Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 LAccepted-AOC GUDSATHU BUDGAM KASHMIR 191111 J K | BUDGAM | BUDGAM | JAMMU AND KASHMIR | 191111 | L1 | Accepted-AOC Accepted Being L1 | |
| 2 | L2₹6.1 L+₹47,547 (8.50%)Rejected-Finance R O IQBAL MARKET AALI MAJID EIDGAH SRINAGAR KASHMIR | SRINAGAR | JAMMU AND KASHMIR | 190001 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹7.9 L+₹2.3 L (41.2%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹8.8 L+₹3.2 L (56.7%)Rejected-Finance | L4 | Rejected-Finance Other than L1 |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
21 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) CIF (K)
AGE (I) CIF (K) SHALATENG
PROVISION OF CERTAIN MINOR WORKS PERTAINING TO B/R AND E/M ATSHARIFABAD MIL STN UNDER AGE (I) CIF (K)
2021_MES_477276_1
CA NO. AGE (I) CIF (K) - 51/2021-22
Open Tender
Civil Works
Item Rate
180 days
SHALATENG
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
AGE (I) CIF (K)
₹16,000
Yes
30 Oct 2021
23 Sept 2021
23 Oct 2021
23 Sept 2021
21 Oct 2021
7 Oct 2021
60 days
Amount
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying of cable and foundation of poles, stays etc. n exc 10 sq m on plan and not exceeding 1.5 m in depth and getting out in hard/dense soil, complete all as specified and as directed by Engineer-in-Charge.
Plain cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete, complete all as specified as directed by the Engineer-in-Charge.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces, complete all as specified as directed by the Engineer-in-Charge.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions for fair finished surfaces, complete all as specified as directed by the Engineer-in-Charge.
TMT steel bars 10mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified as directed by the Engineer-in-Charge.
TMT steel bars 6 to 8mm dia in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified as directed by the Engineer-in-Charge.
Reinforced cement concrete (Design mix) in M -25 using 20mm graded crushed stone aggragte as in Columns, pillars, piers, posts and struts, complete all as specified as directed by the Engineer-in-Charge.
Preparation of new or previously untreated concrete surfaces of any description not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint, over 0ne coat of priming paint plaster coat, complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each layer in any type of soil complete all as specified and as directed by Engineer-in-Charge.
Removing excavated material not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and as directed by Engineer-in-Charge.
Brick work with sub class `B' bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6, complete all as specified and directed by the Engineer-in-Charge.
Rendering 15mm thick on brick work or concrete surface in cement mortar 1:4, finishing surfaces fair and even, complete all as specified and directed by the Engineer-in-Charge.
Plain cement concrete, 1:4:8, type D-2 using 40mm graded crushed stone aggregate, 75mm thick, as in sub-base of floor/path etc. finishing surfaces even and fair, complete all as specified and as directed by the Engineer-in-Charge..
Plain cement concrete, 1:2:4, type B-0 using 12.5mm graded crushed stone aggregate, 25mm thick, surface finished fair to receive top layer of flooring, complete all as specified and as directed by the Engineer-in-Charge.
Virified Ceramic tiles (Dark Shade) 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured, laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:6, complete all as specified and as directed by the Engineer-in-Charge. Note: Colour and shade of tiles shall be approved by AGE(I) and contractor shall not have any claim whatsoever on this account.
Glazed ceramic tiles, coloured, of size 450mm x 300mm thickness not less than 7mm as in vertical surfaces such as skirting/dado etc, set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match the shade of tile, fixed over and including 10mm thick rendering (bedding layer) on brick/concrete surface in cement mortor 1:4, complete all as specified and as directed by the Engineer-in-Charge. Note: Colour and shade of tiles shall be approved by AGE(I) and contractor shall not have any claim whatsoever on this account.
Point wiring with 1.5 sqmm copper conductor (Multistranded) PVC insulated and unsheatheted FRLS electric cable 1100 volts grade and including PVC casing caping/conduit pipe of suitable size with all fittings accessories and including PVC insulated electric cable 1100 volts 1.5 sqmm (multi stranded) copper conductor single core (Green colour) cable as continious earth wire connected to common earth dolly including sunk sheet terminal box made out of 1.6 mm thick MS sheet concealed on wall or on surface as per site requirement and making good distrubed surface of wall ,covered with 3 mm thick plastic laminated sheet for one light point/fan point/Bell point controlled by one,one way switch, complete all as specified and as directed by Engineer- In- Charge.
Piano type switch one way, SP, flush type, 5 Amps, 230 volts AC, 50 Hz, complete all as specified and as directed by the Engineer-in-Charge.
Ceiling fan complete with blades,,down rods,electronic regulator and accessories, 230 V, 1200mm sweep,,min air delivery 210cfm with service value 6.00 BEE,Five star rate, complete all as specified and as directed by Engineer-in-Charge. Make:- Havells/Usha/Orient/Bajaj
Ceiling rose surface type, 65 mm x 50 mm three terminals/PVC/polycarbonate, isolated body fixed on PVC block,complete all as specified and as directed by the Engineer-in-Charge.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 Sqmm, 4 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
Galvanized iron tubing 50mm bore light grade with all fittings,laid in trenches or under road crossing , or fixed alongwith poles/walls with clamps made of mild steel flat iron 25mm x 3mm including GI nuts, bolts and washers as protection pipe for cables and including taking down/out old existing pipe, complete all as specified and directed by the Engineer- in-Charge.
Sand cushioning to underground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable, complete all as specified and directed by Engineer-in-Charge. Note: Punned thickness of sand shall be measured.
Common burnt sub class ‘B’ brick laid flat in trenches over and across the length of cable with length of brick perpendicular to the direction of cable adjacent/abutting each other for cable protection, complete all as specified and as directed by Engineer-in-Charge.
Decorative gate light made upof high grade unbreakable polycorbonate material suitable for 20W LED lamp B22 basemounting on pole dia-60mm long, complete all as specified and as directed by the Engineer-in-Charge. Make:- Havells Cat part No LHFOGAEITIIFO15 equivalent in Bajaj/Philips
Note :- An amount of Rs. 790.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S SHIMAR STAR GLACIER
Javeed And Co
M/S YATTOO CONTRACTORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .