Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.9 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹26.8 L+₹1.8 L (7.30%)Rejected-Finance | L2 | Rejected-Finance Rejected due to higher rate than L1 | |
| 3 | L3₹26.8 L+₹1.9 L (7.49%)Rejected-Finance | L3 | Rejected-Finance Rejected due to higher rate than L1 |
Tender Value
Refer Docs
EMD Value
₹57,000
Closing Date
30 Mar 2021, 6:00 pmClosed
COL NK SAH
CWE (AF) LOHEGAON, PUNE-411032
SPECIAL REPAIR FOR MAINTENANCE OF ROOF, STRUCTURES /JOINERY AND OTHER MISCELLANEOUS REPAIRS OF 10 BUILDINGS AT KANHERI HILLS UNDER GE (AF) THANE
2021_MES_426086_1
82593/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) THANE
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE (AF) Thane
₹57,000
Yes
22 May 2021
26 Feb 2021
7 Apr 2021
26 Feb 2021
30 Mar 2021
15 Mar 2021
Amount
Surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting out complete all as specified and as directed by Engr-in-charge.
M&L for Hardcore of gauge n exc. 63mm, Broken stone or boulders deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed by Engr-in-charge.
Material and labour for providing plain cement concrete type B- 1, (1:2:4) using 20mm graded stone aggregate as in roof padding laid in slope as per requirement mixed with integral water proofing liquid admixture as per manufacturer's instructions complete all as specified and as directed by Engr-in-charge. Note : (i) Minimum thickness of PCC shall be 50mm. (ii) Integral water proofing liquid admixture shall be measured and paid separately under appropriate item here in after.
M&L for Pre-cast cement concrete block masonry 1:3:6 Type C-1 (using 20mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified and as directed by Engr-in-charge.
Material & labour for providing reinforced cement concrete (1:1½: 3) type B0 (using 12.5mm graded stone aggregate) mixed with integral water proofing liquid admixture CONPLAST X421IC (Fosroc) or equivalent as per manufactures instructions as in columns, pillars, lintel, slab supported walls roof, landings, balconises, canopies, deck slabs and in shelves etc complete all as specified and as directed by Engr-in-charge..
Supply only integral water proofing Liqued admixture complete complete all as specified and as directed by Engr-in-charge.
Cutting holes in brick walls exc half bricks but n exc one brick built in cement mortar or cement lime mortar for inserting holdfasts and making good dismantled portion in cm (1:3) or cement concrete (1:2:4) type B1 as required complete complete all as specified and as directed by Engr-in-charge.
S&F IInd class hard wood plain, solid, straight chowkat and frame wrought framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed by Engr-in-charge.
S&F for 35mm thick IInd class hard wood glazed and skelton shutters divided into squares with plain chamfered or reounded miltred and related sash bars number to received glass gauze etc edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part-I section 8 clause 8.20(a) supplied and fitted to chowkats complete complete all as specified and as directed by Engr-in-charge.
S&F for 35mm thick IInd class HW rail and style plain framed panelled factory made shutter (Two panel) with lock rail and panel of 9mm BWP, commercial ply or 12mm veneered particle beard with commercial veneering on both faces. The size of rail and stile as per IS :1003 (Part-I) kiln and chemically pressure treated complete all as specified and as directed by Engr-in-charge.
Taking down chowkats with shutters of any description exc 2.00 sqm each and removing to or from store complete all as specified and as directed by Engr-in-charge.
Taking down shutters of size exc 1 sqm and n exc 2 sqm each and refixing in the same opening including necessary adjustment after laying of floor tiles complete all as specified and as directed by Engr-in-charge.
S&F aluminium anodized barrel tower bolt extruded section and fixed 200mm long complete all as specified and as directed by Engr-in-charge.
S&F door sliding bolt aldrop 250 mm long aluminium anodised complete all as specified and as directed by Engr-in-charge.
S&F but hinges mild steel medium weight 100mm long complete complete all as specified and as directed by Engr-in-charge.
S&F Floor door stopper 150mm length of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and as directed by Engr-in-charge.
S&F Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete complete all as specified and directed by Engr in Charge.
S&F in repair mild steel 300mm ordinary rat tail rod pettern springs including roller and roller plate complete all as specified and as directed by Engr-in-charge.
S&F extruded aluminium alloy handles 100mm fabricated type, anodised complete all as specified and as directed by Engr-in-charge.
S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc., n exc 10 kg each brackets, conforming to Fe 410-0 or Fe 310-0 (Brackets over 10kg each to be measured under `Structural Steel') complete all as specified and as directed by Engr-in-charge.
M&L for 25 x 3mm mild steel FI holdfasts complete all as specified and as directed by Engr-in-charge.
M & L for pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engr-in-charge.
Opening out cracks, V section of wall/roof removing the loose material. Filling with cement mortar 1:3 complete all as specified and as directed by Engr-in-charge.
M&L for 100mm thick PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in finishing surfaces of concrete, finish topping even and fair (without using extra cement) complete all as specified and as directed by Engr-in-charge.
M&L for 75mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub-base, finish even and rough to receive the topping layer complete all as specified and as directed by Engr-in-charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and as directed by Engr-in-charge.
Material and labour for brushing neat cement slurry with 3.0kg of cement per Sqm complete all as specified and as directed by Engr-in-charge.
Material and labour for Vitrified Ceramic tiles light shade 10 mm thick (square/rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engr-in-Charge
Material and labour for Vitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as in vertical position as dado/skirting. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engr-in-Charge
Material and labour for rendering 10mm thck in CM 1:4 as backing coat to receive tiles in vertical position as dado/skirting complete all as specified and as directed by Engr-in-charge.
Taking down cement plaster any description etc incl racking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed by Engr-in-charge.
M&L for rendering 15mm thick in cm 1:6 on fair faces of brick work or concrete surfaces of wall and finishing the surface even and smooth without using extra cement complete all as specified and as directed by Engr-in-charge.
M & L for rendering 20 mm thick in cement mortar 1:4 (15 mm thick backing coat and 5mm thick finishing coat) on fair faces of brick work or concrete surfaces including finished even and smooth without using extra cement with using water proofing compound (water proofing compound shall be measured and paid seperately) complete all as specified and as directed by Engr-in-charge.
M&L for rendering 5 mm thick in CM 1:4 on fair faces of concrete as in ceiling of slab finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-charge.
M&L for rendering 5 mm thick in cm 1:3 on fair faces of concrete as in soffit ceiling of slab, chajjas finished even & smooth without using extra cement complete all as specified and as directed by Engr-in-charge.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 mixed with water proofing compound including finished even and smooth without using extra cement complete all as specified and directed by Engr in Charge. Note: Water proofing compound will be measured and paid seperately complete all as specified and as directed by Engr-in-charge.
Material and labour for 20mm thick screed bed in CM 1:4 for laying floor finishes complete all as specified and as directed by Engr-in-charge
M&L for preparing new plastered surfaces, and applying two coats of oil bound distemper on walls over a coat of alkali resistant primer, complete all as specified and as directed by Engr-in-charge.
M&L for washing,rubbing down and stopping of distempered and painted surfaces and preparation of plastered or un-plastered old surface of wall and applying two coat of OBD over a coat of alkali resist primer on walls complete all as specified and as directed by Engr-in-charge.
M&L for Preparing new plastered surfaces of ceiling and applying two coats of white wash complete all as specified and as directed by Engr-in-charge.
M&L for preparation of new wood surfaces of any description over 10cm width of girth applying two coats of synthetic enamel paint over coat of pink primer etc complete all as specified and as directed by Engr-in-charge.
M&L for preparation of old wooden surfaces of any description over 10cm width & girth not otherwise described any one coat of synthetic enamel paint complete all as specified and as directed by Engr-in-charge.
M&L preparation of new or previously untreated surface of steel & applying two coat synthetic enamel Paint over a coat of preiming red red oxide zinc chrome complete all as specified and as directed by Engr-in-charge.
S&F for 20 mm bore medium grade GI tubing with all fittings fixed to walls and ceiling or laid in floors complete all as specified and directed. (Work includes with screwed socket joints, together with all tube fillings such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, etc. and fixing complete with clips, wall hooks, wooden plugs, or laying in trenches, etc., also for cutting, screwing and waste and for making forged bends on piping as required. Connectors shall be inserted, where required or directed. The rates also include cutting through walls, floors, etc. and their making good.) complete all as specified and as directed by Engr-in-charge.
Taking up or down steel tubing and connections of 20mm bore of pipe and removing to store as in roof /walls, etc complete all as specified and as directed by Engr-in-charge.
Labour only of taking up or down steel tubing and connections of 20mm bore of pipe including cleaning and refixing in the same position as in roof /walls, etc during carrying out of water proofing treatment without damaging to existing services, etc. complete all as specified and as directed by Engr-in-charge.
Labour only of taking up or down steel tubing and connections of 25 to 32mm bore of pipe including cleaning and refixing in the same position as in roof /walls, etc during carrying out of water proofing treatment without damaging to existing services, etc. complete all as specified and as directed by Engr-in-charge.
Labour only for disconnecting existing over head tanks of capacity exc.500 ltr and n.exc 1000 ltr, setting aside or lowering if required for repair of roof water proofing treatment and hoisting, reconnecting and re-fixing in position after necessary work without damaging to existing services etc (including tank nipple and float valve etc). all as specified and directed.
Demolition of brickwork or stone boulders masonry built in CM incl all quins, arches, pillers etc complete all as specified and as directed by Engr-in-charge.
Demolition of concrete of any description and in any position not otherwise specifically provided complete all as specified and as directed by Engr-in-charge.
Demolition of cement concrete of any description and in any position provided as in roof padding, roof curb etc complete all as specified and as directed by Engr-in-charge. Note:- (a) Demolition should be done carefully to roof slab. (b) Any damage occurred in the roof surfaces during demolition shall be made good by the contractor without extra cost to the department. (c) Disposal of debris/retrieved materials shall be thrown out of site at place complete all as specified and as directed by Engr-in-charge.
Taking down/dismantling loose/damage concrete including plaster of any description and in any position from RCC structures like chajja, fins, louvers, parapet, column, beam, and of lintel by hammering with wooden mallets carefully chipping off the old concrete surface including cutting of rusted reinforcement if so required and disposal of old debris to outside the premises complete all as specified and as directed by Engr-in-charge..
Dismantling of asbestos cement (corrugated, semicorrugated,etc sheets in roof coverings complete all as specified and as directed by Engr-in-charge.
Removing existing water proofing treatment where so ever exist (except concrete padding) and removing debris/rubbish off the site complete all as specified and as directed by Engr-in-charge.
Material and labour for water proofing treatment with APP based standard membrane over PCC padding in roof with the following courses of treatment for:- (a) Apply bituminous primer (IS 3384) @ 0.160 Kg per sqm of the surface area including cleaning the surfaces complete all as specified. (b) Apply APP plastomeric bitumen based mineral finished water proofing membrane polyester reinforced(4 Kg/Sqm) with 10cm over laps and torch bonded at joints including surface preparation before and after application of treatment as per manufactures instruction complete all as specified. (Make of APP Membrane: Moply FP 3 mm mineral of TEXA/WP Shield 103 PM of SIKA or Equivalent material of BITUNIL/BITUMAT) . (c) Over the membrane provide a solar reflective bituminous aluminium paint @ 0.1 kg/sqm prescribed by manufacturer complete all as specified.
Cleaning the existing surface of concrete and reinforcements as obtained after execution of item No. 55 here in before by wire brush including scrapping & cleaning with emery paper and washing down with water as required and applying “Solvent free epoxy concrete bonding agent” as per manufacturer’s instructions on old concrete surfaces for bonding with new concrete complete all as specified and as directed by Engr-in-charge. Note- (i) Solvant free Epoxy concrete bonding agent shall be measured and paid separately .
Supply only. Solvant free Epoxy concrete bonding agent complete all as specified and as directed by Engr-in-charge.
M&L for preparing new plastered surfaces of wall and applying two coats of acrylic weather paint exterior grade over a coat of weather coat primer complete all as specified and as directed by Engr-in-charge.
Taking down Copper/Aluminium Point Wiring (Light, Fan, Socket or Power) including Fixture and Fittings such as Switches, Ceiling Roses, Pendants, Regulators, Sockets, Light Fitting, etc. and Making Good Disturbed Surfaces of Walls, Floors, etc. so as to match with the Existing Finishes complete all as specified and as directed by Engr-in-charge.
Taking down the existing unservicable Sub-main Wiring of any type and any description as existing at Site including Making Good the Disturbed Surfaces of Walls, Floors, etc. so as to match with the Existing Finishes complete all as specified and as directed by Engr-in-charge.
Taking down the existing unserviceable Main Switch/ Cut out/ DBs of any type/ capacity and any description as existing at Site including Making Good the Disturbed Surfaces of Walls, Floors, etc. so as to match with the Existing Finishes complete all as specified and as directed by Engr-in-charge.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable drawn through and including Rigid Non- metallic PVC Conduit 25mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and making Good in Cement Mortar 1:3 mounted on 1.6mm thick Sunk Mild Steel Pressed Terminal Box of suitable size duly painted with Red Oxide Metal Primer with 3.0 mm thick Plastic Laminated Sheet Top Cover for mounting Switches, Sockets, Fan Regulators, etc. including 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable (Green Colour) as Earth Continuity Conductor connected to Common Earth dolly for ONE LIGHT/FAN POINT CONTROLLED BY ONE 1-WAY SWITCH 6 AMP, complete all as specified and as directed by Engr-in-charge.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable drawn through and including Rigid Non-metallic PVC Conduit 25mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and making Good in Cement Mortar 1:3 mounted on 1.6mm thick Sunk Mild Steel Pressed Terminal Box of suitable size duly painted with Red Oxide Metal Primer with 3.0 mm thick Plastic Laminated Sheet Top Cover for mounting Switches, Sockets, Fan Regulators, etc. including 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable (Green Colour) as Earth Continuity Conductor connected to Common Earth dolly for ONE 3 PIN SOCKET OUTLET 6 AMP ON INDEPENDENT BOARD, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable drawn through and including Rigid Non-metallic PVC Conduit 25mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and making Good in Cement Mortar 1:3 mounted on 1.6mm thick Sunk Mild Steel Pressed Terminal Box of suitable size duly painted with Red Oxide Metal Primer with 3.0 mm thick Plastic Laminated Sheet Top Cover for mounting Switches, Sockets, Fan Regulators, etc. including 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable (Green Colour) as Earth Continuity Conductor connected to Common Earth dolly for ONE 3 PIN SOCKET OUTLET 6 AMP ON THE SAME BOARD complete all as specified and as directed by Engr-in-charge.
M&L Point Wiring with 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable drawn through and including Rigid Non- metallic PVC Conduit 25mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and making Good in Cement Mortar 1:3 mounted on 1.6mm thick Sunk Mild Steel Pressed Terminal Box of suitable size duly painted with Red Oxide Metal Primer with 3.0mm thick Plastic Laminated Sheet Top Cover for mounting Switches, Sockets, Fan Regulators, etc. including 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable (Green Colour) as Earth Continuity Conductor connected to Common Earth dolly for ONE 3 PIN SOCKET 16 AMP ON INDEPENDENT BOARD complete all as specified and as directed by Engr-in-charge.
M&L Sub-main Wiring with 2-Runs of 6.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable drawn through and including Non-metalic Rigid PVC Conduit of size 25mm dia, medium grade, ISI marked and its Accessories including 1-Run of 4.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable (Green Colour) as Earth Continuty Conductor along with the Wiring in Concealed and Making Good Disturbed Surfaces of Walls/Roofs/Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed by Engr-in-charge.
S&F PVC Flexible Pipe, ISI marked, heavy duty of size 25mm with all Fittings including taking down old unserviceable one complete all as specified and as directed by Engr-in-charge.
S & F Rigid non metallic PVC conduit 25 dia (external ) ISI marked (on surface) incl of all accessories and all fittings such as Tees,bends, elbows, reducers, bell mouth, tube ends and fixing accossories such as couplers,lock nuts, saddles, pipe hook etc complete all as specified and as directed by Engr-in-charge.
S&F Switch Piano 6 Amp, Flush type, Single Pole, 1-way complete all as specified and as directed by Engr-in-charge.
S&F Switch Piano 16 Amp, Flush type, Single Pole, 1-way complete all as specified and as directed by Engr-in-charge.
S&F Socket Outlet 6 Amp, Piano, Flush type, 2-in-1, multi-purpose, 3 Pin complete all as specified and as directed by Engr-in-charge.
S&F Socket Outlet 6 Amp & 16 Amp, Piano, Flush type, 2-in-1, multi-purpose, 5 Pin complete all as specified and as directed by Engr-in-charge.
S&F Ceiling Rose, 3 Terminals, PVC Polycarbonate, Isolated body complete all as specified and as directed by Engr-in-charge.
S&F Fan Regulator in 5 Step type, Single Pole, 230 Volt, Electronic type complete all as specified and as directed by Engr-in-charge.
M & L for taking down unserviceable light fitting 10W any type any make & S & F Decorative Ultra Slim Linear LED Lighting Fixture with Extruded Polycarbonate, Environmental Friendly, Energy Efficient 5 Watt LED 6000K and connecting up with and including Copper Conductor Cable of size 23/0.0076 multi-stranded, 3 Core from Ceiling Rose to Light Fitting complete all as specified and as directed by Engr-in-charge.
M & L for taking down unserviceable light fitting 18/20 W any type S&F Decorative Ultra Slim Linear LED Lighting Fixture with Extruded Polycarbonate, Environmental Friendly, Energy Efficient 10 Watt LED 6000K and connecting up with and including Copper Conductor Cable of size 23/0.0076 multi-stranded, 3 Core from Ceiling Rose to Light Fitting complete all as specified and as directed by Engr-in-charge.
M & L for taking down unserviceable Wall light fitting 15 W any type S&F Decorative Wall light fitting made up of Polycarbonate with 0.5 W LED lamp (B-22 base) LED 6000K and connecting up with and including Copper Conductor Cable of size 23/0.0076 multi-stranded, 3 Core from Ceiling Rose to Light Fitting complete all as specified and as directed by Engr-in-charge.
M & L for taking down unserviceable light fitting 36 W any type S&F Decorative Ultra Slim Linear LED Lighting Fixture with Extruded Polycarbonate, Environmental Friendly, Energy Efficient 18Watt LED 6000K and connecting up with and including Copper Conductor Cable of size 23/0.0076 multi-stranded, 3 Core from Ceiling Rose to Light Fitting complete all as specified and as directed by Engr-in-charge.
Taking down unserviceable MCB SP 6 to 32 A and S&F MCB Single Pole, 6 to 32 Amp, 240 Volt, AC, 'B' Series for fixing on MCB DB’s, 10 kA, 50 Hz and connecting up complete all as specified and as directed by Engr-in-charge..
Taking down unserviceable MCB SPN 40 A and S&F MCB Single Pole & Neutral, 40 Amp, 240 Volt, AC, 'C' Series for fixing on MCB DB’s, 10 kA, 50 Hz and connecting up complete all as specified and as directed by Engr-in-charge..
Taking down unserviceable Sheet metal enclosure and S&F Sheet Metal Enclosure, Single Pole & Neutral with a 2-Pin and Earth Plug and Socket with 1 No. MCB Single Pole, 20 Amp, 240 Volt and connecting up complete all as specified and as directed by Engr-in-charge.
Taking down unserviceable DB 8 Way and S&F MCB DB 8-way, Single Pole & Neutral, Double Door type, Regal Grey Colour, Sheet Steel Phosphatised, Powder Coated with 200 Amp rate Bus-bar, Neutral Link Earth Bar & Din Rail duly embedded in Wall including Concealed upto Wall Surface including connecting with existing Cable Incoming and Outgoing with Cable Lugs as per the requirement and and Making Good Disturbed Surfaces of Walls/Roofs/ Floors, etc. so as to match with the existing Finishes complete all as specified and as directed by Engr-in-charge.
S&F Load Line DB 4-way Enclosure Double Door with Incomer MCCB 100 Amp rating, 25 KA, 3 Pole and suitable for 415 Volt 50 Hz AC Supply including taking down old unserviceable one complete all as specified and as directed by Engr-in-charge.
Supply and fix exhaust fan, energy efficient heavy duty 230 mm sweep, 1300 RPM enrgy efficient, with louvers, Single phase, 50 Hz with three core twisted cable of suitable size for connecting upto ceiling rose complete all as specified and as directed by Engr-in-charge..
M&L Earthing with Galvanised Steel Earth Plate Electrode 600x600x 6mm, buried directly in ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to Galvanised Earth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one complete all as specified and as directed by Engr-in-charge. Note - (a) Earth resistance to come below 1 ohms of earth pit. Work to be Complete all as specified and directed by Engineer-in-Charge. (a) On testing, If the earth resistance less than specified is not obtained, Earthing will be re-done at no extra cost. (b) If Soil Resistance test is required same shall be done by the contractor without any extra cost.
Atharva Enterprises
industrial suppliers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .