Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 CrAccepted-AOC 245A 7A 1 JAYANTIPUR GOKUL AWAS YOJNA SULEM SARAI PRAYAGRAJ UTTAR PRADESH | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211011 | ₹2.0 Cr | L1 | Accepted-AOC BEING THE LOWEST BIDDER |
| 2 | L2₹2.1 Cr+₹11.6 L (5.81%)Rejected-Finance 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400708 | THANE | MAHARASHTRA | 400708 | ₹2.1 Cr+₹11.6 L (5.81%) | L2 | Rejected-Finance BEING OTHER THAN THE LOWEST BIDDER |
| 3 | L3₹2.6 Cr+₹56.9 L (28.5%)Rejected-Finance 21 PASCHIM VIHAR EXTENSION NEW DELHI 110 063 | NEW DELHI | WEST DELHI | DELHI | 110063 | ₹2.6 Cr+₹56.9 L (28.5%) | L3 | Rejected-Finance BEING OTHER THAN THE LOWEST BIDDER |
| 4 | L4₹2.6 Cr+₹61.7 L (30.9%)Rejected-Finance | ₹2.6 Cr+₹61.7 L (30.9%) | L4 | Rejected-Finance BEING OTHER THAN THE LOWEST BIDDER |
| 5 | L5₹2.8 Cr+₹76.2 L (38.2%)Rejected-Finance | ₹2.8 Cr+₹76.2 L (38.2%) | L5 | Rejected-Finance BEING OTHER THAN THE LOWEST BIDDER |
| Sl No | Description | Qty | Unit | DEORA ELECTRIC WORKS L4 | V S BUILDER L5 | MUKESH CONSTRUCTION CO L2 | M/s R. K. Bhambri L3 | R.K.ASSOCIATES L1 |
|---|---|---|---|---|---|---|---|---|
| 2.00BLANK | ||||||||
| 3.00BLANK | ||||||||
| 4.00BLANK | ||||||||
| 5.00BLANK | ||||||||
| 6.00BLANK | ||||||||
| 7.00BLANK | ||||||||
| 8.00BLANK | ||||||||
| 9.00SCH 'A' PART X (MISC B/R & E/M ITEMS) Note:- Excavation and earthwork to the extent required for execution of relevant item under this schedule unless otherwise specified shall be measured and paid under relevant items of Schedule 'A' Part-II. | ||||||||
| 9.00INTERNAL ELECTRIFICATION | ||||||||
| 9.01 | Supply and fix energy efficient 20 watt (4.0 feet) LED integrated batten type luminaires suitable for wall or ceiling mounting with built in LED Chip and integral LED driver 20 watt, Aluminium channel housing and polycarbonate diffuser of length 1200 mm (approx.),Color temperature 6500K or as directed, CRI between 80-85, Low THD, PF-0.90 (minimum), efficiency not less than 100 lumen/watt or total lumen output not less than 2000 lumen per 20 watt, operating range 200-270V, surge protection of 2 KV,over voltage protection and other safety tests as per IS 15885 Part-2/Part-3,estimated life span of 50000 hrs with all accessories, complete with fixing arrangement, fittings shall be internally prewired and conforming to LM 79 & LM 80 standard, making all connection using 1.5 sqmm copper conductor multistrand PVC insulated 3 core flexible cable from ceiling rose to fitting drawn through PVC flexible conduit complete fixed in position and connecting complete all as specified and directed.
Note:
(i) LED fitting shall be provided for 3 years warranty.
(ii) Location for Installation of LED fitting shall be as per approved drawing | 21 | Each | 1,500 ₹31,500 | 850 ₹17,850 | 900 ₹18,900 | 600 ₹12,600 | 290 ₹6,090 Lowest |
Tender Value
₹1.5 Cr
EMD Value
₹2.3 L
Closing Date
22 Oct 2025, 6:00 pmClosed
Chief Engineer(AF) Nagpur
HQ CE (AF) Nagpur Vayusena Nagar Nagpur-07
PROVISION OF STP AT MANAURI UNDER AGE I MANAURI
2025_MES_711418_1
AF_MAN_801246
Open Tender
Civil Works
Lump-sum
365 days
MANAURI
For MES Enlisted Contractors- Class B Category a (ii) For other Contractor meeting enlistment Criteria of MES for Class B Category a (ii)
6 documents required · 6 mandatory
₹1,000
AGE I Manauri
₹2.3 L
Yes
HQ CE (AF) Nagpur
30 Jan 2026
30 May 2025
29 Oct 2025
6 Oct 2025
22 Oct 2025
15 Oct 2025
30 May 2025 - 6 Jun 2025
9 Jun 2025
Amount
BLANK
BLANK
BLANK
BLANK
BLANK
BLANK
BLANK
SCH 'A' PART X (MISC B/R & E/M ITEMS) Note:- Excavation and earthwork to the extent required for execution of relevant item under this schedule unless otherwise specified shall be measured and paid under relevant items of Schedule 'A' Part-II.
INTERNAL ELECTRIFICATION
Supply and fix energy efficient 20 watt (4.0 feet) LED integrated batten type luminaires suitable for wall or ceiling mounting with built in LED Chip and integral LED driver 20 watt, Aluminium channel housing and polycarbonate diffuser of length 1200 mm (approx.),Color temperature 6500K or as directed, CRI between 80-85, Low THD, PF-0.90 (minimum), efficiency not less than 100 lumen/watt or total lumen output not less than 2000 lumen per 20 watt, operating range 200-270V, surge protection of 2 KV,over voltage protection and other safety tests as per IS 15885 Part-2/Part-3,estimated life span of 50000 hrs with all accessories, complete with fixing arrangement, fittings shall be internally prewired and conforming to LM 79 & LM 80 standard, making all connection using 1.5 sqmm copper conductor multistrand PVC insulated 3 core flexible cable from ceiling rose to fitting drawn through PVC flexible conduit complete fixed in position and connecting complete all as specified and directed. Note: (i) LED fitting shall be provided for 3 years warranty. (ii) Location for Installation of LED fitting shall be as per approved drawing
Supply and Fixing distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 8 way with appropriate Amps rated copper busbar, neutral bar, internal earth bar and cable ties for cable management,reversible door forIP 43 & IP 54, IK 09 impact resistance, single pole and neutral 250 Volts, flush to wall including chases cutting in wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.DB shall be designed with provision for MCB SPN as incomer & MCB SP as outgoing as per requirement. Cost of the DBs will be without MCBs complete all as specified and as directed Note - Rates are inclusive for flush (Concealed ) mounting of DB SPN .
Supply and Fix distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 4 way with appropriate Amps rated copper busbar, neutral bar,internal earth bar and cable ties for cable management,reversible door for for IP 43 & IP 54, IK 09 impact resistance, single pole and neutral 250 Voltss, flush to wall including chases cutting in wall for fixing DB and making good distributed wall surfaces to match with existing specification.DB shall be designed with provision for MCB SPN/TPN/FP as incomer & MCB SP as outgoing as per requirement. Cost of the DBs will be without MCBs copmplete all as specified and as directed. Note - Rates are inclusive for flush(Concealed ) mounting of DB SPN .
Supply and fixing 1400 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod/down rod as per height available at site , 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.0,Air delivery minimum 245 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin,nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm,suitable for 230 V, 50 Hz, single phase AC Supply etc , complete with fixing arrangement anchor tpe fastener hook including connection with 1.5 sqmm mutistrand copper conductor flexible wire from ceiling rose to fan drawn through PVC flexible conduit complete all as specified and directed.
Supply and fixing of Exhaust fan 300mm sweep, heavy duty motor with double ball bearing, metallic body , with bird guard to protect the fan in running condition, AC, single phase, 230Volts, including connection with 1.5 sqmm mutistrand copper conductor flexible wire from ceiling rose,complete with blades,frame and outside louvers with necessary fixing arrangment and making good to disturbed surface complete all as specified and directed .
Supply and fixing LED Street Light fitting 35 watt, for opearting voltage between 140V to 270V system luminious efficiency not less than 110 lumen / watt, PF-0.95 minimum, IP-66 protection, 5700 CCT(K),CRI between 80-85,confirming to LM79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012, for estimated life span of minimum 50000 hrs consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits SMPS based constant current supply with phase to phase protection,over voltage protection , surge protection and other safety tests as per IS 15885 Part-2/Sec13, Low THD, PMMA grade high quality transmittance lens, LED street optics LENS for uniform light distribution, weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in pressure die cast aluminium housing with SS screws with IP 65/66 protection, complete all as specified and as directed .
Material and labour for Earthing complete with GI earth electrode plate of size 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to GI wire 4mm dia as earth lead up to test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregates, 40mm thick precast RCC cover in 1:2:4 reinforced with expanded metal (weight not less than 4 kg/sqm), and frame of angle iron 25x25x6mm with lugs 02 nos with 6mm dia MS bar handle made to shape, excavation and earth work in any type of soil and including light grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI earth wire protection pipe 15mm bore up to main board complete as shown in electrical plate no 3 of MES schedule Part-I , connected to earthing testing point and testing on completion complete all as specified and directed . (For External Electric Supply - Qty 10 EachSet) Note: (i) The unit rate includes GI pipe up to 7.5m for protection of earth lead. For any additional length the same shall be adjusted through deviation order. (ii) The unit rate includes main earthing lead/strip from earth electrode to test point up to 7.5 meter (iii) In case measured value of earth resistance is recorded less than 1.0 ohms then the earthing shall be re done by the contractor without any extra cost to the department.
Supply & Fixing Bracket made out of GI light grade pipe of size 40 mm dia 1.5 mtr long bend to an angle of 120 degree with 02 Nos MS clamp 50mm x 50mm and 04 sets of nuts,bolts and washers painting with two coats of synthetic enamel paint over a red oxide primer complete all as specified and as directed .
Supply and fix 16 SWG CRCA sheet steel enclouser IP 43, powder coated, wall/column mounted with provision for support arrangement, earthing terminal, incoming and outgoing cable terminal etc with required hardware and fasteners with 3 pin plug and socket (two pole and earth ) with cap and chain and with one single pole MCB of capacity 20 Amps 240 volts rated for 10KA C curve type complete all as specified and as directed.
EXTERNAL ELECTRIC SUPPLY
Labour for cutting /boring to plinth protection/ hard standing / road etc in suitable depth to across the GI pipe size upto 80 MM dia of bore for drawn through XLPE under ground cable for giving mechanical protection to cable complete all as directed. Note - Quoted rate shall be included the cost of required material for repairing to disturbed surface all as per exisited.
Supply, installation, testing and commissioning of LT Feeder Pillar outdoor type confirming of IS 5039, CPRI approval, totally enclosed vermin proof suitably ventilated for 3 phase, 4 wire 415 Volts, 50Hz, AC supply, outer sheel shall be made out of 3.15mm thick CRCA sheet & MS angle section of suitable size for frame, factory fabricated, compartmentalized inner shell shall be made of out of 2.0 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front. Panel shall be provided with proper ventilation arrangement from both sides including ventilation fan etc.Protection of enclosure IP 56 with pre-treatment through 7 tank hot chemical process prior to powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable plate having provision for entry of armoured cable of adequate size. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided.The panel shall be provided with manufacturer name plate,heavy duty SS cable glands of adequate size for incoming and outgoing cables. EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60cm long using angle iron 40x40x6mm duly painted with anti corrosive paint, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, 4 x legs 40 cm grouted in PCC 1:2:4 and making good distrubed surface complete and comprising of the following:-(For Sewage Pump House)
(A) TPN Aluminium electrolytic grade bus bar of capacity 125 Amps for phases & 63 Amps for neutral and auxillary bus bar to support main busbar duly supported on SMC/DMC, busbar supports and insulated with colour coded heat shrinkable sleeve (ii) Digital multifunction meter (V,A,KW,KWH), 415 AC alongwith C.T's of suitable ratio (set of three), class 1.0, complete (iii) Indication lamps LED type (RYB) =01 set of three (iv) Internal wiring with suitable size of FRLS copper conductor cable. B. INCOMER (i) MCCB 63 Amp 4 pole confirming to IS:13947(Part-3) 1993, 16 KA, lcs =100% lcu, with thermal magnetic release, adjustable overload 80-100% of nominal current and adjustable short ckt 5 to 10 ln setting complete with phase seperator - 01 nos. (ii) Panel mounted on load change over switch without enclosure front opertaed 4 pole 63 amps, 415V -01 nos C. OUTGOING:- (i) MCCB 40 Amp 4 pole confirming to IS:13947(Part-3) 1993, 16 KA, lcs =100% lcu, with thermal magnetic release, adjustable overload 80-100% of nominal current and adjustable short ckt 5 to 10 ln setting complete with phase seperator - 01 nos (ii) Miniature circuit breaker (MCB) single pole and neutral of current carrying capacity 32 AMP,10 KA 'B' curve, 240 volts -02 nos (iii) Miniature circuit breaker (MCB) single pole and neutral of current carrying capacity 20 AMP,10 KA 'B' curve, 240 volts -02 nos
Earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6.3) mm thick buried directly into ground vertically to depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, surrounded on all sides by alternate layers of 150 mm thick charcoal and common salt, connected to galvanized earth lead strip of size 25 x 4 mm by means of lugs, bolts, nuts, washer, check nuts of galvanised iron or steel all as shown in Electrical plate No. 2, wire protected by dia 15 mm bore light grade GI Pipe laid in floor and fixed to wall with proper size of clamps and watering pipe of bore 20 mm dia GI light grade including wire mesh funnel, PCC, earth chamber pit with PCC 1:2:4 type B-1 using 20 mm grade stone aggreate including from work cement mortar including CI Pit cover with frame necessary excavation and earth work in any type of soil including testing on completion for desired result all as specified. (for LT panel) ( For External Water Supply Qty -04 Each Set ) Note: (i) The unit rate includes GI pipe up to 7.5m for protection of earth lead. For any additional length the same shall be adjusted through deviation order. (ii) The unit rate includes main earthing lead/strip from earth electrode to test point up to 7.5 meter (iii) In case measured value of earth resistance is recorded less than 1.0 ohms then the earthing shall be re done by the contractor without any extra cost to the department.
Supply and fix LED Street Light fitting 70 watt, for opearting voltage between 140V to 270V system luminious efficiency not less than 110 lumen / watt ortotal lumen output not less than 7700 lumen/ 70watt ,PF-0.95 minimum, IP66 protection, 5700 CCT(K),CRI between 80-85,confirming to LM79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012,for estimated life span of minimum 50000 hrs consisting of high / low voltage cut off, maintenance free isolated,Electronic driver circuits SMPS based constant current supply with phase to phase protection,over voltage protection , surge protection and other safety tests as per IS 15885 Part-2/Sec13, Low THD, PMMA grade high quality Transmittance lens, LED street optics LENS for uniform light distribution, weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in pressure die cast aluminium housing with SS screws with IP 65/66 protection, complete all as specified and as directed .
Supply and fixing Junction box of size 200mm x 140mm x 95mm outdoor type, weather proof, factory made out of PVC sheet 1.8mm thick with front side hinged opening having locking arrangement with nuts & bolts & arrangement for incoming and out going cable / wire complete comprising with the followings items as under:- (a) Bus bar with two aluminium strips, 63 Amps cap.(15x 4mm) mounted on epoxy insulators, drilled holes for connection duly colour coded , including PVC cable of suitable size from bus bar to MCB (b) MCB SPN 5 to 30 Amps, - 01 No (c) Clamp made out of 25mm x 3mm flat iron duly welded with nuts & bolts complete all as specified and directed.
Supply & fixing Bracket made out of GI light grade pipe of size 40 mm dia 1.5 mtr long bend to an angle of 120 degree with 02 Nos MS flat clamp 50mm x 50mm covering the circumference of pole including 04 sets of nuts,bolts and washers, painting to clamps with two coats of synthetic enamel aluminium paint over a coat of red oxide primer complete all as specified and as directed .
ETERNAL WATER SUPPLY
Material and labour for construction of brick masonry valve pit chamber including necessary excavation and earth work and MS sheet cover 3mm thick and angle iron 50x50x6mm frame incluidng locking arrangements with 50mm pad lock and duplicate keys, duly painting the steel surfaces in two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified of size 1050 x1050 x1050 mm (Internal dimension) complete all as specified and as directed .
Supply nand fixing rotational moulded polyethylene water storage tank of capacity 5000 ltrs (cylindrical vertical with closed top ) hoisted and fixed in position complete all as specified and as directed .
Supply, installation, testing and commissioning of LT Feeder Pillar indoor type confirming of IS 5039, CPRI approval, totally enclosed vermin proof suitably ventilated for 3 phase, 4 wire 415 Volts, 50Hz, AC supply, outer sheel shall be made out of 2.00mm thick CRCA sheet & MS angle section of suitable size for frame, factory fabricated, compartmentalized inner shell shall be made of out of 1.6 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front. Panel shall be provided with proper ventilation arrangement from both sides including ventilation fan etc.Protection of enclosure IP 42 with pre-treatment through 7 tank hot chemical process prior to powder coated powder coated with pre-treatment through 7 tank hot chemical process prior to powder coated with minimum 50-70 micron with pure polyester siemens grey structural RAL 7035 shade. The bottom of outer shell contains a detachable plate having provision for armoured cable entry with adequate size detachable glands.Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided.The panel shall be provided with manufacturer name plate,heavy duty SS cable glands of adequate size for incoming and outgoing cables.EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size
angle iron/flat iron frame work/support required with four legs 60cm long using angle iron 40x40x6mm duly painted with anti corrosive paint, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, 4 x legs 40 cm grouted in PCC 1:2:4 and making good distrubed surface.The panel shall be designed with arrangement for controlling of two motors complete and comprising of the following (Sludge Pump + Open well pump :- (A) (i) TPN Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic , non combustable, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and interconnected busbar.The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables.All control wires shall be with 2.5sqmm FRLS multi stranded copper conductor and shall be properly bunched , tied,ferruled for proper identification and crimped with adequate size of lugs (ii) Digital multifunction meter (V,A,KW,KWH), 415 AC alongwith C.T's of suitable ratio (set of three), class 1.0, complete for metering (iii) Indication lamps LED type (RYB) =01 set of three . (iv) MCB SP 6A 'C' series for control ckt protection = 02Nos. (B) INCOMER :- MCCB 40 Amp 4 pole, 16KA, lcs = 100% lcu, with fixed magnetic and adjustable thermal release, adjustable overload 80-100% and adjustable short ckt 5 to 10 ln setting complete with phase seperator confirming to IS/IEC 60947 Part 2 - 02 nos Note: (i) Contractor shall submit the following Test report i.e. IP Test Report and verification of short circuit withstand test report issued by CPRI in respect of LT Panel (ii) Contractor shall submit drawing for approval prior to place order.
Supply and Fix cast iron butter fly valve of following sizes, with both end flanged type 50mm bore in PN 2.0 rating, conforming to IS 13095 with nuts bolts and washers of suitable size and necessary rubber gaskets etc for the following sizes complete all as specified and directed .
Supply ,installation,testing and commissioning of monobloc pump set with copper rotor suitable for raw/turbid water application suitable for 3 phase 415 volts , capacity 700 LPM at 10mtr head confirming to IS 14220(1994) with stainless shaft , bronze bush and stamping lamination with high permeability steel for long life and increased efficiency,impeller cast iron.Insulation: B class Protection: IP 68The cap of motor in HP/KW shall be as per recommendation of the manufacturer.The cap of motor is 3HP/2.5KW or as per recommendation of the manufacturer.The motor shall be confirming to IS:9283(1994) with minimum 69% efficiency and Guaranteed Pump efficiency at design flow should be equal or greater than 65%. complete all as specified and as directed.
Supply and fix stainless steel bourdon type pressure gauge dial type 0 -14 Kg/cm2 range with a stainless steel body complete including all necessary GI pipe connection fittings / cutting / jointing all as specified and directed.
Material and labour for construction of valve chamber of size 750x 750 x 750 mm deep dimensions (Over all internal dimension) with PCC foundation, random rubble uncoarsed stone masonry walls, Plastering, PCC Coping, white washing, mild steel chamber cover, painting to chamber cover including Excavation and earth work in any type of soil complete all as specified below :- Valve chamber shall be provided with the following specifications:- (i) Cement concrete for foundation (1:4:8) type D2 using 40mm graded stone aggregate 150 mm thick extended up to 150 mm beyond the outer face of block masonry. (ii) Walls of valve chamber 230 mm thick with precast cement concrete (1:5:8) (using 20mm graded stone aggregate) using brick masonary setting in CM 1:6 complete. (iii) Internal and exposed surfaces of valve chamber both concrete and brick masonry surface shall be plastered with CM (1:4), 15 mm thick finished even and smooth. (iv) 50 mm thick coping in PCC 1:3:6 type C1 over brick masonry wall. (v) Entire plastered surfaces shall be treated with 3 coat of white wash. (vi) Chamber cover shall be of 6 mm thick MS sheet with 30 x 30 x 5 mm size angle iron frame with hold fast and locking arrangement. Steel surface shall be painted with two coats of synthetic paint of first quality over one coat of red oxide primer complete all as specified and as directed .
SEWAGE DISPOSAL B/R & E/M
Supply, Installation, comissioning and testing of package type sewage treatment plant based on principle of aerobic attached growth non clogging randomly moving bed bioreactor (MBBR) having capacity 150 Cum/ Job day including all civil mechanical/ electromechanical/ electrical and other miscellaneous works as specified hereinwith and particular specifications so as to achieve the parameters mentioned in the tender documents from any of reputed OEMs. DESIGN DATA A. EFFLUENT TYPE: Description Parameters Type of Waste : Domestic Waste Total Waste : 150 KLD Operation Hour : 24 hr Stage of Treatment : 03 (Primary, Secondary, Tertiary) Use of treated water : Gardening B . INLET EFFLUENT PARAMETERS: Description Parameters PH : 6.5-8.5 Oil & Grease : 200-350 mg/l TSS : 30-40 mg/l BOD : 200-450mg/l COD : 400-800 mg/l FC MPN : very high
The accumulating solids known, as "Sludge" shall flow at periodic intervals through a desludging valve from the clarifier tank bottom to the centrifuge. The Primary and secondary tube settler/ clarifier as per design requirement shall be provided with overflow weir to collect the treated effluent and a scum baffle shall keep any floating matter from passing out in the final treated water for the fixed media system. The tube settler to be designed in size on the basis of rate velocity of 1.5-2 M/Hr and 4-5 M/Hr in clarifier.Treated water from secondary clarifier shall over flow into baffled chlorine contact tank where hypochlorite solution shall be added to disinfect the treated water from sludge drying bed, waste water will be sent to existing raw sewage well through Gl pipe 100mm/Channel. BLOWERS AND AERATION SYSTEM i) The package type treatment plant shall be provided with rotary positive displacement blowers with a common base and a central electric control panel, belt drive system, drip proof induction type electric motors, necessary valves including a pressure relief valve and intake and discharge silencing. Each blower motor unit shall be housed in an enclosure. All piping and related accessories necessary to connect the blowers to the plant air header shall be provided by the plant manufacturer. ii) All air piping from the blower motor unit to the air header shall be approved GI pipe. The dia of Gl pipe from pump to header shall be 80mm heavy grade. The further air distribution pipe shall be stainless steel 304 grade, 40 mm dia. The spacing between coarse/ fine bubble diffuser shall be 50mm c/c. Length of the pipe shall be calculated accordingly. iii) The air piping form the blowers shall be connected to the diffusers placed at the bottom of the Bio Reactors / Sump Pit if required / Equalization Tank / Sludge holding Tank / Flushing water holding tank.
ELECTRICAL CONTROLS i) The control system shall include circuit breakers, motor, starters and timers all housed in a cables from DB to motors shall be PVC insulated armored cables to be laid in trays. All wiring shall be sized according to the National Electric Code Standards. No splice shall be permitted in the service wires. It shall also be the responsibility of the contractor to furnish and install all required exterior disconnects, switching mechanisms, alarm or control conduit and wiring. The specifications of the control panel / DB would be as per tender specifications or manufacturer's design subject to approval. The branch circuit shall be short circuit protected by thermal magnetic air circuit breakers. All control circuits shall be protected by a single-phase thermal magnetic air circuit breaker. A magnetic across the line starter with overload heaters in each phase and a common trip contact set shall be provided for each blower motor to give positive protection against single phasing. ii) Motor insulation shall be class 'B' insulation and the design shall be such that the maximum permissible temperature for the insulation is not exceeding when the motor operates at service factor load in 45° C ambient on full load condition. All motors shall have anti-friction; ball bearings sized an average life of at least as per Motors Manufactures Ltd. under normal V-BELT loading conditions. The control equipment starters, circuit breakers, and switches shall be installed in an IP-42
E. FLOW DIAGRAM Incoming Sewage Collection Pit ↓ Stilling chamber ↓ Bar Screen Chamber ↓ Oil Grease Chamber ↓ Equalization Tank ↓ MBBR Reactor ↓ Settling Tank ↓ Clarified Water Tank/Chlorine contact tank ↓ Multi Grade Filter ↓ Activated Carbon Filter ↓ Treated water tank ↓ Pumping for arboriculture
2 (A) ELECTRO-MECHANICAL EQUIPMENTS Package type Sewage Treatment Plant (STP) based on attached growth concept (with air diffuser membrane system) MBBR with 2 reactors in series with sewage handling capacity of 150 M3/ day. The raw sewage comprises of effluent from entire residential and official campus for which a common STP has to be designed. The stilling tank with bar screen shall be a part of the STP. The package type STP shall be designed as water retaining structures in RCC with MS steel top structure and M.S. epoxy coated, non-skid type, removable manholes covers including piping, valves, necessary chemical dosing as required by the manufacturer's design. All the equipments, pipings, pumps, air blowers and electricals are to be housed in a plant room underground/over ground including MS puddle flange/insert need to be hot dipped galvanized, inlet, outlet, overflow, vents, MS covers, drain channel with MS gratings etc. The package type STP shall consist of following units but not limited to these units as may be required by the manufacturer's design: (a) Stilling chamber to reduce the velocity after being received from pump (b) Bar Screen cum Grit chamber for the incoming sewerage from building SS frame, manually cleaned SS bar screen, bar screen having provision for lifting, etc. (c) Oil & Grease Trap for kitchen waste to remove O&G with baffles need to be provided including MS manhole cover for total effluent of 150 KLD. (d) Main Equalization Tank for collection of total effluent including effluent waste, housing the pumps. Provision for aeration shall be kept to avoid any smell problems. (e) Moving bed bioreactors with PVC media including air diffusers at the bottom, sewage distribution header & baffle wall towards the outlet of the reactor. (f) Settling Tank suitable for150 cum/Day fitted with PVC plates or tube deck media in series at 60 deg. angle increasing the settling area and removal of the particles effectively in a smaller plan area. (g) Chlorine contact cum filter feed tank for chlorine mixing and desired minimum volume. (h) PVC hypochlorite solution tank ( cap. 100 ltrs.) with dosing pump of suitable capacity adjustable metering type.
(j) Suitable size of treated water( flushing/irrigation), soft water and sludge holding trank. (k) Air diffusion system with 2 nos. twin-type rotatory air blowers. (1 working + 1 standby) of suitable package type STP capacity for 150 M3/ day and necessary piping including air dispersion grid as given in specification for MBBR Reactors and Equalization Tank. Notes: i) The rate for foundation/platform required for installation of sewage treatment plant tank are deemed to be included in the quoted rates by the bidder. The daimension of the foundation are as per manufacturer /Supplier of STP tank. ii) Nothing extra on account of this will be paid by the department. (l) BAR SCREENS Providing and fixing 2 Nos SS Bar Screens in the Screen Chamber of the Sewage Treatment Plant - 01 Set Size: 500 mm x 600mm (Approx.) or as per drawing Mesh Size: 8 mm & 10mm (1 (m) PUDDLE FLANGES & INSERTS Supplying, Installation Testing and Fixing of MS Puddle Flange/ Inserts plates need to be hot dipped galvanized shall be in the scope of the sewerage treatment contractor - 01 Set (n) SEWAGE TRANSFER PUMPS (COLLECTION PIT) Providing and fixing non-clog, open impeller type fully submersible pumps in the existing Collection Pit. The pump shall be complete in Cl construction with cutter arrangement including lifting arrangement for the pumps including piping, valves on the discharge of pumps, level controllers, probes, cable, etc. including connection to STP (1) Submersible pumps - 20.0 m3/hr @ 25 mtrs head - 02 Nos or as required complete with star delta starter, overload protection, single phase preventor with each pump set
(o) SEWAGE TRANSFER PUMPS (EQUALIZATION TANK) Providing and fixing non-clog, open impeller type fully submersible pumps in the Equalization Tank. The pump shall be complete in Cl construction with cutter arrangement including lifting arrangement for the pumps including piping, valves on the discharge of pumps, level controllers, probes, cable, etc. including connection to STP (i) Submersible pumps 7.5 m3/hr @ 10 - 12 mtrs head - 02 Nos complete with star delta starter, overload protection, single phase preventor with each pump set. (p) AIR DISPERSION SYSTEM (i) Twin Rotatory Air Blower, Head -0.5Kg/cm2, Capacity as per requirement (Min.-150.0 cum/hr) with Motor driven through "V" belt or directly coupled through flexible coupling to a TEFC motor of suitable HP Suitable for 415 + 10% volts, 3 phase, 50 cycles A/C - 02 Nos complete with star delta starter, overload protection, single phase preventor with each pump set. (ii) Provision of Coarse Bubble Diffuser non clog type air dispersion system capable of handling desired cfm of air. Air dispersion system shall be provided for raw sewage equalization tank & sludge holding tank - 24 Nos (iii) Provision of Fine Bubble Diffuser non clog type air dispersion system capable of handling desired cfm of air. Air dispersion system shall be provided for raw sewage equalization tank & sludge holding tank - 40 Nos (q) FILTER FEED PUMPS Providing and fixing Horizontal centrifugal pumping set for filter feed pumps and discharging into the treated water tank. The pumps shall have Cl casing, Bronze impeller - EN 8 shaft with key with mechanical rotary shaft seal connected by a flexible tier type coupling to a TEFC induction motor mounted on a common channel base-plate with coupling guard, 150 mm dia pressure gauge, GM isolation cock, suitable vibration eliminator, pads of approved design. Motor to be suitable for 400/440 V, 3 Phase, 50 cycles AC power supply. Including all necessary piping. valves and other accessories from STP to filtration units and treated water tanks. Capacity: 7.5 m3/h @ 20-25 mtr head - 02 Nos
(r) Sludge Transfer Pumps Suitable For MBBR System Providing and fixing horizontal, centrifugal Sludge lifting pump to transfer sludge from SST to centrifuge. The pumps shall have Cl casing, impeller - shaft with mechanical rotary seal connected by a flexible tier type coupling to a TEFC induction motor mounted on a com channel base-plate with coupling guard, 150 mm dia pressure gauge, GM isolation cock, su vibration eliminator, pads of approved design. Motor to be suitable for 400/440 V, 3 Phas cycles AC power supply. Including all necessary piping, valves and other accessories incl piping from pump to outside of suitable size 50 mtr. (approx.) length of suitable size to unloa sludge into a tanker as instructed by site-in-charge complete in all respect. (i) Capacity: 5.0 m3/hr @20 m head for MBBR System - 02 Nos (ii) Providing, fixing, testing and commissioning of manual top discharge bucket type centrifuge of capacity 3.0 m3/hrs having dia 30" with MSRL/MSFRP body and MSRL basket - 01 job (s) Multi Grade Sand filter: (Suitable for 150.0m3/Day) Providing, fixing, testing & commissioning of vertical Pressure Sand Filter fabricated from FRP/MSEP sheet with rubber lining as per manufacturer's specifications with UPVC frontal piping including valves to provide service, backwash and rinsing operations. Complete with initial charge of filter media. Including Anthracite - 01 Set (t) Activated Carbon Filter: (Suitable for 150.0 m3/Day) Providing and fixing vertical FRP/MSEP make Activated carbon Filter with rubber lining of (lodine value not less than 1000) as filter media. The shell shall be complete with initial charge of filter media UPVC frontal piping, complete including valve for service, rinse & backwash alongwith other accessories - 01 Set (u) All interconnecting pipelines, fittings and isolation control valves for making the system complete.-01 No. (v) Hypo Dosing Pumps having capacity of 0-6 LPH Metering Type with dosing Tanks of 100 Lits-02 Nos (w) Supply, installation, testing & commissioning of Random Media for attached growth process (MBBR Technology) MOC = PVC, Specific Gravity = 0.93 -0.95, Surface Area = 500 sq.mtr/cum.mtr - 30 Cum (x) Supply, installation, testing and commissioning of PVC tube deck settling media to be installed in secondary settling tank - 10.50 Cum (y) Pump for treated water 02 Nos. specifications as per PS
Supply ,installation,testing and commissioning of self priming, VFD control non clog submersible pump with radially split casing over hung non clog impeller which allows passage of solid up to 20mm suitable for drain/sewage water application suitable for 3 phase 415 volts , capacity 600 LPM at 25mtr head,double mechnical seal ,high tensile steel shaft ,cutter fan arrangement .Drive motor is dry type submersible Insulation: F class Protection: IP 68 as per IS 2147 The cap of motor in HP/KW shall be as per recommendation of the manufacturer.The motor shall be confirming to IS:9283(1994) with minimum IE2 efficiency and Guaranteed Pump efficiency at design flow should be equal or greater than 65%. complete all as specified and as directed by Engr-in-charge complete all as specified and as directed.
INTERNAL WATER SUPPLY
Supply and fix angle valve of cast copper alloy chromium plated fancy type screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed for 15mm bore complete all as specified and directed.
Supply and fix DWCPE (SN8) 300 mm dia with socket and spigot laid in trenches on concrete bed to required slope joined and tested includes all items and activities to executes and make sewer line functional complete all as specified and directed.
Supply and fix DWCPE (SN8) 200 mm dia with socket and spigot laid in trenches on concrete bed to required slope joined and tested includes all items and activities to executes and make sewer line functional complete all as specified and directed.
Supply and fix DWCPE (SN8) 150 mm dia with socket and spigot laid in trenches on concrete bed to required slope joined and tested includes all items and activities to executes and make sewer line functional complete all as specified and directed.
Total amount of Schedule 'A' Part X carried over to General Summary
SCH 'A' PART XI (MANNING AND OPERATION OF STP)
Manning, operation and comprehensive maintanance of newly installed sewage treatment plant as directed in all calender days (11 months) including Sunday/holiday ( gazzeted/restricted) by deployed persons by employing one FGM cum operator (skilled) / reliver for 8 hours of shift ( shift time shall be 0900 hrs to 1700 hrs) complete all as specified and as directed.
Manning, operation and comprehensive maintanance of newly installed sewage treatment plant as directed in all calender days (11 months) including Sunday/holiday ( gazzeted/restricted) by deployed persons by employing one FGM cum operator (skilled) / reliver for 8 hours of shift ( shift time shall be 0900 hrs to 1700 hrs)complete all as specified and as directed.
Manning, operation and comprehensive maintanance of newly installed sewage treatment plant as directed in all calender days (02 months) including Sunday/holiday ( gazzeted/restricted) by deployed persons by employing one FGM cum operator (skilled)/ reliver for 8 hours of shift ( shift time shall be 0900 hrs to 1700 hrs) complete all as specified and as directed. Note for item no. 9.29 ,9.30 and 9.31 : Rate quoted by the contractor shall deemed to be included for : (i) All consumable/laboratory testing material and chemical dozing materials/ spares/ media as recommended by OEM for operating newly constructed STP. (ii) Testing of sewage water before treatment and after treatment after collecting sample from sewage treatment plant for the parameters all as directed. (iii) Treated water test report will be submitted by contractor 1st week of every month to department.
Total amount of Schedule 'A' Part XI carried over to General Summary
GENERAL SUMMARY
Lumpsum price worked out by the contractor for “BUILDINGS & STRUCTURES” as listed in Schedule ‘A' Part I representing above / below the lumpsum price as inserted by MES for Schedule ‘A’ Part I on Srl Page No. 26(R)
Lumpsum price worked out by the contractor for “SITE CLEARANCE, EXCAVATION AND EARTH WORK (FOR SCHEDULES OTHER THAN SCHEDULE 'A' PART-I)” as listed in Schedule ‘A' Part II representing above / below the lumpsum price as inserted by MES for Schedule ‘A’ Part II on Srl Page No. 27(R)
Lumpsum price worked out by the contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A' Part III representing above / below the lumpsum price as inserted by MES for Schedule ‘A’ Part III on Srl Page No. 32 (R)
Lumpsum price worked out by the contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A' Part IV representing above / below the lumpsum price as inserted by MES for Schedule ‘A’ Part IV on Srl Page No. 33 (R)
Lumpsum price worked out by the contractor for “ROAD/ PATH/ HARDSTANDING/CULVERT " as listed in Schedule ‘A' Part V representing above / below the lumpsum price as inserted by MES for Schedule ‘A’ Part V on Srl Page No. 37 (R)
Lumpsum price worked out by the contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A' Part VI representing above / below the lumpsum price as inserted by MES for Schedule ‘A’ Part VI on Srl Page No. 39 (R )
Lumpsum price worked out by the contractor for “EXTERNAL ELECTRIC SUPPLY” as listed in Schedule ‘A' Part VII above/below the lumpsum price as inserted by MES for Schedule ‘A’ Part VII on Srl Page No. 41(R)
Lumpsum price worked out by the contractor for “SEWAGE DISPOSAL B/R AND E/M ITEMS” as listed in Schedule ‘A' Part VIII representing above / below the lumpsum price as inserted by MES for Schedule ‘A’ Part VIII on Srl Page No. 42 (A)
Lumpsum price worked out by the contractor for “CLEAR WATER TANK (CAPACITY 15KL) ” as listed in Schedule ‘A' Part IX representing above / below the lumpsum price as inserted by MES for Schedule ‘A’ Part IX on Srl Page No. 42 (C)
Total amount of SCHEDULE 'A' PART X (MISC B/R & E/M ITEMS) brought forwarded from Serial Page No. 66 (R )
Total amount of SCHEDULE 'A' PART XI (MANNING AND OPERATION) brought forwarded from Serial Page No. 67 (R )
MUKESH CONSTRUCTION CO (BID ID -3462646)
M/s R. K. Bhambri (BID ID -3462772)
DEORA ELECTRIC WORKS (BID ID -3459414)
V S BUILDER (BID ID -3460588)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 3.81 MB
TENDERDOCUEXCLUNITBOQ.pdf
Tender Documents • 5.43 MB
ALLDRAWINGS.pdf
Additional Documents • 17.99 MB
BOQ_796691.xls
BOQ • 0.35 MB
801246CORRIGENDUM09.pdf
PDF • 0.31 MB
801246CORRIGENDUM08.pdf
PDF • 12.99 MB
801246CORRIGENDUM08.pdf
PDF • 12.99 MB
801246CORRIGENDUM07.pdf
PDF • 0.27 MB
801246CORRIGENDUM06.pdf
PDF • 0.26 MB
801246CORRIGENDUM05.pdf
PDF • 0.27 MB
801246CORRIGENDUM04.pdf
PDF • 0.26 MB
801246CORRIGENDUM03.pdf
PDF • 0.28 MB
801246CORRIGENDUM02.pdf
PDF • 0.24 MB
801246CORRIGENDUM01.pdf
PDF • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .