Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAccepted-AOC | L1 | Accepted-AOC DUE TO L1 RATE | |
| 2 | L2₹12.7 L+₹64,438.50 (5.33%)Rejected-Finance | L2 | Rejected-Finance Due to higher rates | |
| 3 | L3₹13.2 L+₹1.2 L (9.58%)Rejected-Finance PO LEKHAPANI DIST TINSUKIA PIN 786 180 ASSAM | 786180 | L3 | Rejected-Finance Due to higher rates |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
26 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE LEKHAPANI
TINSUKIA, ASSAM
REPAIRS TO ROOF SHEETS, LEAKAGES/ SEEPAGES, JOINERY, PLUMBING AND MISCELLANIOUS REPAIRS IN ZONE-I, ZONE III, ZONE IVA AND ZONE IVB OF VARIOUS UNITS AT LEKHAPANI MIL STN
2022_MES_555008_2
8700/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE LEKHAPANI
Class E and category a (i)
4 documents required · 4 mandatory
₹500
GE LEKHAPANI
₹24,000
Yes
19 Dec 2022
3 Nov 2022
1 Dec 2022
3 Nov 2022
26 Nov 2022
12 Nov 2022
Amount
Taking down chowkat or frame with shutters (without taking off shutters from the frame) not exceeding 1.5 sqm each and making good to disturbed surfaces ie Jambs/sill and sides with suitable mix of PCC (1:3:6) and CM (1:4) and finishing the surfaces with existing finishes etc and complete all as specified and as directed by the Engineer-in-Charge.
Taking down chowkat or frame with shutters (without taking off shutters from the frame) exceeding 1.5 sqm but not exceeding 4.0 sqm each and making good to disturbed surfaces ie Jambs/sill and sides with suitable mix of PCC (1:3:6) and CM (1:4) and finishing the surfaces with existing finishes etc and complete all as specified and as directed by the Engineer-in-Charge.
S & F Aluminum powder coated (powder coated of required colour minimum thickness of powder coating 50 micron)) three track (2 Nos Glazed shutter & 1 Nos Gauzed shutter) sliding windows frame top & sides of size 92 x 31.75 x 1.30mm (section No 20621) bottom of size 92 x 31.75 x 1.30mm (Section of 20620) and shutter top & bottom of size 40 x 18 x 1.29 (section 20846) and lock side shutter frame of size 40 x 15 x 1.29mm (Section 20845) with rubber gasket, beading and locking arrangement including making good to the disturbed portion complete including stainless steel wire mesh 0.36mm nominal dia with 1.40mm average aperture and fixed with stainless steel wire staples and fixing 5mm thick glass with necessary rubber beading gasket etc complete all as specified and as directed by the Engineer-in-Charge.
S & F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, complete all as specified and as directed by the Engineer-in-Charge.
S & F aluminium Powder coated (minimum thickness of powder coating 50 micron) frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed by the Engineer-in-Charge.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots, Handles, tower bolt, floor stopper and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws,etc complete all as specified and as directed by the Engineer-in-Charge.
S&F Aluminium (Die cast ) body Door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed complete all as specified and as directed
S & F Aluminium Mortice lock vertical type size 100mm and 4 lever complete all as specified and as directed by the Engineer-in-Charge.
S & F 5mm thick Plain tinted glass ordinary quality complete all as specified and as directed by the Engineer-in-Charge.
S & F 3.5 mm to 5 mm thick composit panel of polyethylene core with two layer of aluminium skin each of min 0.25mm thick of any coloured as approved by Engr-in-charge all as directed.
Hacking out old broken glass (any thickness, size, quality or description), from wooden frames, glazed with putty or fixed with beads complete all as specified and as directed.
S&F 5 mm thick frosted sheet glass, ordinary quality and glazing with oil putty in squares n exc 0.5sq. m in each pane complete all as specified and as directed.
S&F 2.5 mm to 3 mm thick PVC transparent window panes ordinary quality and glazing with oil putty / wooden beads as required in squares n exc 0.5 sq. m in each pane complete all as specified and as directed by the Engineer-in-Charge.
S&F Framed work such as griils, grating, angle iron door frames etc., with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, laders, framed balusters, walk ways, railings frame work of water tanks and similar work conforming to Fe-290. Gde E-165 complete all as specified and directed.
S&F Stainless steel steel wire cloth. 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with steel wire staples complete all as specified and directed.
S&F Stainless steel steel wire cloth. 0.36 mm nominal dia of wire and average width of aperture 1.40mm fixed with steel wire staples as in repair with and incl 40X12 mm or 15 mm fillet of second class hard wood complete all as specified and directed.
Dismantling timber scantlings in unframed timber work 40 sq.cm and over in section, in any position complete all as specified and as directed by the Engineer-in-Charge.
M&L Second class hardwood, scantlings, wrought, fixed in unframed work complete all as specified and directed.
Demolition of wall and ceiling boards (fiber, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
M&L False ceiling with GI frame work for EXPOSED GRID SYSTEM of grid size 600 mm x 600 mm, GI powder coating at bottom and comprising of GI perimeter wall angle with two equal flanges of 25 mm fixed to surrounding wall / partition using nylon sleeves and screws at 450 mm centre to centre. Main Tee 0.55 mm thick having 35 mm wide flange and 25 mm high web suspended from the soffit @ 1200 mm centre to centre with with wire of 2.5 to 3 mm dia from purlin , Cross Tee - 1200, 0.55 mm thick having 35 mm wide flange and 25 mm high web inserted fixed into the slots of Main 'T' @ 600 mm centre to centre to form a grid of 1200 mm x 600 mm, Cross Tee - 600, 0.55 mm thick having 35 mm wide flange and 25 mm high web shall be placed perpendicular to the Cross Tee - 1200 to finally form a grid of 600 mm x 600 mm . complete all as per manufacturer instructions,l as specified and as directed by the Engineer-in-Charge.
S&F 4mm thick high pressure, oceanic pre-primed, self embossed, non asbestos fibre cement decorative board, water, termite and fire resistant for insulation and acoustic purpose to be placed in the grid system with provision of light fixtures, air conditioning, diffuser and ducts, sprinkler, smoke detector etc. complete all as per manufacturer instructions as specified and as directed by the Engineer-in-Charge.
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and as directed by the Engineer-in-Charge.
Dismantling of plain or corrugated steel sheeting any guage, thickness including Nanital or similar pattern roof coverings complete all as specified and as directed.
M&L for pre-painted hot dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50 mm thick of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed
M&L for hot dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50 mm thick of an approved colour and having yield strength of 550MPa as in ridge/valley/gutter/eaves boardings fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
S&F MS chromium plated curtain rod 25 mm dia with and including MS chromium plated decorative round finials on either end provide a visually balanced appearance including MS chromium plated brackets fixed to wall with 30 mm wooden steel screws and PVC rawl plug, anchors, and installation as in repairs complete all as specified and as directed by the Engineer-in-Charge.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facings, dressed stone work and precast concrete articles,removing debris to the premises, complete all as directed by Eng-in-charge.
M&L Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6m mean radius, built in CM ( 1:4) complete all as specified and directed.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water and removal of debris off the premises etc. complete all as specified and directed.
M&L Rendering 10.mm thick plaster in CM (1:6) on fair faces of brick work or concrete surfaces including finishing top even and smooth without using extra cement complete all as specified and directed.
M/L Rendering 15mm thick in CM (1: 4) on faces of brick work or concrete surfaces, finished fair and even complete all as specified and directed.
M&L Preparing new plastered or unplastered surfaces of walls and applying two coats of cement paint over a coat of primer complete all as specified and directed.
M & L Preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed.
M&L Preparing new wood and wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L Vitrified tiles of size 600mmx600mm 8 to 9 mm thick double charged in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including15 mm thick screed bed in CM (1:6) for laying floor finishes complete all as specified and directed.
M&L Vitrified tiles of size 600mmx600mm 8 to 9 mm thick double charged as in vertical surfaces such as skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering in CM (1:4) as backing coat complete all as specified and directed.
M&L Vitrified out door tiles of size 300mm x 300mm 9 to 10 mm thick (Capsule teracotta and Capsule Star Beige Pattern) as in floors, etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM (1:6) for laying floor finishes complete all as specified and directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar and removing debris to the premises,complete all as specified and directed.
S & F Factory made PVC solid door frame of size 50 mm x 47 mm with wall thickness of 5 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube throughout the frame and fixed to wall with 65/100 mm long mild steel screws through the frame by using PVC fasteners (minimum of 04 Nos. of screws to be provided for each vertical member & minimum 02 Nos. for horizontal member), complete all as specified.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, complete all as specified and as directed.
S&F 150 mm size, aluminium anodised , barrel tower bolts of extruded section and fixed complete all as specified and as directed.
S&F 100 mm butt hinges, type B-21, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed to PVC door complete all as specified and directed.
S&F 150mm size aluminium handles, cast type, anodized and fixed complete all as specified and directed.
RC CONSTRUCTION
RIA CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .