mm dia & connections including cleaning for Refixing or removal to store complete all as specified and directed
Refixing old GI water tubing of 15 mm bore, including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors complete all as specified and directed.
Refixing old GI water tubing of 20 mm bore, including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors complete all as specified and directed.
Refixing old GI water tubing of 25 or 32 mm bore, including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors complete all as specified and directed.
S&F 15 mm bore galvanized iron tube medium grade with all fittings such as bends, elbos , socket, reducer and fixed to wall, ceiling or laid in floors complete all as specified and directed.
S&F 20 mm bore galvanized iron tube medium grade with all fittings such as bends, elbos , socket, reducer and fixed to wall, ceiling or laid in floors complete all as specified and directed.
S&F 25 mm bore galvanized iron tube medium grade with all fittings such as bends, elbos , socket, reducer and fixed to wall, ceiling or laid in floors complete all as specified and directed.
Dismantling of existing water tanks capacity n exc 500 ltr and removing to store complete all as specified and directed
S&F rotational moulded polethylene water tank of 500 ltrs capacity ( cylindrical vertical with closed top) hoisted and fixed in position all as pacific SSR Part- I , including ball valves 20mm high pressure PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed ( min wt.15mm-142gms/20mm-210gms,25mm-455gms,40mm-690 gms ) complete all as specified and directed.
S&F in repair 15 mm dia bib tap,fancy type chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair 15mm bore pillar tap cast copper alloy fancy type with capston heads, chromium plated screwed down high pressure, with or without letters Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipes and fixed complete all as specified and directed.
S&F in repair 15mm bore stop valves ,fancy type,with long shank and cup(concealed type), screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repair 20 mm dia gun metal , globe or gate valves, with iron wheel head , screwed both ends for iron pipe complete all as specified and directed.
S&F in repair bib taps 15mm bore standard of PTMT any colour high pressure screwed for iron pipe and complete all as specified and directed. (minimum wt. 90gms)
S&F in repairs chromium plated swivel shower roses with or without swivel joints, for fixing with 15mm pipe complete all as specified and directed.
S&F in repair PVC connection 15mm bore length not less than 450 mm long with both ends PTMT nuts complete all as specified and directed.
S&F in repair vitreous china wash down water closet pan pedestal pattern white including connection in drain and in flushing pipe complete including 'P' or 'S' trap and including plastic water closet seat cover with flat bottom and cover with MS Chromium plated hinge divice ISI marked complete all as specified and directed.
S&F in repair Vitreous China urinals,half stall ,complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets,flush pipe, grating and Union for discharge pipe complete all as specified and directed. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)
S&F in repair vitreous china wash basin white, flat, back, size 550x400 mm excluding tap waste but including brackets and including cutting for and pinioning in ends of brackets but exclusive of supply waste pipecomplete all as specified and directed.
Supply and fix in repair 10 ltrs PVC valveless syphonic action type flushing cistern low level white , with inlet ball valve, float and handle including bracket with 32 mm dia PVC pipe 600 mm long complete all as specified and directed.
Cutting chases, pinning in making good to facing on brick walls & pointing in CM 1:3 for concealed water tubing cutting n exc 10 cm girth complete all as specified and directed.
Taking down chowkat or frames with shutters (without taking off shutters from the frames) area not exc 1.5 Sqm each and removing from site complete all as specified and directed.
Taking down chowkat or frames with shutters (without taking off shutters from the frames) area exc 1.50 sqm not exc 4.00 Sqm each and complete all as specified and directed.
Taking down shutters of any description exc 1 sqm but not exc 2 sqm each and complete all as specified and directed.
S&F Steel windows or ventilators, fixed type, with glazing bars, complete all as specified and directed
S&F factory made steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay complete with glazing bar, dovetailed or welded complete all as specified.
S&F galvanized mild steel wire cloth 0.50mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanized wire staples complete all as specified and directed.
M&L 10-12 mm square bar in MS framed guard bars confirming to grade Fe-290 welded to steel ventilators complete all as specified and directed.
Preparation of new or previously untreated steel surfaces and apply two coat of synthetic enamel paint over one coat of Red oxide primer on surfaces of steel, over 10cm in width or grith, not other wise described complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube, supplying and fixing in opening as specified and as per drawing complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30mm thick (style) consistiing of frame made out of MS tubes for top and bottom rail MS frame, shall be covered with heat moulded channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side and as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fited in the MS frame welded / sealed to the stiles and rails with suitable PVC sheet beading, and joined together with solvent cement, suppling and fixing in the frame at site as per specification and drawing complete all as specified and directed.
S&F 100mm size MS hinges and fixed to PVC frame and angle iron frame by necessary welding complete all as specified and directed.
S&F extracted aluminum alloy handle fabricated type anodized, 150mm size complete all as specified and directed.
S&F 300 mm long aluminium sliding door bolt, anodised,with hasp,staple(bolt type) and fixing clips of sheet,cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
S&F aluminum anodized barrel tower bolts extruded section, 150mm size complete all as specified and directed.
S&F second class hard wood 35mm gauged and skeleton shutter factory made without sash bars open rebated and prepared to receive gauge etc. top, bottom and lock rail, styles, edges of framing champhered or rounded fitted with cut and mitered wooden beads for securing glass, etc size of members of shutters as specified in SSR Part-I, Section 8, Clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed
S&F factory made second class hard wood plain framed panelled shutter (Two panel) with lock rail and pannel of 9mm thicks BWP commercial ply or 12mm veneered parlide board with commercial vereered on both faces the size of rails and style as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated 35mm thick complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description, over 10cm in width or girth, not otherwise specified with two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
S&F 140 mm floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring ,fixed in floor complete all as specified and directed.
S&F sheet glass, ordinary quality 3mm thick fixed with oil putty size of glass not exceeding 0.50 Sqm in each pane complete all as specified and directed.
S&F in repairs Harrison rails, mild steel, chromium plated with fixing brackets,stops,rollers etc complete all as specified and directed
Demolition of concrete in ground floors and paving n exc 15cm thickness (below or above ground level ) complete all as specified and directed.
M&L 100mm thick cement concrete type D-2, 1:4:8 (40mm graded crushed stone aggregate) finishing cement concrete surface even and smooth without using extra cement as specified and directed.
M&L 50 mm thick cement concrete type B-1, 1:2:4 ( 20mm graded crushed stone aggregate) finishing cement concrete surface even and smooth without using extra cement as specified and directed.
M&L 25 mm thick cement concrete type B-0, 1:2:4 ( 12.5mm graded crushed stone aggregate) as sub base of kota stone flooring finishing cement concrete surface even and smooth without using extra cement as specified and directed.
M&L for 75mm thick plain cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection finished even and smooth without using extra cement, including making joints to the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen and sand 1:2 by weight complete all as specified and directed.
M&L for 20-25 mm thick machine cut kota stone slab flooring set and jointed with grey cement slurry mixed with pigment to match the shade of the slab including 20 mm thick screed bed in cement mortar 1:4, rubbing, polishing complete including demolition of stone slabs and tiles of any description or thickness in floors aprons etc laid bedded and pointed in any mortar complete all as specified and directed.
M&L kota stone slab skirting 20-+25mm thick over cement screed laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete inlcuding 10 mm thick rendering in vertical surface of brick / PCC block wall in cement mortar 1:4 and including demolition of old kota stone dedo complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding, removing serviceable tiles to stores and removing debris outside the MD land complete all as specified and directed.
S&F ceramic White tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
S&F Glazed ceramic white tiles 350 x 250 x 7mm /450 x 350 x 7mm thick, in vertical surfaces and such as skirting, dados and riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match inluding 10mm thick screed bed in CM 1:4 complete all as specified and directed.
Taking down cement plaster on stone masonry/Brick Masonry incl racking out joints, hacking for key scrubbing down with water complete all as specified and directed.
M&L for 15 mm rendering in CM 1:4 on fair face of wall or on concrete surfaces finished even with water proofing compound (WPC) and smooth without using extra cement complete all as specified and directed. (WPC Measured seprately)
Supply only liquid water proofing compound. (For external new plaster surfaces)
M&L for 15 mm rendering in CM 1:6 on fair face of wall or on concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for 5 mm rendering in CM 1:4 on fair face of ceiling or on concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for Preparing new surface of wall (plastered) and applying Two coat of white Wash on wall of approved tints complete all as specified and directed.
M&L for Preparing of new plastered/unplastred surfaces of walls and applying Two coat of cement base paint over one coat of Primer as camouflage pattern complete all as specified and directed.
M&L for Preparing New plaster surface washing rubbing down and complete removal of existing treatement of Ceiling and applying Three coat of White wash on ceiling of approved tints all as specified and directed.
M&L for Preparing of old painted surfaces of walls or roofs by brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salt and greasy spots and applying one coat of cement base paint as camouflage pattern complete all as specified and directed.
M&L for Preparing old plaster surface of wall (plastered) washing, rubbing down and stopping of distempered, printed surfaces and complete removal existing treatement applying Two coat of White wash on wall of approved tints all as specified and directed.
M&L for Preparing old plaster surface washing rubbing down and complete removal of existing treatement of Ceiling and applying one coat of White wash on ceiling of approved tints complete all as specified and directed.
Demolition of cement concrete (unreinforced) in roofs, floors (other than ground floors) beams, staircases,landing, chajjas and similar suspended work complete all as specified and directed.
M/L plain cement concrete 1:2:4 type B1 using 12.5 mm graded aggregate as in roof for maint. the uniform slope etc any thickness at any height and in any position complete all as specified and directed.
M&L APP based polymeric modified membrane minimum weighing not less than 3kg / Sqm and minimum 3mm thick reinforced with polyester non woven fabric weight not less than 150 gms / Sqm and on primed surface of one coat of approved bituminous [email protected] Ltr per Sqm by torch application method with 150mm over lap on length side & 100mm on width side complete all as specified and directed.
M&L Cement concrete tiles 20cm x 20xm x20mm thick, machine pressed; set, jointed and pointed in net cement shurry with grey cement and no pigment in Roof (Over 15 mm thick Screed bed CM 1:6) and cut and polished complete all as specified and directed.
Supply only water proofing compound (ISI Marked)
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth, for foundation, laying of sewar line etc. and getting out in any type of soil complete all as specified and directed.
Excavation over areas, n exc 1.5 m deep and getting out in any type of soil complete all as specified and directed
Excavation over areas, exc 1.5 m and n exc 3 m depth and getting out in any type of soil complete all as specified and directed
Returning, filling in, including spreading, leveling, watering and well ramming in layer not exceeding 25cm thick in any type of soil complete all as specified and directed.
Removal of excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of any dia, set in cement mortar including PCC in bed and haunching against side including removing debris and rubbish outside MD land complete all as specified and as directed.
S & F 150 mm bore Reinforced cement concrete pipes, with collars, class NP2, laid in trenches and jointed complete all as specified and as directed .
M&L PCC 1:4:8 type D-2 by using 40 mm graded crused stone aggregate as in bed to 150 mm bore salt glazed stone ware drain pipe or reinforced concrete drain pipes, including packing under and haunching against the side of pipe after they are laid and tested complete all as specified and directed .
M&L PCC 1:4:8 type D2 by using 40mm graded stone aggregate as in foundations filling and mass concrete complete all as specified and directed.
Demolition of stone / boulder masonry walling built in cement mortar including all quoins arches pillars etc and removal unserviceable materials, debris, rubbish to out side MD land complete all as specified and as directed.
M&L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM (1:4) complete all as specified as directed.
M&L Walling of random rubble masonary well bonded,bedded and solidly hearted built in cement mortar 1:4 brought up to courses except stone complete all as specified and directed.
Extra over stone walling for hammer dressing to face granite or trap stones with maximum depression on face from a straight edge held against the dressed surface not exceeding 20mm and dressing face beds and joints as specified of random rubble walling un-coursed or brought upto courses complete all as specified and as directed .
M&L PCC (1:2:4) type B-1 (using 20mm graded stone aggregates) as in coping,benching/channels of manholes including demolition of existing pcc etc complete all as specified and directed.
M&L rendering 15mm thick in CM 1:4 on stone masonry surfaces, finished even and fair without using extra cement mixed with water proofing compound as per manufacturer instructions complete all as specified and directed. Note :- WPC will be measured and paid seperately.
M&L for RCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in precast manhole/drain covers including demolition of RCC slab, manhole/drain cover in any position complete all as specified and as directed.
M&L in repair of PVC (SWR) 110 mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F in repair of stack clamps made out of 50 X 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 110mm bore pipes complete all as specified and directed.
S&F in repair of 110 mm bore PVC [SWR] vent cowl complete all as specified and directed.
Demolition of reinforced cement concrete on roofs,floors ( other than ground floors), beams, staircase, landing, chajjas and similar suspended work complete all as specified and directed.
M&L form work to soffits of suspended slabs such as roof slab landings and similar works n exc 100mm thick (horizontal or slopping) fair finished surfaces of concrete flat complete all as specified and directed.
M&L form work to edges of concrete flates ,treads break in floors ,window cills ,concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sisides of RCC/PCC bands in walls, horizontal or sloping and ssimilar work exc 10 cm but n. exc 20 cm wide rough finished surface of concrete complete all as specified and directed.
M&L Nominal mix reinforced cement concrete type B1 (1:2:4) using 20 mm graeded stone aggregate as in roof slabs supported on walls surfaces of concrete flat complete all as specified and directed.
M&L TMT bars 10 mm and over cut to length, bent to shape required incl cranking, bending spirally for hoping for columns hooking ends and bindind with MS wire (annealed) not less than 0.9mm dia quality confirming to complete all as specified and directed. (GRADE FE-410-W,Gde.E-250 quality-A )
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors, etc complete all as specified and directed.
Taking down carefully old unserviceable burnt MCB DB with MCBs and keeping in safe custody for issuing under Sch of creditc omplete complete all as specified and directed..
M/L Point wiring complete with 1100volt grade PVC insulated unsheathed multistranded 1.5 sqmm copper conductor cable confirming to IS 694 FRLS drawn through and including rigid PVC casing and capping medium grade of size 25/20 mm, etc fixed on wall/ceiling including provision of 1.5 sqmm PVC unsheathed copper conductor and connected to earth dolly, including provision of pressed steel terminal box with 3mm thick plastic laminated sheet top cover for housing switches sockets etc concealed on wall complete all as specified and directed. (a) one light point controlled by one, one way switch
All as per srl item No 97 above but for one ceiling fan/exhaust Fan point controlled by one, one way switch.
All as per srl item No 97 above but for one socket outlet 5 Amps on same board with other switches, with cables 1.5 sqmm size.
All as per srl item No 97 above but for one socket outlet 3 Pin 5 Amp on independent board, with cables 1.5 sqmm size.
All as per srl item No 97 above but for one 3 pin socket out let, 15 Amps, Independent Board with cables 4 Sqmm size along with 4.00 Sqmm earth wire.
S&F MCB DB SPN double door 8 way sheet metal enclosure SPN 240 V 50 Hz horizontal with IP-20 degree protection complete all as specified and directed.
S&F MCB DB SPN double door 4 way sheet metal enclosure SPN 240 V 50 Hz horizontal with IP-20 degree protection complete all as specified and directed.
M&L in repairs for MCB SPN 40 Amps 230 Volts C series complete all as specified and directed.
M&L in repairs for MCB SP 5-30 Amps 230 Volts C series complete all as specified and directed.
S&F in repairs Switch piano 5A one way 230 Volts surface mounting Flush type complete all as specified and directed.
S&F in repairs Switch piano 15A one way 230 Volts surface mounting Flush type complete all as specified and directed.
S&F in repairs socket outlet outlets multipurpose 2 in 1, 5A Flush type (ISI marked) complete all as specified and directed .
M&L in repairs socket outlet combination 5A/15A, 5 in 1, Flush type complete all as specified and directed.
S & F in repairs ceiling rose, two to three terminal /PVC/Polycarbonate, isolated body complete all as specified and directed.
S&F in repairs LED light fitting 1x10 watt bulk headsurface mounted,decorative oval bulk head edge lit LED luminaries comprising of high brightness LEDs etc complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed.
S&F in repairs lamp holder complete all as specified and directed .
S&F in repairs LED Lamp 9 W of make CG/BAJAJ/PHILIPS complete all as specified and directed .
S&F in repairs LED tube light fitting, single tube surface/ pendent mounting 1x20 watt complete with electronic LED driver etc complete with tube rod complete all as specified and directed.
S&F LED Street light 25W made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening seperate driver compartment with IP66 protection and other accessories fixing on wall with and including bracket and made out of 25 mm dia GI tube light grade 1.2 mtr bend to shape as required including 02 Nos MS clamp (FI 25 x 3mm) with nuts and bolt washer including taken done old light fitting complete all as specified and directed including testing complete.
S&F in repairs Exhaust fan 300mm sweep including provision of 3 core 23/0.0076 size flexible copper cable from ceiling rose to fan complete all as specified and directed. Make:- Havells or equivalent Bajaj
Dismantling and taking out old ceiling fan 1200/1400 mm sweep deposit in MES and supply and fix new ceiling fan BLDC 32 watt 5 star rating complete all as specified and directed.
Supply,install, testing and commissioning factory made LT feeder pillar (Kiosk) box made out of MS sheet , 200A rated, of size 0.45 x 0.45 x 0.45 mtr, CPRI approved , floor mounted, dust and vermin proof,front and rear operated door with necessary locking arrangement made of 50 x 6mm MS angle iron frame work and duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity screwed copper bus bar (200 Amp rating) with suitable size bolt and nuts, thimbles glands complete all as specified and directed.
Supply, laying, jointing, testing and commissioning 1100 volt grade heavy duty XLPE insulated LT under ground cable, sheathed, as per IS- 7098 (Part I) 1988, galvanized steel strip armoured heavy duty multi stranded aluminum conductor laid in trenches / passed through pipe/duct road crossing, fixed on poles/ wall with clamps made out of mild steel flat iron including fixing accessories like brass cable glands double compression type, lugs, nuts, bolts, washers etc of size 2 core 10 sqmm complete all as specified and directed
M&L for Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, erection of poles, struts/stays, leveling of yard etc not exceeding 10 M² on plan and not exceeding 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
M&L for unwashed river sand cushioning to U/G cable and punning for cushioning of cable 8cm below the cable and 15cm above cable complete all as specified and directed. Note :- Thickness after punning shall not be less then 18 cm. Punned thickness shall only be museared and paid.
M&L 40 to 50mm thick rough dressed Jodhpur type stone slab cover 25 to 30 cm wide and not less than 60 cm in length, laid dry abutting each other with gap between adjacent slab not exceeding 10 mm over under ground cable protection complete all as specified and directed.
M&L for Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soil complete all as specified and directed.
M&L for Removing of excavated soil not exc. 50 M from starting points complete all as specified and directed.
S& F in repairs to any type of light into Lithium base energy efficient integrated solar street light 12 watt in encases solar PV panel 25/30W monocrystallinn, Lithium battery 111/12.8V,15.4 AH with in built BMS, hogh brightness W-LED (140-160 1m/ watt) lamp, CRI 80, colour temperature 6500K, micro controller based charge controller cum +driver with automatic dimming function, dusk to down operation, LUX output 15-18( from 5-6mtr height) , working temperature (-) 10° c to (+) 55°c, weight 6-7 kg with adjustable MS clamp suitable for pole / wall mounting protection from short circuit, overload , reverse polarity and battery protections complete all as specified and directed Make : Crompton/Havells/Wipro
Earthing complete in repair with galvanised steel earth plate electrode size 600x600x6.0mm thick burried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised earth lead 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth wire protected by GI protection pipe medium grade 15mm dia connected to main earth wire on pole or control board and GI pipe light grade 20mm bore for watering, funnel with wire mesh. PCC chamber pit in PCC 1:3:6 type C-1, 40 mm thick precast RCC M-25 (design mix) cover reinforced with 8 mm dia TMT bars @ 10 cm C/C on both sides and handle, excavation and earth work in any type of soil and removal upto 50 m complete all as specified and shown in electric plate No.03 of SSR Part-I(2009), connecting to earthing test point all as specified and directed including testing on completion. NOTE: (i) The unit rate includes for protection pipe and earth lead upto 7.50 meter. (ii) Any variation in length of earth lead and protection pipe beyond 7.5 m shall be measured separately. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional height of watering pipe bends elbow etc shall be deemed to be included in the unit rate.
Dismantling the existing unserviceable GI tubings and Supply, laying and connection of GI pipe medium grade with all fittings laid in trenches including testing complete all as specified and directed of 50 mm dia size. Make : Jindal/Tata/Prakash/Surya. Note:- Excavation and earth work shall be measured and paid separately.
Dismantling the existing unserviceable GI tubings and Supply, laying and connection of GI pipe medium grade with all fittings laid in trenches including testing complete all as specified and directed of 25 mm dia size. Make : Jindal/Tata/Prakash/Surya. Note:- Excavation and earth work shall be measured and paid separately.
S&F gun metal, globe or gate valves, 25mm dia with iron wheel head, screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F gun metal, globe or gate valves, 50mm dia with iron wheel head, screwed both ends for iron pipe or for unions complete all as specified and directed.
M& L for Construction of brick masonry valve Pit of size 50x 50 x 75 cm (internal dimension) including MS sheet cover fabricated from 3 mm thick MS sheet and frame angle iron 40 mm x 40 mm x 6 mm with fixing arrangement, hinges and locking arrangement and painting two coats of synthetic enamel paint over a coat of red oxide primer including necessary earth work 150 mm thick PCC 1:4:8 type P-2 using 40 mm stone aggregate as in foundation brick work in CM 1:4 complete all as specified and directed.
M&L for making connection of GI pipe line from existing any size GI/CI/DI pipe line by cutting/ tapping/ drilling of bore of suitable size including clamps, bolts etc. and checking of flow complete all as directed and specified.
Taking down carefully from roof/wall of the building loose/hanging/de-shaped, aluminum strips of any size & type including unserviceable insulators etc complete all as specified and directed.
Refixing serviceable aluminum strips of any size as obtained from item above with poreclin insulators of 15 BMD size 'T' type placd not more than 50cm apart with screws/nut/bolts etc complete all as specified and directed.
S&F aluminium stip 25mm x3.15mm fixed with saddles & fixing screws of size not less than 4mm dia , 32mm long for roof conductors and down conduxctors above ground level with porcelin insulators of 15 BMD size 'T' type placed not more than 50cm apart with screws/nut/bolts etc complete all as specified and directed.
M&L for test point terminal block made of gun metal or phosphorus bronze size 75mm x 75mm x 25mm drilled and screwd including 4 nos, 8mm dia 25mm long Exagonal nut head brass screws, and screwed to wall for protection of test point including 80mm x 80mm x 40mm PVC box for Gun metalblock fix to the wall by means of screws and nuts including taking down old unsv test terminal point complete all as specified and directed.
M&L for Air termination, single pointed, Aluminium rod 12mm dia, 300mm long fixed with roof in and including all fittings, fixtures shaddles, insulators, etc including taking down unsv Air terminantion rod of any size complete all as specified and directed.
Taking down carefully from wall/surface of the building, loose/hanging/de-shaped, GI strip of any size or type including unsv galvanised iron pipe of any dia complete all as specified and directed.
Refixing serviceable GI Strips of any size as obtained from item above with GI pipe of any size on wall/ floor with clamps and nuts and bolts of suitable size etc complete all as specified and directed.
M&L for Galvanised Iron strip 32mm x6mm burried in ground/ PCC hard standing/ fixed on wall including all necessary excavation andearth work, connecting at ends, jointing etc complete all as specified and directed.
M&L for replacement of unsv plate earthing with bore well earthing by drilling bore with bore machine for poles and other machinery / eqpt using GI pipe heavy duty 50 mm dia as earth electrode driven up to a depth of 50 meters below ground level, duly made holes at 20 cm intervals, along the length of GI pipe and providing the charcoal salt mixture incl GI pipe 150mm dia light grade as protection up nto a depth of 12 meters and GI strip of 32x6 mm so as to acheive desired earth results. Testing and commissioning complete all as specified and directed. (Earth strip of size 32x6mm upto a length of 7.5m is deemed to incl in this item rate).
m/s jogaram sujaram
Lalit and Brothers
National Rewinding Works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .