Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.3 LAccepted-AOC | ₹46.3 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹46.3 LRejected-Finance NUTANCHATI BANKURA 722101 | BANKURA | BANKURA | WEST BENGAL | 722101 | ₹46.3 L | L2 | Rejected-Finance Rate quoted above Lowest bidder |
| 3 | L3₹46.3 LRejected-Finance VILL SHIBCHANDRAPUR PO KASHIPUR PS REJINAGAR DIST MURSHIDABAD | MURSHIDABAD | WEST BENGAL | 700023 | ₹46.3 L | L3 | Rejected-Finance Rate quoted above Lowest bidder |
| 4 | L4₹46.8 LRejected-Finance AT BENJTABANI P O BAIDYANATHPUR DIST BANKURA PIN 722140 | BANKURA | WEST BENGAL | 722140 | ₹46.8 L | L4 | Rejected-Finance Rate quoted above Lowest bidder |
Tender Value
₹46.3 L
EMD Value
₹92,690
Closing Date
18 Feb 2026, 11:00 amClosed
Executive Engineer (AM)
OFFICE OF THE EXECUTIVE ENGINEER (AGRI - MECHANICAL) BANKURA (AGRI - MECHANICAL) DIVISION, ADMINISTRATIVE BUILDING PRANABANANDA SARANI, P.O. KENDUADIHI, DIST. BANKURA
Installation of Garerhdanga Electrified Handed Over Midi RLI Scheme , Block-Patrasayer, GP-Belut Rasulpur, Mouza-Belut, JL No.-59, Plot-457, Under Bishnupur (A-M) Sub-Division Under Bankura(A-M) Division Under Core Sector Programme 2025-26
2026_WRDD_996185_1
WBWRIDDEEAM/BANeNIT44/CS/25-26
Open Tender
Project Work
120 days
EE AM BANKURA AM DIV
Please refer Tender documents.
4 documents required · 4 mandatory
₹92,690
27 Feb 2026
3 Feb 2026
20 Feb 2026
3 Feb 2026
18 Feb 2026
3 Feb 2026
Campaigning in the command area of Midi RLI Sub-project by community workers for mass awareness , capacity building to achieve sustainability of Sub-projects. Cost include wage payment to community workers, transportaton, leaflet etc.
Meeting Cost for WUA formation, cost including Refreshment, training materials, transport local conveyance, wage payment to community worker, remuneration to resource person and incidental charges
Registration Cost for WUA under suitable act ( Society ) deed writing including registration charge, conveyance cost & opening of Bank A/C etc.
Livelyhood plan / Micro plan formulation cost for minor irrigation scheme, cost including refreshment, training materials, transport local conveyance, wage payment to community worker, remuneration to resource person and incidental charge ( rate on meeting )
Meeting and onsite demonstration for operation & maintenance of one Midi RLI tubewell, water manangement and mode of collection of water tax, building of corpus fund etc
IEC Materials ( Leaflet, poster, notebook )= 8 meetings, for SL - 2 and SL - 4
Documentation Cost for activities of WUA Scheme - by still photography, report booklet etc in both hard and soft copy.
Impact study & monitoring of scheme by site visit of 2 Community workers during 3 years' period
SUPPLY OF PVC PIPES & ACCESSORIES Rigid P.V.C. pipes with one loose coupler for every 6.0 mtr. Length and solvent cement accordingly to technical specification as per I.S.No. 4985/2000 with latest amendments and duly I.S.I. certification marked & CIPET tested. 200 mm.dia Class-I (0.25 MPA) with Coupler
140 mm.dia Class-I (0.25 MPA) with Coupler
140 mm.dia Class-II (0.40 MPA) with Coupler
Rigid P.V.C. Accessories of Class-II (0.4 MPA) according to Technical specification as per relevant IS Code with latest amendment & duly I.S.I. certification marked & CIPET tested. 200 mm.dia F.T.P. with Metallic flange
160 mm.dia F.T.P. with Metallic flange
200 mm.dia 60̊ Bend
200 mm.dia 90̊ Bend
140 mm.dia 600 Bend
140 mm.dia 900 Bend
200 x 140 mm.dia Reducer
160 x 140 mm.dia Reducer
200 mm.dia Equal Tee
140 mm.dia Equal Tee
200 mm.dia End Cap, class-III
140 mm.dia End Cap
200 mm.dia Extra Coupler
160 mm dia Extra Coupler
140 mm.dia Extra Coupler
Solvent cement conforming to I.S. No. 14128/94 with latest amendments, Medium Bodies.
100 mm.dia Flexible PVC Hose for Suction & Delivery line with ISI certification marked & CIPET tested.
Rubber Insertion, duly, reinforced 5 mm.thick 2 plies as per I.S.No.-6392 with latest amendments.200 mm.dia (Table-11)
200 mm.dia (Table-5)
100 mm.dia (Table-17)
150 mm.dia (Table-17)
80 mm.dia (Table-17)
150 mm.dia (Table-5)
MS ACESSORIES:-150 mm.dia C.I Sluice Valve (ISI Marked IS-14846)
100 mm.dia C.I Sluice Valve (ISI Marked IS-14846)
100 mm.dia GI ERW Pipe with Flange as per IS 1239 (Part-I) 2004 & 6392/1971, Table 7 specification
150 mm.dia GI ERW Pipe with Flange as per IS 1239 (Part-I) 2004 & 6392/1971, Table 7 specification
150 mm.dia Alfa Alfa Valve (Nipple Type as per IS 210)
150 mm.dia 900 G.I Bend(Both end flanged ISI Marked IS 1239)
100 mm.dia 900 G.I Bend (with Priming)(Both end flanged ISI Marked IS 1239)
100 mm.dia Foot Valve Lather Washer
100 mm.dia Swing type Foot Valve flanged end
100 mm.dia MS hose clamp with long nut & bolt
100 mm.dia MS Tail Piece One end Flanged other end grooved.
100 mm.dia MS Tail Piece both end grooved.
GI Set for quadruped (For midi RLI Scheme) All Material ISI Marked
Nuts & Bolts :- 20 mm x 80 mm
20 mm x 100 mm
16 mm x 80 mm
16 mm x 65 mm
16 mm x 50 mm
Foundation Bolt :- For Distrubution Chamber (20 mm.dia x 375 mm.long)
For Motor driven Pump Sets (8 Nos.)
Compresed Asbestos fibre jointing for Quadruped Set (for raised surface of Flange as per IS-6392/71) 500 mm.dia (Table-5)
(ELECTRICAL ITEMS ) Supply of Electromotor Pumping set with a suitable centrifugal water pump having capacity 100cub-meter/hr. discharge at 24m.head (section delivety 100mm x 100mm.dia),15 HP.Motor shall be designed for 415Volt.(+-6%)3 phase 50 CPS.AC supply 1450 RPM.The motor shall be TEFC as per IS 325.The pump shall be horizontal single stage split casting as per IS 6595/IS 12615 coupled with motor and shall be according designed.
Supply of 100 Amp Main switch complete for 15 HP Motors (switch fuse unit TPN ISI Marks IS-60947)
Supply of 32 Amp Main switch complete for 15 HP Motors (switch fuse unit TPN ISI Marks IS-60947)
Supply of 16 Amp Main switch complete for 15 HP Motors (switch fuse unit TPN ISI Marks IS-60947)
Supply of wooden pannel board of size1.5 m X 1 m X 0.025 m with 6 Nos. M.S. clamp for Pump House wall mounting
3 Phase Electro Magnetic Star Delta starter For 15 H.P Motor (Motor Controller IS -60947) (BCH make)
Supply of Bus bar for 100 Amp
Supply of Mini water pump (1HP,Head Range 3-32 Mtr., Discharge 3100-500LPH,Voltage-220 volt )with all accessories like suction(30 mtr),delivery pipe(30mtr),footvalve,adopter,nipple, Wooden frame for holding the set etc all complete
Tools kit comprising Slide wrench set 12" long, Ring wrench set, Side spanner set, Screw Driver 1' long, Hammer 500 Gram, Electrical Tester, Combind Pliers, Funnel 8" etc
PUMP HOUSE Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone), including removing, spreading or stacking the spoils, within a lead of 75 m as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1500 mm. (considering 50 mm clearence)
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidated the same by through saturation with water ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary Cement concrete (Mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement , if any, in ground floor as per relevant IS codes.(a) Pakur variety
Ordinary Cement concrete (Mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement , if any, in ground floor as per relevant IS codes.(a) Pakur variety
Hire and labour charges for shuttering with centering and necessary staging upto 4 metre using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). 25 mm. to 30 mm. thick wooden shuttering. For PUMP HOUSE
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. For works in foundation, basement and upto roof of ground floor / upto 4m. Tor steel/Mild steel (SAIL/ TATA/RINL)
Brick work in cement mortar (1 : 6) with first class kiln burnt bricks including racking out joints, scaffolding and other incidental works etc. complete. a) In foundation & plinth.
b) In superstructure ground floor
Plaster (to wall, floor, ceiling etc.) with (1:6) sand and cement mortar including rounding off or chamfering corners, as directedand racking out joints or roughening of concrete surface including throating. Nosing and drip course as necessary at ground floor. (a) 15 mm thick (1:6) proportion.
b) 20 mm thick with 1:6 cement mortar.
c) 10 mm thick with 1:4 cement mortar.
25 mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface). [Note: - Waterproofing as per item 9, polymer based paint as per item 8 (a) of subhead C of Section (C).
Neat cement punning about 1.5 mm. thick in wall dado, floor, drain, door and window sill etc. complete.
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 Kg/sq. Mtr. and up to 16 Kg/sq. mtr.
Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials.
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete A) UPVC Pipes:(i) 75 mm. Dia
B) UPVC Fittings:a) Plain Tee (i) 75 mm. Dia
C) Bend 87.5 degree (i) 75 mm. Dia
Earth work in filling in foundation trenches or plinth with good earth in layer not exceeding 150 mm. Including watering and ramming etc. layer by layer complete with earth obtained from excavation of foundation. (Payment to be made on the basis of measurement of finished quantity of work)
Priming one coat on timber, plastered surface with synthetic enamel/oil boud primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary. Two coats (super gloss hi- gloss except white) (b) On steel surface (Normal gloss).Two coats (with any shade except white).
White washing including cleaning and smoothening surface thoroughly (5 parts of stone lime and 1 part of shell lime should be used in finishing coat) all floor b) Three coats
Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification. ii) b) Two coats
Supplying 6 levers 'Godrej' Crystal Satine Mortice Lock with keys including fitting & fixing complete.
Carriage 4% on (SL -66-90) except Item No-66 & 85,90
WATER TRANSMISSION ARRANGEMENT Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone), including removing, spreading or stacking the spoils, within a lead of 75 m as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1500 mm..
Earthwork in excavation of field trenches as per designed section & alignment for laying of pipe lines(PVC,RCC,ACP etc.) upto a depth of 1500 mm in all sorts of soil including removing, spreading or stacking extra earth as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom as required complete.
Laying of PVC pipes of different diameters within field trenches in curve/ straight line including using UPVC fittings, Viz. Horizontal and Vertical Bends, riser pipes, Tee Reducer etc.and making leak proof joints with couplers after roghening the surface with wire brush and emery paper and applying solvent cement (The rate is inclusive of transport of pipesfittigs and solvent cement to be supplied by deptt.) all complete asper direction of Engineer-In- charge. i)200 mm. dia
ii)140 mm. dia
Earth work in filling in trenches after laying pipe lines (PVC,RCC,ACP etc.) with good earth obtained from excavation of field trences in layer not exceeding 225 mm , including watering & ramming etc. layer by layer complete. (payment will be made on the basis of measurement of finished quantity of work)
Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand.
Filling in foundation or plinth by fine sand in layers not exceeding 15 cm. As directed and consolidating the same by through saturation with water and ramming complete, including the cost of supply of sand.
Ordinary Cement concrete (1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering, reinforcement, if any, in ground floor as per relevant IS code. a) Pakur Variety (Stack yard to site distance= 40 KM)
Ordinary Cement Concrete (mix 1: 1.5 :3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS Codes. (Stack yard to site distance= 40 KM)
Hire and labour charges for shuttering with centering and necessary staging upto 4 metre using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). Above 25 mm. to 30 mm. thick wooden shuttering as per decision & direction of Engineer-In-Charge.
Reinforcement for reinforced concrete work in all sorts of structure including distribution bars, stirrups, binders etc. including supply of rods, initial straightening of bend bars excluding coil bars and removal of loose rust (if necessary) cutting to requisite length, hooking, bending to correct shape, placing in proper position and binding with 1.626 mm (16 SWG) black annealed wire at every inter section complete as per drawing and direction including cost of wire upto 1st floor level. ( For Tor steel).
Brick work in cement mortar (1 : 6) with first class kiln burnt bricks including racking out joints, scaffolding and other incidental works etc. complete in foundation and plinth.
12.5 cm. thick 1st class brickwork in cement mortar (1 : 4) in ground floor including, scaffolding, racking out joints etc. complete.
15 mm thick plaster (to wall, floor, ceiling etc.) with (1:6) sand and cement mortar including rounding off or chamfering corners, as directedand racking out joints or roughening of concrete surface including throating. Nosing and drip course as necessary at ground floor 15 mm thick (1:6) proportion.
Neat cement punning about 1.5 mm. thick in wall dado, floor, drain, door and window sill etc. complete.
Labour charges for fitting and fixing and laying , where necessary of fowlling M.S/G.I. /E.R.W pipes and accessories (to be supplied deparmentally) including transportation of the same cutting, threading, jointing & making leak proof threaded / flanged joints at site, by using scoket/ rubber insertion, nuts and bolts etc., maintaing the proper alignment and level / all complete / as per direction of E-I-C. 1a) 150 mm dia E.R.W Pipe.
Labour charges for fitting and fixing and laying , where necessary of fowlling M.S/G.I. /E.R.W pipes and accessories (to be supplied deparmentally) including transportation of the same cutting, threading, jointing & making leak proof threaded / flanged joints at site, by using scoket/ rubber insertion, nuts and bolts etc., maintaing the proper alignment and level / all complete / as per direction of E-I-C. 1b) 100 mm dia E.R.W Pipe.
fitting and fixing of M.S/G.I. /GI ccessories and special in pipe line accessories & special be supplied deparmentally) including transportation of the same cutting, threading, jointing & making leak proof threaded / flanged joints at site, by using scoket/ rubber insertion, nuts and bolts etc., havee zink (zink oxide) all complete / as per direction of E-I-C. 1a) 150 mm dia sluice valve
1a) 100 mm dia sluice valve
Erection, fitting, fixing of set of M S Quadruped inlet and outlet pipe fittings for 1st chamber and 2nd chamber of Midi RLI Scheme. (Rate inclusive of transportation from departmental store to work site)
Priming one coat on timber, plastered surface with synthetic enamel/oil boud primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary. Two coats (super gloss hi- gloss except white) (b) On ste
Labour charges for fitting, fixing 150 mm.dia Alfa Alfa Valve with 140 mm.dia PVC pipe with the help of flange P.V.C. tailpiece by joining the P.V.C. End of Tail- piece and Riser pipe with coupler and flanged end of Tailpiece and Alfa Alfa valve with rubber insertion, Nuts and bolts etc. complete.
Labour charges for fitting, fixing (150 mmx200 mm) dia MS expander with 200 mm dia UPVC pipe with the help of PVC flanged tail piece by joining flanged end of tail piece and expander with rubber insertion nuts and bolts and P.V.C end of tail piece with 200 mm dia. UPVC pipe with coupler all complete.
Transportation of Electro-Motor pumping set for Midi R.L.I Scheme of any make/brand withall accessories and fixtures namly M.S Bend, M.S pipes. Rubber hose, Manifold, Surge Tank, foot valve, Non return valve, sluice valve,priming chamber etc over Pucca/Kancha road from Sub-Divisional store to work site excluding loading and lifting point and unloading at delivery point. i) Distance upto 50 k.m
Installation of Diesel Engine/Electro Motor Pumping set of any make/brand and for RLI scheme on pump foundation over SAL sleeper (to be supplied departmentally) by fixing nuts and bolts and making connection of suction hose and foot valve with necessary fittings at the inlet end of the water pump and fitting fixing of 900 MS priming bend, sluice valve and delivery hose with all necessary fittings at the delivery end of the water pump, duly connected with the pipe line, maintaining proper alignment and level including cutting holes on the wall of the pump house where necessary, mending good damages after completion of the works as per direction of Engineer-in-Charge. (Pump set and all accessories will be supplied departmentally.)a)For Midi R.L.I. Scheme
suppling 1m x 0.6 m x 24 swg MS board contaning list of spout wise water uses by making number of spout as directed by EIC.The board should have base colour Blackand words-white to be fitted and fixing on the wall of the pump house
Supplying, fitting and fixing including transportation of sign board for identifing the exact location of Midi RLI scheme ( one at rode side and other at site) the board will be made 3 mm thick MS plate of 300 mm X 600 mm and fitted and fixed on 50 mm GI Pipe of IS 1239/90 (part-I) including cutting, welding and writting of both sides of Sign board. Base - Yellow, and ward - Red. Both bottom end of the stands pipe will be grouted in 1:2:4 CC on a single brick flat soilng. This will include one materials and labour complite as per drawing and direction of EIC.
Testing of pipe line system against leakage by fillinh the distribution chamber with water and supplying water through the entire pipe line net work for atleast4 (Four) hours by running the departmental diesel Engine pumping set including supply necessary fuel and lubricants and hiring and transporting tools and plant all complete as per direction of Engineer -In -Charge.
Carriage ( 4%) on (Sl no-92-120) except Item No-92,93, 96 & 120
INTERNAL WIRING Fitting of wooden pannel board of size 6ft. X 4ft. X 1 inch. with M.S. clamp on the wall of pump house and made necessary arrangment for fitting fixing the following elctrical equipment including 2 coat of pantigof app.quality as per direction of E.I.C.
Fixing only Sheet Steel Main Switch(Rewirwable type)/ Change over on Flat Iron Frame/Angle Iron Frame on wall 32 Amps On angle iron frame
Fixing only Sheet Steel Main Switch(Rewirwable type)/ Change over on Flat Iron Frame/Angle Iron Frame on wall 63 Amps On angle iron frame
Fitting & fixing of Starter (Direct on Line or Star-Delta/Auto- Transformer) with Nuts & Bolts fixed on Angle iron frame on wall and making necessary connection with the electrical cables. iii) Star-Delta / Auto-Transformer Starter (Above 15 HP upto 25 HP)
Fixing only MS sheet metal busbar Chamber on angle iron frame on wall. 4 bars, 200 Amps. (Busbar will be supplied departmentally)
Meter loop connection with 1.1 K.v. Gr. 3% core 14 core 10 Sqmm to 50 Sq mm. p.v.C.! XLPE insulated & sheathed and armoured Aluminium/Copper Cable from Meter to incomming TPN Main Switch 1 Terminal. (Brand: Gloster/Havells/Finolex) c) For MIDI RLI Scheme i) 35 Sqmm 3% Core Aluminium Cable
Supplying and Drawing with 1.1 KV, PVC flexible 'FR' cables copper conductor conforming to IS 694 in suitable size with fitting and fixing on wall/Kiosk Box , including making necessary connection to the pre-fixed devices with all necessary accessories like saddle, screw, clips, gland, socket etc. conforming to IEE regulation and as per direction of EIC. (Brand: Gloster/Havells/Finolex) [b] For Midi RLI (i) 4Cx 16 sqmm Copper cable conforming to IS 694 in [63 A TPN switch to Busbar
(ii) 3C X 10 sqmm copper cable conforming to IS 694 [Busbar to 32 A. TP Main switch and 32 A TP switch to Motor starter]
(iii) 2 X 3C X 4 sqmm copper cable conforming to IS 694 in 32 mm GI conduit (lSI Medium quality) Star-Delta Motor starter to Motor]
Supplying & fixing bulk head light fitting(Havells Make) on wall / Ceilling incl. S&F suitable 100 watts lamp complete with glass wire-guard and holder.
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. to light/fan/call bell point with Modular type switch (Brand approved by EIC) fixed on Modular GI / PVC switch board with top cover plate on wall incl. mending good damages to original finish. [PVC casing capping and Switch board both on surface] (a) Average run 5 mtr
Connecting the equipments to earth busbar including S & F G (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages (a) Solid GI wire (iii) No. 8 SWG
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA-Medium GI pipe
Supply & Fixing EI danger board on wall 20cm x 30cm ( 8" x 12" )
Insulation testing of internal wiring of Pump House/Kiosk Box including wiring of electric Motor & other ancilary equipments by means of Megger
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Add GST @18% for the item No (66 to 137) on989012.16
cess 1% on for the item No (66 to 138) on 1167034.34
Quotation chagre (including Supervision Charge & Security Deposite)
ENERGISATION OF RLI PCC POLE 9 MTR. LONG
MS CHANNEL 100 X 50 X6 mm
MS. CHANNEL 75X40X6 mm
MS. ANGLE 65X65X6 mm
MS. FLAT 65X6 mm
GI STAY SET HT (1830 X 20 MM) WRKG LD-7900 KG
PORCELAIN GUY INSULATOR HT
GI STAY WIRE 7/3.15 MM
11KV POLYMERVCOMP. WH FTTG PIN INSL 5KN
11KV POLYMERVCOMP. WH FTTG DISC INSL 45KN
COMPOSITE HARD WERE FITTING. FOR 30/50S MM COND
COND ACSR RBT 50 SQ.MM
DTR 63 KVA
LA 12 KV (10KA)
ISL 11KV 200A TPGO
PVC CABLE 50 SQ.4C.
G.I EARTH SPIKE 1833 X 20 MM
G.I WIRE 4MM
G.I WIRE 5MM
GI TURN BUCKLE
LT DISTRIBUTION KIOSK FOR 100KVA TRNF
11 KV "V" BRACKET FOR PCC POLE 9M LONG
11 KV TOP ADAPTOR FOR PCC POLE 9M LONG
ERECTION OF SINGLE PCC POLE 9MTR.LONG WITH FITTINGS
FIXING OF TEE OFF BRACKET ON SINGLE PCC POLE
ERECTION OF PCC POLE 8 MTR
GROUNDING OF HT STAY SET COMPLETE
ERECTION OF EARTHING COMPLETE
STRINGING & SAGGING OF 50 SQ.ACSR(3 WIRE )
FIXING OF CRADDLE GUARD BRACKET ON S.P
FIXING OF CRADDLE GUARD BRACKET ON D.P
FIXING OF LEAD WIRE 3 TO 60 MTR 2W
MAKING FIXING OF CROSS LACING
FIXING OF L A SET COMPLETE
SUPPLY & EARTHING OF LA & OTHER ACCESSORIES TO BE DONE
SURVEY OF 11 KV OH LINE
FIXING OF PIN INSULATOR
FIXING OF DISC INSULATOR
FIXING OF ISOLATOR SET 11 KV COMPLETE
ERECTION OF D.PS /ST STRUCTURE USING 9 MTR PCC POLE
ERECTION OF DISTRIBUTION TRANSFORMER 63 KVA
DTR NEUTRAL EARTHING (NORMAL SOIL)
FIXING OF MS AND KIOSK COMPLETE DOUBLE SWITCH
FIXING OF 3Q SERVICE CONNECTION
Add Sundries @ 5% on item no (141 to 163) materials cost i.e. 5% of Rs. 400825.05
Add GST @ 18% on item no (164 to 184) cost i.e. 18% of Rs.50165.83
Add CESS @ 1% on item no (141 to 185) AND SL NO 186 Total cost i.e. 1% of Rs. 480061.97
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.24 MB
Tendernotice_2.pdf
PDF • 0.83 MB
Tendernotice_3.pdf
PDF • 0.11 MB
BOQ_2438833.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid