Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹36.6 L+₹2.5 L (7.48%)Rejected-Finance S 5 POST OFFICE BUILDING BATWARA SRINAGAR | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹40.6 L+₹6.6 L (19.4%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | Rejected-Technical DHOBI MOHALLA BATMALOO SRINAGAR 190010 J K | SRINAGAR | SRINAGAR | J K | 190010 | - | Rejected-Technical Due to non eligible appropriate category | |
| 5 | Rejected-Technical | - | Rejected-Technical Due to non eligible appropriate category |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
8 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 133 WORKS ENGRS
HQ 133 WORKS ENGRS PIN-914133 C/O 56 APO
REPAIR MAINTENANCE OF DISTRIBUTION TRANSFORMER VOLTAGE STABILIZER INCLUDING ALLIED WORKS AND REPAIR MAINTENANCE REPLACEMENT OF 33 KV AND 11 KV HT NETWORK AT BB CANTT UNDER GE 864 EWS
2021_MES_458807_2
CWEK-34/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 864 EWS
Class D Category b iii
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹60,000
Yes
HQ 133 WORKS ENGRS
2 Nov 2021
18 Aug 2021
10 Sept 2021
18 Aug 2021
8 Sept 2021
1 Sept 2021
18 Aug 2021 - 25 Aug 2021
28 Aug 2021
60 days
Amount
M&L for loading, unloading, transportation to factory premises of burnt/defective distribution transformer of capacity 500 KVA, to 630KVA, 11 KV/433 volts 3 phase from AGE E/M Yard, opening of top cover of faulty transformer, taking out the core assembly and removing burnt out windings, dehydrating the core assembly, reassembling transformer after repair, replacement of complete gasket set, draining out the transformer oil including cleaning and varnishing, refilling the oil duly filtered/dehydrated, topping up with new oil, carrying out routine tests, including transportation back to site, testing and commissioning of the repaired transformer at site on full load after making cable and earthing connections complete all as specified and directed Note :- (i) The checking / finding of fault should be carried out only in presence of Engineer-in-Charge or his rep (ii) The copper winding will be measured and paid seperately. (iii) New transformer oil, Dehydration of Transformer oil, painting shall be measured and paid seperately. Bushing assy/bush rod/insulators are measured and paid separately.
All as per Item No 01 here-in-before above but distribution transformer of capacity 315 KVA to 400 KVA.
All as per Item No 01 here-in-before above but distribution transformer of capacity 200 KVA to 250 KVA.
All as per Item No 01 here-in-before above but distribution transformer of capacity 100 KVA to 160 KVA.
All as per Item No 01 here-in-before above but distribution transformer of capacity 63 KVA.
Rewinding of LT side winding with copper strip of suitable size/ gauge, fixing the coil in position in core assembly and making connection as per existing pattern including providing insulation, varnish etc complete all as specified and directed by Engr-in-charge. Note:- (The rewinding of transformer shall be done only after certification by BOO or Engineer-in-Charge declaring the old winding as unserviceable.)
Rewinding of HT side coil with supper enamelled Copper wire of suitable size/ gauge, fixing the coil in position in core assembly and making connection as per existing pattern including providing insulation, varnish etc complete all as specified and directed by Engr-in-Charge. Note:- (The rewinding of transformer shall be done only after certification by BOO or Engineer-in-Charge declaring the old winding as unserviceable.)
Painting the outer surface of the transformers/Voltage stablizers with two coats of synthetic enamelled paint after preparing the surface to dust and oil free and cleaning the bushes, name plate etc paint free after painting including writing MES/ SM No with enamelled paint complete all as specified and as directed for transformer of rating 50 KVA to 630 KVA (Indoor/ outdoor type).
Transformer oil for topping up or for replacement in Transformers / Servo voltage stabilizer complete all as specified and as directed. Make: Power oil/ Savita Note: Oil shall be in company sealed barrel having BDV not less than 40KV and Transformer oil topping up or replacement should be done on existing installation place on same days)
Transformer oil filteration & dehydration by Ultra High Vaccum Double stage machine to remove impurities from oil such as moisture, dirt, air and other gases and to improve BDV upto 60KV at 2.5mm air gap complete all as directed by Engr-in-Charge. Note: (Transformer oil filteration & dehyration by Ultra High Vaccum double stage machine should be done on existing installation place on same days).
Supply and replacement of silica gel only with fresh blue coloured complete all as specified and as directed.
Dismantling of old Burnt Tap changer and Supply and fixing new tap changing switch as per existing size including making connection to transformer of various capacities/make complete all as specified and as directed.
Supply and replacing HT/LT side cable box cover plate made out of MS sheet of 18 SWG complete with nuts, bolts, washers suitable for indoor/outdoor type transformer of capacity 63 KVA to 400 KVA..
GI strip of size 32x6mm as earth continuity conductor burried in ground or drawn in pipe or fixed to wall on saddle.
Disconnecting HT/LT cable/busbar and Earthing connections complete of transformer capacity up to 63 KVA, 11 KV/433 Volts 3 phase from pole/floor/transformer shed with the help of Crane to carry out complete maint of transformer comprising of the following:- (i) Draining out oil from chamber. (ii) Opening top cover, disconnecting winding connection from bushings and taking out carefully core assembly complete with winding. (iii) Checking compactness of core & tightening the same where required. (iv) Chemical washing of winding to remove dirt,dust & carbon particles (v) Cleaning of oil tank to remove oil sludge followed by painting of inner surface of tank with zinc chromate base paint (vi) Refixing of core & winding assembly and making connection with HT/LT bushing . (vii Replacement of worn out gaskets & nut/bolts. (viii) Refilling of oil duly filtered/dehydrated/fresh oil (to be measured & paid separately under respective item). (Note: Overhauling of transformer should be done on existing installation place on same days)
All as per Item No 15 here-in-before above but 100 KVA.
Supply and installed of MC TRMS PCB complete all as specified and directed.
Supply and installed of contractor 100 Amps, 3 Phase complete all as specified and directed.
Supply and installed of 3 Kg motor sync complete all as specified and directed.
Supply and installed of MC TRMS PCB complete all as specified and directed.
Supply and installed of RC complete all as specified and directed.
Supply and installed of Carbon bush complete all as specified and directed.
Supply and installed of closer sheet complete all as specified and directed.
Supply and installed upto 20 Kg motor sync complete all as specified and directed.
Supply and installed of Carbon roller assy complete all as specified and directed.
Supply and installed of Tag & Tail assy complete all as specified and directed.
Supply and installed of PCB Relay (1003) complete all as specified and directed.
Supply and installed of flip flop complete all as specified and directed.
Supply and installed of Time delay relay complete all as specified and directed.
Supply and installed of limit switch (B4C) complete all as specified and directed.
Supply and installed of power contractor complete all as specified and directed.
Supply and installed of Aux contracor 4 Nos +4NC 44W, 230V AC complete all as specified and directed.
Supply and installed of Aux contracor 6 Nos +2NC 62W,110V AC complete all as specified and directed.
M & L for replacement of HT 11 KV bush insuulator suitable for distribution transformer of any type of size upto 200 KVA complete all as specified and directed.
M & L for replacement of HT 11 KV bush insuulator suitable for distribution transformer of any type of size upto 250 KVA to 630 KVA complete all as specified and directed.
M & L for replacement of LT 11 KV bush insuulator suitable for distribution transformer of any type of size upto 200 KVA complete all as specified and directed.
M & L for replacement of LT 11 KV bush insuulator suitable for distribution transformer of any type of size upto 250 KVA to 630 KVA complete all as specified and directed.
Supply and fixing in replacement HT bush rod made out of brass complete with brass spindle, nuts, bolts, washers etc without bushing insulators suitable for transformer of capacity 200 KVA complete all as specified and as directed.
Supply and fixing in replacement HT bush rod made out of brass complete with brass spindle, nuts, bolts, washers etc without bushing insulators suitable for transformer of capacity 250 KVA to 630 KVA complete all as specified and directed.
Supply and fixing in replacement LT bush rod made out of brass complete with brass spindle, nuts, bolts, washers etc without bushing insulators suitable for transformer of capacity upto 200KVA complete all as specified and directed.
Supply and fixing in replacement LT bush rod made out brass complete with brass spindle, nuts, bolts, washers etc without bushing insulators suitable for transformer of capacity 250 KVA to 630 KVA complete all as specified and directed.
M & L for fixing GI funnel complete with wire mesh for earthing water pipecomplete all as specified and directed.
M & L for each pit cover of size 300x300x40mm thick of RCC M-15( Nominal mix) using 20mm graded stone aggregate with MS TMT reinforcement bar of 8mm dia @ 150mm centre to centre both way, MS handle 10 mm dia made to shape complete all as specified and directed.
Earthing, complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (Earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connecting to the galvanised iron earth strip of size 32x6 mm dia by means of bolts, nuts, check nuts and washers of galavanised iron and earth strip protected by provision of GI light grade pipe 20mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded of stone aggregate with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and with 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate common salt and charcoal filling test point made out of 40mm/6mm flat iron with fixing arrangement funnel wire mesh and earth work in hard dense soil returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as per electrical plate No 03 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion complete all as specified and directed. Note :- GI strip and GI pipe beyond 7.5 Mtr length from earth electrode shall be measured and paid separately.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1,5 mtrs in depth for laying of cables including getting out in any type of soil complete all as specified and directed.
Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any type of soil complete all as specified and directed.
Removing surplus excavated material i.e. soil from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Sand cushioning for cables 8 cm below the cable and 15 cm above the cable all as specified and directed complete all as specified and directed.
Reinforced precast concrete cable cover, class HV, type-1 , with peak, size 300mmx180mmx40mm thick laid dry and abuting each other with gap between adjacent slab not exceeding 10mm over under ground cable for cable protection complete all as specified and directed.
Disconnecting/taking out existing unserviceable / damaged LT/HT underground cable/Service cable from trenches /ducts or from to poles/walls or under roads /paths/drains/culverts and depositing the same in the store yard of AGE E/M cable size of 95 sqmm 3.0 core complete all as specified and directed
Disconnecting/taking out existing unserviceable / damaged LT/HT underground cable/Service cable from trenches /ducts or from to poles/walls or under roads /paths/drains/culverts and depositing the same in the store yard of AGE E/M cable of size 240 sqmm 3.0 core complete all as specified and directed
Supplying, laying or fixing, jointing and testing HT under ground electric power cable , XLPE insulated, screened , PVC bedded ,galvanised steel strip or wire armoured, (conforming to ISI-7098) , ISI Marked, with aluminium conductor multi-stranded , heavy duty ,11000 Volts grade ( earthed ) , laid in trenches/ laid under floor,roads,paths or fixed on walls / on poles/ in ducts etc cable of size 95 sqmm 3 core complete all as specified and directed Note: Excavation and GI Tubing earthwork shall be measured and paid seperately under respective items
Supplying, laying or fixing, jointing and testing HT under ground electric power cable , XLPE insulated, screened , PVC bedded ,galvanised steel strip or wire armoured, (conforming to ISI-7098) , ISI Marked, with aluminium conductor multi-stranded , heavy duty ,11000 Volts grade ( earthed ) , laid in trenches/ laid under floor,roads,paths or fixed on walls / on poles/ in ducts etc cable of size 240 sqmm 3 core complete all as specified and directed Note: Excavation and GI Tubing earthwork shall be measured and paid seperately under respective items
Supplying, fixing, jointing and testing heat shrinkable cable end joint ,indoor/ out-door type with and including jointing materials suitable for 11 KV , XLPE cable of size (50 to 95) sqmm , 3 core , complete all as specified and directed .
Supplying, fixing, jointing and testing heat shrinkable cable straight joint , out-door type with and including jointing materials suitable for 11 KV , XLPE cable of size (50 to 95) sqmm , 3 core , complete all as specified and directed .
Supplying, fixing, jointing and testing heat shrinkable cable straight through joint , out-door type with and including jointing materials suitable for 11 KV , XLPE cable of size (240 to 400 sqmm) , 3 core, complete all as specified and directed .
S&F of tubing 100 mm bore 'light grade' galvanised iron ISI marked with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete all as specified and directed
S&F of tubing 80 mm bore 'light grade' galvanised iron ISI marked with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete all as specified and directed
Dismantling of U/S HT 11 KV/33 KV isolator or air break switch (GOD) tripple pole with all accessories from HT poles complete all as specified and directed.
Supplying, installing, testing and commissioning of air break switch (GOD) HT 11 KV, AC 50C/S, TP Horizontal mounting type, mechanically operated from ground, mounted on 12 insulators 11 KV grade and steel frame, current rating upto 200 Amps complete with fuse mounts, fuse carriers and fuse elements of required capacity and one pad lock 65 mm (Godrej/navtal) with two keys all as specified and directed.
Dismantling of U/S HT 11 KV lightning arrestor non-linear expulsion type with fitting from HT poles complete all as specified and directed.
Fault detection, repairing and rectification of defects, pertaining to external electric power supply of under mentioned HT distribution network incl foot patrolling from stating to end point of entire area (khukri post) and detecting of faults like overhead conductor broken, pin/sackle insulator damaged/broken HT joints brust etc to be disconnected and and restore power supply round the clock all as directed by Engineer-in-Charge
Supply and fixing in replacement Post type insulator porcelain vitreous white, brown or green 254mm high and 210mm, including one galvanised iron spindle, two galvanised iron washers and one galvanised iron nut, suitable for conductor of working pressure 33 KV, complete all as specified.
Supply and fixing in replacement Three in series, disc insulator assembly in replacement of disc type insulator porcelain vitreous ball and socket type,white, brown or green insulator including hardware fitting and other acessories suitable for 33 KV volt, complete all as specified..
Cutting arround and trimming of tree branches MRS to Dal Lake both side of HT 33/11 KV over head lines upto minimum clear distance 1.50 meter from either side including cleaning the site and disposing off cut tree/branches from site to a distance not exc. 50m and clearing the site as directed by Engr-in-Charge. Note:-Any damage caused to overhead lines due to cutting of tree branches shall be made good by the contractor without any extra cost.
Cutting arround and trimming of tree branches Atal feeder to Khukri Post both side of HT 33/11 KV over head lines upto minimum clear distance 1.50 meter from either side including cleaning the site and disposing off cut tree/branches from site to a distance not exc. 50m and clearing the site as directed by Engr-in-Charge. Note:-Any damage caused to overhead lines due to cutting of tree branches shall be made good by the contractor without any extra cost.
Supply,fixing in replacement ,commissioning and testing Switch Air break Isolator outdoor type HT 33 KV, triple pole, 400 Amps, double stake type with fixed contacts and moving contacts of copper with mechanically operated rod from ground level, vertical / horizontal mounted complete with HT insulator on and including steel frame ,operating rod made out of 25mm dia GI pipe medium grade with 9 insulators with test point complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep in any type of soil complete all as specified and directed.
Supply and filling of 40mm graded stone aggregate for loose filling complete all as specified and directed.
Supply and filling of fine sand for loose filling complete all as specified and directed.
Supply,designe, transportation, loading, unloading, installation, testing and commissioning of LT switch gear 440 volts, 50 KA, 3 phase, 4 wire 50 cycles cubicle or trunck type microprocessor based Outerdoor type complete with air circuit braker, overload protection, No volt release with necessary CTs, meters and cable boxes of rating upto 1000 Amps Including taking down old one complete all as specified and directed by Engineer in charge. Make: Lagrand cat Part No:028732 or equivalent of L&T/ SIEMENS,/ Schneider.
Supply,designe, transportation, loading, unloading, installation, testing and commissioning of LT switch gear 440 volts, 50KA, 3 Phase, 4 wire 50 cycles, cubicle or trunck type microprocessor based, indoor type complete with air circuit breaker, overload protection, No volt release with necessary Cts, meters and cable boxes of rating upto 800 Amps including taking down old one complete all as sepefied and directed by Engineer in charge. Make: Legrand cat part No: 028731or equivalent of L&T/ SIEMENS,/ Schneider.. Note For Srl item No:71 & 72 (a) The ACB should be fixed in a sheet metal enclosure of 2 mm thick MS sheet for Indoor type and 3.15mm thick M/S sheet for Outdoor type all as directed by Engineer in Charge at site. (b) The enclosure should be mounted on Angle Iron frame of size 50x50x6mm grouted 60cm above ground level/embedded in PCC foundation as per manufacturer instruction. (c) The above items i.e enclosure/angle iron frame and PCC work are deemed to be included in the quoted rates.
M & L for replacement of ACSR (Aluminium conductor steel reinforced) conductor of any size on poles including binding wire of appropriate size complete incl clearing of path and branch cutting etc all as specified and as directed
Stay assembley complete with all accessories as shown in elect plate No 1 of SSR Part-I consisting of stay rod 20mm dia, 2.15 m long stay plate 300 x 300 x 6 mm complete all as shown on drawing and as directed
M & L for galvanized stay wire stranded 7/4 mm including taking down old one complete all as specified and as directed
M & L for iron work of any type incl cross arms, supports, bracing MS clamps etc made out of MS channel/angle iron/flat iron/ round section of any size and bolt nuts and washer including painting with two costs of aluminium paint over a coat of red oxide all as specified and as directed
Supply, installation, testing and commisioning of Lightining Arresters Linear type, distribution class with all fittings and fixing arrengements suitable to 11000 volts grade and discharge capacity 12 KV / 10 KA with and including making connections with suitable size of ACSR conductor including taking down old one complete all as specified and directed.
Maintenance and complete overhauling of 33 KV, VCB out door including disassembling of operating mechanism parts, well cleaning with petrol & CRC-226 and replacing minor parts reassembling of parts including well cleaning the complete panel board, main bus bar, de-carbonizing all joints bus bar, CTs, PTs, spouts metal parts and making VCB perfect operating in manual and electric mode including all routine and preventive maintenance complete all as specified and directed. Note :- spare parts will be measured and paid separately as under
Dismantling of U/S CT and S&F 33 KV single phase outdoor oil cooled CT of ratio 150/5-5 Amps class insulation level 65 KV/75 KV as per IS-2705 complete all as specified and directed. .
Dismantling of U/S PT and S&F 33 KV single phase outdoor oil cooled PT of ratio 150/5-5 Amps class insulation level 12 KV as per relevent IS.
Dismantling of steel tubular pole 9 Mtr long complete all as specified and directed.
Fixing only steel tubular pole type 410 SP-31 (9 Mtrs long).complete all as specified and directed. Note :- Excavation, earthwork and PCC shall be measured and paid seperately under relevant items
Supply and erecting in vertical position steel tubular swaged pole type 410 SP-55 (11 metre long) with 300mmx300mmx6mm mild steel base plate continuously welded to pole, finial taper, nut, bolts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and applying one coat of red oxide primer for the remaining portion and two coats of aluminium paint beyond 1.5M from ground level/coping and making 30cm black and white strips with two coats of super enameled paint up to 1.5M from ground level/coping complete all as specified and directed.
M & L for PCC 1:4:8 type D-2 with (using 40mm graded stone aggregate) in foundation of poles all as specified and as directed
M & L for PCC 1:2:4 type B-1 with (using 20mm graded stone aggregate) in coping of poles/stays including necessary form work all as specified and as directed
Excavation in trenches n.exc 1.5mtr wide and n exc 3 mtr in depth and getting out in soft/ loose soil for laying of cables, foundation of pole, stay etc complete all as specified and as directed.
Supply and fixing in replacement Pin type insulator porcelain vitreous white, brown or green 150mm high and 150mm, including one galvanised iron spindle, two galvanised iron washers and one galvanised iron nut, suitable for conductor of working pressure 33 KV, complete all as specified.
Supply,fixing in replacement ,commissioning and testing HT 11KV vaccum interupter cylinder suitable for HT 11 KV VCB breaker complete all as specified and as directed. Make :- Areva/CG/BHEL.
Note :- Contractor should be replace the accessories of voltage stablizer Srl Item No 15 to 33 by the authorised service Enginner only.
ALCO ENGINEERSPVT LTD
M/S MARVEL ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .