Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹36.4 LAccepted-AOC NOT AVAILABLE | NEW DELHI | DELHI | 110001 | 1 | Accepted-AOC ACCEPTED BEING THE LOWEST TENDERER | |
| 2 | 2₹37.8 L+₹1.4 L (3.80%)Rejected-Finance | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 3 | 3₹38.4 L+₹2.0 L (5.58%)Rejected-Finance | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 4 | 4₹46.7 L+₹10.3 L (28.2%)Rejected-Finance | 4 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
17 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF JORHAT
HQ CWE AF JORHAT, ROWRIAH, JORHAT, ASSAM-785005
84081/E8 ADDN/ ALTN TO HT/LT CABLES AT CERTAIN LOCATIONS AT AF STATION UNDER GE AF JORHAT
2024_MES_675523_1
84081/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF JORHAT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF JORHAT
₹90,000
Yes
18 Nov 2024
20 Sept 2024
18 Oct 2024
20 Sept 2024
17 Oct 2024
5 Oct 2024
Amount
Surface Dressing not exc. 15 Cm deep around Transformer/ 2 Pole/ 4 Pole Structures or Sub-station Switch Yard, etc. and getting out in Soft/ Loose Soil including Removing Grass, Roots, Vegetations', etc. to a Distance not exc. 100.00 Metre and deposited, complete all as specified and as directed.
M&L Excavation and Transporting of Approved Earth from Outside of MD/ AF Land and Forming Embankments including Raising Earth, Spreading in Layers not exc. 30 Cm thick; Watering, Ramming/ Rolling and Finishing to required Size, Shape, etc., not exc. 1.50 Metre High from Base, complete all as specified and as directed. NOTE : Quoted Unit Rate is inclusive of Excavation, Transporting of Approved Earth from Outside of MD/ AF Land to Site of Work including Payment of Royality if any. Noting Extra shall be admissible in this account.
M&L Hardcore with Broken Stone or Boulders of Gauge exc. 63mm but not exc. 100mm, Deposited, Spread and Leveled in Layers not exc. 15 Cm thick, Watered and Rolled/ Rammed to a True Surface, complete all as specified and as directed.
M&L Cement Concrete 1:4:8 (40mm graded stone aggregates) in Foundation Filling, Mass Concrete, etc. around Transformer/ 2 Pole/ 4 Pole Structures or Sub-station Switch Yard, etc. including Use & Waste of Formwork as required/ ordered, complete all as specified and as directed. NOTE : Cost of Formwork will deem to include in the Quoted Unit Rate.
Excavating in Trenches not exc. 1.50 Metre Wide and not exc. 1.50 Metre in Depth for Taking Out/ Laying of UG Electric Cable Lines, etc., Forming Surfaces to required Foundation and getting out in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in including Spreading, Leveling, Watering, Well Ramming in Layers not exc. 25 Cm, Providing Heaps not exc. 150mm Height along the UG Electric Cable Lines/ Route, etc. for future Settling down with Surplus Soil, complete all as specified and as directed.
Horizontal Boring below/ under Hardstanding, Pavements, Roads, etc. for Crossing/ Passing Pipe upto 80mm bore (dia) in Soft/ Loose Soils, complete all as specified and as directed. NOTE : GI Protection Pipe will be Measured & Paid separately under appropriate Items.
Taking down/ out Unserviceable or Serviceable UG Cables of any Cross Sectional Area after disconnections, Cables laid in Trenches and/ or Fixing with Walls/ Poles including Segregating of Serviceable Materials viz Bricks, etc. and kept in Safe Custody for re-use, complete all as specified and as directed. NOTE : Earth Work will be Measured and Paid separately under relevant Items.
Supply, Laying & Testing XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt Grade, Cross-sectional Area 185 Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Walls, Poles, etc., complete all as specified and as directed. NOTE :- (a) Cost of Saddle and Clamp for Fixing of Cable on Walls shall deem to be included in the Quoted Unit Rate. (b) Necessary Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be Measured and Paid separately under relevant Items.
Supply, Laying & Testing UG XLPE insulated, Screened, PVC Bedded, Galvanised Steel Strip or Wire Armoured, Electric Power Cables (Heavy duty) with Aluminium Conductor, 11000 Volts Grade (Earthed), Cross sectional Area 95 Sqmm, 3 Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Walls, Poles, etc. including jointing with suitable Size Aluminium Lugs, complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be Measured and Paid separately under relevant Items.
M&L Cable Jointing Kit for 1100 Volt Grade Cable, Straight Through type complete with Jointing Materials and Accessories suitable for XLPE Armoured Aluminium Conductor Cable, Cross sectional Area 120 Sqmm to 185 Sqmm, 3½/ 4 Core, Providing Connection and Testing, complete all as specified and as directed.
M&L Cable Jointing Kit for 11 KV (Earthed) Grade Cable, Outdoor Termination, Heat Shrink type complete with Jointing Materials and Accessories suitable for XLPE Armoured Aluminium Conductor Cable, Cross sectional Area 95 Sqmm, 3 Core, Providing Connection and Testing, complete all as specified and as directed.
M&L Cable Jointing Kit for 11 KV (Earthed) Grade Cable, Straight Through, Heat Shrink type complete with Jointing Materials and Accessories suitable for XLPE Armoured Aluminium Conductor Cable, Cross sectional Area 50 Sqmm to 95 Sqmm, 3 Core, Providing Connection and Testing, complete all as specified and as directed.
M&L Sand Cushioning (Dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 230mm Spread thickness (80mm in Depth before Laying the Cable and 150mm in Depth after Laying the Cable) and Consolidated (Punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be Measured.
Supply & Laying Sub-class ‘B’ Bricks of Size 230x115x75mm, Kiln burnt, for Covering to UG Cable as Protection, laid Flat, Transversally Width Equal to the Length of the Cable, complete all as specified and as directed.
Laying Only Sub-class ‘B’ Bricks (Serviceable Bricks obtained from Sl (Item) No. 8 here-in-before) for Covering to UG Cable as Protection, laid Flat, Transversally Width Equal to the Length of the Cable, complete all as specified and as directed.
S&F Galvanised Steel Tubing 80mm bore (dia), Light grade, Conforming to IS-1239 with all Fittings for Protection of UG Cable, laid in Trenches, etc., complete all as specified and as directed. NOTE : Necessary Earth Works will be Measured & Paid separately under appropriate Items.
S&F Cable Route Indicator (Marker), made out of GI Sheet 2.0mm thick, Circular in Shape not exc. 150mm in Dia, Welded with GI Rod __mm Dia, buried 30 Cm below the GL including Plain Cement Concrete 1:2:4 (20mm graded stone aggregates) Copping upto GL along the UG Cable Trench Approx 30.00 Meter Distance between Two Cable Route Indicator (Marker) including Writing Letters, Figures, viz "UG LT MES" or "UG HT MES" with White Paint and Necessary Earth Works as per Site requirments, complete all as specified and as directed. NOTE : Cost of Earth Work, PCC, Formwork, Painting Work, etc. will deem to be include in the Quoted Unit Rate.
Supply, Installation, Testing & Commissioning Factory Made (CPRI Approved/ Tested Manufacturer) HT Outdoor Feeder Pillar Box, suitable for 11000 Volt, 3 Phase, 50 Hz 630 Amps, AC system of suitable Size, Totally Enclosed, Self Supporting Bottom Structure/ Cubicle, Weather & Vermin Proof, IP-66 Protected, with Cable Entry, Structure made out of 3.15mm thick CRCA Steel Sheets with Angle Iron Frame Work and Legs 600mm above Normal Ground Level, made of Mild Steel ISA 75x75x6.0mm with Four Legs grouted to Plain Cement Concrete 1:2:4 (20mm graded aggregates) Foundation Block of adequate Size with suitable Mounting Arrangement for Aluminium Bus-bar, 100m x 10mm Size for 3 Phase supported with suitable Size Height Strength SMC/ DMC Material Insulator and suitable Size Brass Nuts, Bolts and Washers with Heat Shrinkable PVC Sleeving, with Sloping Canopy at Top, Double Hinged Doors at Front and Rear with Neoprene Rubber Gasket, suitable Locking Arrangement and bolted Shutters, Provisions of Louvers at Sides, Danger Plates, Earthing Strip Point and Bottom Detachable Gland Plate complete with Zinc/ Chromium Plated Nuts, Bolts and Washers etc, Structure Treated under 8 Tank Metal Treatment Process and duly Powder Coated including all Necessary Earth Works including Taking down Unserviceable Feeder Pillar Box after Disconnecting all Electrical Connections, complete all as specified and as directed.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick buried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, Connected with and including Galvanised Earth Strip of Size 32x6.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) ‘Light’ grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregates) and Pre-cast RCC 1:2:4 (20mm graded stone aggregates) Cover Slab of Size 450x450x50mm, Reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) ‘Medium’ grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/ out Unserviceable Earthing of any description, complete all as per specified and as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
LESS SCHEDULE OF CREDIT Bidders shall Quote the EQUAL AMOUNT (as perSCHEDULE OF CREDIT catered in TENDER DOCUMENTS) under Column 'UNIT RATE (M)' against ROW No. 33.
M/S SANTOSHI TRADERS (BID ID -3134793)
M/S PS ENTERPRISE (BID ID -3134837)
SURAJ KUMAR SHARMA (BID ID -3134940)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .