Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAccepted-AOC | ₹19.5 L | L1 | Accepted-AOC valid |
| 2 | L2₹25.0 L+₹5.5 L (27.9%)Rejected-Finance 140 DEORISINGHPURA RANIPUR JHANSI JHANSI UTTAR PRADESH 284205 UDYAM UP 39 0007853 | JHANSI | UTTAR PRADESH | 284205 | ₹25.0 L+₹5.5 L (27.9%) | L2 | Rejected-Finance NOT BEING LOWEST |
| 3 | L3₹25.1 L+₹5.6 L (28.5%)Rejected-Finance RCP GURUDWARA ROAD WARD NO 29 SURATGARH SRI GANGANAGAR 335804 | SURATGARH | SRI GANGANAGAR | RAJASTHAN | 335804 | ₹25.1 L+₹5.6 L (28.5%) | L3 | Rejected-Finance NOT BEING LOWEST |
| 4 | L4₹42.2 L+₹22.6 L (116.1%)Rejected-Finance | ₹42.2 L+₹22.6 L (116.1%) | L4 | Rejected-Finance NOT BEING LOWEST |
| 5 | Rejected-Technical NEAR S B O P WARD NO 1 SURDULGARH MANSA | SURDULGARH | MANSA | - | - | Rejected-Technical Not recommended due to non enlisted in Cat. i.e. b(ii). |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
22 Dec 2020, 6:00 pmClosed
GE AF SURATGARH
GE AF SURATGARH
MANNING AND OPERATION OF MRS AND MAFI SUB STATION DG SET AT AF STN SURATGARH
2020_MES_396850_1
8828/E8
Open Tender
Civil Works
Item Rate
334 days
GE AF SURATGARH
AS PER TENDER DOCUMENT
10 documents required · 10 mandatory
₹500
Yes
GE AF SURATGARH
₹80,000
Yes
2 Feb 2021
20 Nov 2020
25 Dec 2020
20 Nov 2020
22 Dec 2020
8 Dec 2020
Amount
BOQ (MANNING AND OPERATION OF MRS AND MAFI SUB STATION/DG SET AT AF STN SURATGARH)
Operation and maintenance of Main Receiving Station round the clock each day including Sunday and Holiday including repair with all consumable stores such as fuse wire of all sizes as per load requirement in MRS, MAFI Panel Room and distribution transformer , mineral jelly, carbon remover chemical (not major assemblies items) complete all as specified and as directed by Engineer-in-Charge. Electric supply received from JVVNL (Jodhpur Vidyut Vitran Nigam Limited) and further distribution to 11 KV through step down transformer comprising the following equipments shall fall in the scope of work for this item :- (Total 03 shifts with one electrician in each shift and 03 shifts with one MATE (Helper) in each shift of 8 hrs each round the clock including Sundays and Holidays.) (a) Transformer step down 33 KV/11 KV of capacity 3.15/ 5 MVA - 02 Nos. (b) HT OCB/VCB 11 KV installed in the whole AF station including 275 SU (c) GOD switch 33 MV - 04 Nos. (d) Transformer step down 11 KV/440 Volt installed in the whole AF station including 275 SU. (e) LT control panel , APFC - 02 Nos. (f) Operation of GOD switch 11 KV manual Installed in the whole AF Stn Suratgarh. (g) 33 KV VCB - 01 No (h) 5 MVA Autometic Voltage Regulator (j) 2400 KVAR HT Capacitor Panel (k) 160 KVA diesel driven DG set water cooled driven coupled with alternator AMF Panel (COMN IT)
Note for serial Item No 1.00 :- (i) Maintenance of 33/11 KV Main Receiving Station shall be as per periodic maintenance viz. daily, monthly, quarterly & one time job. (ii) Contractor shall ensure proper voltage and electric supply from JVVN Ltd. and liaise with them for any break down, contractor/staff on duty will inform to GE, AGE E/M or JE E/M in case of break down. (iii) Spare parts except consumable stores shall be issued by department on free of cost.
Manning and operation including minor repair with all consumable & spares parts (not major assemblies/items) & periodical maintenance of one No 125 KVA diesel driven DG set water cooled driven coupled with alternator AMF panel at New DSS, complete all as specified and as directed by Engr-in-Charge. (Total 03 shifts with one FGM in each shift of 8 hrs each round the clock including Sundays and Holidays)
Manning and operation including minor repair with all consumable & spares parts (not major assemblies/items) & periodical maintenance of MAFI Substation No 2 consisting of 160 KVA diesel driven DG set water cooled driven coupled with alternator AMF Panel, complete all as specified and as directed by Engr-in-Charge. (Total 03 shifts with one FGM in each shift of 8 hrs each round the clock including Sundays and Holidays)
Manning and operation including minor repair with all consumable & spares parts (not major assemblies/items) & periodical maintenance of one No 50 KVA diesel driven DG set and one No 82.5 KVA DG set water cooled driven coupled with alternator AMF panel at 23 ORP End, complete all as specified and as directed by Engr-in-Charge. (Total 03 shifts with one FGM in each shift of 8 hrs each round the clock including Sundays and Holidays)
Manning and operation including minor repair with all consumable & spares parts (not major assemblies/items) & periodical maintenance of one No 50 KVA diesel driven DG set water cooled driven coupled with alternator AMF panel at 05 ORP End, complete all as specified and as directed by Engr-in-Charge. (Total 03 shifts with one FGM in each shift of 8 hrs each round the clock including Sundays and Holidays)
Operation & periodical maintenance (as specified) of filtration plant at swimming pool comprising of filtration plant, motor pumps, connected valves, chloronomes and other related equipment/switch gears for smooth functioning of all equipments including comprehensive maintenance of swimming pool including filtration plant, motor pumps, connected valves, chloronomes and other related equipments/switch gears as and when required daily including on sunday and holidays for smooth functioning of swimming pool complete all as specified and directed by Engineer-in-Charge. (Total 02 shifts with one FGM in each shift of 8 hrs each including Sundays and Holidays) Notes:- (i) Serviceability state of all the equipments at filtration plant and chemical ratio of water in swimming pool to be recorded daily in the register and submitted for inspection all as specified and directed by Engr-in-charge. (ii) Failure/unserviceability of any equipment at the filtration plant shall be informed in writing to the department immediately. (iii) Cost for entire job shall be deemed to be included in the quoted rates of the items. (iv) The job includes cleaning and maintenance of swimming pool daily to achieve desired clarity of water in the pool using suction sweeper, nylon net and cleaning agents/chemical. (Cleaning agents/chemicals shall be issued by the department as required at site daily). (v) Cost of consumables and maint items below Rs. 100/- each is deemed to be included in the rates quoted. (vi) The maintenance shall be carried out as specified in particular specifications and record shall be maintained duly signed by representatives of contractors, MES and user in charge of swimming pool.
Note for Serial item No 1.00 to 6.00 :- Rate quoted by the contractor shall deemed to be inclusive of following :- (a) DG set comprising DG set shall be comprising complete set including alternator, motor AMF panel etc & other connected items for smooth & efficient performance through out the period. (b) Specific duty of the person to be employed by the contractor shall be to assist the electricians on duty in maintaining and operating the equipments. (c) Attending and rectification of breakdown of OH lines /Under ground cables in feeder complete upto distribution transformer installed including replacement blown of fuses. (d) Replacement/Maintenance of any electrical items/fittings fixtures/DBs including isolators and MCBs and MCCBs all as directed by Engineer-in-charge. Note any item/material shall be issued free for fixing. (e) Claiming and maintaining the HT Switch yard both 33 and 11 KV (sub station) and removal of any type of vegetation. (f) Recording hourly and periodical reading as per log sheet. (g) Maintenance of battery bank of auxiliary supply. (h) Maintenance of power factor shall be responsibility of contractor. Any Change in power factor will be informed to JE (E/M), AGE E/M and GE with in 03 Hours of incident.
Note for Serial item No 1.00 to 6.00 Contd/.... (j) Calibration of CT/PT and VCB kept at MRS shall be done minimum four times as directed by Engineer-in-charge. (k) Maintenance shall be as per periodical maintenance schedule (i.e. daily weekly, monthly, seasonal) (l) The attendance register of Power house/DG set operators will be submitted by the contractor on monthly basis to GE with signature of Engineer-in-charge and JE concerned (m) Log sheet of power house/DG sets daily maintained as per prescribed format will be submitted to E/M sub division of daily basis duly signed by the concerned users. (n) The contractor will ensure daily cleaning of plants room and surrounding area of the installation ie 05 meter along and for all fanced installation within the installation fance. (o) The operation and Maintenance includes replacement/fixing of minor spare of the installations fance. (p) Any damage to machinery/equipment due to wrong handing, will be the responsibility of the contractor and the damage shall be completely rectified to the entire satisfaction of Engineer-in-charge (q) In case of any damage misuse mishandling of govt property, contractor will be held responsible for the same.
Note for Serial item No 1.00 to 6 Contd/.... (r) Medical needs to be provide by the contractor to the employees as and when required. (s) All safety equipments such as breathing apparatus safety belt air hose respiratory, potable lighting eqpt etc for working hazardous condition to be probide by contactor (t) Contactor will provide reliver for weekly rest at all installation by providing one reliever of same trade. (u) It is the responsibilities of Contractor to maintain the required humidity and temperature. (v) Proper uniform, label containing name plate of the operator and safety shoes as approved by Engineer-in-Charge shall be worn by operator on duty. If any operator found in improper uniform and or found without proper name plates contractor shall be liable to pay penalty at the rate of Rs 150.00 per shift of 8 hours per person. (w) Proper facilities for sitting/ rest area shall be the responsibility of contractor.
Note for Serial item No 1.00 to 6.00 Contd/.... (x) Operator on duty shall not be allowed to leave the installation without reliever. Any operator found absent from duty a recovery of Rs. 150/- per day per installation for the period of absent will be made from the contractor. (y) First aid box kit with required medicines will be properly maintained by the contractor at all installations. (z) Generator set will be operated on the failure of electricity supply or as directed by Engineer in Charge. Contractor shall be responsible for removal of minor faults such as air lock in fuel supply, leakage of fuel, cleaning of fuel tank, tightening of connections of batteries, dynamo and self starter etc. (aa) All the installations will be maintained neat and clean with removal of grass/ bushes on daily basis. (ab) Contractor will submit details of deployed manpower along with qualification certificate such as matric & ITI certificate for ITI qualified personnel and matric certificate along with experience certificate for five years for skilled personnel, within fifteen days from the date of commencement of work to GE duly verified by Engineer-in-Charge. A minimum ratio of one is to three be maintained for ITI qualified personnel to skilled tradesmen. Contractor shall be liable to pay penalty at the rate of Rs 100.00 per person per day if required qualification certificates of deployed manpower not submitted after fifteen days from the date of commencement of work.
Note for Serial item No 1.00 to 6.00 Contd/.... (ac) Duty roaster for deployment of manpower installation wise will be prepared by the contractor and submitted to Engineer-in-Charge for verification. (ad) The payment of contractor’s employees will be made through Nationalized bank account of individual only. Contractor shall submit the payment proof i.e. passbook of bank account (showing the payment entry of every month from the date of commencement onwards till completion of work) at the time of submission of RAR and final bill. Contractor’s shall ensure minimum fare wage as applicable and shall be paid to his employees and proof of payment duly verified by Engineer-in-Charge shall be submitted at the time of submission of RAR and final bill. No RAR/Final bill will be paid without submission of proof of payment. (ae) Contractor shall upload copy of registration certificate of his firm with Employee Provident Fund organization while uploading of tender documents. It is a mandatory requirement and tender will be rejected in case of non submission of EPF registration certificate. Contractor will maintain all necessary documents regarding deposit of Provident Fund of employees during currency of contract period. It will be the responsibility of contractor to follow the rules and regulations of Employee Provident Fund organization strictly.
Note for Serial item No 1.00 to 6.00 Contd/.... (af) Contractor will be responsible for collection and consumption of fuel. for running of DG Set in AC Plants while Break Down of electricity supply. Transportation of fuel shall be the responsibility of contractor. Proper record/ log book of running of DG set shall be maintained by the contractor duly singed by JE and Engineer-in-Charge. Any consumption without run of DG Set will be recovered at double the market rate from contractor’s dues. Fuel shall be issued through issue vouchers duly signed by contractor and concerned staff at the time of collection of POL.
Contract Amount shall be derived after affecting the amount of Schedule of Credit in General Summary on serial page No 15 of tender documents.
M/s Tiwari and Sons
SRI SAI CONSTRUCTION COMPANY
GURDEEP SINGH AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .