REPAIR/REPLACEMENT TO LT PANELS AND CONNECTED ITEMS AT AF STN SARSAWA UNDER GE (AF)SARSAWA
2021_MES_453289_2
8121/SAR-32/E8 REPAIR/REPLACEMENT TO LT PANELS AND
Open Tender
Civil Works
Works
333 days
GE(AF)SARSAWA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
₹60,500
Yes
25 Sept 2021
14 Aug 2021
13 Sept 2021
14 Aug 2021
11 Sept 2021
28 Aug 2021
14 Aug 2021 - 28 Aug 2021
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc for taking out/laying of U/G HT/LT cable and getting out the excavated soil including triming the sides complete all as specified and directed.
Returning, filling in, incl spreading leveling, watering and well raming in layers not exc 25 centimetre thick in layer in any type of soil complete all as specified and as directed
Removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and directed.
Materials and labour for common burnt clay bricks, sub class 'B' grade laid in trenches for protection of UG cables perpendicular to the direction of the cables complete all as specified and as directed.
Materials and labour for sand cushioning with layer of dry, clean & fine sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and as directed (Note :- Only PAN thickness shall be measured).
Supplying, laying, jointing, testing and commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 10 Sqmm 4 core conforming to IS- 7098 (Part I) 1988 as in trenches or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape including taking out old existing cable of any size and description complete all as specified and as directed.
Supplying, laying, jointing, testing and commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 16 Sqmm 4 core conforming to IS- 7098 (Part I) 1988 in trenches or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape including taking out old existing cable of any size and description complete all as specified and as directed.
Supplying, laying, jointing, testing and commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 35 Sqmm 4 core conforming to IS- 7098 (Part I) 1988 in trenches or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape including taking out old existing cable of any size and description complete all as specified and as directed.
Supplying, laying, jointing, testing and commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 50 Sqmm 4 core conforming to IS- 7098 (Part I) 1988 in trenches cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape including taking down/out of old cable as existing on site complete all as specified and as directed.
Supplying, laying, jointing, testing and commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 70 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 in trenches cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape including taking down/out of old cable as existing on site complete all as specified and as directed.
Supplying, laying, jointing, testing and commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 95 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 in trenches cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape including taking out old existing cable of any size and description complete all as specified and as directed.
Supplying, laying, jointing, testing and commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 120 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 in trenches cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape including taking out old existing cable of any size and description complete all as specified and as directed.
Supplying, laying, jointing, testing and commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 185 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 in trenches cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape including taking out old existing cable of any size and description complete all as specified and as directed.
Supplying, laying, jointing, testing and commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 240 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 in trenches cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape including taking down/out of old cable as existing on site complete all as specified and as directed.
Supplying, laying, jointing, testing and commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 300 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape including taking down/out of old cable as existing on site complete all as specified and as directed.
Supplying, laying, jointing, testing and commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 400 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 in trenches cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape including taking down/out of old cable as existing on site complete all as specified and as directed. (Note for srl No 06 to 16 :- Excavation and earth work, GI pipe, brick cover and sand cushioning or cable protection cover shall be measured and paid separately).
Labour for road cutting upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and GI tubing in soft/loose soil complete all as specified.
M&L for CSIR approved instant ready mix pothole repairing compound/mortar maunfactured with a blend of bitumen , aggregate and high grade polymer to ensure immediate bonding with existing surface. Note :- Each bag have 25 kg weight.
Supply and laying 50mm outer dia, double walled, corrugated HDPE duct pipe conforming to IS- 14930 Pt-II with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed.
Supply and laying 32mm outer dia, double walled, corrugated HDPE duct pipe conforming to IS- 14930 Pt-II with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed.
S&F in replacement of Double door three phase prewired distribution board 4 way TPN made out of CRCA sheets 1.6 mm thick, phosphatised powder coated with copper Bus Bar 200 Amps, 415 V, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and including MCCB 4 pole 63 Amp rating repturing capacity 16 KA (Note:- Single Phase MCBs are to be measured and paid for seperately) Make - Legrand, Schneider and Seimens.
S&F in replacement of single pole isolator 63 Amps complete all as specified and as directed. Make:- Legrand, Schneider and Seimens
Supply & fix in replacement of energy meter box of standared size for single phase energy meter including painting of Qtr no on each meter complete all as specified and as directed. Make Legrand,Havells,
M&L for pre polished chequred cement concrete tiles of size 300mm x 300mm x 25mm thick, parallelogram or in any shape of any tint, heavy duty , set jointed and pointed with grey cement slurry, laid over 15 mm thick bedding layer of CM 1:4 complete all as specified and as directed.
Shifting of LT ACB of capacity 400 to 1200Amps of any make and rating with in station premises after taking shutdown & disconnecting LT supply and servicing by cleaning the fix and moving parts ,removing dust particle by using high speed blower applying greese/jelly to moving mechanism and moving parts, tightening all as specified and directed by the Engr-in-charge. Note:- At new location LT ACB shall be mounted on PCC 1:2:4 type B-1 (with 20 mm graded stone aggregate) foundation block of suitable size upto 40 cm above ground level as directed. The cost of the PCC block shall be deemed to be included in the unit rate quoted for the item .
Supply, installation, testing & commissioning floor mounted LT Power distribution feeder pillars outdoor type, complying to IS 5039 standard suitable for 415V, 3 phase, 4 wire, 50 Hz, factory made out of 40 x 40 x 6 mm angle iron frame and 3.15 mm thick CRCA sheet double door type, floor mo-unting, having partially type tested assemblies as per IS 8623, IK 08 Minimum IP 54 degree of protection to be proided as per IS 12063-1987 / IEC 60529.including all accessories like lamps, push buttons, interlocks, CT, PT, Meters with RS 485 connectivity, SPD, etc as per Specification sheet. The fault level for the board shall be 50kA for 1sec. The panel shall be inline with relevant IS code, TC, TDS & SLD's. The door shall have three point locking arrangement. Special type tamperproof heavy duty built-in inter-lock with appropriate key shall be provided. . The door shall be provided with pad-locking facility also. Earthing bus bar and stud with plate to be provided both side of LT Panel.All Incomer shall be provided with a set of VIF meters , CT, ON indication lamps, phase indicating lights etc,All incommer and outgoing MCCB to be provided with Rotary operating handle.SPD as to be provided as IS 16463 : Part 12 : 2017/IEC 61643-12:2008 Low - Voltage surge protective devices: Part 12. including dismantling and taking down old existing panel complete all as specified and directed by the Engr-in-charge.
Incommer :- (a) MCCB, 400A, 4pole 36KA with adjustable thermal magnetic release with LSI protection, Ics= Icu. with rotary operating handle, auxillary switch for ON/OFF/Trip indication and both side spreder links of copper (b) .Phase indication and ON/Trip indication LED Lights.Digital VIF Meter with required CTs of 400/5A Outgoing :- (a) MCCB 320A, 4pole 36 KA with Thermal magnetic release with LSI protection. Ics= Icu =1no. (b) MCCB 250A, 4pole 36 KA with adjustable TM release with LSI Protection, Ics= Icu. 2 nos (c)MCCB 100A, 4pole 36KA with adjustable thermal magnetic release with LSI protection, Ics= Icu.= 2nos.
Supply, installation, testing & commissioning floor mounted LT Power distribution feeder pillars outdoor type, complying to IS 5039 standard suitable for 415V, 3 phase, 4 wire, 50 Hz, factory made out of 40 x 40 x 6 mm angle iron frame and 3.15 mm thick CRCA sheet double door type, floor mo-unting, having partially type tested assemblies as per IS 8623, IK 08 Minimum IP 54 degree of protection to be proided as per IS 12063-1987 / IEC 60529.including all accessories like lamps, push buttons, interlocks, CT, PT, Meters with RS 485 connectivity, SPD, etc as per Specification sheet. The fault level for the board shall be 50kA for 1sec. The panel shall be inline with relevant IS code, TC, TDS & SLD's. The door shall have three point locking arrangement. Special type tamperproof heavy duty built-in inter-lock with appropriate key shall be provided. . The door shall be provided with pad-locking facility also. Earthing bus bar and stud with plate to be provided both side of LT Panel.All Incomer shall be provided with a set of VIF meters , CT, ON indication lamps, phase indicating lights etc,All incommer and outgoing MCCB to be provided with Rotary operating handle.SPD as to be provided as IS 16463 : Part 12 : 2017/IEC 61643-12:2008 Low - Voltage surge protective devices: Part 12 including dismantling and taking down old existing panel complete all as specified and directed by the Engr-in-charge.
Incommer :- (a) MCCB, 320A, 4pole 36KAith adjustable thermal magnetic release with rotary operating handle, auxillary switch for ON/OFF/Trip indication and both side spreder links of copper (b) .Phase indication and ON/Trip indication LED Lights.Digital VIF Meter with required CTs of 320/5A Outgoing :- (a) MCCB 250A, 4pole 36KA with adjustable thermal magnetic release with LSI protection, Ics= Icu =01 No (b) MCCB 200A, 4pole 36 KA with adjustable TM release with LSI Protection, Ics= Icu. =02 Nos (C) 63A 4pole Isolators =4 Nos (d) 40A DP Isolators. = 12 Nos
Supply, installation, testing & commissioning floor mounted LT Power distribution feeder pillars outdoor type, complying to IS 5039 standard suitable for 415V, 3 phase, 4 wire, 50 Hz, factory made out of 40 x 40 x 6 mm angle iron frame and 3.15 mm thick CRCA sheet double door type, floor mo-unting, having partially type tested assemblies as per IS 8623, IK 08 Minimum IP 53 degree of protection to be proided as per IS 12063-1987 / IEC 60529.including all accessories like lamps, push buttons, interlocks, CT, PT, Meters with RS 485 connectivity, SPD, etc as per Specification sheet. The fault level for the board shall be 50kA for 1sec. The panel shall be inline with relevant IS code, TC, TDS & SLD's. The door shall have three point locking arrangement. Special type tamperproof heavy duty built-in inter-lock with appropriate key shall be provided. . The door shall be provided with pad-locking facility also. Earthing bus bar and stud with plate to be provided both side of LT Panel.All Incomer shall be provided with a set of VIF meters , CT, ON indication lamps, phase indicating lights etc,All incommer and outgoing MCCB to be provided with Rotary operating handle.SPD as to be provided as IS 16463 : Part 12 : 2017/IEC 61643-12:2008 Low - Voltage surge protective devices: Part 12 including dismantling and taking down old existing panel complete all as specified and directed by the Engr-in-charge.
Incommer :- (a) MCCB, 320A, 4pole 36KA with adjustable thermal magnetic release with rotary operating handle, auxillary switch for ON/OFF/Trip indication and both side spreder links of copper (b) .Phase indication and ON/Trip indication LED Lights.Digital VIF Meter with required CTs of 320/5A Outgoing :- (a) . MCCB 250A, 4pole 36KA with adjustable thermal magnetic release with LSI protection, Ics= Icu =01 No (b) MCCB 200A, 4pole 36 KA with adjustable TM release with LSI Protection, Ics= Icu. =02 Nos (C) 63A 4pole Isolators =7 Nos (d) 40A DP Isolators = 12 Nos
Supply, installation, testing & commissioning floor mounted LT Power distribution feeder pillars outdoor type, complying to IS 5039 standard suitable for 415V, 3 phase, 4 wire, 50 Hz, factory made out of 40 x 40 x 6 mm angle iron frame and 3.15 mm thick CRCA sheet double door type, floor mo-unting, having partially type tested assemblies as per IS 8623, IK 08 Minimum IP 54 degree of protection to be proided as per IS 12063-1987 / IEC 60529.including all accessories like lamps, push buttons, interlocks, CT, PT, Meters with RS 485 connectivity, SPD, etc as per Specification sheet. The fault level for the board shall be 50kA for 1sec. The panel shall be inline with relevant IS code, TC, TDS & SLD's. The door shall have three point locking arrangement. Special type tamperproof heavy duty built-in inter-lock with appropriate key shall be provided. . The door shall be provided with pad-locking facility also. Earthing bus bar and stud with plate to be provided both side of LT Panel.All Incomer shall be provided with a set of VIF meters , CT, ON indication lamps, phase indicating lights etc,All incommer and outgoing MCCB to be provided with Rotary operating handle.SPD as to be provided as IS 16463 : Part 12 : 2017/IEC 61643-12:2008 Low - Voltage surge protective devices: Part 12 including dismantling and taking down old existing panel complete all as specified and directed by the Engr-in-charge.
Incommer :- (a) MCCB, 100A, 4pole 25KA with adjustable thermal magnetic release with rotary operating handle, auxillary switch for ON/OFF/Trip indication and both side spreder links of copper (b) .Phase indication and ON/Trip indication LED Lights.Digital VIF Meter with required CTs of 320/5A Outgoing :- (a) . MCCB 63A, 4pole 25KA with adjustable thermal magnetic release with LSI protection, Ics= Icu.=02 Nos
Supply, installation, testing & commissioning floor mounted LT Power distribution feeder pillars outdoor type, complying to IS 5039 standard suitable for 415V, 3 phase, 4 wire, 50 Hz, factory made out of 40 x 40 x 6 mm angle iron frame and 3.15 mm thick CRCA sheet double door type, floor mo-unting, having partially type tested assemblies as per IS 8623, IK 08 Minimum IP 54 degree of protection to be proided as per IS 12063-1987 / IEC 60529.including all accessories like lamps, push buttons, interlocks, CT, PT, Meters with RS 485 connectivity, SPD, etc as per Specification sheet. The fault level for the board shall be 50kA for 1sec. The panel shall be inline with relevant IS code, TC, TDS & SLD's. The door shall have three point locking arrangement. Special type tamperproof heavy duty built-in inter-lock with appropriate key shall be provided. . The door shall be provided with pad-locking facility also. Earthing bus bar and stud with plate to be provided both side of LT Panel.All Incomer shall be provided with a set of VIF meters , CT, ON indication lamps, phase indicating lights etc,All incommer and outgoing MCCB to be provided with Rotary operating handle.SPD as to be provided as IS 16463 : Part 12 : 2017/IEC 61643-12:2008 Low - Voltage surge protective devices: Part 12 including dismantling and taking down old existing panel complete all as specified and directed by the Engr-in-charge.
Incommer :- (a) MCCB, 200A, 4pole 36KA with adjustable thermal magnetic release with rotary operating handle, auxillary switch for ON/OFF/Trip indication and both side spreder links of copper (b) .Phase indication and ON/Trip indication LED Lights.Digital VIF Meter with required CTs of 320/5A Outgoing :- (a) . MCCB 100A, 4pole 36KA with adjustable thermal magnetic release with LSI protection, Ics= Icu. = 02 Nos (b) . MCCB 63A, 4pole 25KA with adjustable thermal magnetic release with LSI protection, Ics= Icu.=02 Nos
Supply, installation, testing and commissioning of LT Power distribution panels indoor type, complying to IEC61439-1/2 suitable for 415V, 3 phase, 4 wire, 50 Hz, Single front, floor mounting type, extensible with bolted design having 9 fold structure and totally type tested assemblies, IP : 42 enclosure having IK09, with all accessories including dismantling and taking down old existing panel complete all as specified and directed by the Engr-in-charge. Incommer :- (a) MCCB, 250A, 4pole 36KA with adjustable thermal magnetic release with rotary operating handle, auxillary switch for ON/OFF/Trip indication and both side spreder links of copper (b) .Phase indication and ON/Trip indication LED Lights.Digital VIF Meter with required CTs of 250/5A Outgoing :- (a) MCCB 200A, 4pole 36KA with adjustable thermal magnetic release with LSI protection.=01 Nos (b) MCCB 125A, 4pole 36KA with adjustable thermal magnetic release with LSI protection.=02 Nos (c)MCCB 100A, 4pole 36KA with adjustable thermal magnetic release with LSI protection.=02 Nos (d) MCCB 63A, 4pole 36KA with adjustable thermal magnetic release with LSI protection.=01 Nos
Supply, installation, testing and commissioning of LT Power distribution panels indoor type, complying to IEC61439-1/2 suitable for 415V, 3 phase, 4 wire, 50 Hz, Single front, floor mounting type, extensible with bolted design having 9 fold structure and totally type tested assemblies, IP : 42 enclosure having IK09, with all accessories,all as specified and directed by the Engr-in-charge. (FOR 117 HU DG supply) Incommer :- (a) MCCB, 250A, 4pole 36KA with adjustable thermal magnetic release with rotary operating handle, auxillary switch for ON/OFF/Trip indication and both side spreder links of copper (b) .Phase indication and ON/Trip indication LED Lights.Digital VIF Meter with required CTs of 400/5A Outgoing :- (a) MCCB,200A, 4pole 36KA with adjustable thermal magnetic release with LSI protection.=02 Nos (b) MCCB 125A, 4pole 36KA with adjustable thermal magnetic release with LSI protection.=02 Nos
Supply, installation, testing and commissioning of LT Power distribution panels indoor type, complying to IEC61439-1/2 suitable for 415V, 3 phase, 4 wire, 50 Hz, Single front, floor mounting type, extensible with bolted design having 9 fold structure and totally type tested assemblies, IP : 42 enclosure having IK09, with all accessories,all as specified and directed by the Engr-in-charge. (FOR coo office ) Incommer :- (a) MCCB, 125A, 4pole 36KA with adjustable thermal magnetic release with rotary operating handle, auxillary switch for ON/OFF/Trip indication and both side spreder links of copper (b) .Phase indication and ON/Trip indication LED Lights.Digital VIF Meter with required CTs of 400/5A Outgoing :- (a) MCCB,100A, 4pole 36KA with adjustable thermal magnetic release with LSI protection.=02 Nos (b) MCCB 63A, 4pole 36KA with adjustable thermal magnetic release with LSI protection.=01 Nos (c)63A, 4pole Isolator=01 Nos
Supply, installation, testing and commissioning of LT Power distribution panels indoor type, complying to IEC61439-1/2 suitable for 415V, 3 phase, 4 wire, 50 Hz, Single front, floor mounting type, extensible with bolted design having 9 fold structure and totally type tested assemblies, IP : 42 enclosure having IK09, with all accessories,all as specified and directed by the Engr-in-charge. (FOR CDAF HUT ) Incommer :- (a) MCCB, 250A, 4pole 36KA with adjustable thermal magnetic release with rotary operating handle, auxillary switch for ON/OFF/Trip indication and both side spreder links of copper (b) .Phase indication and ON/Trip indication LED Lights.Digital VIF Meter with required CTs of 400/5A Outgoing :- (a) MCCB,200A, 4pole 36KA with adjustable thermal magnetic release with LSI protection.=02 Nos (b) MCCB 63A, 4pole 36KA with adjustable thermal magnetic release with LSI protection.=02 Nos
Note for item srl No 27 to 35:- (i) Make:- Legrand/L&T/Schneider (ii) The switchgear & enclosure should be same make. (iii) Quoted rates are inclusive of cost of cable glands at entry & exist of each cable, cable thimble/lugs and painting of feeder identification mark on each feeder. (iv) Panel is to placed on angle iron frma made out of 50 x 50 x 6 mm angle duly provided with four legs 750 mm long (eaach) out of which 300 mm to be grounted in PCC 1:2:4 balance length of 450 mm above ground to be covered with detachable FI sheet 3 mm thick on the all sides except front side, duly painted two coats of paint over a coat of red oxide primer on exposed surface. (v) GA drawing to be approved from Engr-in-Charge & GE prior to fabrication. (vi) All panel should be powder coating with 9 tank. (vii) AI 4 pole bush bar of suitable rating with heat shrinkable sleeve with colour coding.
G.H. INFRASTRUCTURE PRIVATE LIMITED
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .