| Sl No | Description | Qty | Unit | NPK Associates L2 | NMS ENGINEERS L1 |
|---|---|---|---|---|---|
| 1.00 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete (Sl.No.01 P No 01) | 60 | m3 | 221 ₹13,260 | 220 ₹13,200 Lowest |
| 2.00 | Plain Cement concrete 1:4:8 [one cement, four M-sand and eight course aggregates] using 40mm size Hard Broken / Machine crushed Granite Stone Jelly including dewatering if found necessary and laid in layer so not more than 15cm thick and compacted etc., complete complying with standard specification. | 7 | m3 | 6,062 ₹42,418.85 | 6,060 ₹42,404.85 Lowest |
| 3.00 | Providing cast in situ cement concrete 1: 11/2 : 3 (one cement, one and half M.Sand and three coarse aggregate) using 20mm size HBBG metal for 23cm dia pile including cost of materials labour, hire charges for machinery for earth work for forming 23cm dia bore hole to the required depth before concreting excluding cost of steel reinforcement etc complete (Sl.No.04 P No 112 of 2024-25) | 50 | Rm | 2,510 ₹1,25,500 Lowest | 2,510 ₹1,25,500 Lowest |
| 4.00Supplying and erecting Shuttering, necessary supports for plain surfaces such as reinforced cement concrete for plinth beam including decentering after curing period, complete complying with standard specifications at all leads inside the building etc complete.., | |||||
| 4.01 | For Plinth beam (Sl.No.12 P No 41) | 50 | m2 | 1,069 ₹53,450 Lowest | 1,070 ₹53,500 |
| 4.02 | For Compound wall plinth beam | 20 | m2 | 2,629 ₹52,580 Lowest | 2,630 ₹52,600 |
| 4.03 | For RCC slab (Sl.No.13 P No 41) | 10 | m2 | 2,191 ₹21,910 | 2,190 ₹21,900 Lowest |
| 5.00 | Reinforced Cement Concrete M20 (Mix 1:1 1/2:3, one part of cement, one and half parts of sand , three parts of 20 mm hard blue granite metal by volume, characteristic strength not less than 20 N/sqmm) machine mixed for all reinforced Cement Concrete works, including scaffolding, cost of all materials, machine mixing, vibrating, lifting, curing, labour charges for laying & finishing etc., but excluding the cost and fabrication of reinforcements and also excluding centering and formwork etc., complete complying with the relevant standard specifications at all leads inside the building etc complete., | 11 | m3 | 10,105 ₹1,11,155 | 10,100 ₹1,11,100 Lowest |
| 6.00 | Supply and Fabricating of reinforcement steel of all diameters for reinforced cement concrete works at all heights and depths including straightening, cleaning, cutting, bending, placing in position and binding, hoisting and welding if any including cost of power, electrodes etc, cost of annealed binding wire (18 gauge), providing overlaps, tying in position and providing necessary cover blocks for all works as per detailed drawings supplied (including chairs, cranks, lap rods, spacer bars, fan hooks etc.,) with the relevant standard specifications, complete for all leads & lifts. | 11 | Qtl | 9,654 ₹1,06,194 | 9,650 ₹1,06,150 Lowest |
| 7.00 | Flyash brick work in cement mortar 1:5 (one part of cement and five parts of sand by volume) for superstructure, entrance & staircase steps etc., using first class table mould chamber burnt bricks of crushing strength 40kg/sq cm (minimum) & water absorption should be less than 20%, including scaffolding, soaking of bricks, raking of joints, hacking of concrete surfaces coming in contact with brickwork, curing etc.,complete complying with relevant standard specifications, at all leads | 11 | m3 | 8,041 ₹88,451 | 8,040 ₹88,440 Lowest |
Tender Value
₹57.7 L
EMD Value
₹57,700
Closing Date
29 Jan 2026, 3:00 pmClosed
The Commissioner, Coimbatore Corporation
Coimbatore Corporation, Main Office, Big bazaar street, Town hall, Coimbatore-1
Construction of Sump, Compound wall and water supply arrangements and additional improvement works to the Night Shelter for Homeless (NULM) at Nesavalar colony in Ward No57, East Zone.
2026_MAWS_646448_1
e6/2026-Two cover
Open Tender
Civil Works
Works
150 days
Coimbatore corporation
AS PER TENDER DOCUMENTS
5 documents required · 5 mandatory
₹0
₹57,700
11 Apr 2026
23 Jan 2026
30 Jan 2026
23 Jan 2026
29 Jan 2026
23 Jan 2026
Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete (Sl.No.01 P No 01)
Plain Cement concrete 1:4:8 [one cement, four M-sand and eight course aggregates] using 40mm size Hard Broken / Machine crushed Granite Stone Jelly including dewatering if found necessary and laid in layer so not more than 15cm thick and compacted etc., complete complying with standard specification.
Providing cast in situ cement concrete 1: 11/2 : 3 (one cement, one and half M.Sand and three coarse aggregate) using 20mm size HBBG metal for 23cm dia pile including cost of materials labour, hire charges for machinery for earth work for forming 23cm dia bore hole to the required depth before concreting excluding cost of steel reinforcement etc complete (Sl.No.04 P No 112 of 2024-25)
Supplying and erecting Shuttering, necessary supports for plain surfaces such as reinforced cement concrete for plinth beam including decentering after curing period, complete complying with standard specifications at all leads inside the building etc complete..,
For Plinth beam (Sl.No.12 P No 41)
For Compound wall plinth beam
For RCC slab (Sl.No.13 P No 41)
Reinforced Cement Concrete M20 (Mix 1:1 1/2:3, one part of cement, one and half parts of sand , three parts of 20 mm hard blue granite metal by volume, characteristic strength not less than 20 N/sqmm) machine mixed for all reinforced Cement Concrete works, including scaffolding, cost of all materials, machine mixing, vibrating, lifting, curing, labour charges for laying & finishing etc., but excluding the cost and fabrication of reinforcements and also excluding centering and formwork etc., complete complying with the relevant standard specifications at all leads inside the building etc complete.,
Supply and Fabricating of reinforcement steel of all diameters for reinforced cement concrete works at all heights and depths including straightening, cleaning, cutting, bending, placing in position and binding, hoisting and welding if any including cost of power, electrodes etc, cost of annealed binding wire (18 gauge), providing overlaps, tying in position and providing necessary cover blocks for all works as per detailed drawings supplied (including chairs, cranks, lap rods, spacer bars, fan hooks etc.,) with the relevant standard specifications, complete for all leads & lifts.
Flyash brick work in cement mortar 1:5 (one part of cement and five parts of sand by volume) for superstructure, entrance & staircase steps etc., using first class table mould chamber burnt bricks of crushing strength 40kg/sq cm (minimum) & water absorption should be less than 20%, including scaffolding, soaking of bricks, raking of joints, hacking of concrete surfaces coming in contact with brickwork, curing etc.,complete complying with relevant standard specifications, at all leads
Brick work in CM 1:5 (one cement & Five Crushed Stone Sand (M- Sand)) using II class ground moulded bricks of size 9" X 4 3/8"X 2 3/4" including finishing, curing, etc., complete complying with standard specification - 100CFT ( Sl.No 196 b)
Plastering with cement mortar 1:5 (One part of cement, five parts of P sand by volume) for 12 mm thickness (average), for all internal/external slabs at/slopped/hipped/canopy), sunshades, table top & rack slabs, trenches etc., finished smoothly to one level including hacking concrete surfaces, scaffolding, curing etc., complete, at all leads.
Plastering with cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)) 20mm thick in all floors including cost and conveyance of all materials to site and labour charges etc, complete complying with standard specifications (Sl.No.313)
Supplying and fixing of using M.S doors and windows ,all fixtures,and labour charges etc., complete as per the standard specification and the instruction of the departmental officers etc complete.
Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated unsheathed SC copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires with TW switch box and 5A FT switch in flush with wall with 3mm thick hylum sheet cover for making good of the concealed portion with suitable colour for PVC concealed light point / fan point (for electronic regulator) SD24
Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 150mm x 100mm x 113mm TW switch box with 3mm thick hylem sheet cover for 5A 3 pin non inter locking wall socket with 5A flush type switch with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC plug point SD38.
Wiring with 2 x 4 sq.mm. (56 / 0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 150mm x 100mm x 113mm TW switch box with 3mm thick hylem sheet for 15A 3 pin non inter locking wall socket with 15A flush type switch with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed power plug point. SD 40
Supply, install, test and commission interior 20W 4 Feet LED Fitting with LED as per the direction of dept. officers ect complete. M-1273
Supply and fixing of 1200mm (48") AC Ceiling fan complete with stepped electronic 300W regulator with 1 meter down rod on the existing clamp SD 107 PWD Electrical Data
Supply and fixing of 450mm Sweep wall mounting fan complete with complete accessories M1356 as per PWD std specifications M-1356
Supplying and fixing of 12 Watts LED Round Type Recessed mounted Down Light for ceiling including provision of suitable accessoreis all complete as per specification and direction of departmental officers M-3020
Paving the floor with Tactic paver New Tek type BT Yellow Colour Ceramic Tiles of size 305 mm x 305mm x 15 mm for Vision Impairment Person in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (PSand)), 20mm thick laid in-situ and pointed with same coloured cement etc complete (Sl.No.43A P No 56)
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete (Sl.No.6 P No 116)
Providing and Applying CFTRI approved two component flexible polymer modified acrylic cementitious waterproofing coating with a mix ratio of (1 Liquid: 2 Powder), to the RCC surface like bathroom, toilet, balcony & utility area applied @ 1.7kg/ m2 in 2 coats to achieve 1mm. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification.W-0301
Providing granolithic floor finish of 75mm thickness with plain cement concrete 1:2:4 (One Cement, Two crushed sand (M-Sand) and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers) (Sl.No.250)
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 25GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with spag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown olour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the executive Engineer before use on work Etc As per PWD SOR Page No 65
Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug. M-0673
Supply and fixing of PVC Solid Doors using 19gauge 19mm MS Sq,tubes for styles and frames, 15mm MS Sq.tubes for to, Lock and bottom rails. The Steel Tubes shall be covered with 5mm thick Solid PVC sheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including furniture and fittings. The over all size of styles shall be 50mm X 30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mm X 30mm. The over all size of frames shall be 50mm X 45mm with suitable tabate for housing the shutter etc, complete as per standard specification. (Sl.No.4 P No 116)
Supplying and fixing of Cudappa slab of 40mm thick for Cup board including cost of materials and labour etc complete as directed by the departmental officers and as per standard specification. (P & D data 53)
Providing two coats of wall putty work with smooth finishing as per the directions of departmental officers etc complete
Painting two coats for Interior surface with approved Interior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. (Sl.No.394)
Painting two coats for Exterior surface with approved Exterior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. (Sl.No.404)
Painting two coats with Ready Mixed Enamel Paint over the new iron works of approved quality and colour without priming coat including the cost all materials etc.,complete, in all floors. (Sl.No.368)
Supply and delivery of 1.5 Hp capacity submercible pumpset and fixing of including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc.,complete as per standard specification. M-1060
Supply and laying of 3 core 10 sq.mm. of Armoured Copper Cables for electrical motor, control panel, pressure switch, jockey motor etc., all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: POLYCAB / PARACON / FINOLEX / EQUIVALENT. M-0824
Supply and laying and jointing of PVC & UPVC pipes and specials for water supply and sanitary arrangements etc
25mm dia UPVC pipe
40 mm dia PVC pipe
63 mm OD PVC pipe
110mm OD PVC pipe
110mm OD PVC shoe
450x450mm SFRC man hole cover with frame
25mm dia UPVC elbow
40mm dia PVC elbow
63 mm OD PVC elbow
110mm OD PVC elbow
25mm dia UPVC TEE
40mm dia PVC TEE
63 mm OD PVC TEE
110mm OD PVC TEE
63 mm OD PVC Door TEE
110mm OD PVC Door TEE
25mm dia UPVC Ball valve
Supplying and laying Rubberised interlocking Paver block M40 grade Providing and laying of 63mm thick high strength type conforming IS 15658-2006 of rubberized interlocking paver lock in size of minimum compressive strength of 40N/mm2 in uniform shape of approved make to be laid in flurring bone pattern with sand cushion below the uniform shap of approved non skitting surface in the top and the rate including levelling the base preparation of pavers as sub base, sand cushion 150mm thick laying out of pavement cut the pieces to fix the edge vibring the pavers,sweeping tranporting loading unloading of laying paver block as per standard specification,.
Supply and fixng of TNEB meter board suitable for 3 phase 100A service connection made up of suitable angle iron frame work of size 2 feet x 1-1/2 feet using angle iron of size 1-1/2" x 1-1/2" x 1/4" rigidly fixed on wall covered with hylem sheet of size 2 feet x 1-1/2 feet of 12mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 100A fuse units (500V), 1 No. neutral link, copper earth flat of size 1" x 1/4" with inter connection of EB meter to fuse units by 16 Sq.mm PVC insulated copper wire with earth connection complete SD 130
Designing the Semi Unitised Structural Glazing System with open groove joint as per design intent, preparation of shop drawings for approval, supply, fabricate, erect as per approved shop drawings at all floor levels and all floor heights including conducting field test as per the test criteria set out in the particular specification (Metholodgy should be got approved by the Dept. Officials.) Design the framing system (i.e. male & Female frame) to support vision panels, spandrel panels either with glass or aluminium composite panel, openable, window panels on a continuous framing supported between floors. Also design the split framing unutilized glazing system in case of strip or punched windows with vision panel proposed with either insulated / Monolithic glass, groove width in the system both in horizontal and vertical shall not be more than 20mm. Glazing of panel shall be done only at factory at the controlled atmosphere. M-0659
Supply and fixing of 4 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A 4P MCB switch as incoming and 12 nos. 6A to 32A SP MCB as outgoing on suitable angle iron frame on wall with earth connection only. SD 621
Supply and run of 4 x 6 sq.mm. (84 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V on 7 / 20 GI bearer wire for service connection mains SD 68
Fabricating supplying and fixing of roof with Poly carbonate sheet of 6mm thcik with any colour or any other approved design and to be fixed with shelf tapping screws, plastic washer. The washer and screws to be fixed by using minute power machine drilled with out damaging the sheets. The sheet to be fixed with making suitable corrugated, cutting the sheet in to the required ssize and making ornamental designs as per the site condition and as directed by the departmental officers. (Sl.No 62 P No 64)
stage.html
html • 0.04 MB
techsummary_774885.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.52 MB
ITB.pdf
Additional Documents • 0.19 MB
Buildingabove50.pdf
Tender Documents • 1.25 MB
BOQ_774885.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .