| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.0 LAccepted-AOC | ₹11.0 L Quoted ₹11.3 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹12.5 LRejected-Finance 702 A1 SHREE PRASAD TAWADEWADI SHREE DATTAGURU PARK KUMBHARWADA URAN DIST RAIGAD MAHARASHTRA 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | ₹12.5 L | L2 | Rejected-Finance BEING L2 |
| 3 | L3₹12.9 LRejected-Finance 0 H O SIDHARTH SHANKAR ROY DIGHA GHAT DIGHA PATNA BIHAR 800011 UDYAM BR 26 0085368 | PATNA | BIHAR | 800011 | ₹12.9 L | L3 | Rejected-Finance BEING l3 |
| 4 | L4₹13.0 LRejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | ₹13.0 L | L4 | Rejected-Finance BEING L4 |
| Sl No | Description | Qty | Unit | Sagar Electricals L2 | HINDUSTAN BUILDERS L4 | Vinod Enterprises L1 | M/S KHUSHI ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches, n exc 1.5 mtr wide and n,exc 1.5 mtr in depth; for foundation etc. or for shafts, wells cesspit, manholes, pier holes,etc n,exc 10 Sqm on plan and n exc 1.5mtr in depth and getting out as in soft/loose soil complete all as specified and directed by Engg-in-Charge. | 243 | CUM | 150 ₹36,450 | 240 ₹58,320 | 300 ₹72,900 | 350 ₹85,050 |
| 2.00 | Returning filling in including spreading leveling, watering and well ramming in layers not exe 25 cm each layer complete all as specified and directed by Engg-in-Charge. | 170.1 | CUM | 120 ₹20,412 | 50 ₹8,505 | 200 ₹34,020 | 200 ₹34,020 |
| 3.00 | Removing excavated material to a distance not exe 50 M and depositing where directed not exceeding 1.50 M above the starting point complete all as specified and directed by Engg-in-Charge. | 72.9 | CUM | 90 ₹6,561 | 50 ₹3,645 | 200 ₹14,580 | 200 ₹14,580 |
| 4.00 | M&L for spreading in trenches dry crushed Stone sand for cable protection and punning down gently by hand complete all as specified and directed by Engg-in-Charge. | 72.9 | CUM | 600 ₹43,740 | 1,200 ₹87,480 | 700 ₹51,030 | 700 ₹51,030 |
| 5.00 | Supply and laying unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mm laid in trenches complete all as specified and directed by Engg-in-Charge. | 5,921 | EACH | 15 ₹88,815 | 30 ₹1.8 L | 19 ₹1.1 L | 20 ₹1.2 L |
| 6.00 | Supply and fix Galvanized iron steel tubing Light grade of 80mm bore with all fittings as required at site and laid in floors/trenches as in cable protection complete all as specified and directed by Engg-in-Charge. | 30 | RM | 500 ₹15,000 | 700 ₹21,000 | 200 ₹6,000 | 400 ₹12,000 |
| 7.00 | Supply and fix Galvanized iron steel tubing Light grade of 50mm bore with all fittings as required at site and laid in floors/trenches as in cable protection complete all as specified and directed by Engg-in-Charge. | 30 | RM | 500 ₹15,000 | 400 ₹12,000 | 200 ₹6,000 | 350 ₹10,500 |
| 8.00 | Dismantling and Taking down L.T under ground armored PVC insulated and PVC sheeted heavy duty 1100 Volts grade under ground cable of any size and description complete all as specified and directed by Engg-in-Charge. | 1,020 | RM | 10 ₹10,200 | 5 ₹5,100 | 5 ₹5,100 | 10 ₹10,200 |
| 9.00 | Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm, 2 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc complete all as specified and as directed by the Engineer-in-Charge.
Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ. | 100 | RM | 100 ₹10,000 | 125 ₹12,500 | 130 ₹13,000 | 167 ₹16,700 |
| 10.00 | -ditto- all as per Item No -9 here in above but of size 10 sq mm 4 Core complete all as specified and as directed by the Engineer-in-Charge. | 100 | RM | 160 ₹16,000 | 125 ₹12,500 | 150 ₹15,000 | 236 ₹23,600 |
Updated dates
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
19 Jan 2026, 6:00 pmClosed
GE AF THANE
Office of Military Engineer Services ,Garrison Engineer (AF) Thane, Kolshet Road, Sandoz Baugh Post, Thane 400607
REPAIR/ MAINTENANCE OF LT CABLE , LT PANEL SWITCH GEARS AND CONNECTED WORKS AT DIFFERENT SUB STATION AT SION AND COLABA AREA UNDER AFS MUMBAI UNDER GE (AF)THANE
2025_MES_745670_1
GE (AF) T-51 OF 2025-26 (8557)
Open Tender
Electrical and Maintenance Works
180 days
THANE
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF THANE
₹30,000
Yes
24 Mar 2026
22 Dec 2025
26 Jan 2026
22 Dec 2025
19 Jan 2026
6 Jan 2026
Excavation in trenches, n exc 1.5 mtr wide and n,exc 1.5 mtr in depth; for foundation etc. or for shafts, wells cesspit, manholes, pier holes,etc n,exc 10 Sqm on plan and n exc 1.5mtr in depth and getting out as in soft/loose soil complete all as specified and directed by Engg-in-Charge.
Returning filling in including spreading leveling, watering and well ramming in layers not exe 25 cm each layer complete all as specified and directed by Engg-in-Charge.
Removing excavated material to a distance not exe 50 M and depositing where directed not exceeding 1.50 M above the starting point complete all as specified and directed by Engg-in-Charge.
M&L for spreading in trenches dry crushed Stone sand for cable protection and punning down gently by hand complete all as specified and directed by Engg-in-Charge.
Supply and laying unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mm laid in trenches complete all as specified and directed by Engg-in-Charge.
Supply and fix Galvanized iron steel tubing Light grade of 80mm bore with all fittings as required at site and laid in floors/trenches as in cable protection complete all as specified and directed by Engg-in-Charge.
Supply and fix Galvanized iron steel tubing Light grade of 50mm bore with all fittings as required at site and laid in floors/trenches as in cable protection complete all as specified and directed by Engg-in-Charge.
Dismantling and Taking down L.T under ground armored PVC insulated and PVC sheeted heavy duty 1100 Volts grade under ground cable of any size and description complete all as specified and directed by Engg-in-Charge.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm, 2 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc complete all as specified and as directed by the Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
-ditto- all as per Item No -9 here in above but of size 10 sq mm 4 Core complete all as specified and as directed by the Engineer-in-Charge.
-ditto- all as per Item No -9 here in above but of size 16 sq mm 2 Core complete all as specified and as directed by the Engineer-in-Charge.
-ditto- all as per Item No -9 here in above but of size 16 sq mm 4 Core complete all as specified and as directed by the Engineer-in-Charge.
-ditto- all as per Item No -9 here in above but of size 25 sq mm 3.5 Core complete all as specified and as directed by the Engineer-in-Charge.
-ditto- all as per Item No -9 here in above but of size 35 sq mm 3.5 Core complete all as specified and as directed by the Engineer-in-Charge.
-ditto- all as per Item No -9 here in above but of size 50 sq mm 3.5 Core complete all as specified and as directed by the Engineer-in-Charge.
-ditto- all as per Item No -9 here in above but of size 70 sq mm 3.5 Core complete all as specified and as directed by the Engineer-in-Charge.
Supply, install, testing and commissioning in repair of factory made and CPRI tested outdoor type floor mounted on PCC Plinth. LT panel board cubicle type panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 500 Amps fixed on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 3.0 mm CRCA sheet duly powder coated after seven tank process and pedestal of size 50 x 50 x 6 mm thick MS angle iron frame work. the panel shall be both front and back openable type adequate space all around accessories such as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade marked or PVC sleeved copper strips of appropriate size as per standard in practices and including comprising of followings accessories complete all as specified and directed by Engg-in-Charge. INCOMING:- (a) MCCB 415 Volts, 400 Amp, rating 4 Pole (triple pole and neutral), (Service Breaking Capacity 35 KA - 01 No (b)Digital volt meter 0-500 Volts-01 (c) Digital Ampere meter 0-100 Amps with and including CTs-01 No OUTGOING:- (a) MCCB 415 Volts, 125 Amp, rating 4 Pole (triple pole and neutral), (Service Breaking Capacity 25 KA - 02 Nos. (b) MCCB 415 Volts, 100 Amp, rating 4 Pole (triple pole and neutral), (Service Breaking Capacity 25 KA - 01 Nos. (c) Internal wiring of panel with stranded copper cable of suitable size (d) Neon phase indicating lamp(Set of three)-01 Set (e) Stencilling of panel board including marking of distributions
Supply, install, testing and commissioning in repair of factory made and CPRI tested outdoor type floor mounted on PCC Plinth. LT panel board cubicle type panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 400 Amps for phases The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 3.0 mm CRCA sheet duly powder coated after seven tank process and pedestal of size 50 x 50 x 6 mm thick MS angle iron frame work. the panel shall be both front and back openable type adequate space all around accessories such as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade marked or PVC sleeved copper strips of appropriate size as per standard in practices and including comprising of followings accessories complete all as specified and directed by Engg-in-Charge. INCOMING:- (a) MCCB 415 Volts, 250 Amp, rating 4 Pole (triple pole and neutral), (Service Breaking Capacity 35 KA - 01 No (b)Digital volt meter 0-500 Volts-01 (c) Digital Ampere meter 0-100 Amps with and including CTs-01 No OUTGOING:- (a) MCCB 415 Volts, 100 Amp, rating 4 Pole (triple pole and neutral), (Service Breaking Capacity 25 KA - 04 Nos. (b) MCCB 415 Volts, 100 Amp, rating 4 Pole (triple pole and neutral), (Service Breaking Capacity 25 KA - 01 Nos. (c) Internal wiring of panel with stranded copper cable of suitable size (d) Neon phase indicating lamp(Set of three)-01 Set (e)Stencilling of panel board including marking of distributions.
M & L for maintenance free chemical Gel based earthing, solid copper Pipe having 25 mm dia 3 mtr long copper pipe 25 Kg back fill compound including FRP chamber of suitable size and shape all as required at site including testing on completion and taking down of old earthing complete all as specified and as directed by Engineer.in.charge including FRP cover of suitable size. Note : (a) Earth resistance of earth pit should be less than 1.0 Ohms on testing after completion. If the desired earth resistance is not obtained the earthing will be redone at no extra cost . (b) Earthing strip will be measured and paid separtely under reapective item of BOQ.
S& F Copper strip 20 x 3.15mm from erthing pit to Test point terminal with saddles and fixing screws etc. all as per site requirment and as directed .
Material and Labour for repairing of LT Panel of not exc of sizes 2.5 Mtr x 2 Mtr x 0.80 Mtr doors/shuttering to welding and bracing of hinges, tinkering, and replace worn out rusted unserviceable doors/compartment shutters front sides and back side lock system including replace worn out rubber gaskets/feeding of compartment doors/shutters, decorbonising of all cable terminals, Busbars (R,Y,B &N) aluminium/copper cleaning inside of panel housing with help of air belower heavy duty complete all as specified and directed by Engineer-in-Charge.
Material and Labour for repairing of LT Panel of not exc of sizes 2 Mtr x 1.5 Mtr x 0.80 Mtr doors/shuttering to welding and bracing of hinges, tinkering, and replace worn out rusted unserviceable doors/compartment shutters front sides and back side lock system including replace worn out rubber gaskets/feeding of compartment doors/shutters, decorbonising of all cable terminals, Busbars (R,Y,B &N) aluminium/copper cleaning inside of panel housing with help of air belower heavy duty complete all as specified and directed by Engineer-in-Charge.
Material and Labour for repairing of feeder pillar box of not exc of sizes 2 Mtr x 1.5 Mtr x 0.80 Mtr doors/shuttering to welding and bracing of hinges, tinkering, and replace worn out rusted unserviceable doors/compartment shutters front sides and back side lock system including replace worn out rubber gaskets/feeding of compartment doors/shutters, decorbonising of all cable terminals, Busbars (R,Y,B &N) aluminium/copper cleaning inside of panel housing with help of air belower heavy duty complete all as specified and directed by Engineer-in-Charge.
S&F in repair LED indication lamp for indication of (R,Y,B) 230 Volts including connections and taking out unserviceable indication Lamp complete all as specified and directed by Engg-in-Charge.
S&F in repair Volt meter 0-500 Volt digital type including connections and taking out unserviceable Volt meter complete all as specified and directed by Engg-in-Charge.
S&F in repair Ampere meter 0-400Amps digital type including connections and taking out unserviceable Ampere meter complete all as specified and directed by Engg-in-Charge.
Supply and fix in repalcement of copper cable of size 10 Sqmm single core for internal connection inside feeder piller or panel from connector MCCB or MCBS or Contactor all as per existing including copper lugs for cable termination at both ends complete all as specified and directed by Engg-in-Charge.
Supply and fix cable jointing kit heat shinkable type suitable for LT cable 1100 volt grade cables of size up to size 4 core 25 Sqmm / 3.5 core 25 sqmm cable size all as per site requirement and as directed by Engg-in-Charge.
-ditto- all as per Item No -31 here in above but of size 3.5 core 35 Sqmm to 3.5 core 70 Sqmm.
-ditto- all as per Item No -31 here in above but of size 3.5 core 95 Sqmm to 3.5 core 120 Sqmm.
-ditto- all as per Item No -31 here in above but of size 3.5 core 150 Sqmm to 3.5 core 180 Sqmm.
Supply and fix aluminum cable lugs suitable for LT cable 1100 volt grade cables of size up to 4 core 25 Sqmm to 3.5 core 25 sqmm cable size all as per site requirement and as directed by Engg-in-Charge.
-ditto- all as per Item No -35 here in above but of size 3.5 core 35 Sqmm to 3.5 core 70 Sqmm.
-ditto- all as per Item No -35 here in above but of size 3.5 core 95 Sqmm to 3.5 core 120 Sqmm.
-ditto- all as per Item No -35 here in above but of size 3.5 core 150 Sqmm to 3.5 core 180 Sqmm.
Supply and fix cable double compression cable glands suitable for LT cable 1100 volt grade cables of size up to size 4 core 25 Sqmm / 3.5 core 25 sqmm cable size all as per site requirement and as directed
-ditto- all as per Item No -39 here in above but of size 3.5 core 35 Sqmm to 3.5 core 70 Sqmm
-ditto- all as per Item No -39 here in above but of size 3.5 core 95 Sqmm to 3.5 core 120 Sqmm
-ditto- all as per Item No -39 here in above but of size 3.5 core 150 Sqmm to 3.5 core 180 Sqmm
S& F in repalcement of MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA complete all as specified and directed by Engg-in-Charge.
-ditto- all as per Item No -43 here in above but of size Adjustable type, 160 Amps with breaking capacity 36 KA.
-ditto- all as per Item No -43 here in above but of size Adjustable type, 200 Amps with breaking capacity 36 KA.
-ditto- all as per Item No -43 here in above but of size Adjustable type, 250 Amps with breaking capacity 36 KA.
M&L Earthing complete with copper plate electrode 60×60cm ×3.15mm size & copper strip 20 x 3 mm brazed with copper plate buried in ground not less than 1.5 Mtrs deep with PCC chamber complete all as specified and as directed means of bolts, nuts, check nuts and washers of brass check nuts and washers of brass including necessary earth work, PCC chamber , CI cover with frame, funnel, mesh, Earth lead protection pipe, 7.5 Meter Earth Lead etc all as shown in electrical plate No 3 in SSR Part-I and connected to earth test point/LT Panel/Transformer including testing on completion all as directed by Engr in-Charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
TD8557.pdf
Tender Documents • 2.03 MB
BOQ_834961.xls
BOQ • 0.47 MB
Download all tender documents and submit your bid