Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAccepted-AOC | L1 | Accepted-AOC being lowest L1 | |
| 2 | L2₹17.5 L+₹23,814 (1.38%)Rejected-Finance 2 16 AJEET GANJ II BABUPURWA KANPUR KANPUR NAGAR UTTAR PRADESH 208011 | KANPUR NAGAR | UTTAR PRADESH | 208011 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹17.7 L+₹52,749 (3.06%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹18.3 L+₹1.0 L (6.01%)Rejected-Finance | L4 | Rejected-Finance Other than lowest |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
10 Nov 2021, 6:00 pmClosed
GE (AF) PATHANKOT
GE (AF) PATHANKOT-145001
ADDITION/ALTERATION OF AUDITORIUM CUM CINEMA HALL AT AIR FORCE STATION PATHANKOT
2021_MES_481748_1
8420/GE/PAF-47/2021-22
Open Tender
Support/Maintenance Service
Item Rate
180 days
GE (AF) PATHANKOT
As per NIT
7 documents required · 7 mandatory
₹500
GE (AF) PATHANKOT
₹38,000
Yes
31 Dec 2021
13 Oct 2021
12 Nov 2021
13 Oct 2021
10 Nov 2021
27 Oct 2021
Amount
Remove all loose gravel cement mortar, loose cement concrete , dirt, oil, grease and foreign material by jet of dry air and clean the surface mechanically or by grinding to make it smooth before application. Repair all cracks by cutting “V” groove and fill with PMC mortar prepared in the ratio of ShaliCrete : Cement : Sand (1 : 2 : 5). Ensure gradient of 1 : 100 towards drain by laying cement concrete type B0 1:2:4 admixed with integral waterproofing compound, ShaliPlast LW+ @ 200 ml / bag of cement or equivalent . Ensure that there is no standing water on the applicable surface. Stir ShaliUrethane® BTD or equivalent by a slow speed mixture fitted with a suitable mixing paddle to ensure a homogenous mix. (Mixing of Water is totaly prohibited ). After stirring, wait for the product to settle in order to let entrapped air escape. Slightly damp the surface. Avoid standing water / ponding. Prime the surface using ShaliPrime BTD @ 400 grm / Sqm. Allow the primer to touch dry condition. Apply 1st coat of ShaliUrethane® BTD confirm to ASTM C 836 and ASTM D 6083 @ 1 Kg / Sqm by brush / roller while the primed surface is tacky. Spread non-woven geo-textile of 45 gsm with overlaps of 50 mm in both directions when the surface is still tacky.Allow 1st coat to dry for 10 – 12 hr. Apply 2nd coat of ShaliUrethane® BTD @ 1 kg / Sqm by brush / roller for final dry floor thickness 1.5mm in two coats . Ensure final curing time of 36 hrs before allowing / carrying out any further work. Extend waterproofing treatment up to 200 mm and terminate into groove on the parapet wall. Fill the groove with PMC mortar with ShaliSBR Latex complete all as specified and directed by Engr-in-charge. Note : (i)Application of water proofing treatment will be done by Authorised Applicator only . (ii) Rate for removal of debries obtained from the work to be disposed a distance not less than 2Km incl in the rate quaoted by the contractor.
Supply and fixing in repair vitreous china wash hand basin white of bowl size 550 x 440mm including waste coupling and PVC waste pipe, 32mm dia, 15 mm dia bore pipe pillar tap cast copper alloy with capstan heads chromium plated fancy to be fixed in M S brackets complete all as specified and directed by Engr-in-charge.
Rendering or plastering work 10mm thick in CM 1:3 in fascia or edging of Chajjas, and roof projections etc, including taking out pealed off plaster / concrete and making the line in true shape and finishing the surface without using extra cement etc complete all as specified and directed by Engr-in-charge.
Rendering or cement plaster 15mm thick in CM 1:4 on bricks on concrete surfaces finishing the surfaces even and smooth without using extra cement including taking down existing plaster new surface complete all as specified and directed by Engr-in-charge.
Preparation of CGI/PGI sheet roof surfaces by removing all loose dust, corrosin, oil, grease and foreign material by jet of dry air and clean the surface mechanically or by grinding to make it smooth before application. Replace all damage J ook, L hook and washer. Ensure that there is no standing water on the applicable surface. Stir ShaliUrethane® BTD or equivalent by a slow speed mixture fitted with a suitable mixing paddle to ensure a homogenous mix. (Mixing of Water is totaly prohibited ). After stirring, wait for the product to settle in order to let entrapped air escape. Slightly damp the surface. Avoid standing water / ponding. Prime the surface using ShaliPrime BTD @ 400 grm / Sqm. Allow the primer to touch dry condition. Apply 1st coat of ShaliUrethane® BTD confirm to ASTM C 836 and ASTM D 6083 @ 1 Kg / Sqm by brush / roller while the primed surface is tacky. Spread non-woven geo-textile of 45 gsm with overlaps of 50 mm in both directions when the surface is still tacky.Allow 1st coat to dry for 10 – 12 hr. Apply 2nd coat of ShaliUrethane® BTD @ 1 kg / Sqm by brush / roller for final dry floor thickness 1.5mm in two coats . Ensure final curing time of 36 hrs before allowing / carrying out any further work. Extend waterproofing treatment up to 200 mm and terminate into groove on the parapet wall. Fill the groove with PMC mortar with ShaliSBR Latex complete all as specified and directed by Engr-in-charge. Note : Application of water proofing treatment will be done by Authorised Applicator only .
M & L in repair and Providing and fixing tiled false ceiling of size (600x600)mm in true horizontal level suspended on inter locking Matrix metal grid of hot dipped galvanized steel sections. It consists of main "T" runner of size 24x38x0.3x3600mm, cross "T" of size 24x25x0.3x1200mm, secondary cross "T" of size 24x25x0.3x600mm and PPGI wall angle of size 24x24x0.4x3000mm. Bottom exposed. capping of width 24 mm of all T-sections shall be of 0.25mm thick PPGI. PPGI wall angle. 24x24x0.4x3000mm {Material-GI(IS513), YS-280Mpa, Finish-Galvanised 90GSM(IS277)} is fixed along the perimeter of the ceiling to Walls, partitions or columns etc., with wooden screws at 300mm centers or Hilti HPS 6 x40mm placed at 600 mm c/c. Gyproc® soffit cleat 27x37x25x1.6mm {GI(IS513)YS-260Mpa,Finish-Galvanised 120GSM(IS277) } is fixed with Rawl Plug- Ø8x45mm {Material-IS 513 CR2 grade, Zinc coating (7 to 8 microns) pull out load- 6.8kN for M30 concrete grade} creating 1200mm x 1200mm grid. Main-T runners. 24x38x0.3x3600mm {GI(IS513)YS-280Mpa,Finish-Galvanised 120GSM(IS277) } are then suspended at 1200mm c/c from ceiling using 4mm zinc electroplated butterfly level clips of size. 85x30x0.8mm spaced at maximum 1200mm center to center along main T and not more than. 150mm from spliced joints. The last hanger at the end of each main runner should not be greater. than 600mm from the adjacent wall. 24x25x0.3x1200mm cross T {GI(IS513)YS-280Mpa,Finish- Galvanised 120GSM(IS277) } is interlocked between the main T at 600mm center to center to form a grid of 1200x600 mm and then secondary cross “T" 24x25x0.3x600mm {GI(IS513)YS- 280Mpa,Finish-Galvanised 120GSM(IS277) } is then interlocked at middle of the 1200x600mm grid to form grids of 600x600mm. Cross Tees at the ends having length more than 600mm are to be supported independently. Finally 12.5 mm thick Fultone Tile, fully Perforated Gypsum unpainted tile of size 595x595 mm, having perforation of 9.7x9.7 mm square. shape at 9.7 mm c/c with center borders of 48mm and the side borders of 30mm, backed with non woven tissue, is placed in grid. For NRC 0.85-0.88, resin bonded glass wool of 24kg/M3 and 50mm thick is placed over Fultone tile complete all as specified and directed by Engr-in-charge.
Supply and fixing of powder coated aluminum door using 96.6mmx44.8mm x1.6mm aluminium chowkhats 84.0 x 44.7mm x 1.6mm section vertical styles 101.60 x 44.88 x 1.6 mm rails mounted on floor spring mortice lock (Make : Godrej/Harrison)02 Nos tower bolt 150mm, sliding bolt 300mm long 01 No, door handles and fittings complete all as directed by Engineer-in-Charge bottom panel with 12mm thick PVC board with density not less 600kg per cum and top panel with 5.5 mm thick plain glass ficed with snap beading rubber of suitable size and each shutter n.exc 0.95 m in width complete all as specified and directed by Engr-in-charge.
Light shade vitrified tiles 10mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm as in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles including 15mm thick screed bed or bedding layer in CM 1:4 and dismantling/demolition on existing surface complete all as specified and directed by Engr-in-charge.
Granite (of any type), 18- 20mm thick (table rubbed and polished) in steps, jambs, pillars, window cills,cooking platform and like in cement mortar (1:4) incl pointing in white cement (1:2) using marble dust with admixer of pigment to match with marble shade including making full curving the edges complete all as specified and directed by Engr-in-charge.
Closing bolt holes or other similar holes in old CGI sheets by sealing withone bitumen and one plain G.I. washer on either side and 8mm dia bolt and nut, bolt not exceeding 25mm in length complete all as specified and directed by Engr-in-charge.
Preparation of newly plaster surfaces of wall and projection and applying two coats of acrylic exterior emulsion paint as approved of any shade/colour over a coat of primer including preparation of surfaces as per manufacture instructions complete all as specified and directed by Engr-in-charge.
Point wiring with 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade, FRLS grade in and including medium duty concealed PVC conduit 20 mm dia or higher and conduit fittings and all accessories with suitable size of sunk type cast iron or pressed steel terminal box 1.2mm thick, duly painted for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, including contineous earth wire PVC insulated, unsheathed, multi stranded copper conductor cable 1.5 sqmm (nominal area) FRLS grade, green colour, up to common earth and connected to earth dolly compete all as specified and directed by Eng.-in-charge of the following. (Note: Colour code shall be maintained as per IE rule). (a) One light point/ /Fan/Exhaust /bell buzzer point controlled by one, one way switch
Supply and fixing of switch piano flush type single pole one way 230 Volts 5/6 Amp compete all as specified and directed by Eng.-in-charge
Supply and fixing of Switch piano flush type single pole, one way, 230 volts 15/16 Amps ISI marked complete all as specified and directed by Engr- in – charge.
Supply and fixing LED luminaire 600 mm x 600 mm, 40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engr- in – charge.
Sub main wiring with 2 Single core FRLS PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 1.5 Sqmm (nominal area) drawing in and including 20mm dia medium duty PVC concealed conduit and conduit accessories and fittings. Including one single core green colour FRLS, PVC. Insulated unsheathed multi stranded copper conductor cable of size 1.5 Sqmm as earth continuity conductor upto common earth and connected to earth dolly complete all as specified and directed by Engr- in – charge. (Note: Three run 1.5 Sqmm cable and one run conduit shall be measured as one run.)
Sub main wiring with 2 Single core FRLS PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size2.5 Sqmm (nominal area) drawing in and including 20mm dia medium duty PVC concealed conduit and conduit accessories and fittings. Including one single core green colour FRLS, PVC. Insulated unsheathed multi stranded copper conductor cable of size 2.5 .0 Sqmm as earth continuity conductor upto common earth and connected to earth dolly complete all as specified and directed by Engr- in – charge. (Note: Three run 2.5 Sqmm cable and one run conduit shall be measured as one run.)
Supply and fixing ceiling fan complete with down rod of suitable lengthe as required at site, AC single Phase 230 V, 1400mm sweep with blades including mounting arrangements complete all as specified and directed by the Engr-in-charge.
Supply and fixing of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd complete all as specified and directed by the Engr-in-charge.
Supply and fixing of LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by the Engr-in-charge.
Supply and fixing of Air Circulator fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting complete all as specified and directed by Engr In Charge.
KUMAR TRADING CO
M/S RAJESH SHARMA & CO.
M/S SINGHAL ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .