Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.1 LAccepted-AOC NO 51 TOWN HALL 3RD STREET ARAKKONAM TAMIL NADU 631 001 | ARAKKONAM | RANIPET | TAMIL NADU | 631001 | L1 | Accepted-AOC ACCEPTED BEING L1 | |
| 2 | L2₹26.4 L+₹6.1 L (30.3%)Rejected-AOC D 3 7TH BLOCK JAIN GREEN ACRES DHARGA ROAD ZAMIN PALLAVARAM CHENNAI 600 043 | CHENNAI | CHENNAI | TAMIL NADU | 600043 | L2 | Rejected-AOC REJECTED DUE TO NOT BEING L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical Rejected due to No appropriate category |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
22 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer M NAS Arakkonam
Garrison Engineer M NAS Arakkonam 631006
REPAIR MAINTENANCE TO HEPA FILTERS MICRON FILTERS DISTRIBUTION BOXES MCCBS STARTERS CONTACTORS EARTHINGS AND CONNECTED ITEMS IN EM INSTALLATIONS AT INS RAJALI ARAKKONAM
2024_MES_639088_1
8341E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer M NAS Arakkonam
As per NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer M NAS Arakkonam
₹54,000
Yes
13 Mar 2024
25 Jan 2024
24 Feb 2024
25 Jan 2024
22 Feb 2024
8 Feb 2024
Amount
Material and labour for servicing and cleaning of condenser coil unit and cooling Coil unit by cleaning chemical and flushing with plain water by pressure pump for removing complete trace of soda from the coil and fix in original position including testing all as specified and directed for the following capacity. (Note: Servicing and cleaning shall be done once in 6 month)
5.5 TR Capacity
8.5 TR Capacity
11.0 TR Capacity
17 TR Capacity
22 TR Capacity
Material and labour for servicing and cleaning of AHU and Duct unit (supply air and return air) ,removing, any obstruction for AIR flow by air blower etc, and taking out all un wanted materials including cleaning Micro filter all as specified and directed by Engineer-in-Charge for the following capacity. (Note: Servicing and cleaning shall be done once in 6 month and rate includes supply and fix necessary glands)
5.5 TR Capacity
8.5 TR Capacity
11.0 TR Capacity
17 TR Capacity
22 TR Capacity
Supply & Replace washable Air filter of 5 Microns for the following size suitable for ductable package type AC plants all as specified & directed by Engineer-in-charge Note: rate includes supply and fix necessary cable glands
Air filter of size 1.8" x 1.8"(at 561 )
Air filter of size 1.6" x 1.10" (at Comcern Area,)
Air filter of size 2.5" x 1.6" (at Logistic Section)
Air filter of size 2' x 2' ( at Ops Area, ATC Tower, ATH Ist floor,Area)
Air filter of size 1.6" x 7' (at WTS, SE Section,RAQ )
Air filter of size 1' x 4' (at Magazine Telephone Exchange ,BLD )
Material & Labour for Descaling the shell and tube Condenser by circulating descaling chemical with water through condenser coil, cooling tower re-circulating pump set up to 2 to 3 hours and open the end cover of condenser and manually cleaned the inner tubes with nylon brush until complete scale to be removed and flush out with fresh water. Reconnecting the condenser end cover by replacing rubber gasket, bolts, nuts and including cleaning of cooling tower,make up water tank etc as required commissioning in all respect for the followings:- (Note: 1. Ph value of recirculating mixture of water with descale chemical should be 1 2. Descaling shall be done once in 6 month)
50 TR Capacity at Engine Holding Bay.
45 TR Capacity at Auditorium.
110 TR Capacity at Sonabouy.
38 TR Capacity at MK 54.
25 TR Capacity at Magazine A.
All as per item No. 4 here in before but Chiller of following capacity.
50 TR Capacity at Engine Holding Bay.
45 TR Capacity at Auditorium.
110 TR Capacity at Sonabouy.
38 TR Capacity at MK 54.
25 TR Capacity at Magazine A.
Material & Labour for dismantling unserviceable / worntout "V" belts any type / model , supply and fix new "V" Belt of following specification and testing . Make :- FENNER / V GRIP
V- Belt of size C-127
V- Belt of size C-122
V- Belt of size B-93
V- Belt of size B-74
V- Belt of size A-82
V- Belt of size A-57
V- Belt of size A-36
V- Belt of size A-32
V- Belt of size A-30
V- Belt of size A-26
Material & Labour for taking down unserviceable electrical Contactors / Relays /Starter / Disconnectors/ Fuse unit/ Neon Indicator Lamps, any type /capacity / model from electrical control panels including supply and fix of following specifications all as specified and as directed :-
Contactor set for 3 Pole with 1NO+1NC, 415 V of capacity AC3, 140 Amps as existing . Make BCH/ L&T /Siemens.
Contactor set for 3 Pole with 1NO+1NC, 415 V of capacity AC3, 110 Amps as existing . Make BCH/ L&T /Siemens.
Contactor set for 3 Pole with 1NO+1NC, 415 V of capacity AC3 ,70 Amps as existing. Make: BCH/ L&T /Siemens.
Contactor set for 3 Pole with 1NO+1NC, 415 V of capacity AC3, 63 Amps as existing. Make: BCH/ L&T /Siemens.
Contactor set for 3 Pole with 1NO+1NC, 415 V of capacity AC3, 32 Amps as existing. Make: BCH/ L&T /Siemens.
Contactor set for 3 Pole with 1NO+1NC, 415 V of capacity AC3, 25 Amps as existing. Make: BCH/ L&T /Siemens.
Contactor set for 3 Pole with 1NO+1NC, 415 V of capacity AC3, 18 Amps as existing . Make: BCH/ L&T /Siemens.
Over load relay (direct mounting) of Range 12-18 Amps Make: BCH, Cat Part No MC305ANA3L or equiva of L&T/Siemens.
Over load relay (direct mounting) of Range 25-32 Amps Make: BCH, Cat Part No MC305ANA3L or equiva of L&T/Siemens.
Over load relay (direct mounting) of Range 40-63 Amps Make: BCH, Cat Part No MC305ANA3L or equiva of L&T/Siemens.
DOL Starter of capacity 15 HP Make: BCH/ L&T /Siemens.
DOL Starter of capacity 12 HP Make: BCH/ L&T /Siemens.
DOL Starter of capacity 10 HP Make: BCH/ L&T /Siemens.
DOL Starter of capacity 7.5 HP Make: BCH/ L&T /Siemens.
DOL Starter of capacity 5 HP Make: BCH/ L&T /Siemens.
DOL Starter of capacity 3 HP Make: BCH/ L&T /Siemens.
Single phase preventer 415 V,3Ph. Make : Minilec, Model : VSP-3 415 Volt AC, 3 Phase, 50 Hz/L&T/Siemens.
Neon Indicator Lamp Make: L&T/ Legrand/ ABB
Supply and fix new MCCB, adjustable thermal magnetic type of following capacity/specification ,415V, 50 Hz, with extended terminal & spreader link including taking down the existing unserviceable MCCB from the panel Make : Legrand / L&T/ Siemens/ ABB/ Schneider
MCCB 4 pole, 25 KA 32 Amp
MCCB 4 pole, 25 KA 63 Amp
MCCB 4 pole, 25 KA 100 Amp
MCCB 4 pole, 25 KA 125 Amp
MCCB 4 pole, 36 KA, 160Amp
MCCB 4 pole, 36 KA, 200 Amp
MCCB 4 pole, 36 KA, 250 Amp
MCCB 4 pole, 36 KA, 320 Amp
MCCB 4 pole, 36 KA, 400 Amp
Taking up existing old/ unserviceable/ burnt cable laid on the ground/ laid on wall/ laid on cable tray from the existing positions/ trenches etc including testing with the help of megger, disconnecting and removing unserviceable portion of cable complete all as specified and as directed. Make: Polycab/ Havells/ Finolex/ KEI Note: Rates includes supply and fix necessary Glands
120 sqmm 3.5 core
95 sqmm 3.5 core
50 sqmm 3.5 core
25 sqmm 4 core
16 sqmm 4 core
M&L for cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded Aluminium conductor of following sizes
120 sqmm 3.5 core
95 sqmm 3.5 core
50 sqmm 3.5 core
25 sqmm 4 core
16 sqmm 4 core
Supply and Replace Ammeter digital type (Three digit)with suitable CTs 5A Class I as per L&T Cat Part No WDS 301FCA00 or equivalent to Siemens /ABB /AE /Meco
M&L Aluminium Lugs suitable for wire of following below size
Lugs suitable for wire upto 16 Sqmm
Lugs suitable for wire 25 Sq mm
Lugs suitable for wire 50 Sq mm
Lugs suitable for wire 70 Sq mm
Lugs suitable for wire 95 Sq mm
M&L Single core PVC insulated (unsheathed) multi strand flexible Copper conductor FRLS cable of following below size 1100Volts grade Make: Polycab/ Finolex/Plaza
Single core 16 sq mm
Single core 10 sq mm
Single core 6 sq mm
Single core 4 sq mm
M&L Copper Lugs suitable for wire of following below size
Single core 16 sq mm
Single core 10 sq mm
Single core 6 sq mm
Single core 4 sq mm
M&L for Earthing complete with using galvanised steel earth plate electrode of size 600mm x 600mm x 6 mm thick buried directly underground vertically (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate at a depth not less than 1.5m below ground level connected with and incl Galvanised iron strip 32 x 6 mm including 40 mm dia GI pipe light grade by means of nuts bolts, washers and necessary earth work in any type of soil PCC (1:3:6) type C1 chamber and RCC(1:2:4) type B-1cover with handle and watering pipe 20 mm dia medium grade with funnel complete with mesh , refiling with black cotton soil, alternate 5 layers of charcoal & salt crystal all as specified. Note:(i) Quoted rate deemend to include necessary earth work PCC chamber, RCC cover, reinforcement removal of surplus soil , site clearance etc. (ii) GI earth strip , GI tubing light grade upto 7.5m deemed to be included the rate quoted by the contractor.(iii) Beyond 7.5 M the GI earth strip & GI pipe light grade 40 mm dia shall be measured and paid separetely under the respective item of the schedule (iv) Quotated rate include testing after completion from test point and the desired earth resistance shall be not more than 5 ohm .If the desired result is not obtained the earthing will be re done by the contractor at no extra cost.
S&F Galvanised iron strip 32 x 6 mm including 40 mm dia GI pipe medium grade for protection of GI Strip
M&L for dismantling and removing the unserviceable thrust bearings from the Air handling Units of the Package/ Central type A/C plants and repalcing with new Thrust bearing of same type / model, assembling back, reinstalling, connecting and testing all as specified and as directed, Make:SKF/NBC.
S&F Filter Drier/Strainer suitable for Package AC for the following size liquid line including taking down old unserviceable one all as directed. Make; Danfoss / Emersion
Liquid line of size 3/8 "
Liquid line of size 1/2 "
Liquid line of size 5/8 "
S&F Expansion Valve suitable for the following capacity Package AC unit including taking down old unserviceable one all as directed. Make; Danfoss / Emersion
5.5 TR Capacity
8.5 TR Capacity
11 TR Capacity
17 TR Capacity
22 TR Capacity
M&L for Servicing of following Air Handling Units ( AHU's ) with humidification pumps of central type AC Plant by cleaning air filters with water washing Pump, fire dampers , blowers , spray nozzles , condensate water tray, greasing of blower bearing / blower motor, tightening all bolts, nuts and testing for proper functioning all as specified and as directed. (Note :- AHU servicing shall be done once in 3 month)
AHU at Auditorium
AHU at Engine holding bay
AHU at Sonabouy.
AHU at MK 54.
AHU at Magazine A.
AHU at Magazine B&C
lakshmibuilders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .