Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 LAccepted-AOC D NO 8 11 PONNAGARAM SITHAR KOVIL KOSAVAPATTY PO EDANGANSALAI SALEM 637 502 | SALEM | SALEM | TAMIL NADU | 637502 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹11.2 L+₹12,922.65 (1.17%)Rejected-AOC | L2 | Rejected-AOC Rejected |
Tender Value
₹13.2 L
EMD Value
₹13,200
Closing Date
11 Jan 2024, 3:00 pmClosed
Commissioner
Pudukkottai Municipality
CONSTRUCTION OF ANGANWADI BUILDING AT WARD NO.21 PUDUKKOTTAI MUNICIPALITY
2024_MAWS_406569_1
9309/2023/E1
Open Tender
Civil Works - Buildings
Lump-sum
180 days
Pudukkottai
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹13,200
22 Jan 2024
6 Jan 2024
11 Jan 2024
6 Jan 2024
11 Jan 2024
6 Jan 2024
Amount
Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete
Foundation
Grade beam
Supplying and filling with good clean river sand for foundation and basement including all cost and conveyance of all materials and labour charges etc. complete as per standard specification.
P.C.C 1.4.8 (one cement four sand and eight aggregate) using 40mm ISS HBG metal Including cost and conveyance of all materials and labour charges complete as per Standard specification
Random rubble masonry in cement motor 1:5 (one Part of cement, Five part of Crushed Stone Sand (M- Sand)) mix using all granite stones and bond stones for foundation and basement from approved quarry including watering, curing, and labour charges etc., completed as per standard specification
Supply and erection centring for sides and soffits of all RCC works including cost and convyance of all materials to site and labour charges etc, complete. as per standard specifications
Column
Beam and Slab
Suppling and fabricating MS (or) R.T.S. bar as per the design given including cost of steel and binding wire also in all floors -1 etc., completed per standard specification
Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers -
Brick work in CM 1:5 (one cement & Five Crushed Stone Sand (M- Sand)) using II class ground moulded bricks of size 9" X 43/8"X 2 3/4" including finishing, curing, etc., complete complying with standard specification - 100CFT
Blow basement
Above basement
Supplying and filling in foundation and basement with Well Gravel in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification.
Manufacturing supplying and fixing of steel door with the following specification MS angels of size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames stiffeners with 32 x 6mm M.S flat is provided at required intervals in the shutter frame. 18-gauge C.R. sheet laid as panel in the shutter and welded intact. M.S. flat 18x5mm is welded over the 32 x 6mm M.S. flat sandwitching the C.R. sheet in between additional stiffeners with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter, 3nos. of hinges in case of single leaf and 6nos. of hinges in double leaves shutter to be provided 6nos. of holdfasts 120 mm in length made of angle section spliced at the ends are welded to the outer frames of the door. Tower bolts 2nos. one at the top and the other at the bottom are provided 1no. Aldrop is provided incase of double leaf door at lock rail section in the door in single leaf door, one more aldrop is provided in the inner lock rail section of the door One rotaing locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place. Incase of double leaf door M.S.Flat 32 x 3mm at 1.1Kg/m is provided on the one shutter t conceal the gap between the two shutters.at an appropriate place in the door. A tie bar is provided at the bottom of the frame to prevent twisting of frame during transportation and fixing. All members are given a coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation to site of work, loading, un loading and all other incidental charges etc., complete.
Supply and fixing of RCC JOLLY including cost and conveyance of all materials and all labour charges etc, complete
Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification.
Special ceiling plastering with cement mortor 1:3 mix to 10mm thick including cost and conveyance of all materials to site and all labour charges etc, complete
Plastering with Cement mortar 1:5mix (One cement and five sand) with 12 mm thick etc., including cost and conveyance of all materials and labour charges etc., complete as per standard specification.
Paving the floor with Double charged Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. The colour & quality of tiles should be got approved by Municipal Engineer before use on work
Dadooing walls with Glazed tiles of sizes 305mm X 200mm X 6mm size of approved make and quality and colour Set in cement mortar 1:2 (One part of Cement and two part of Plastering Sand (P- Sand)) over 10 mm base layer plastering and pointing with white cement neatly as directed.
Supplying and fixing in position Indian water closet of size 580 X 440mm, white glazed earthen ware of approved quality with 'P' trap or 'S' trap confirming to IS:2556 - Part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 ( one part of lime, two parts of sand and five parts of brick jelly) 100mm thick and finishing the top to required slope and including giving necessary connection to cast iron soil pipes/ PVC pipes by dismandling brick masonry, reinforced cement concrete roof/floor slab and making good the disturbed portion to original condition without leakage etc., complete complying with standard specifications and as directed by the departmental officers.
White washing two coaats using best freshly burnt white shell lime in all the floors, including cost of lime blue powder fevicol, type gums, brushes, scaffolding charges etc, complete with standard specification.
Painting two coats with ready mixed Plastic Emulsion Paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification.
Painting two coats of new iron works such as steel doors, Windows, Ventilators window bars, Balustrades, etc, with best approved first quality of synthertic enamel paint of apporved colour over the existing priming coats etc, complete.
Paving the floor with fine polished cuddapah stone slab of following thickness over Cement Mortar 1:3 (One Cement and Three crushed stone Sand) 20mm thick over the existing bed of Cement Concrete 1:5:10, (One Cement, Five crushed stone sandand Ten aggregate) and pointing the joints to full depth of slabs with same mortar mixed with black oxide and the top surface rendered smooth, curing, etc., The cuddapah stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete complying with standard specification.
Providing & fixing PVC RAIN WATER DOWNFALL PIPE of the following dia with necessary T.W.Clamps Plugs, Shoes,Bemds, other clamps, screws nails etc.,complete complying with standard specification. The rate is inclusive of cost of removable iron gratings of appropriate size. The size of Teak Wood plugs used is 150X25mm in front & 200x75mm in rear (wall side) with a depth of 110mm. The pipe is to be fixed by means of "U" clamps at the centre of pipes to be fixed.110mm dia PVC Pipe [4 Kg/SqCm]
Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade insuitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box inflush with wall with 5A FTswitch covered with hylum sheet of 3mm thick with painting of suitable colour with continuous earth wireconnection of 14 SWG TC wire for open PVC light point / fan point (for electronic regulator (As per S.D.19) SOR 2023-24
Fan point
Light point
Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100Vgrade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with 150mm x 100mm x75mm MS switch box inflush with wall with 3mm thick hylum sheet cover for 5A 3pin non interlocking flush type CS plug with painting of suitable colour with continuous earthwire connection of 14SWG TC wire for open plug point (SD No.11) 2023-24
Supply and run of 2 of 4 sq.mm. (56 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V on 7 / 20 GI bearer wire for service connection mains.(As per SD No.138)2023-24
Supply and fixing of single box type 4'40W fluorescent fitting complete with copper choke and condensor with TWround blocks on wall or ceiling with flu tube with PVC unsheathed copper leads from terminals to the fitting
Supply and run of 2 of 4 sq.mm (56/0.3) PVC inculated SC unsheathed Cu. Conductor of 1100 V grade in 25mm dia GI pipe ( Class 'B') suitably bent at both ends with necessry angle iron upright and end.(SD No.68)
Supply and fixing of 1200mm (48") AC ceiling fan complete with stepped electronic 300W regulator with 1 meter down rod on the existing clamp (as per SD 107)
FRP Door Sutter with FRP Door Frames made out of FRP Sheets of 3mm thick of over all size 65mm x 50mm with rebate suitably reinforced using MS Angle / Flats, cost of holdfasts and Solid Core FRP Shutter Panel of 5mm thick and hollow core frames of 3m wall thickness for styles and rails etc., of sizes specified by Engineers
S VAHITH ALI
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_483819.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .