Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 LAccepted-AOC 10 A FRIENDS COLONY PATIALA 147001 | PATIALA | PUNJAB | 147001 | L1 | Accepted-AOC Responsive |
Tender Value
₹5.0 L
EMD Value
₹10,200
Closing Date
8 Dec 2020, 5:00 pmClosed
Executive Engineer
EE WSS DIVN. No. 1 Amritsar
Providing improved access to water through household connections in existing water supply village Jasraur Block Chogawan and District Amritsar under PRWSSIP 2a ii
2020_WB_53572_1
Jasraur letter No. 3831 Dated 14-09-2020
Open Tender
Civil Works
Item Wise
90 days
Amritsar
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
TIA
₹10,200
20 May 2021
17 Sept 2020
9 Dec 2020
17 Sept 2020
8 Dec 2020
17 Sept 2020
Amount
Cost of Repair of Machinery Providing & Installing Testing & Commissioning of One No. Electrically driven Submersible Pumping set of reputed Make capable of deliveringagainst a head (reputed make) complete in all respects including Cable (4.00mm2=100mtrs) as per standard Specifications.
Cost of Repair of Control Panel consisting of electric appliances such as automatic Star Delta Push Button or oil immersed Starter, Main Switch, VM, Ampere Meter, ELCB, Shunt Capacitor, Single Phase preventer, Indicating Lamps, Kit-Kat etc. (reputed make) complete in all respects as per standard Specifications.
REPAIR OF PUMP CHAMBER
Supplying & fixing glass panes with glazing clips and including special metal sash putty of approved make.
Repair of Plaster inside and outside the pump chamber complete in all respects
S.V. Repair 6" dia Complete in all respects
Hollock wood cup board shutter with plywood panels or faced on both side fixed in position (excluding the cost of handles, bolts hasp with staple but including the labour for fixing them) (a) 30mm thick Cup Board
Repair of pump chamber plinth protection complete in all respects
RECESSED CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES: Wiring in PVC insulated copper conductor single core FRLS cable (ISI marked), 1100volts grade to be laid in heavy gauge PVC, fire retardant conduit pipe 20 mm/25 mm dia, ISI marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for having electronic fan regulators (socket size), bell push, electronic buzzer, 3pin 6Amp., 3pin 16/20 Amp. Sockets and 6 Amp./16/20Amp. Swithces (flush piano type accessories) etc.and covered with brown bakelite white glazed translucent backside painted sheet 3mm thick etc., & including the cost of flush piano type switches/sockets, step type electronic fan regulator 100 watts, PVC connector (For Fan Box andElectronic Buzzer), PVC Bush, Steel Hooks, Circular Inspection Box (Recessed Type and Deep Type) conduit pipe & copper wire and other petty material etc. including the cost of cutting and filling up of wiring in PVC insulated copper conductor single core FR acble (ISI Marked), 1100 volts grade to be laid in heavy gauge, PVC, fire retardant conduit pipe 20 mm/25 mm dia, ISI marked recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for having electronic fan regulators (socket size), bell push, electronic buzzer, 3pin 6Amp., 3pin 16/20 Amp. Sockets and 6 Amp./16/20Amp. Swithces (flush piano type accessories) etc.and covered with brown bakelite white glazed translucent backside painted sheet 3mm thick etc., & including the cost of flush piano type switches/sockets, step type electronic fan regulator 100 watts, PVC connector (For Fan Box andElectronic Buzzer), PVC Bush, Steel Hooks, Circular Inspection Box (Recessed Type and Deep Type) conduit pipe & copper wire and other petty material etc. including the cost of cutting and filling up of chases:-
Wiring fan point without fan box in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100volts grade with step type electronic fan regulator 100watts (socket size).
Wiring light point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100volts grade. ( as per ac slip no. 3 on CSR Amendments)
Wiring 3 Pin 6 Amp. Plug control comprising wall socket and switch including bonding to existing earth with PVC insulated copper conductor single core FR cable (ISI marked) overall 1 sq. mm, 1100volts grade complete. ( as per ac slip no. 3 on CSR Amendments)
Wiring 3 pin 16/20 amp. power plug control and switch.
Providing and fixing of ceiling fan of reputed make such as Crompton or equivalent
Providing and fixing of electric tube set of reputed make
REPAIR OF OHSR 100000 LTR CAPACITY
Repair of Sluice Valves Complete in all respects
150mm dia Sluice Valve
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge) 100mm dia
Repair of Expansion joint at 6th Brace including shuttering & Centering Complete in all respects.
150mm dia
Supplying,fixing and testing at site Automatic electronic type water level indication system with gun metal float sensor and electrical cable suitable for three phase pump submersible / monoblock to be fixed on existing panel for OHSRs complete in all respects.
OHSR Jaali Complete in all respects
Providing & Fixing OHSR Manhole Cover Complete in all respects
REPAIR OF DEVELOPMENT OF WATER WORKS
Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing.
Providing & Fixing D hook complete with MS bolt size 300 mm x18 mm as per standard drawing D-7 & Analysis of Rates A-9 complete in all respects.
Providing & Fixing PCC Fencing Poles with 6' height 3"x3" Top & 4"x3" Base provided with 3 Nos. hooks complete in all respects
Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard Drawing D-3.
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge)
Sluice Valve Repair 6" dia Complete in all respects
Sluice Valve Haudi Repair Minor
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department With each of Size 0.9m x 0.9m complete in all respects
Footpath Top Concrete Slab & Brick Repair only Complete in all respects
Sign Board Painting & Writing Complete in all respects
Providing & Installing Testing & Commissioning of One No. Electrically driven diaphragm opreated metering system chemical dosing chlorinator suitable for for delivering 0.5 to 6 liters of Bleaching Powder solution/ Sodium Hypo solution per hour under maximum delivery pressure upto 7 Kg/cm2 and suction left not less than 1.5 mtr., as per DWSS standard specifations.
Providing and fixing in position CI Bib Cock(tap)(15 mm i/d)as per IS:210 with stainless steel spindle of approved make and Fixng of Nozzle to control flow of water(to the approval of Enginer-in-charge Complete in all respect
Providing proposed water connections to household up to wall with providing ,laying, jointing, fixing, testing MDPE pipe line 15 mm i/d = 2.00 mtr(Below GL) and ISI Marked G.I. Pipe 15 mm i/d (As per IS 1239) B-Class approved make = 2.50 mtr (Above GL) including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground and ISI marked 15 mm i/d GM Ferrule as per IS:2692 and 3" i/d clamp with CI Bib Cock 15 mm i/d as per IS:210 with stainless steel spindle of approved make as per CSR 30.65(b) complete in all respects. (Connection at Existing pipe line) = 283
CONDITIONS :-
Item for which no rate or price has been entered in will not be paid for the Employer when execut6ed and shall be deemed covered by the other rates and prices in the Bill of Quantities.
Unit rates and prices shall be quated by the bidder in indian ruppees.
Where there is a discrepancy between the rate in figures and words, the rates in words will govern.
Where there is a discrepancy between the rate and the line total resulting from muluplying the unit rate by quantity the unit rate quoted shall govern.
Any item of work not included in the above contract schedule of rates and got done at the site of work; the same will be paid according to CSR-2010 subject to the premium or discount tendered by the contractor. In the case of non-schedule items, the decision of the Engineer-in-charge will be final and binding upon the contractor. In case any item which is a part of lump-sum rate is be deducted @CSR rates + Ceiling premium prevailing on the date of tender
The work will be carried out in accordance with PWD Book of specifications - 1963 edition with upto date amendments.
Approximate quantities are given in the contract schedule of rates and these can vary at the time of execution of the work. The payment will be made according to the actual work done by the contractor.
All amendments issued on the common schedule of rates 2010. up to the date of opening of tenders will be applicable on the contract schedule of rates.
Contractor should clearly quote his rates in figures & words. Conditional tender will be rejected.
All items and rates provided in the DNIT are subject to the footnotes give in CSR-2010
The Engineer-in-charge will have full powers to change the layout of the work covered in this contract if considered necessary.
No claim will be entertained form the contractor in case, any mistake in description rates or unit occurs in any item taken in this schedule while preparing this DNIT or on account of typing or comparison or over writing. The same will be rectified at any time as per common schedule of rates 2010 along with upto date amendments.
The arrangements of bricks at site of work would be done by the contractor at his own level from his own source.
For any other non-schedule items, the contractor will submit through Engineer-in-charge, the analysis of rates in triplicate based on purchased vouchers. A margin of 10% shall be allowed for material components and 21.5% on labour components and contractor shall produce photo stat copies of the purchase vouchers in support of his claim. The decision of the Engineer-in-charge/Competent authority in the matter shall be final and binding on the contractor.
All the extra items will be got approved from the competent authority and no premium will be allowed on non schedule item
Pavement for the carriage of material shall be paid as per the rates quoted by the tenderer.
Time period allowed for completion of work in 3 months.
If contractor allowed for completion of work within 7 days from the date of allotment, DWSS reserve the right to impose penalty or withdraw the work and propose action for debarring in future tendering or both; decision of Chief Engineer (North) shall be binding.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .