| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.2 LAccepted-AOC SECTOR 10 PANCHKULA | PANCHKULA | PANCHKULA | HARYANA | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.9 L+₹1.6 L (6.96%)Rejected-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L2 | Rejected-AOC L2 | |
| 3 | L3₹26.4 L+₹3.1 L (13.1%)Rejected-AOC | L3 | Rejected-AOC L3 |
Tender Value
₹32.4 L
EMD Value
₹64,780
Closing Date
28 Oct 2019, 6:00 pmClosed
Sh AP Singh, IDSE, SE
HQ CWE Chandimandir
CA NO CWE/CHM(U)-43/2019-20 REPAIR/MAINT OF SEWAGE ASSETS AT COMMAND HOSPITAL SEWAGE INSTALLATION, INTERMEDIATE, VATIKA AND OLD STP AT CHANDIMANDIR
2019_MES_285608_1
CWE/CHM(U)-43/2019-20
Open Tender
Miscellaneous Works
Item Rate
180 days
HQ CWE Chandimandir
Class D, Cat a(ii)
7 documents required · 7 mandatory
₹500
Yes
GE (U) Chandimandir
₹64,780
Yes
3 Jan 2020
27 Sept 2019
30 Oct 2019
27 Sept 2019
28 Oct 2019
11 Oct 2019
Amount
M&L for pumping out of STP water from the 50000 gallons capacity under ground sump (open from the top) by means of suitable pumping set of appropriate capacity and thorough cleaning of the sump by rubbing, scrapping the surfaces and taking out all the foreign materials, silt, mud, sludge etc from the sump including vegitation from the unit and disposing off at confined places in barrow pits and covering the barrow pits with 15 cm thick layer of soil, distance not less than 500 mtrs and applying two coats of white wash on the entire internal surfaces complete all as specified and directed.
All as per item No 1 here-in-before but of capacity 10000 gallons.
All as per item No 1 here-in-before but of capacity 40000 gallons. Note1 to 3:- Necessary T&P , pumping set, pipes etc shall be arranged by the contractor. Required safety equipments such as hand gloves, headgears, masks, gum boots, oxygen gas cylinders and any other necessary safety eqpt/material etc shall also be arranged by the contractor. Labour trained in cleaning of sewerage sumps shall only be deployed to carry out the above job. Entire responsibility for safety of the deployed labour shall be of the cotractor and deptt shall not be responsible for any mishappening or any type of loss occured during the execution of above job. Unit rate quoted shall be deemed to include the cost of all the above factors with & incl digging out borrow pits nd covering the same with soil, no extra payment shall be made for the same at any stage.
Disconnecting electrically, mechanically & taking out from the sewerage water well , submersible type non clog pump sets of capacity 15/30 HP by means of chain pulley blocks of suitable capacity complete with column pipes, cables, supporting chain etc to carry out necessary repairs complete all as directed. (Depth of the well is appx 12 Mtrs)
Lowering of the repaired submersible type non clog pump sets of capacity 15/30 HP by means of chain pulley blocks of suitable capacity complete with column pipes, cables, supporting chain etc into the sewerage water well and connecting electrically and mechanically incl testing for proper working complete all as directed. (Depth of the well is appx 12 Mtrs)
M&L for disconnecting the electric motor from the non clog type submersible sewage pump, shifting to workshop, dismantling the defective 30 HP 3 phase 415 volts submersible type motor of any make for removing the burnt out windings from the stator , cleaning the slots of the stator properly, rewinding of stator with best quality PVC isulated copper winding wire of appropriate gauge all as per existing incl all insulating materials, tapes, PVC sleeves , connecting leads with sleeve etc and cleaning of rotor assembly with soft cloths , reassembling the electric motor , shifting back to the site , reconnecting with the pump and testing for proper working complete all as directed.
All as per item No 6 here-in-before but motors of 15 HP capacity.
M&L for dismantling 30 HP capacity sewage water non clog submersible pump set of any make , repairing by replacement of pump shaft, GM neck rings, pump impeller, water seals/ impeller keys, lock nut, thrust block , gaskets and reassembling the same,shifting back to site and testing for satisfactory working complete all as directed.
All as per item No 8 here-in-before but pumps of 15 HP capacity.
Taking up or down ductile iron/Cast Iron pipes 250 mm bore and removing from site (including all fittings) with spigot & socket ends complete all as directed. Note:- Excavation and earth work shall be measured and paid for separately.
Taking up or down ductile iron/Cast Iron pipes 150 mm bore removing from site (including all fittings) with spigot & socket ends complete all as directed. Note:- Excavation and earth work shall be measured and paid for separately.
Supply, laying, jointing and testing of ductile iron pressure pipe with socket & spigot ends confirming to IS:8329/2000 in standard length of 5.50 - 6.00 meter of classification K-7 suitable for push on rubber tyton (gasket D-jointing) with cement mortar lining in the pipes having 250 mm bore and testing the joints for any leakage with required water pressure complete all as specified & directed. Note:- Joints and CI/DI specials shall be measured and paid for separately under respective items.
All as per item No 12 here-in-before but for bore of pipe 150mm.
S&F in repair ductile iron pipe fittings such as bends, tapers, tee pieces single branch, "Y" junction, collars, caps and plugs etc spigot socketed or flanged ends type of size upto 250 mm nominal bore conforming to IS-9520/2000 with pressure rating PN-1 (all the fittings shall be coated for rust prevention i.e. external coating zinc rich paint with finishing layer of bituminous as per Annexure - A of IS:9523/2000 and internal lining shall be of cement mortar with seal coat as per Annexure 'B' of IS-9523/2000) complete all as specified and directed. Note:- (i) Joint and jointing material shall be measured and paid separately. (ii) Excavation and earth work shall be measured and paid for separately.
Supplying, fixing, jointing and testing mild steel black pipe with flanged ends ISI Marked, Fe 410 grade as per IS:1239/2004 nominal bore 150 mm, medium grade (Class B) in standard length of 5.50 - 6.00 meter complete incl jointing materails such as nuts/bolts/washers/rubber gaskets etc all as specified and as directed.
Cutting to existing CI/DI pipe line of size 150mm dia required for repair/replacement of pipe line and insertion of collars/tail pieces, tee etc including bailing out of leaking water if any, complete all as specified and directed.
All as Item No. 16 here-in-before but 250 mm dia.
M&L for rubber ring tyton push joints ISI marked suitable for spigot & socketed ends DI pipe and fittings for size upto 150 mm bore as per IS: 5382 with jointing material complete all as specified and directed.
All as per item Sr No: 18 here-in-before but 250 mm bore.
Disconnecting and taking out old unserviceable sluice valves, foot valves, NRVs of any type and dia 100/150/200 mm complete all as directed.
S&F cast iron sluice valve 150 mm bore with flanged ends and SS stem (AISI 410) class PN 1.6 non rising stem type with hand wheel operation, duly ISI marked complete including all jointing materials such as nuts, bolts, washers, rubber gaskets etc all as directed. Make :- Leader/BIR/Kartar/Zoloto.
All as per item No. 21 here-in-before but of size 100mm bore
S&F column pipes with flanged ends made from 100 mm dia MS black pipe medium grade class B with and incl 10 mm thick MS flanged dully welded at the ends drilled with holes for bolts incl jointing materails such as nuts/bplts/washers/rubber gaskets etc complete all as directed.
S&F cast iron foot valve flanged type of size 200 mm dia complete incl all jointing materials such as nuts, bolts, washers, rubber gaskets etc all as directed. Make:- Leader/BIR/Kartar/Zoloto.
All as Item No.24 here-in-before but 150 mm dia.
S&F cast iron non return valve with flanged ends of size 200 mm dia complete incl all jointing materials such as nuts, bolts, washers, rubber gaskets etc all as directed. Make:- Leader/BIR/Kartar/Zoloto
All as Item no. 26 here-in-before but 150 mm dia.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation etc or for laying pipe lines and cables and getting out as in hard/dense soil complete all as specified and directed.
Returning filling in including spreading leveling, watering and well ramming in layer not exceeding 25 cm in hard/dense soil, complete all as specified and directed.
Removing excavated material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provived for (foundation of pump sets) including disposal of unserviceable material complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate for pump set foundations etc, including necessary form work complete all as specified and directed.
Demolition of brick work built in cement mortar including all quoins, arches, piller etc complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks, straight or curved on plan to exceeding 6m mean radius, built in 1:4 cement mortar complete all as specified and directed
M&L for 10mm thick rendering in cement mortar 1:4 on fair faces of brick wall or concrete surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate for lean concrete etc, including necessary form work complete all as specified and directed.
M&L for clearing of pump house area by digging out bushes, shrubs , wild grass etc and levelling the surface complete all as directed.
Taking down old rusted valve pit frames , sheet covers, railigs etc complete all as directed.
M&L for MS framed work such as grills, valve pit frames, fencing post ,walk ways railings, frame work of water tank and similar work confirming to Fe-290 Gde E-165 etc with angle irons, channels etc complete all as specified and directed .
M&L MS black sheet 3mm thickness as in valve pit cover incl painting work with two coats of black bitumouns paint over a coat of red oxide primer complete all as directed.
M&L foundation bolts 600 mm long for pump sets made from 20 mm dia MS rod duly threaded at top upto 200 mm lenth with and including two MS nuts and 3 mm thick washers complete all as directed.
Disconnecting electrically and mechanically centrifugal pump set of capacity 20/25/30 HP and taking down from the existing PCC foundation and refixing the same at the original postion after repairing of PCC foundation incl reconnecting electrically and mechanically and testing for proper working complete all as directed. Note:- Reparing of PCC foundation shall be measured and paid separately.
All as Item No. 42 here-in-before but capacity 40/50 HP.
All as Item No. 42 here-in-before but capacity 60/75 HP.
Disconnecting electrically and mechanically centrifugal pump set of capacity 20 HP and taking down from the existing PCC foundation at underground sewage pump house , taking out using proper T&P, chain pulley block, ropes, chains etc and refixing the same at the original postion after repairing of PCC foundation incl reconnecting electrically and mechanically and testing for proper working complete all as directed. Note:- Reparing of PCC foundation shall be measured and paid separately.
Dismantling the existing suction lines and delivery lines by cutting/removing the rusted nuts & bolts of 20 HP pump sets of size 100/150 mm dia including all fittings/valves etc , taking out from the under ground sewage pump house and cleaning properly internally with wire brushes/iron rods etc to clear any blockage , refixing the same and testing for proper working complete all as directed. (Appx length 20 RM) incl all nuts/bolts/gaskets etc and painting with two coats of black bitumonous paint complete all as directed. Note:- Work for item no 45 & 46 is to be carried out at under ground sewage pump house at a depth of appx 12 mtrs.Necessary T&P , required safety equipments such as hand gloves, headgears, masks, gum boots, oxygen gas cylinders etc shall also be arranged by the cotractor. Entire responsibility for safety of the deployed labour shall be of the cotractor and deptt shall not be responsible for any mishappening or any type of loss occured during the execution of above job. Unit rate quoted shall be deemed to include the cost of all the above factors and no extra payment shall be made for the same.
Disconnecting electric supply and taking out old unserviceable panels incl all accessories/starters etc complete all as directed.
Supply, installation, commissioning and testing Polycarbonate CPRI approved OEM made LT Panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel should be anti-acid & anti corrosive. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of board/panel shall submit a copy of CPRI TEST REPORT IN POLYCARBONATE OF DEGREE OF INGRESS PROTECTION IP65 IN ACCORDANCE WITH IEC 60529. The gasket should be internally embedded made of polyurethane. The manufacturer of board/panel SHALL submit a copy of TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of tests performed and passed out satisfactorily such as Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer must submit the copy of test reports for Polycarbonate
Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Guarantee and warrantee certificates will be accepted only from original manufacturer. The panel should passed glow wire test 960oC in accordance with 60695-2-11 flame retardant and self-extinguishing. Make- Hensel/L&T/Schneider. (i) MCCB four pole 160 amps capacity 25 KA 415 volts - 01 No (Incoming) and copper strip bus bars TPN 150 amps capcity sleeve insulated in color code mounted on epoxy insulators - 01 set. (ii) MCCB four pole 32 amps capacity 16 KA 415 volts - 05 No (Outgoing). (iii) MCB four pole 32 amps capacity 415 volts - 01 No ( Outgoing). (iv) Three phase digital Multi Function Meter - 01 No. (v) LED indicator RYB - 03 Nos and earthing terminals - 02 Nos. (vi) Complete wiring of panel board circuits with single core copper conductor FRLS cable of suitable size incl 6 amps SP MCB 6 amps capacity in each circuit for protection. (vii) PCC foundation of suitable size for fixing of the panel board complete.
Supply, installation, commissioning and testing Polycarbonate CPRI approved OEM made LT Panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel should be anti-acid & anti corrosive. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of board/panel shall submit a copy of CPRI TEST REPORT IN POLYCARBONATE OF DEGREE OF INGRESS PROTECTION IP65 IN ACCORDANCE WITH IEC 60529. The gasket should be internally embedded made of polyurethane. The manufacturer of board/panel SHALL submit a copy of TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of tests performed and passed out satisfactorily such as temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer must submit the copy of test reports for Polycarbonate
Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Guarantee and warrantee certificates will be accepted only from original manufacturer. The panel should passed glow wire test 960oC in accordance with 60695-2-11 [flame retardant and self-extinguishing. Make- Hensel/L&T/Schneider. (i) MCCB four pole 200 amps capacity 35 KA 415 volts - 01 No (Incoming) and Copper strip bus bars TPN 300 amps capcity sleeve insulated in color code mounted on epoxy insulators - 01 set. (ii) MCCB four pole 100 amps capacity 25 KA 415 volts - 03 No (Outgoing). (iii) Three phase digital Multifunction meter - 01 No. (iv) LED indicator RYB - 03 Nos and earthing terminals - 02 Nos. (v) Complete wiring of panel board circuits with single core copper conductor FRLS cable of suitable size incl 6 amps SP MCB 6 amps capacity in each circuit for protection. (vi) PCC foundation of suitable size for fixing of the panel board complete.
Supply, installation, testing and commissioning of fully automatic star delta starter suitable for 25 to 60 HP capacity with, installation, commissioning and testing Polycarbonate CPRI approved OEM made LT Panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel should be anti-acid & anti corrosive. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of board/panel shall submit a copy of CPRI TEST REPORT IN POLYCARBONATE OF DEGREE OF INGRESS PROTECTION IP65 IN ACCORDANCE WITH IEC 60529. The gasket should be internally embedded made of polyurethane. The manufacturer of board/panel SHALL submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following tests performed and passed out satisfactorily: Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective
Circuits. The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Guarantee and warrantee certificates will be accepted only from original manufacturer. The panel should passed glow wire test 960oC in accordance with 60695-2-11 [flame retardant and self-extinguishing. Make- Hensel/L&T/Schneider. suitable for 3 phase 415 volts 50 Hz 4 wire AC supply compltet all as directed with and incl the following:- (i) 3 pole power contactor 415 volts Ac, 50 Hz, current rating AC-1 140 amps and AC-3 80 amps with one pair of auxillary contacts (01 NO+01 NC) Cat part No MCE15LN3-5 of Make BCH citation series - 03 Nos. (ii) Digital type protection relay with display having protection for over current, under current , phase loss, phase imbalance, phase reversal Model BOCR 3 DE - 01 No. (iii) Timer electronic Make BCH - 01 No.
(iv) LT CTs resin cast type 100/5 amps set of 03 CTs - 02 No ( One for metering and one for BOCR protection. Make:- AE/Alliance/Kappa. (v) 6 mm thick backelite mounting sheet of suitable size. (vi) Push button unit with element for ON/OFF (Green/ Red color) - 02 Nos Make BCH. (vii) Internal wiring of the circuits with FRLS copper conductor cable of size 1,5 sqmm incl 6 amps SP MCB in each circuit for protection. (viii) Digital ammeter 0-100 amps square flush type of size 96x96 mm - 01 No Make :- AE/L&T/Schneider. (ix) Internal connetions of contactors with copper strip of appropriate current carrying capacity sleeve insulated in color code with brass nuts/bolts/washers and incl epoxy insulators as per requirement. Note:- Make of item No (i), (ii) and (iii) BCH as specified above or equiv model of Make :- Siemens/ABB. Contractor shall provide all these items of one make only.
M&L for disconnecting electrically from power supply and mechanically from the pump , taking down the defective 20 HP 3 phase 415 volts squirrel cage induction electric motor of any make from the foundation and dismantling the same for removing the burnt out windings from the stator , cleaning the slots of the stator properly, rewinding of stator with best quality super enamelled copper winding wire of appropriate gauge all as per existing incl all insulating materials, varnishing & drying properly , connecting leads sleeve insulated up to terminal block and connections, cleaning of rotor assembly with soft cloths , reassembling the electric motor , shifting back to the site , refixing on the foundation and reconnecting electrically & mechaniclly, testing for proper working complete all as directed. Note:- Required T&P and transportation shall be arranged by the contractor and unit rate quoted will be deemed to incl the cost of the same.
All as per item No 51 here-in-before but 25 HP capacity.
All as per item No 51 here-in-before but 30 HP capacity.
All as per item No 51 here-in-before but 50 HP capacity.
All as per item No 51 here-in-before but 60 HP capacity.
All as per item No 51 here-in-before but 75 HP capacity.
Supply only ball bearings for DE/NDE suitable for 20 HP 3 phase 415 volts squirrel cage induction motor of any make complete all as directed. Make :- SKF/TATA/NBC.
All as per item No 57 here-in-before but for 25 HP.
All as per item No 57 here-in-before but for 30 HP.
All as per item No 57 here-in-before but for 50 HP.
All as per item No 57 here-in-before but for 60 HP.
All as per item No 57 here-in-before but for 75 HP.
M&L for disconnecting the defective 20/25/30 HP centrifugal pump from the electric motor and suction/delivery pipe lines, taking down from the foundation, shifting the pump to city workshop for repairing/servicing, dismantling the pump complete, replacment of defective parts as required, cleaning of all the parts incl lubrication/greasing etc, reassembling and shifting back to origanal site , reinstalling and making all connections incl testing for satisfactory working complete all as directed.Note:- Spare parts shall be measured and paid separately under respective item. New joints of suction/delivery blines shall be measured and paid separately.
Supply only the following items suitable for 20/25 HP pump complete all as directed:-
Ball bearings for DE/NDE Make :- SKF/TATA/NBC
Gun metal sleeves for pump shaft
SS key set for pump shaft
Check nut
Water seal
CI stuffing box gland set
Gasket set
CI impeller as per manufactureer,s design and dimensions
M&L for remetalling, turning , grinding , polishing etc of the main pump shaft of 20 HP capacity pump of any make to match all the dimensions with the original complete all as directed.
All as per item No 65 here-in-before but 25 HP capacity.
All as per item No 65 here-in-before but 30 HP capacity.
Supply only the following items suitable for 30 HP pump complete all as directed:-
Ball bearings for DE/NDE Make :- SKF/TATA/NBC
Gun metal sleeves for pump shaft
SS key set for pump shaft
Check nut
Water seal
CI stuffing box gland set
Gasket set
CI impeller as per manufactureer,s design and dimensions
M&L for disconnecting the defective 50/60/75 HP centrifugal pump from the electric motor and suction/delivery pipe lines, taking down from the foundation, shifting the pump to city workshop for repairing/servicing, dismantling the pump complete, replacment of defective parts as required, cleaning of all the parts incl lubrication/greasing etc, reassembling and shifting back to origanal site , reinstalling and making all connections incl testing for satisfactory working complete all as directed.Note:- Spare parts shall be measured and paid separately under respective item. New joints of suction/delivery blines shall be measured and paid separately.
M&L for remetalling, turning , grinding , polishing etc of the main pump shaft of 50 HP capacity pump of any make to match all the dimensions with the original complete all as directed.
Supply only the following items suitable for 50 HP pump of any make complete all as directed:-
Ball bearings for DE/NDE Make :- SKF/TATA/NBC
Gun metal sleeves for pump shaft
SS key set for pump shaft
Check nut
Water seal
CI stuffing box gland set
Gasket set
CI impeller as per manufactureer,s design and dimensions
M&L for remetalling, turning , grinding , polishing etc of the main pump shaft of 60 HP capacity pump of any make to match all the dimensions with the original complete all as directed.
Supply only the following items suitable for 60 HP pump of any make complete all as directed:-
Ball bearings for DE/NDE Make :- SKF/TATA/NBC
Gun metal sleeves for pump shaft
SS key set for pump shaft
Check nut
Water seal
CI stuffing box gland set
Gasket set
CI impeller as per manufactureer,s design and dimensions
M&L for remetalling, turning , grinding , polishing etc of the main pump shaft of 75 HP capacity pump of any make to match all the dimensions with the original complete all as directed.
Supply only the following items suitable for 70 HP pump of any make complete all as directed:-
Ball bearings for DE/NDE Make :- SKF/TATA/NBC
Gun metal sleeves for pump shaft
SS key set for pump shaft
Check nut
Water seal
CI stuffing box gland set
Gasket set
CI impeller as per manufactureer,s design and dimensions
M&L in repairs cable terminal block with brass nuts/bolts/washers along with cover suitable for 20/25 HP 3 phase 415 volts 50 Hz star delta connected AC induction motor of any type complete.
All as per item No 76 above but 30 HP.
All as per item No 76 above but 50 HP.
All as per item No 76 above but 60 HP.
All as per item No 76 above but 75 HP.
Disconnecting the inlet/outlet pipe connections and taking down old damaged PVC water tank of capacity 500/1000 ltrs complete all as specified and directed.
Taking down old rusted GI pipes of 25 mm dia incl all fittings complete all as specified and directed.
Taking down old damaged gate valves of size 25 mm dia complete all as specified and directed.
Supply and fixing rotational moulded polythelene water storage tanks ( cyliderical vertical with closed top ) hoisted and fixed in position all as specified in SSR part-1 of capacity 500 ltrs complete all as direceted.
All as per item No 84 here-in-before but capacity 1000 ltrs.
M&L tubes medium grade 25 mm dia laid on walls/roofs etc incl all fittings such as bends/union/elbow/socket/reducer/tee etc complete all as direcetd.
S&F tank nipple complete with all fittings of size 25 mm dia.
S & F Gun Metal gate valve with iron wheel head screwed both ends for iron pipes of 25 mm dia complete all as directed.
M&L for earthing complete with galvanised steel earth plate electrode of size 600x600x6 mm thick burried directly in ground with earth pit not less than 2.25 mtr deep below normal GL and with top edge of the plate not less than 1.5 mtr deep below normal ground level connected to GI strip earth lead of size 32x6 mm by means GI nuts/bolts/washers complete incl charcoal dust, salt, 20 mm dia med grade watering pipe with funnel and wire mesh, 40 mm dia med grade GI protection pipe complete all as per electric plate No 3 on SSR Part-I, PCC pit and CI cover, earth work in any type of soil complete excavation, refilling, removal of surplus soil etc complete all as directed incl test point and testing on completion all as directed. Note:- Earthing test results shall be prepared by the contractor and submitted to the Engr-in-Charge. Earthing resistance shall be to the entire satisfaction of Engr-In-Charge. GI strip 32x6 mm and 40 mm dia GI protection pipe shall be measured and paid separately.
M&L tubes medium grade 40 mm dia laid for protection of 32x6 mm GI strip earthing lead complete all as directed.
M & L GI strip 32x6 mm laid as erathing lead and erthing continuity conductor complete all as directed.
S & F aluminium strip 25 x 5 mm laid as earthing continuity conductor and for earthing connection complete all as directed.
Disconnecting and taking out old unserviceable submain wiring incl conduits etc of any size/type complete all as directed.
Sub main wiring (with approved colour coding as per IS) with two core FRLS PVC insulated multistranded copper conductor cable 1.1 KV grade fo 2.5 sqmm and one run of single core FRLS PVC insulated flexible stranded copper conductor 1.1 KV grade of 1.5 sqmm as earth wire in concealed conduits complete all as specified and directed. Notes : (i) Conduit & conduit accessories shall be measured and paid separately. (ii) For payment purpose, two runs of main cable and one run of earth cable shall be considered together as "1RM".
All as per item No 94 here-in-before but single core of 10 sqmm and one run of 6 sqmm.
S & F in repairs LED flood light luminaire of capacity 100 watt with secondary optics made in pressure die cast housing with heat sink and aluminium extrusion with IP 66 of capacity 100 watt dully fixed on wall with and incl 10 mm dia 150 mm long anchor bolts . Cat No BARFEG100W LED of Make Bajaj or equivalent as mentioned in Appx 'B'.
S & F in repairs LED tube light fitting batten type complete with batten, LED tubelight 18 watt capacity and two nos square PVC blocks dully fixed on wall complete all as directed. Cat No BLRBDB 118 for batten and BLRB18WCWc for LED tube light Both of Make Bajaj or equivalent as mentioned in Appx 'B'.
Disconnecting and taking out old unserviceable aluminium/copper conductor cable incl flexible pipe of any type and size complete.
Supply, laying, connecting and testing of PVC insulated and PVC sheathed copper conductor flat submersible cable 3 core 25 sqmm 1100 volts grade complete all as directed.
Supply, laying, connecting and testing of PVC insulated HRFR copper conductor single core 16 sqmm 1100 volts grade complete all as directed.
S&F in repairs PVC flexible conduit 40 mm dia heavy grade best quality fixed with C shape clamps of suitable size complete all as directed.
Dismantling fencing wire, wire mesh, incl line wire any type complete all as specified and directed.
Fixing only chain link fencing incl line wires, any mess, size and type to any type of standards, rails, straining bolts etc incl provision of bending wire etc complete all as specified and directed.
Supply only chain link fencing of 3mm dia galvanised steel wires, size of mess as approved by GE complete all as specified and directed. Note : - Unit weight (weight per sqm) of chain link fencing shall be derived as per actual site measurement through a BOO conveyed by GE.
M&L for mild steel round bars 10mm dia for horizental tie bars of fencing posts etc incl necessary welding, overlapping etc complete all as specified and directed.
R D Bansal
WR Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .